Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Eco-Bio-Social Factors That Modulate Aedes aegypti Abundance in South Texas Border Communities

Aedes aegypti control requires dedicated resources that are usually scarce, limiting the reach and sustainability of vector control programs. This generates a need to focus on areas at risk of disease transmission and also understand the factors that might modulate local mosquito abundance. We evaluated the eco-bio-social factors that modulate indoor and outdoor relative abundance of female Ae. aegypti in communities of South Texas. We conducted housing quality and Knowledge Attitudes and Practices surveys in households that were part of a weekly mosquito surveillance program in November of 2017 and 2018. Our results showed widespread knowledge of mosquitoes and Zika virus by our participants. However, less than 35% considered them as serious problems in this region. The presence of window-mounted air conditioning units increased the risk of female mosquito relative abundance indoors. An increase in outdoor relative abundance was associated with larger properties and a higher number of children between 6 to 17 years of age. Interestingly, we observed that an increasing number of children <5 years of age modulated both indoor and outdoor relative abundance, with a 52% increase indoors and 30% decrease outdoors. The low perception of mosquito and disease risk highlights engagement needs for vector-borne disease prevention in this region. The identified risk factors can help guide public health officials in their efforts to reduce human and vector contact.

54 ENVIRONMENTAL SCIENCES↗

Initial comparisons of solar collector performance data obtained out-of doors and with a solar simulator

A facility was constructed to evaluate solar collector performance outdoors for conditions that would be encountered by collectors if they were incorporated in a solar heating/cooling system. In addition to obtaining initial collector performance data, the outdoor facility will enable collector durability and degradation rates to be evaluated for operating periods of several months. The data obtained from the outdoor tests were compared to collector performance predicted on the basis of results obtained with a solar simulator. The performance measured outdoors was less than the predicted performance.

Vernon, R. W.↗

Initial comparisons of solar collector performance data obtained out-of doors and with a solar simulator

A facility was constructed to evaluate solar collector performance outdoors for conditions that would be encountered by collectors if they were incorporated in a solar heating/cooling system. In addition to obtaining initial collector performance data, the outdoor facility will enable collector durability and degradation rates to be evaluated for operating periods of several months. The data obtained from the outdoor tests were compared to collector performance predicted on the basis of results obtained with a solar simulator. The performance measured outdoors was less than the predicted performance.

Vernon, R. W.↗

A pilot study of human response to general aviation aircraft noise

A pilot study, conducted to evaluate procedures for measuring the noise impact and community response to general aviation aircraft around Torrance Municipal Airport, a typical large GA airport, employed Torrance Airport's computer-based aircraft noise monitoring system, which includes nine permanent monitor stations surrounding the airport. Some 18 residences near these monitor stations were equipped with digital noise level recorders to measure indoor noise levels. Residents were instructed to fill out annoyance diaries for periods of 5-6 days, logging the time of each annoying aircraft overflight noise event and judging its degree of annoyance on a seven-point scale. Among the noise metrics studied, the differential between outdoor maximum A-weighted noise level of the aircraft and the outdoor background level showed the best correlation with annoyance; this correlation was clearly seen at only high noise levels, And was only slightly better than that using outdoor aircraft noise level alone. The results indicate that, on a national basis, a telephone survey coupled with outdoor noise measurements would provide an efficient and practical means of assessing the noise impact of general aviation aircraft.

