Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PENETRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Anomalous thermodynamic properties of quantum critical superconductors

Recent high-precision measurements employing different experimental techniques have unveiled an anomalous peak in the doping dependence of the London penetration depth which is accompanied by anomalies in the heat capacity in iron-pnictide superconductors at the optimal composition associated with the hidden antiferromagnetic quantum critical point. Here, we argue that finite temperature effects can be a cause of observed features. Specifically we show that quantum critical magnetic fluctuations under superconducting dome can give rise to a nodal-like temperature dependence of both specific heat and magnetic penetration depth in a fully gapped superconductor. In the presence of line nodes in the superconducting gap fluctuations can lead to the significant renormalization of the relative slope of T-linear penetration depth which is steepest at the quantum critical point. The results we obtain are general and can be applied beyond the model we use.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experiment and model for a Stokes layer in a strongly coupled dusty plasma

A Stokes layer, which is a flow pattern that arises in a viscous fluid adjacent to an oscillatory boundary, was observed in an experiment using a two-dimensional strongly coupled dusty plasma. Liquid conditions were maintained using laser heating, while a separate laser manipulation applied an oscillatory shear that was localized and sinusoidal. The evolution of the resulting flow was analyzed using space-time diagrams. These figures provide an intuitive visualization of a Stokes layer, including features such as the depth of penetration and wavelength. Another feature, the characteristic speed for the penetration of the oscillatory flow, also appears prominently in space-time diagrams. To model the experiment, the Maxwell-fluid model of a Stokes layer was generalized to describe a two-phase liquid. In our experiment, the phases were gas and dust, where the dust cloud was viscoelastic due to strong Coulomb coupling. Furthermore, the model is found to agree with the experiment, in the appearance of the space-time diagrams, and in the values of the characteristic speed, depth of penetration, and wavelength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Strength Assessment for High Levels of Inverter-based Resources in the Puerto Rico Power

A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.

inverter based resources, PR100, grid strength↗

Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Probing Thermal Transport in Fluidized Bed Using Modulated Photothermal Radiometry

Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.

14 SOLAR ENERGY↗

Simulating the Impact of Dynamic Rerouting on Metropolitan-scale Traffic Systems

The rapid introduction of mobile navigation aides that use real-time road network information to suggest alternate routes to drivers is making it more difficult for researchers and government transportation agencies to understand and predict the dynamics of congested transportation systems. Computer simulation is a key capability for these organizations to analyze hypothetical scenarios; however, the complexity of transportation systems makes it challenging for them to simulate very large geographical regions, such as multi-city metropolitan areas. In this article, we describe enhancements to the Mobiliti parallel traffic simulator to model dynamic rerouting behavior with the addition of vehicle controller actors and vehicle-to-controller reroute requests. The simulator is designed to support distributed-memory parallel execution using discrete event simulation and be scalable on high-performance computing platforms. We demonstrate the potential of the simulator by analyzing the impact of varying the population penetration rate of dynamic rerouting on the San Francisco Bay Area road network. Using high-performance parallel computing, we can simulate a day in the San Francisco Bay Area with 19 million vehicle trips with 50 percent dynamic rerouting penetration over a road network with 0.5 million nodes and 1 million links in less than three minutes. We present a sensitivity study on the dynamic rerouting parameters, discuss the simulator’s parallel scalability, and analyze system-level impacts of changing the dynamic rerouting penetration. Furthermore, we examine the varying effects on different functional classes and geographical regions and present a validation of the simulation results compared to real-world data.

97 MATHEMATICS AND COMPUTING↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

INVESTIGATION OF THE MULTILAYER SHIELDING EFFECT THROUGH NbTiN-AlN COATED BULK NIOBIUM

Superconducting radio frequency (SRF) cavities, composed of bulk niobium (Nb), are extensively utilized in particle accelerators. To optimize their performance and extend their operational range, thin films of superconducting materials are applied to the Nb surfaces. This study focuses on investigating the magnetic field penetration characteristics of NbTiN-AlN coating on bulk niobium. The experimental setup involves measuring the magnetic field penetration across flat superconducting samples at cryogenic temperatures. One key parameter of interest is the field just before the first flux penetration, Bp which enables the observation of the multilayer shielding effect on bulk niobium under high magnetic fields. The study reveals a significant enhancement in Bp of the NbTiN-AlN coated Nb samples compared to bare Nb samples. This property holds critical importance for achieving high field performance in SRF cavities. Furthermore, the study explores the relationship between coating thickness and Bp corroborating the theoretical predictions.

