Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Optical monitoring system

Instrument can measure optical transmission, reflectance, and scattering. This information can be used to identify changes in optical properties or deviations from required optical standards. Device consists of monochromatic source, photo detector, transfer mirror, and hemiellipsoid. System might be used to measure optical properties of thin film.

Nev, J. T.↗

Soft X-ray astronomy using grazing incidence optics

The instrumental background of X-ray astronomy with an emphasis on high resolution imagery is outlined. Optical and system performance, in terms of resolution, are compared and methods for improving the latter in finite length instruments described. The method of analysis of broadband images to obtain diagnostic information is described and is applied to the analysis of coronal structures.

Davis, John M.↗

New optical scheme for a polarimetric-based glucose sensor

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Evaluation Studies↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Nasa Space Flight Instruments: Cost Time Trends

Are NASA’s space flight instruments becoming cheaper or more expensive as time marches forward? After analyzing the costs of hundreds of instruments launched over the last 30 years, the short answer to this question is no… and yes. This paper gives a visual analysis of the cost time trends for various NASA space flight instrument types, such as optical, particles detectors, fields detectors and microwave instruments. In addition to the statistical approaches utilized, such as significance tests, cluster analysis and principle components analysis (PCA), we will also discuss the intangibles which are likely at play, including technological progress, NASA policy and the luck of the draw associated with mission manifests. This analysis was performed as the main driver for the NASA Instrument Cost Model (NICM) recent cost estimating model redesign. Started in 2004, the first version of NICM was based off of instruments launched from 1985-2005, or 20 years’ worth of data. As NICM hit its 10-year anniversary, we wanted to know: should NICM continue to only use the most recent 20 years’ worth of data (1995-2015)? Are instruments becoming cheaper or more expensive as time marches forward? There is evidence in favor of a drop in the median dollar-per-kg value across some instrument types, but little in others. Whereas further research is needed to substantiate, Particles and Optical-Planetary instrument types show moderate to strong evidence of a downward trend in dollar-per-kg. Further research is required to study the nature of this trend (shift, taper, cyclic, etc.). Little evidence for a similar downward trend was detected for Fields or Microwave instruments, or Optical instruments on Earth Orbiting spacecraft. We presented evidence in favor of a drop in the median dollar-per-kg value for Particles and Optical-Planetary instrument types. While similar evidence was weak at best for Fields and Microwave instruments. We can speculate as to the causes for this effect, but we are also equipped to begin to rule out, or at least prioritize, some of the suspected drivers. We observed, for Particles and Optical-Planetary instruments, that perhaps a launch manifest effect was playing part of the role in the observed decrease in dollar-per-kg over the years, noting that the more flagship class missions, which have more money to spend on their instruments, were seen in the earlier years in our data, versus the later years which were dominated by less expensive class missions. However, if this were a dominating driver, would we not have seen the downward trend in the Fields and Microwave instruments as well, which were drawn from that same launch manifest? The fact that we did not observe this helps us rule out the launch manifest effect, and other drivers, such as advances in technology, that seem to be more likely suspects. In that case, however, why would technology advances be helping the Particles and Optical-Planetary instruments only? Why would it not be impacting Optical-Earth Orbiting instruments? Further suspects were looked at as well and ruled out, such as the “Faster, Better, Cheaper”era of NASA development which did not seem to actually impact trends by instrument type on a dollar-perkg scale. VI. Future Work A. Time Series Detailed Statistical Assessment The analysis discussed above sets the foundation for a more rigorous time series analysis of the data. Time series analysis will further explore evidence to-date of time trends for the instrument types which showed the strongest indicators for a decrease in dollar-per-kg: Optical (Planetary) and Particles instruments. More than providing evidence and top-level significance tests, time series analysis would help elucidate what kind of trend that exists in the data, their significance and allow statistically based forecasting (see Figure 10)

Mrozinksi, Joseph↗

In Situ identification of mineral resources with an X-ray-optical "Hand-Lens" instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56).

