Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Molecular beam epitaxy engineered III-V semiconductor structures for low-power optically addressed spatial light modulators

Device approaches are investigated for optically addressed SLMs based on molecular-beam epitaxy (MBE) engineered III-V materials and structures. Strong photooptic effects can be achieved in periodically delta-doped multiple-quantum-well structures, but are still insufficient for high-contrast modulation with only single- or double-pass absorption through active layers of practical thickness. The asymmetric Fabry-Perot cavity approach is employed to permit extinction of light due to interference of light reflected from the front and back surfaces of the cavity. This approach is realized with an all-MBE-grown structure consisting of GaAs/AlAs quarter-wave stack reflector grown over the GaAs substrate as the high reflectance mirror and the GaAs surface as the low reflectance mirror. High-contrast modulation is achieved using a low-power InGaAs/GaAs quantum well laser for the control signal.

Larsson, Anders G.↗

Modulation improves electro-optic object detector

Device as part of integrated circuit protection line is used to detect presence or absence of silicon wafer at point along air track. System is insensitive to ambient light and electrical noise, requires no special components or adjustments, operates from single supply source, and is relatively inexpensive to build.

Currie, J. R.↗

Dynamic response tests of inertial and optical wind-tunnel model attitude measurement devices

Results are presented for an experimental study of the response of inertial and optical wind-tunnel model attitude measurement systems in a wind-off simulated dynamic environment. This study is part of an ongoing activity at the NASA Langley Research Center to develop high accuracy, advanced model attitude measurement systems that can be used in a dynamic wind-tunnel environment. This activity was prompted by the inertial model attitude sensor response observed during high levels of model vibration which results in a model attitude measurement bias error. Significant bias errors in model attitude measurement were found for the measurement using the inertial device during wind-off dynamic testing of a model system. The amount of bias present during wind-tunnel tests will depend on the amplitudes of the model dynamic response and the modal characteristics of the model system. Correction models are presented that predict the vibration-induced bias errors to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment. The optical system results were uncorrupted by model vibration in the laboratory setup.

Buehrle, R. D.↗

Solid-state data interpretation system - A concept

Device, serving as substitute for cathode ray tubes, applies to computer input-output devices such as microfilm readers, data displays, and optical scanners. Each device operates at speed of modern computer.

Hagenau, K.↗

A survey of integrated optics with bibliography

The field of integrated optics is surveyed. Light coupling into films, modulation of light propagating in films, and current integrated optics developments and devices are discussed. It is concluded that integrated optics technology is expected to revolutionize the electronics industry as completely as did microcircuit technology. An extensive bibliography for the field of integrated optics is included.

Owen, R. B.↗

Conceptual design of an on-board optical processor with components

The specification of components for a spacecraft on-board optical processor was investigated. A space oriented application of optical data processing and the investigation of certain aspects of optical correlators were examined. The investigation confirmed that real-time optical processing has made significant advances over the past few years, but that there are still critical components which will require further development for use in an on-board optical processor. The devices evaluated were the coherent light valve, the readout optical modulator, the liquid crystal modulator, and the image forming light modulator.

Walsh, J. R.↗

The integrated optic RF spectrum analyzer

The results of measurements made on a fully integrated optic RF spectrum analyzer (IOSA) are reported. The performance of the device acousto-optic bandwidth, single-tone RF resolution, two-tone RF resolution, single-tone dynamic range, two-tone dynamic range, and single-tone RF response are presented. The device parameters that control device performance are analyzed. These results demonstrate the viability of the IOSA for real time spectrum analysis of pulsed and CW RF signals. Improvements of RF bandwidth resolution can be obtained by the use of larger collimated optical beams which requires larger optical lens elements, and hence, larger crystals.

Pedinoff, M. E.↗

Automatic quadrature control and measuring system

A quadrature component cancellation and measuring system comprising a detection system for detecting the quadrature component from a primary signal, including reference circuitry to define the phase of the quadrature component for detection is described. A Raysistor optical coupling control device connects an output from the detection system to a circuit driven by a signal based upon the primary signal. Combining circuitry connects the primary signal and the circuit controlled by the Raysistor device to subtract quadrature components. A known current through the optically sensitive element produces a signal defining the magnitude of the quadrature component.

Hamlet, J. F.↗

Space Qualification Studies of AOTF Devices Under the MISSE-11 Mission

The acousto-optic tunable filter (AOTF) devices are used in a variety of applications including hyperspectral and spectrapolarimetric based imaging. The AOTF devices provide several advantages including speed and random access to desired spectral bands and enable all-solid-state operation that are attractive for space applications. In this paper, the performance of Tellurium Dioxide (TeO 2 ) and Mercurous Bromide (Hg 2 Br 2 ) AOTF devices in space environment carried out under the NASA’s Materials International Space Station Experiments 11 (MISSE-11) mission is discussed. The purpose of the MISSE-11 mission was to study materials and devices subjected to space conditions for long term while attached to the International Space station (ISS). The TeO 2 AOTF was developed for short wavelength IR (SWIR) operation while the Hg 2 Br 2 AOTF device was developed for long wavelength IR (LWIR) operation. These devices were attached to the ISS platform for more than a year. Pre-flight and post-flight performance characterization were performed on these devices. In the case of TeO 2 AOTF, the preflight efficiency was around 87% with a center frequency at 68MHz while the post-flight efficiency was around 83%. However, the optical transmission of Hg 2 Br 2 AOTF had deteriorated considerably. The details of performance testing and analysis of both AOTF devices are discussed.

