Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-redshift quasars along the main sequence

The 4D Eigenvector 1 empirical formalism (4DE1) and its main sequence (MS) for quasars has emerged as a powerful tool for organising the diversity among quasar populations, as several key observational measures and physical parameters are systematically changing along it. Trends revealed by 4DE1 are very well established to explain all the diverse characteristics seen in low-redshift quasar samples. Nevertheless, the situation is far less clear when dealing with high-luminosity and high-redshift sources. Here, we aim to evaluate the behaviour of our sample of 22 quasars at high redshift (2.2 ≤ z ≤ 3.7) and high luminosity (47.39 ≤ L bol ≤ 48.36) in the context of the 4DE1. Our approach involves studying quasar physics through a spectroscopic exploration of UV and optical emission line diagnostics. We used new observations from the ISAAC instrument at ESO-VLT and primarily from the SDSS to cover the optical and the UV rest-frames, respectively. The emission lines were characterised both via a quantitative parametrisation of the line profiles and a decomposition of the emission line profiles using multicomponent fitting routines. We provide spectrophotometric properties and line profile measurements for Hβ+[O III]λλ4959,5007, as well as Si IVλ1397+O IV]λ1402, C IVλ1549+He IIλ1640, and the 1900 Å blend (including Al IIIλ1860, Si III]λ1892, and C III]λ1909). For six out of the 22 objects, a significantly blueshifted component on the Hβ profile is present. In 14 out of 22 cases, an Hβ outflowing component associated with [O III] is detected. The majority of [O III]λλ4959,5007 emission line profiles show blueshifted velocities higher than 250 km s -1 . We find extremely broad [O III]λλ4959,5007 emission that is comparable to the width of Hβ broad profile in some highly accreting quasars. The [O III]λλ4959,5007 and C IVλ1549 blueshifts show very high amplitudes and a high degree of correlation. The line widths and shifts are correlated for both [O III]λλ4959,5007 and C IVλ1549, suggesting that emission from outflowing gas is providing a substantial broadening effect to both lines. Otherwise, the links between C IVλ1549 centroid velocity at half intensity (c(1/2)), Eddington ratio (L/L Edd ), and bolometric luminosity are found to be in agreement with previous studies of high-luminosity quasars. Our analysis suggests that the behaviour of quasars of very high luminosity all along the main sequence is strongly affected by powerful outflows involving a broad range of spatial scales. The main sequence correlations remain valid at high redshift and high luminosity even if a systematic increase in line width is observed. Scaling laws based on UV Al IIIλ1860 and Hβ emission lines are equally reliable estimators of M BH .

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-pitch nano-accuracy surface profiler for strongly curved X-ray mirror metrology

We present our recent research and development effort on the Multi-Pitch Nano-accuracy Surface Profiler (MPNSP). This metrology instrument is developed to characterize strongly curved X-ray mirrors proposed to achieve diffraction-limited soft X-ray focusing for scientific applications at the synchrotron beamlines. The measurement process consists of forward-and-backward scans on the test mirror surface along its tangential direction at multiple pitch angles. Our research and development in this work aim to take the challenge of measuring strongly curved X-ray mirrors with a typical total slope range ≳10 mrad, while maintaining the Root Mean Square (RMS) value of measurement repeatability and self-consistency at 50 nrad RMS level. We first introduce the mechanical design, followed by a brief review of the mathematical model and the optimization algorithm for the MPNSP technique. By detecting the rotation axis of the mirror pitch with a machine vision approach, we can determine and then reduce the vertical distance between the pitch rotation axis and the test mirror surface to a sub-mm level. In addition, we describe a practical data acquisition procedure for strongly curved X-ray mirrors with a total slope range larger than the slope measuring range of the autocollimator used in the instrument. As a result, the proposed MPNSP measurements with different mirror orientations achieve remarkable self-consistency and reproducibility of < 50 nrad RMS in slope and < 0.5 nm RMS in height.