Senevirathne, I. H.↗

Experimental Study of Microgel Conformance-Control Treatment for a Polymer-Flooding Reservoir Containing Superpermeable Channels

Summary Polymer flooding has been widely used to improve oil recovery. However, its effectiveness would be diminished when channels (e.g., fractures, fracture-like channels, void-space conduits) are present in a reservoir. In this study, we designed a series of particular sandwich-like channel models and tested the effectiveness and applicable conditions of micrometer-sized preformed particle gels (PPGs, or microgels) in improving the polymer-flooding efficiency. We studied the selective penetration and placement of the microgel particles, and their abilities for fluid diversion and oil-recovery improvement. The results suggest that polymer flooding alone would be inefficient to achieve a satisfactory oil recovery as the heterogeneity of the reservoir becomes more serious (e.g., permeability contrast kc/km > 50). The polymer solution would vainly flow through the channels and leave the majority of oil in the matrices behind. Additional conformance-treatment efforts are required. We tried to inject microgels in an attempt to shut off the channels. After the microgel treatment, impressive improvement of the polymer-flooding performance was observed in some of our experiments. The water cut could be reduced significantly by as high as nearly 40%, and the sweep efficiency and overall oil recovery of the polymer flood were improved. The conditions under which the microgel-treatment strategy was effective were further explored. We observed that the microgels form an external impermeable cake at the very beginning of microgel injection and prevent the gel particles from entering the matrices. Instead, the microgel particles could selectively penetrate and shut off the superpermeable channels under proper conditions. Our results suggest that the 260-µm microgel particles tested in this study are effective to attack the excessive-water-production problem and improve the oil recovery when the channel has a high permeability (>50 darcies). The gels are unlikely to be effective for channels that are less than 30 darcies because of the penetration/transport difficulties. After the gels effectively penetrate and shut off the superpermeable channel, the subsequent polymer solution is diverted to the matrices (i.e., the unswept oil zones) to displace the bypassed oil. Overall, this study provides important insights to help achieve successful polymer-flooding applications in reservoirs with superpermeable channels.

Engineering↗

Electric Power Grid and Natural Gas Network Operations and Coordination

In this report, we present findings from three studies related to the coordination of natural gas and electricity system operations. We first propose and demonstrate a modeling platform for examining the interdependence of natural gas and electricity networks based on a direct current unit-commitment and economic dispatch model for the power system and a transient hydraulic gas model for the gas system. We use this platform to analyze the value of day-ahead coordination of power and natural gas network operations and to show the importance of considering gas system constraints when analyzing power systems operation with high penetration of gas generators and variable renewable energy sources. In the second study, we utilize our modeling platform to consider the U.S. Federal Energy Regulatory Commission (FERC) Order 809, issued in 2015 to improve day-ahead and intraday coordination of power and gas systems. Finally, in the third study we expand our modeling platform to focus on market-based coordination of electricity and natural gas system operations for a real system, namely a subset of the power and gas networks in the Front Range region of Colorado. We use real system data to evaluate the benefits of coordination operations under different conditions, including different levels of renewable penetration and the use of time-variant, shaped flow nominations. Our results indicate that coordination at various timescales can contribute to a reduction in curtailed gas in high-stress periods (such as those with large ramps in gas offtakes) and a reduction in energy consumption of gas compressor stations. We find that intraday coordination can reduce total power system production costs and natural gas deliverability constraints, yielding cost and reliability benefits. We observe these benefits for the test system as well as in the Colorado case study, where we find that coordination and shaped flows may provide additional value for systems with high penetration of variable renewable energy. Together, these three studies demonstrate a pathway for integrated gas and electricity grid modeling and for studying the benefits of coordinated operations of these increasingly interdependent energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Level Considerations for Access and Access Controls by Design

