Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Neurofibromatosis Type 1: Transcatheter Arterial Embolization for Ruptured Occipital Arterial Aneurysms

Two cases of ruptured aneurysms in the posterior cervical regions associated with type-1 neurofibromatosis treated by transcatheter embolization are reported. Patients presented with acute onset of swelling and pain in the affected areas. Emergently performed contrast-enhanced CT demonstrated aneurysms and large hematomas widespread in the posterior cervical regions. Angiography revealed aneurysms and extravasations of the occipital artery. Patients were successfully treated by percutaneous transcatheter arterial microcoil embolization. Transcatheter arterial embolization therapy was found to be an effective method for treating aneurysmal rupture in the posterior cervical regions occurring in association with type-1 neurofibromatosis. A literature review revealed that rupture of an occipital arterial aneurysm, in the setting of neurofibromatosis type 1, has not been reported previously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PTA of Infrapopliteal Arteries: Long-term Clinical Follow-up and Analysis of Factors Influencing Clinical Outcome

This study was a retrospective analysis of patients with CLI who underwent infrapopliteal percutaneous transluminal angioplasty (PTA). The main goal was to evaluate clinical and morphological factors that influence the clinical outcome of PTA in long-term follow-up. A total of 1,445 PTA procedures were performed in 1,268 patients. Main indications for PTA included gangrene, nonhealing ulcers, or rest pain. The mean number of treated arteries was 1.77 artery/limb, and the majority of lesions were type TASC D. The technical success rate of PTA was 89% of intended-to-treat arteries. The main criterion of clinical success was functional limb salvage (LS). One-year follow-up involved 1,069 limbs. Primary and secondary 1-year LS rates were 76.1 and 84.4%, respectively. The effect of clinical and morphological parameters on the 1-year LS was that the only associated disease with an adverse effect on LS rate was DM combined with dialysis. Regarding limb preprocedural status, gangrene was clearly a negative predictor. The most important factor affecting LS was the number of patent arteries post-PTA: patients with 0, 1, 2, and 3 patent arteries had 1-year primary LS rates of 56.4, 73.1, 80.4, and 83%, respectively. Long-term follow-up of LS rates demonstrated secondary LS rates of 84.4, 78.8, and 73.3% at 1, 5, and 10 years. Every effort should be made to perform PTA for as many arteries as possible, even if TASC D type, to improve clinical outcome. Our study shows that repeat PTA is capable of keeping the long-term LS rate close to 75%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Osteoid Osteoma: Initial Experience with a New Monopolar Ablation Device

The purpose of this article is to report our initial experience with the 'off-label' use of a new monopolar radiofrequency (RF) probe for percutaneous ablation of osteoid osteomas. Seventeen patients (12 male and 5 female, mean age 24.8 [range 9-49]) with osteoid osteoma were treated by computed tomography (CT)-guided RF ablation (RFA). All procedures were performed with the patient under general aesthesia. After localization of the nidus, a 13G hollow drill was introduced into the nidus through a 7F introducer sheath. A monopolar 16.5G RF probe with a 9-mm active tip (Soloist; Boston Scientific, Natick, MA) was inserted through the introducer sheath and connected to the RF generator. Energy application was started at 2 W and subsequently increased every 2 min by 1 W to a maximum of 8 W. The procedure ended if impedance increased by 500 Ohm-Sign . Mean duration of energy deposition was 14.2 {+-} 3.3 min. Fourteen of 17 patients (82%) were free of symptoms at 29.9 {+-} 14.8 (range 4 to 47) months of follow-up. The primary and secondary success rates were 83% and 100%, respectively. In 3 patients, recurrence of pain at 6 (n = 1) and 15 (n = 2) months after the initial procedure was successfully treated by reablation. There were no complications. Monopolar RFA using the Soloist probe is effective and safe for the treatment of osteoid osteoma. It results in comparable success rates as other monopolar or bipolar RF systems in the treatment of osteoid osteoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior Mesenteric Artery Embolism Treated with Percutaneous Mechanical Thrombectomy

A case of acute superior mesenteric artery embolism treated with percutaneous thrombus aspiration is described. A 63-year-old man with chronic atrial fibrillation was admitted to the hospital with progressive abdominal pain. Computed tomography angiography revealed an occlusion of the distal part of the superior mesenteric artery. The patient was effectively treated using transaxillary percutaneous mechanical thrombectomy using a 6F Aspirex thrombectomy catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot Study

