Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Computer Analysis of Eye Blood-Vessel Images

Technique rapidly diagnoses diabetes mellitus. Photographs of "whites" of patients' eyes scanned by computerized image analyzer programmed to quantify density of small blood vessels in conjuctiva. Comparison with data base of known normal and diabetic patients facilitates rapid diagnosis.

Wall, R. J.↗

Generation-V dual-Purkinje-image eyetracker

Major advances characterize the Generation-V dual-Purkinje-image eyetracker compared with the Generation-III version previously described. These advances include a large reduction in size, major improvements in frequency response and noise level, automatic alignment to a subject, and automatic adjustment for different separation between the visual and optic axes, which can vary considerably from subject to subject. In a number of applications described in the paper, the eyetracker is coupled with other highly specialized optical devices. These applications include accurately stabilizing an image on a subject's retina; accurately simulating a visually dead retinal region (i.e., a scotoma) of arbitrary shape, size, and position; and, for clinical purposes, stabilizing the position of a laser coagulator beam on a patient's retina so that the point of contact is unaffected by the patient's own eye movements.

Crane, H. D.↗

Implantable, Ingestible Electronic Thermometer

Small quartz-crystal-controlled oscillator swallowed or surgically implanted provides continuous monitoring of patient's internal temperature. Receiver placed near patient measures oscillator frequency, and temperature inferred from previously determined variation of frequency with temperature. Frequency of crystal-controlled oscillator varies with temperature. Circuit made very small and implanted or ingested to measure internal body temperature.

Kleinberg, Leonard↗

Operational medicine in Space Station era

Medical considerations for long duration manned space missions are examined. The requirements and hardware for medical operations on the Space Station are diagrammatically presented. The physiological and psychological changes that have been observed during space flights are discussed. Crew health maintenance and medical care in the Space Station environment require earth-based and in flight continuity. It is also necessary to identify the appropriate zero-G therapeutic methods for treating a patient. Techniques for transferring patients in orbit and to earth are studied. Considerations are given to control and life support systems and data management for medical operations.

Furukawa, S.↗

Implanted Blood-Pressure-Measuring Device

Arterial pressure compared with ambient bodily-fluid pressure. Implanted apparatus, capable of measuring blood pressure of patient, includes differential-pressure transducer connected to pressure sensor positioned in major artery. Electrical signal is function of differential pressure between blood-pressure sensor and reference-pressure sensor transmitted through skin of patient to recorder or indicator.

Fischell, Robert E.↗

Programmable Cadence Timer

Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.

Hall, William A.↗

Quasi-conformal remapping for compensation of human visual field defects - Advances in image remapping for human field defects

Image coordinate transformations are investigated for possible use in a low vision aid for human patients. These patients typically have field defects with localized retinal dysfunction predominately central (age related maculopathy) or peripheral (retinitis pigmentosa). Previously simple eccentricity-only remappings which do not maintain conformality were shown. Initial attempts on developing images which hold quasi-conformality after remapping are presented. Although the quasi-conformal images may have less local distortion, there are discontinuities in the image which may counterindicate this type of transformation for the low vision application.

Juday, Richard D.↗

Designing a training tool for imaging mental models

The training process can be conceptualized as the student acquiring an evolutionary sequence of classification-problem solving mental models. For example a physician learns (1) classification systems for patient symptoms, diagnostic procedures, diseases, and therapeutic interventions and (2) interrelationships among these classifications (e.g., how to use diagnostic procedures to collect data about a patient's symptoms in order to identify the disease so that therapeutic measures can be taken. This project developed functional specifications for a computer-based tool, Mental Link, that allows the evaluative imaging of such mental models. The fundamental design approach underlying this representational medium is traversal of virtual cognition space. Typically intangible cognitive entities and links among them are visible as a three-dimensional web that represents a knowledge structure. The tool has a high degree of flexibility and customizability to allow extension to other types of uses, such a front-end to an intelligent tutoring system, knowledge base, hypermedia system, or semantic network.