Nuclear power plants must be, by design and construction, robust structures and difficult to penetrate. Ideally, for security, the reactors would be sited underground, beneath a massive solid block, too thick to be penetrated by tools or explosives with all communications and power transfer lines also underground and fortified. Limiting access with difficult-to-penetrate physical barriers is going to be key for determining response and staffing requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Level Considerations for Access and Access Controls by Design

The design and construction of a nuclear power plant must include robust structures and a security boundary that is difficult to penetrate. For security considerations, the reactors would ideally be sited underground, beneath a massive solid block, which would be too thick to be penetrated by tools or explosives. Additionally, all communications and power transfer lines would also be located underground and would be fortified against any possible design basis threats. Limiting access with difficult-to-penetrate physical barriers is a key aspect for determining response and staffing requirements. Considerations considered in a graded approach to physical protection are described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response

Sandia National Laboratories is developing a way to visualize molecular changes that indicate penetration of a tamper-indicating enclosure (TIE). Such "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) allows inspectors to use simple visual observation to readily recognize that penetration into a material used as a TIE has been attempted, without providing adversaries the ability to repair damage. Such a material can significantly enhance the current capability for TIEs, used to support treaty verification regimes. Current approaches rely on time-consuming and subjective visual assessment by an inspector, external equipment, such as eddy current or camera devices, or active approaches that may be limited due to application environment. The complexity of securing whole volumes includes: (1) enclosures that are non-standard in size/shape; (2) enclosures that may be inspectorate- or facility-owned; (3) tamper attempts that are detectable but difficult or timely for an inspector to locate; (4) the requirement for solutions that are robust regarding reliability and environment (including facility handling); and (5) the need for solutions that prevent adversaries from repairing penetrations. The approach is based on a transition metal ion solution within a microsphere changing color irreversibly when the microsphere is ruptured. Investigators examine 3D printing of the microspheres as well as the spray coating formulation. The anticipated benefits of this work are passive, flexible, scalable, cost-effective TIEs with obvious and robust responses to tamper attempts. This results in more efficient and effective monitoring, as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time-consuming visual examination. Applications can include custom TIEs (cabinets or equipment enclosures), spray-coating onto facility-owned items, spray-coating of walls or structures, spray-coatings of circuit boards, and 3D-printed seal bodies. The paper describes research to-date on the sensor compounds and microspheres.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Securing Distributed Energy Resource Integration

The penetration of distributed energy resources (DER) is growing at much higher rates than predicted 20 years ago. Far from being used only in residential settings, DER are now installed on distribution and transmission circuits. In this position, they do not have the same properties as traditional generators and are more flexible in many cases. The growing penetration and range of uses for DER motivate the need to reliably and safely integrate them into the grid. Operators must be able to rely on them not only for normal operation, but also during abnormal conditions like black starts or adverse cyber scenarios. To that end, we study the communications, device interfaces, and potential consequences of DER operation under abnormal and adversarial conditions. The weaknesses of communications networks are studied based on the industrial protocols used, and the benefits of security features are examined. The device interfaces are found to be vulnerable to attack based on the requirements in the IEEE-1547 standard for DER interconnection and interoperability, which is expected to be adopted in the next ten years. In addition to exploring the requirements of the standard, we show that these vulnerabilities and others do exist and can be used maliciously in a modern storage system DER. Consequences of these vulnerabilities range from exacerbated grid instability, to simultaneous loss of large portions of DER penetration, to physical damage to inverters or DER themselves and other sensitive equipment. We tie these outcomes to specific attacker actions in an effort to give operators a better threat intelligence view that allows them to prioritize mitigations. Finally, we discuss mitigations that could prevent many of the adversarial scenarios described. Some solutions can be added to existing infrastructure, while others may require longer term planning for grid modernization with consideration for security.

25 ENERGY STORAGE↗