Stearns, J.↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

Neural Network Research on Tilt-Rotor Hover Performance

Results from a neural network study on XV-15 tilt-rotor hover performance are presented. Two XV-15 test data bases, acquired during separate tests conducted in the National Full-Scale Aerodynamics Complex at NASA Ames, were used in this study. The two XV-15 test data bases used were: the 1997 80- by 120-Foot Wind Tunnel test data base and the 1984 Outdoor Aerodynamic Research Facility (OARF) test data base. The objectives associated with the 80- by 120-Foot Wind Tunnel test data were to conduct data quality checks, obtain neural network representations, and demonstrate sensitivity to test conditions. The objectives associated with the OARF outdoor test data were to obtain a 'zero wind' neural network representation, and formulate and implement a neural network based wind correction procedure. An additional objective, common to both test data bases, was to conduct error comparisons. The conclusions from the present study were as follows: Compared to measured parameters (i.e., collective pitch angle), derived parameters (i.e., thrust coefficient) were found preferable as neural network inputs. For the 80- by 120-Foot Wind Tunnel test data base, the neural network based figure of merit representations did not extrapolate rotor stall. Using the OARF outdoor test database, a neural network based wind correction procedure was formulated and successfully implemented. Based on an error comparison, the present neural network based wind correction procedure was found to be more accurate compared to the existing, momentum-theory-based wind correction procedure. Also, a separate error comparison showed that the 80- by 120-Foot Wind Tunnel hover performance data were comparable to non-wind-corrected outdoor test data.

Kozapalli, S.↗

An Integrated 0-1 Hour First-Flash Lightning Nowcasting, Lightning Amount and Lightning Jump Warning Capability

Lightning one of the most dangerous weather-related phenomena, especially as many jobs and activities occur outdoors, presenting risk from a lightning strike. Cloud-to-ground (CG) lightning represents a considerable safety threat to people at airfields, marinas, and outdoor facilities-from airfield personnel, to people attending outdoor stadium events, on beaches and golf courses, to mariners, as well as emergency personnel. Holle et al. (2005) show that 90% of lightning deaths occurred outdoors, while 10% occurred indoors despite the perception of safety when inside buildings. Curran et al. (2000) found that nearly half of fatalities due to weather were related to convective weather in the 1992-1994 timeframe, with lightning causing a large component of the fatalities, in addition to tornadoes and flash flooding. Related to the aviation industry, CG lightning represents a considerable hazard to baggage-handlers, aircraft refuelers, food caterers, and emergency personnel, who all become exposed to the risk of being struck within short time periods while convective storm clouds develop. Airport safety protocols require that ramp operations be modified or discontinued when lightning is in the vicinity (typically 16 km), which becomes very costly and disruptive to flight operations. Therefore, much focus has been paid to nowcasting the first-time initiation and extent of lightning, both of CG and of any lightning (e.g, in-cloud, cloud-to-cloud). For this project three lightning nowcasting methodologies will be combined: (1) a GOESbased 0-1 hour lightning initiation (LI) product (Harris et al. 2010; Iskenderian et al. 2012), (2) a High Resolution Rapid Refresh (HRRR) lightning probability and forecasted lightning flash density product, such that a quantitative amount of lightning (QL) can be assigned to a location of expected LI, and (3) an algorithm that relates Pseudo-GLM data (Stano et al. 2012, 2014) to the so-called "lightning jump" (LJ) methodology (Shultz et al. 2011) to monitor lightning trends and to anticipate/forecast severe weather (hail > or =2.5 cm, winds > or =25 m/s, tornadoes). The result will be a time-continuous algorithm that uses GOES satellite, radar fields, and HRRR model fields to nowcast first-flash LI and QL, and subsequently monitors lightning trends on a perstorm basis within the LJ algorithm for possible severe weather occurrence out to > or =3 hours. The LI-QL-LJ product will also help prepare the operational forecast community for Geostationary Lightning Mapper (GLM) data expected in late 2015, as these data are monitored for ongoing convective storms. The LI-QL-LJ product will first predict where new lightning is highly probable using GOES imagery of developing cumulus clouds, followed by n analysis of NWS (dual-polarization) radar indicators (reflectivity at the -10 C altitude) of lightning occurrence, to increase confidence that LI is immanent. Once lightning is observed, time-continuous lightning mapping array and Pseudo-GLM observations will be analyzed to assess trends and the severe weather threat as identified by trends in lightning (i.e. LJs). Additionally, 5- and 15-min GOES imagery will then be evaluated on a per-storm basis for overshooting and other cloud-top features known to be associated with severe storms. For the processing framework, the GOES-R 0-1 hour convective initiation algorithm's output will be developed within the Warning Decision Support System - Integrated Information (WDSS-II) tracking tool, and merged with radar and lightning (LMA/Psuedo-GLM) datasets for active storms. The initial focus of system development will be over North Alabama for select lightning-active days in summer 2014, yet will be formed in an expandable manner. The lightning alert tool will also be developed in concert with National Weather Service (NWS) forecasters to meet their needs for real-time, accurate first-flash LI and timing, as well as anticipated lightning trends, amounts, continuation and cessation, so to provide key situational awareness and decision support information. The NASA Short-term Prediction Research and Transition (SPoRT) Center will provide important logistical and collaborative support and training, involving interactions with the NWS and broader user community.