42 ENGINEERING↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

Autonomous adaptive data acquisition for scanning hyperspectral imaging

Non-invasive and label-free spectral microscopy (spectromicroscopy) techniques can provide quantitative biochemical information complementary to genomic sequencing, transcriptomic profiling, and proteomic analyses. However, spectromicroscopy techniques generate high-dimensional data; acquisition of a single spectral image can range from tens of minutes to hours, depending on the desired spatial resolution and the image size. This substantially limits the timescales of observable transient biological processes. To address this challenge and move spectromicroscopy towards efficient real-time spatiochemical imaging, we developed a grid-less autonomous adaptive sampling method. Our method substantially decreases image acquisition time while increasing sampling density in regions of steeper physico-chemical gradients. When implemented with scanning Fourier Transform infrared spectromicroscopy experiments, this grid-less adaptive sampling approach outperformed standard uniform grid sampling in a two-component chemical model system and in a complex biological sample, Caenorhabditis elegans. We quantitatively and qualitatively assess the efficiency of data acquisition using performance metrics and multivariate infrared spectral analysis, respectively.

47 OTHER INSTRUMENTATION↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗

The Impact of Circumsolar Diffuse Radiation on the Numerical Computation and Forecasting of DNI

Weather Research and Forecasting model with solar extensions (WRF-Solar) uses the Fast All-sky Radiation Model for Solar applications (FARMS) to predict solar radiation from the forecasted atmospheric gases, aerosols, and clouds. The Beer-Bouguer-Lambert law utilized by FARMS as well as other radiative transfer models assumes Direct Normal Irradiance (DNI) is a narrow beam only covering the sun disk. This assumption is interpreted differently in solar observations by pyrheliometers where the circumsolar diffuse radiation is accounted. This study precisely computes circumsolar diffuse radiation in all-sky conditions using a radiative transfer model based on a parameterization of precomputed cloud transmittance and reflectance. The model is implemented in WRF-Solar to provide day-ahead DNI forecast in the north America. The computation and forecasting of DNI is compared with the Beer-Bouguer-Lambert law to understand the impact of circumsolar diffuse radiation.

aerosols↗

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

Efficient generation and extreme compression of multidimensional solitary states in molecular gas-filled hollow-core fibers driven by picosecond Yb lasers

We present an in-depth study on the impact of spatiotemporal Raman enhancement in molecular gas-filled hollow-core fibers (HCFs), demonstrating the efficient generation and post-compression of multidimensional solitary states (MDSS). Through different experimental scenarios—employing large-core HCFs filled with molecular gases (N 2 and N 2 O) and driven by high energy, sub-picosecond and picosecond Fourier transform-limited ytterbium laser pulses—this work leverages multimode propagation and enhanced spatiotemporal interactions to achieve significant spectral broadening and asymmetric redshift, contrasting sharply with self-phase modulation. Our findings reveal that, beyond the regime of maximum nonadiabatic molecular alignment, spatiotemporal nonlinear enhancement primarily governs spectral broadening for input pulse durations up to 1 ps. The process shows limited sensitivity to input pulse duration and the two investigated molecular gases (N 2 and N 2 O), with only subtle differences in broadening arising from their distinct Raman spectroscopic properties. Furthermore, post-compression of MDSS was achieved in various cases. Notably, using 7 mJ, 1 ps laser pulses, we generated 22 fs pulses with a 47% energy conversion efficiency of the input pulse energy. These results position MDSS as a powerful platform for generating high-energy, ultrashort pulses with tunable wavelengths, offering a robust solution for applications such as high harmonic generation.

47 OTHER INSTRUMENTATION↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Aerosol Optical Depth Best Estimate Value-Added Product Report

Four aerosol optical depth (AOD) products are offered by four collocated ground-based instruments deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory (SGP Central Facility 1 [C1] and Extended Facility 13 [E13]) for more than two decades. Two of these instruments, the multifilter rotating shadowband radiometers (MFRSRs C1 and E13), are sensors with horizontal hemispherical receivers shaded by rotating shadowbands.

47 OTHER INSTRUMENTATION↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