Space Qualification↗

Growth and Characterization of III-V Semiconductors for Device Applications

The research goal was to achieve a fundamental understanding of the physical processes occurring at the surfaces and interfaces of epitaxially grown InGaAs/GaAs (100) heterostructures. This will facilitate the development of quantum well devices for infrared optical applications and provide quantitative descriptions of key phenomena which impact their performance. Devices impacted include high-speed laser diodes and modulators for fiber optic communications at 1.55 micron wavelengths and intersub-band lasers for longer infrared wavelengths. The phenomenon of interest studied was the migration of indium in InGaAs structures. This work centered on the molecular beam epitaxy reactor and characterization apparatus donated to CAU by AT&T Bell Laboratories. The material characterization tool employed was secondary ion mass spectrometry. The training of graduate and undergraduate students was an integral part of this program. The graduate students received a thorough exposure to state-of-the-art techniques and equipment for semiconductor materials analysis as part of the Master''s degree requirement in physics. The undergraduates were exposed to a minority scientist who has an excellent track record in this area. They also had the opportunity to explore surface physics as a career option. The results of the scientific work was published in a refereed journal and several talks were presented professional conferences and academic seminars.

Williams, Michael D.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Miniature laser ignited bellows motor

A miniature optically ignited actuation device has been demonstrated using a laser diode as an ignition source. This pyrotechnic driven motor provides between 4 and 6 lbs of linear force across a 0.090 inch diameter surface. The physical envelope of the device is 1/2 inch long and 1/8 inch diameter. This unique application of optical energy can be used as a mechanical link in optical arming systems or other applications where low shock actuation is desired and space is limited. An analysis was performed to determine pyrotechnic materials suitable to actuate a bellows device constructed of aluminum or stainless steel. The aluminum bellows was chosen for further development and several candidate pyrotechnics were evaluated. The velocity profile and delivered force were quantified using an non-intrusive optical motion sensor.

Renfro, Steven L.↗

Optical-data-processing properties of a liquid-crystal television spatial light modulator

The potential of an extremely inexpensive liquid-crystal television (LCTV) as a two-dimensional spatial light modulator has been investigated. The LCTV modulates the transmission of coherent or incoherent light and can either be electronically addressed through a microcomputer or optically addressed with a TV camera. The transmission characteristics of the device have been measured, its diffraction pattern is examined, and its use as an input device for an optical correlator is tested. It is discovered that, with proper modifications, it has potential for optical-data-processing applications.

Liu, H.-K.↗

User-Wearable Devices that Monitor Exposure to Blue Light and Recommend Adjustments Thereto

Described herein are user-wearable devices that include an optical sensor, and methods for use therewith. In certain embodiments, an optical sensor of a user-wearable device (e.g., a wrist-worn device) is used to detect blue light that is incident on the optical sensor and to produce a blue light detection signal indicative thereof, and thus, indicative of the response of the user's intrinsically photosensitive Retinal Ganglion Cells (ipRGCs). In dependence on the blue light detection signal, there is a determination of a metric indicative of an amount of blue light detected by the optical sensor. The metric is compared to a corresponding threshold, and a user notification is triggered in dependence on results of the comparing, wherein the user notification informs a person wearing the user-wearable device to adjust their exposure to light.

Lee, Yong Jin↗

Optical flameout detector

A device has been developed which monitors the presence of a flame within a combustion chamber. The optical flameout detection system responds to gross changes in combustor light intensity, which is monitored in two spectral bands. A photomultiplier tube makes optical measurements in the ultraviolet portion of the spectrum, and a silicon photodiode covers the visible region. The detectors, located outside the combustion chamber, receive the light energy radiated from the combustion process through fiber optic probes designed to operate in a high pressure environment. The optical fibers are aimed diagonally through the center of the injector at the combustion chamber wall downstream of the injector. The probes observe events occurring within a narrow conical-shaped field of view so that the system can quickly detect longitudinal movement of the flame front away from the injector. If a change in intensity of the flame is detected, the fuel supply to the combustion chamber is shut off, limiting the amount of unburned fuel in the combustion chamber which could reignite.

Borg, Stephen E.↗

Optical Flameout Detector

A device has been developed which monitors the presence of a flame within a combustion chamber. The optical flameout detection system responds to gross changes in combustor light intensity which is monitored in two spectral bands. A photomultiplier tube makes optical measurements in the ultraviolet portion of the spectrum and a silicon photodiode covers the visible region. The detectors, located outside the combustion chamber, receive the light energy radiated from the combustion process through fiber optic probes designed to operate in a high pressure environment. The optical fibers are aimed diagonally through the center of the injector at the combustion chamber wall downstream of the injector. The probe observes events occurring within a narrow conical-shaped field of view so that the system can quickly detect longitudinal movement of the flame front away from the injector. If a change in intensity of the flame is detected, the fuel supply to the combustion chamber is shut off limiting the amount of unburned fuel in the combustion chamber which could reignite.

Borg, Stephen E.↗