Mecikalski, John↗

GPS/Optical/Inertial Integration for 3D Navigation Using Multi-Copter Platforms

In concert with the continued advancement of a UAS traffic management system (UTM), the proposed uses of autonomous unmanned aerial systems (UAS) have become more prevalent in both the public and private sectors. To facilitate this anticipated growth, a reliable three-dimensional (3D) positioning, navigation, and mapping (PNM) capability will be required to enable operation of these platforms in challenging environments where global navigation satellite systems (GNSS) may not be available continuously. Especially, when the platform's mission requires maneuvering through different and difficult environments like outdoor opensky, outdoor under foliage, outdoor-urban and indoor, and may include transitions between these environments. There may not be a single method to solve the PNM problem for all environments. The research presented in this paper is a subset of a broader research effort, described in [1]. The research is focused on combining data from dissimilar sensor technologies to create an integrated navigation and mapping method that can enable reliable operation in both an outdoor and structured indoor environment. The integrated navigation and mapping design is utilizes a Global Positioning System (GPS) receiver, an Inertial Measurement Unit (IMU), a monocular digital camera, and three short to medium range laser scanners. This paper describes specifically the techniques necessary to effectively integrate the monocular camera data within the established mechanization. To evaluate the developed algorithms a hexacopter was built, equipped with the discussed sensors, and both hand-carried and flown through representative environments. This paper highlights the effect that the monocular camera has on the aforementioned sensor integration scheme's reliability, accuracy and availability.

Dill, Evan T.↗

Data center coolant switch

A data center cooling system is operated in a first mode; it has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during the first mode. The first heat transfer fluid is a relatively high performance heat transfer fluid (as compared to the second fluid), and has a first heat transfer fluid freezing point. A determination is made that an appropriate time has been reached to switch from the first mode to a second mode. Based on this determination, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid, as compared to the first heat transfer fluid. It has a second heat transfer fluid freezing point lower than the first heat transfer fluid freezing point, and the second heat transfer fluid freezing point is sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Design Guidance for Passive Vents in New Construction Multifamily Buildings, New York, New York

This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated source of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling process and system for dry cooling power plants

A seasonal process that captures stores and uses water in an ambient temperature-dependent manner to improve the efficiency of a natural gas power plant, comprising: (a) providing a natural gas power plant, the natural gas power plant having a flue gas stream, a cooling tower, and a gas turbine; (b) providing a water collection system; (c) providing a water storage facility; wherein the flue gas stream comprises uncondensed water vapor; wherein the water collection system is operably connected to the flue gas stream and the flue gas stream is directed to flow, at least in part, into the water collection system; wherein the water collection system is operably connected to the water storage facility; wherein the water storage facility is operably connected to the cooling tower and the water storage facility is operably connected to the gas turbine; wherein the process comprises the following steps of condensing flue gas water or using water that has been condensed from the flue gas stream based on outdoor ambient dry bulb temperature: (I) Only condensing water from the flue gas stream to produce a condensed water stream if outdoor ambient dry bulb temperature is less than 85° F.; (II) Only using condensed water to spray cool the cooling tower if outdoor ambient dry bulb temperature is at least 85° F.; (III) Only using condensed water to fog cool the gas turbine if outdoor ambient dry bulb temperature is at least 55° F.; wherein condensed water that is not immediately used to cool the cooling tower or to fog cool the gas turbine is stored in the water storage facility; and wherein the process uses a total amount of water on an annual basis to cool the cooling tower and to fog cool the gas turbine that does not exceed the annual amount of water condensed from the flue gas stream. Optionally, the process has a cooling tower that is a dry cooling tower and condensed water is used to spray cool the dry cooling tower, or the cooling tower is a wet cooling tower, or the cooling tower is a hybrid wet-dry cooling tower. The process may further comprise a water collection system having a three stage desiccant cycle and a calcium chloride desiccant that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condensing column that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condenser and a rotating wheel heat exchanger that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure, or further comprises plastic piping or plastic vessels. The coefficient of performance for the cooling process is optionally at least 2.0.