Dede, Christopher J.↗

The QT interval in lightning injury with implications for the cessation of metabolism hypothesis

An hypothesis is presented to provide an alternative to the Cessation of Metabolism hypothesis often invoked in lightning injury. Cessation of Metabolism has been proposed to explain the observation of good recovery after a prolonged period in cardiac arrest in some lightning injured patients. Reevaluation of EEGs from lightning injured patients show a high incidence of QT prolongation. Reexamination of the cases used to support Cessation of Metabolism also reveals little evidence to justify the hypothesis. The finding of QT prolongation coupled with the hyperadrenergic state said to exist in lightning injury, may promote a state of episodic induction of and recovery from Torsade de Pointes Ventricular Tachycardia (VT). Histological examination of the myocardium supports the new hypothesis. This the first concerted description of lightning injury as one of the general causes of QT prolongation. It appears to occur frequently after lightning injury, is a prerequisite of and predisposes to episodes of Torsade de Pointes VT. These electrocardiographic abnormalities explain Cessation of Metabolism and recognition may change management and lead to greater survival.

Andrews, Christopher J.↗

Signal processing methodologies for an acoustic fetal heart rate monitor

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.

Pretlow, Robert A., III↗

Cerebral specialization

The concept of greater performance efficiency for certain mental abilities or processes in one cerebral hemisphere rather than the other is referred to as 'cerebral lateralization'. The experimental paradigm for lateralization research involves the study of patients with one damaged hemisphere, which prevents their performance of a certain task or function; this approach, however, presents many difficulties in extrapolating to brain function in normal patients. Attention is presently given to gender differences in lateralization, cerebral asymmetries in other species, and the evolutionary bases of hemispheric specialization.

Morris, Robin D.↗

Determining the IV fluids required for a ten day medical emergency on Space Station Freedom - Comparison of packaged vs. on-orbit produced solutions

To aid planning for the storage of supplies onboard Space Station Freedom, an estimate was made of the amount of intravenous (IV) fluid required to support a patient who has suffered a medical emergency for a period of up to 10 days. Six different medical scenarios were evaluated, and the volume of IV fluids required for each scenario was estimated. Up to 220 liters of fluid would be required to support a patient for all of the scenarios. When optimizing the volumes to support any single scenario, a total of 123 liters is required. Use of a water polishing system to produce sterile water for injection from potable supplies and on-station formulation of IV fluids results in a smaller mass and volume requirement for the Fluid Therapy Subsystem than carrying prepackaged bags of fluid.

Creager, Gerald J.↗

A three channel telemetry system

A three channel telemetry system intended for biomedical applications is described. The transmitter is implemented in a single chip using a 2 micron BiCMOS processes. The operation of the system and the test results from the latest chip are discussed. One channel is always dedicated to temperature measurement while the other two channels are generic. The generic channels carry information from transducers that are interfaced to the system through on-chip general purpose operational amplifiers. The generic channels have different bandwidths: one from dc to 250 Hz and the other from dc to 1300 Hz. Each generic channel modulates a current controlled oscillator to produce a frequency modulated signal. The two frequency modulated signals are summed and used to amplitude modulate the temperature signal which acts as a carrier. A near-field inductive link telemeters the combined signals over a short distance. The chip operates on a supply voltage anywhere from 2.5 to 3.6 Volts and draws less than 1 mA when transmitting a signal. The chip can be incorporated into ingestible, implantable and other configurations. The device can free the patient from tethered data collection systems and reduces the possibility of infection from subcutaneous leads. Data telemetry can increase patient comfort leading to a greater acceptance of monitoring.

Lesho, Jeffery C.↗

Automatic Detection of Seizures with Applications

There are an estimated two million people with epilepsy in the United States. Many of these people do not respond to anti-epileptic drug therapy. Two devices can be developed to assist in the treatment of epilepsy. The first is a microcomputer-based system designed to process massive amounts of electroencephalogram (EEG) data collected during long-term monitoring of patients for the purpose of diagnosing seizures, assessing the effectiveness of medical therapy, or selecting patients for epilepsy surgery. Such a device would select and display important EEG events. Currently many such events are missed. A second device could be implanted and would detect seizures and initiate therapy. Both of these devices require a reliable seizure detection algorithm. A new algorithm is described. It is believed to represent an improvement over existing seizure detection algorithms because better signal features were selected and better standardization methods were used.