Marshall, J.↗

Off-Nominal Planning for the Cryogenic Vacuum Test of the JWST Optical Telescope Element/Integrated Science Instrument Module at JSC

The cryogenic thermal vacuum/thermal balance test of the James Webb Space Telescope (JWST) combined Optical Telescope Element (OTE)/Integrated Science Instrument Module (ISIM), known as the OTIS, at the Johnson Space Center (JSC) Chamber A in 2017 was likely the most complex test ever performed by NASA for an unmanned mission. The test of the combined flight Optical Telescope and ISIM elements was prefaced by years of modifications to chamber facilities, and included three extensive precursor tests of non-flight and flight hardware to establish safe and optimal test operational procedures. One critical part of the test preparation was planning for off-nominal events that could arise, including appropriate responses. In some cases, assurance of personnel and payload safety required modification of original test hardware and procedures which had to be validated before the final test could begin. This planning proved especially prescient for the OTIS test, as Hurricane Harvey struck the Houston area during the test in August 2017, and consequences for the precious payload could have been severe. This paper describes the extent of the thermal off-nominal planning undertaken for the OTIS test, including including safing for hurricanes, and some real-life effects of Hurricane Harvey on the test conduct. Documentation of the consequences and mitigations for these events are discussed. The importance of off-nominal planning for future thermal vacuum/thermal balance tests is illustrated.

Off-Nominal Planning↗

Optical gyroscope

Instrument uses phase difference between two beams of light to measure rotation. It is considerably simpler and more reliable than conventional spinning-mass gyroscopes used for inertial guidance and is more compact, lighter, and potentially less expensive. Moreover, optical gyroscope requires no warmup period. Although conceived for spacecraft and satellite stabilization, gyroscope should also find applications in flight instruments for private, commercial, and military aircraft.

Goldstein, R. M.↗

Two-laser optical distance-measuring instrument that corrects for the atmospheric index of refraction.

The Wave Propagation Laboratory of the Environmental Research Laboratories of the National Oceanic and Atmospheric Administration has been engaged in the development of dual-wavelength, optical distance-measuring instruments. Recently a new generation of this type of high-accuracy instrument has been completed. Preliminary testing of the new instrument indicates that the original goal of the project, accuracy of better than one part in a million over distances of 5-10 km using averaging times of less than 1 min, is being met. This paper describes the instrument and preliminary test results.

Earnshaw, K. B.↗

Long-Lived Linear-Motion Suspension For Cryogenic Instrument

Mechanism suspends optical component in cryogenic instrument in such way to allow component to translate smoothly along one axis, without vibration. Bearings located outside cooled instrument chamber for longer life. Thermal isolators separate bearings from cryogenic environment inside instrument chamber.

Packard, Douglas T.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Optical infrared sky survey instrumentation

An unusual, highly modified, Baker reflector-corrector class telescope has been adapted for wide field survey photography in the near infrared. This optical system uses a full field corrector plate and a field flattening lens to provide a flat field subtending about 4.5 deg on the sky. The small aperture telescope (20 inch primary) has been modified for use in the Newtonian focus configuration while preserving the optical elements of the Prime focus configuration. The telescope has been further modified to accept a very large format (146mm diameter photocathode) image intensifier camera to serve as a detector. The camera output is recorded photographically on film rather than glass plates. This unique instrument system is used in a program of sky survey photography in the optical infrared (8000-9000A bandpass) supplemented by visual bandpass photography. The photographs obtained with this system are of value not only for the extreme redness of the band but also because of their high resolution and their freedom from hydrogen emission.

Craine, E. R.↗

NASA/JPL study on optical imaging interferometry in space

The overall instrument morphology, optical design, structural configurations, and control and systems design for spaceborne optical interferometry are discussed. Launch stowage and on-orbit deployment considerations favor a Very Large Array Y-configuration, shuttle launched.

Synnott, S. P.↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

thermal vacuum↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

molecular adsorber coating↗