Srinivas, Girish↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

42 ENGINEERING↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

42 ENGINEERING↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗

New Method to Characterize Degradation of First Surface Aluminum Reflectors: Preprint

This paper reports the development of a new optical instrument capable of characterizing the aging process of enhanced first surface aluminum reflectors for concentrating solar power (CSP) application. Samples were exposed outdoors at different sites and in accelerated exposure tests. All samples exposed outdoors showed localized corrosion spots. Degradation originated from points of damage inthe protective coating, but propagated underneath the protective coating. The degraded samples were analyzed with a microscope and with a newly designed space-resolved specular reflectometer (SR)2 that is capable of optically detecting and characterizing the corrosion spots. The device measures the specular reflectance at three acceptance angles and the wavelengths with spatial resolution usinga digital camera's CMOS sensor. It can be used to measure the corrosion growth rate during outdoor and accelerated exposure tests. These results will allow a correlation between the degraded mirror surface and its specular reflectance.

14 SOLAR ENERGY↗

Lateral Spectrum Splitting Concentrator Photovoltaics: Direct Measurement of Component and Submodule Efficiency

To achieve high energy conversion efficiency, a solar module architecture called lateral spectrum splitting concentrator photovoltaics (LSSCPV) is being developed. LSSCPV can concentrate available sunlight and laterally split a single beam into bands with different spectra for absorption by different solar cells with band gaps matched to the split spectrum. Test assemblies of a sample LSSCPV architecture were constructed, each of which contains four p-n junctions and two optical pieces. Independent experiments or simulations had been implemented on the components but by using optimal assumptions. In order to examine the actual performances of all the components, which are dependent on each other and the light source, direct outdoor measurements were made. A set of self-consistent efficiency definitions was articulated and a test bed was developed to measure the parameters required by the efficiency calculation. By comparing the component efficiency items derived from the outdoor measurement and the expected values based on independent simulations, the potential opportunities for efficiency improvement are determined. In the outdoor measurement at the University of Delaware, the optical component demonstrated 89.1% efficiency. Additional assemblies were tested at the National Renewable Energy Laboratory. One assembly demonstrated 36.7% submodule efficiency, which compares favorably with the 32.6% previously reported verified submodule efficiency.

14 SOLAR ENERGY↗

Demonstration of photoreactor platform for on-sun unassisted photoelectrochemical hydrogen generation with tandem III–V photoelectrodes

Photoelectrochemical (PEC) water splitting is a direct solar-driven technology that converts solar energy to storable chemical energy in the form of hydrogen. In addition to semiconductor and catalyst development for improved photoelectrodes, designing reactors for testing and operation of PEC systems under inherently dynamic outdoor solar illumination is necessary to further the commercial viability of PEC technology. Herein, we present a versatile photoreactor system mounted on a solar tracker for outdoor PEC testing and demonstrate unassisted PEC water splitting under real world on-sun conditions. GaInP 2 /GaAs tandem absorber photoelectrodes with a MoS 2 catalyst were fabricated and exhibit >8% solar-to-hydrogen efficiency. On-sun efficiency and stability of the photoelectrodes were characterized on both sunny and partly cloudy days with continuous monitoring of insolation and weather conditions. Furthermore, the versatile photoreactor and outdoor PEC testing capabilities and methods presented here can accelerate the development of other solar fuel generating systems and technologies.

solar fuels↗