Olsen, Dale E.↗

Optimal sampling theory and population modelling - Application to determination of the influence of the microgravity environment on drug distribution and elimination

The optimal sampling theory is evaluated in applications to studies related to the distribution and elimination of several drugs (including ceftazidime, piperacillin, and ciprofloxacin), using the SAMPLE module of the ADAPT II package of programs developed by D'Argenio and Schumitzky (1979, 1988) and comparing the pharmacokinetic parameter values with results obtained by traditional ten-sample design. The impact of the use of optimal sampling was demonstrated in conjunction with NONMEM (Sheiner et al., 1977) approach, in which the population is taken as the unit of analysis, allowing even fragmentary patient data sets to contribute to population parameter estimates. It is shown that this technique is applicable in both the single-dose and the multiple-dose environments. The ability to study real patients made it possible to show that there was a bimodal distribution in ciprofloxacin nonrenal clearance.

Drusano, George L.↗

Telemedicine and international disaster response: Medical consultation to Armenia and Russia via a telemedicine spacebridge

The Telemedicine Spacebridge, a satellite mediated audio-video-fax link between four U.S. and two Armenian and Russian medical centers, permitted remote American consultants to assist Armenian and Russian physicians in the management of medical problems following the December 1988 earthquake in Armenia and the June 1989 gas explosion near Ufa. During 12 weeks of operations, 247 Armenian and Russian and 175 American medical professionals participated in 34 half-day clinical conferences. 209 patients were discussed, requiring expertise in 20 specialty areas. Telemedicine consultations resulted in altered diagnoses for 54, new diagnostic studies for 70, altered diagnostic processes for 47, and modified treatment plans for 47 of 185 Armenian patients presented. Simultaneous participation of several U.S. medical centers was judged beneficial; quality of data transmission was judged excellent. These results suggest that interactive consultation by remote specialists can provide valuable assistance to onsite physicians and favorably influence clinical decisions in the aftermath of major disasters.

Houtchens, Bruce A.↗

Clinical aspects of telemedicine

Communication among physicians is an essential in order to combine our experiences for the elucidation and application of new knowledge and for the accurate and uniform application of established medical practice. This communication requires an adequate understanding of the culture of the patient and the social context of disease and indeed the culture of the physician. Malnutrition in Bangladesh means caloric insufficiency, and a program to lower cholesterol would be impertinent, while a program to enhance the nutrition of patients in Texas by an international effort to import more grain would be ludicrous. In the same vein a public health effort to combat alcoholic cirrhosis in Mecca would be as silly as a program to increase fiber in the diet of the Bantu. Clinical communication must acknowledge the culture of the issue at hand and the differences in the experiential base of the physicians. Not only do geography and culture affect the potential differences in the experiential bases, but the world utilizes very different traditions of education and science in training physicians. We are influenced by the diseases we treat, and learn to look for the expected at least as much as we are attentive to the unexpected. A physician in Siberia would be much more likely to recognize frostbite than one from Buenos Aires, and the Argentine doctor would much more likely consider Chaga's Disease to explain abdominal pain than a colleague in Zurich. Beyond these obvious issues in communication among physicians we must deal with the many languages and idioms used in the world. An overview of using Telemedicine SpaceBridge after the earthquake in the Republic of Armenia in 1988 is presented.

Merrell, Ronald C.↗

A telemedicine health care delivery system

The Interactive Telemedicine Systems (ITS) system was specifically developed to address the ever widening gap between our medical care expertise and our medical care delivery system. The frustrating reality is that as our knowledge of how to diagnose and treat medical conditions has continued to advance, the system to deliver that care has remained in an embryonic stage. This has resulted in millions of people being denied their most basic health care needs. Telemedicine utilizes an interactive video system integrated with biomedical telemetry that allows a physician at a base station specialty medical complex or teaching hospital to examine and treat a patient at multiple satellite locations, such as rural hospitals, ambulatory health centers, correctional institutions, facilities caring for the elderly, community hospital emergency departments, or international health facilities. Based on the interactive nature of the system design, the consulting physician at the base station can do a complete history and physical examination, as if the patient at the satellite site was sitting in the physician's office. This system is described.

Sanders, Jay H.↗