Purpose: To evaluate the accuracy and technical success of positioning a radiofrequency ablation (RFA) electrode in osteoid osteomas by use of a new real-time needle guidance technology combining cone-beam computed tomography (CT) and fluoroscopy. Materials and Methods: Percutaneous RFA of osteoid osteomas was performed in five patients (median age 18 years), under general anesthesia, with the use of cone-beam CT and fluoroscopic guidance for electrode positioning. The outcome parameters were technical success, meaning correct needle placement in the nidus; accuracy defined as the deviation (in mm) from the center of the nidus; and clinical outcome at follow-up. Results: In all five cases, positioning was possible within 3 mm of the determined target location (median nidus size 6.8 mm; range 5-10.2 mm). All procedures were technically successful. All patients were free of pain at clinical follow-up. No complications were observed. Conclusion: Real-time fluoroscopy needle guidance based on cone-beam CT is a useful tool to accurately position radiofrequency needles for minimally invasive treatment of osteoid osteomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measured 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kummel Disease Treatment by Unipedicular Vertebral Augmentation Using Curved Injection Cannula

Purpose: This study was designed to evaluate the efficacy of the blunt-tipped curved injection needle (BCN) AVAflex (Care Fusion) for vertebral augmentation in cases of Kummel's disease. Methods: We performed 25 vertebral augmentation procedures on 25 consecutive patients (11 men/14 women; mean age, 67 years) with Kummel's disease using the blunt-tipped curved injection needle with PMMA cement. We performed all 25 procedures by unipedicular left approach with patients in prone position under local anesthesia and mild sedation. In all cases, an intravertebral cleft was evident on preprocedural imaging. We evaluated pain intensities by Visual Analogic Scale (VAS) before and at first day, 6 months, and 1 year after procedure. Results: In all cases the curved injection cannula permitted the filling of the clefts and surrounding cancellous bone without any complication. A significant reduction of kyphotic deformities of the treated vertebral bodies was evident. A significance decrease in VAS values at 1 year also was evident (mean decrease 7.2). At plain dynamic postprocedural X-rays checks, there was no sign of pathologic intravertebral motion as evidence of optimal stabilization. Conclusions: BCN AVAflex is a safe and effective device for targeted vertebral augmentation in cases of Kummel's disease. Its distinctive characteristic is the curved injection cannula, which enables targeting the cement injection to areas far off the trajectory of the straight access cannula, thus providing excellent cement spread throughout the entire volume of vertebral body.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Thrombolysis and Spasmolysis of Acute Leg Ischemia after Accidental Intra-arterial Injection of Dissolved Flunitrazepam Tablets

A 37-year-old man with known intravenous drug abuse presented in the surgical ambulatory care unit with acute leg ischemia after accidental intra-arterial injection of dissolved flunitrazepam tablets into the right femoral artery. A combination of anticoagulation, vasodilatation, and local selective and superselective thrombolysis with urokinase was performed to salvage the leg. As a result of the severe ischemia-induced pain, the patient had to be monitored over the complete therapy period on the intensive care unit with permanent administration of intravenous fluid and analgetics. We describe the presenting symptoms and the interventional technique, and we discuss the recent literature regarding the management of accidental intra-arterial injection of dissolved flunitrazepam tablets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Stabilization of Impending Pathological Fracture of the Proximal Femur

Objective: Percutaneous osteosynthesis plus cementoplasty (POPC) is a minimally invasive technique that has never been reported before and that we have prospectively evaluated for patients with impending pathological fracture of the proximal femur. Methods: We performed POPC in 12 patients (3 males, 9 females) with metastasis of the proximal femur with a high risk of fracture (Mirels' score {>=}8) between February 2010 and July 2011. Patients were not candidates for standard surgical stabilization. We analyzed the feasibility, duration, and complication of the procedure, the risk of fracture, the decrease in pain (Visual Analog Scale, VAS), and length of stay in hospital. Data were prospectively collected in all patients. Results: The mean Mirels' score was 9.8 {+-} 1.2 (range, 8-11). The technical success was 100%. POPC was performed under general anesthesia (n = 6) or conscious sedation (n = 6). The mean duration was 110 {+-} 43 (range, 60-180) minutes. All patients stood up and walked the second day after the procedure. The average length of stay in the hospital was 4 {+-} 1.6 (range, 2-7) days. We experienced two hematomas in two patients and no thromboembolic complication. For symptomatic patients (n = 8), VAS decreased from 6.5/10 (range, 2-9) before treatment to 1/10 (range, 0-3) 1 month after. No fracture occurred after a median follow-up of 145 (range, 12-608) days. Conclusions: POPC for impending pathological fracture of the proximal femur seems to be a promising alternative for cancer patients who are not candidates for surgical stabilization. Further studies are required to confirm this preliminary experience.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receive an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiology of Male Varicocele: Current Status

Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Retrograde Recanalization of the Celiac Artery by Way of the Superior Mesenteric Artery for Chronic Mesenteric Ischemia

A 52-year-old man presented with recurrent postprandial abdominal pain, sitophobia, and progressive weight loss. Chronic mesenteric ischemia (CMI) due to subtotal occlusion of the superior mesenteric artery (SMA) and flush occlusion of the celiac artery (CA) was diagnosed. Retrograde recanalization of the CA by way of a collateral channel from the SMA was performed using contemporary recanalization equipment. The CA and SMA were then stented, resulting in sustained resolution of CMI-related symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Results with the Use of Heparin-bonded Stent Graft to Rescue Failed Angioplasty of Chronic Femoropopliteal Occlusive Lesions: TASC D Lesions Have a Poor Outcome

Purpose: To evaluate early patency rate of the heparin-bonded stent grafts in atherosclerotic long femoropopliteal occlusive disease, and to identify factors that affect outcome. Methods: Heparin-bonded Viabahn stent grafts were placed in 33 limbs in 33 patients during 2009-2010. The stents were deployed to rescue failed conventional balloon angioplasty. Mean age was 69 (range 44-88) years, and 67 % (22 of 33) were men. Most procedures (21 of 33, 64 %) were performed for critical limb ischemia (33 % for rest pain, 30 % tissue loss). Kaplan-Meier plots and Cox regression analysis were used to identify significant risk factors. Results: The average length of lesions treated was 25 {+-} 10 cm, and they were predominantly TASC (Transatlantic Intersociety Consensus) D (n = 13) and C (n = 17) lesions. The median primary patency was 5.0 months (95 % confidence interval 1.22-8.77). The mean secondary patency was 8.6 months (95 % confidence interval 6.82-10.42). Subsequently, 4 patients underwent bypass surgery and 5 patients underwent major amputation. One patient died. There were 5 in-stent or edge-stent stenoses. Cox multivariate regression analysis identified TASC D lesions to be a significant risk factor for early occlusion (p = 0.035). Conclusion: TASC D lesions of femoropopliteal occlusions have poor patency rates with the use of heparin-bonded stent grafts after failed conventional angioplasty. Alternative options should be considered for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elastoplasty: First Experience in 12 Patients

Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is used increasingly for pain relief in symptomatic neoplastic or osteoporotic compression fractures. However, restoration of the stiffness of the treated vertebrae might propagate secondary fracture of adjacent vertebrae. Elastoplasty might prevent these secondary fractures. We assessed retrospectively our experience with elastoplasty in 12 patients, focusing on silicone migration. During the period from July 2011 to January 2012, all patients with an indication for vertebroplasty were treated with elastoplasty. The exclusion criterion was the presence of posterior wall defects. Chest computed tomography (CT) scans were performed to evaluate the presence of perivertebral leakage and pulmonary embolism. The prevalence of leakage was compared with the results obtained for vertebroplasty with PMMA reported in the literature. Other complications during the postprocedural period were recorded. Twenty-one vertebral bodies in 12 patients were treated with elastoplasty. Silicone pulmonary emboli were detected on the postprocedural chest CT in 60 % (6/10) of the patients. Leakage to the perivertebral venous plexus was seen in 67 % (14/21) of the treated vertebrae. One major complication occurred: severe, medication-resistant dyspnea developed in one patient with multiple peripheral silicone emboli. This preliminary evidence suggests that VK100 silicone cement should not be used in elastoplasty because of the increased risk of silicone pulmonary embolism, when compared with the use of PMMA, which occurs worldwide. The major technical disadvantage is that the time taken for the VK100 silicone material to achieve its final strength is too long for practical application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