Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Note: Diagnosing femtosecond laser-solid interactions with monochromatic K{sub {alpha}} imager and x-ray pinhole camera

An x-ray pinhole camera and a monochromatic K{sub {alpha}} imager are used to measure the interactions of intense femtosecond laser pulses with Cu foil targets. The two diagnostics give different features in the spot size and the laser energy scaling, which are resulted from different physical processes. Under our experimental conditons, the K{sub {alpha}} emission is mainly excited by the fast electrons transporting inside the cold bulk target. In contrast, the x-ray pinhole signals are dominated by the broadband thermal x-ray emission from the hot plasma at the front target surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Ultrasonic gas flowmeter based on optimized time-of-flight algorithms

A new digital signal processor based single path ultrasonic gas flowmeter is designed, constructed, and experimentally tested. To achieve high accuracy measurements, an optimized ultrasound driven method of incorporation of the amplitude modulation and the phase modulation of the transmit-receive technique is used to stimulate the transmitter. Based on the regularities among the received envelope zero-crossings, different received signal's signal-to-noise ratio situations are discriminated and optional time-of-flight algorithms are applied to take flow rate calculations. Experimental results from the dry calibration indicate that the designed flowmeter prototype can meet the zero-flow verification test requirements of the American Gas Association Report No. 9. Furthermore, the results derived from the flow calibration prove that the proposed flowmeter prototype can measure flow rate accurately in the practical experiments, and the nominal accuracies after FWME adjustment are lower than 0.8% throughout the calibration range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Flowing ion population from a resonance cavity source

The experimental low energy plasma for hemispherical analyzers nominal testing thermal plasma facility of Dartmouth College uses a microwave plasma source which generates an ionosphere-like plasma through a two-step process. The plasma is initially generated inside a cylindrical, insulated, resonance cavity. This initial plasma must pass through a sheath in order to enter the main experimental region. This process imparts a significant flow velocity to the ions which has been neglected in previous analysis of this plasma source. We predict the flow energy of the ions to be between 12-15 eV depending on conservation laws and show agreement with experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Non-gain microchannel plate gated framing camera

An x-ray framing camera using a non-gain microchannel plate (MCP) is reported in this article. The advantage of the non-gain MCP is the less transit time spread. The non-gain MCP gated framing camera has four microstrip line cathodes with 6 mm in width. The time domain reflectometry curves of the four microstrip lines are measured, which show that the characteristic impedance of each microstrip line is about 17 {Omega}. While the photocathode is driven by the gating electrical pulse with width of 125 ps and amplitude of -1.48 kV with -400 V bias, the measured exposure time of this camera is about 72 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some notes on the application of discrete wavelet transform in image processing

Mathematical transforms are used in signal processing in order to extract what is known as 'hidden' information. One of these mathematical tools is the Discrete Wavelet Transform (DWT), which has been increasingly employed in non-destructive testing and, more specifically, in image processing. The main concern in the present work is to employ DWT to suppress noise without losing relevant image features. However, some aspects must be taken into consideration when applying DWT in image processing, mainly in the case of weld radiographs, in order to achieve consistent results. Three topics were selected as representative of these difficulties, as follows: 1) How can image matrix be filled to fit the 2{sup n} lines and 2{sup n} rows requirement? 2) How can the most suitable decomposition level of the DWT function and the correct choice of their coefficient suppression be selected? 3) Is there any influence of the scanning direction and the weld radiograph image, e.g., longitudinal or transversal, on the final processing image? It is known that some artifacts may be present in weld radiograph images. Indeed, the weld surface is frequently rough and rippled, what can be seen as gray level variation on the radiograph, being sometimes mistaken as defective areas. Depending on the position of these artifacts, longitudinal or transversal to the weld bead, they may have different influences on the image processing procedure. This influence is clearly seen in the distribution of the DWT Function coefficients. In the present work, examples of two weld radiographs of quite different image quality were given in order to exemplify it.

07 ISOTOPE AND RADIATION SOURCES↗

Note: Laser ablation technique for electrically contacting a buried implant layer in single crystal diamond

The creation of thin, buried, and electrically conducting layers within an otherwise insulating diamond by annealed ion implantation damage is well known. Establishing facile electrical contact to the shallow buried layer has been an unmet challenge. We demonstrate a new method, based on laser micro-machining (laser ablation), to make reliable electrical contact to a buried implant layer in diamond. Comparison is made to focused ion beam milling.

36 MATERIALS SCIENCE↗

Note: Direct measurement of the point-to-point resolution for microns-thick specimens in the ultrahigh-voltage electron microscope

We report on a direct measurement method and results of the point-to-point resolution for microns-thick amorphous specimens in the ultrahigh-voltage electron microscope (ultra-HVEM). We first obtain the ultra-HVEM images of nanometer gold particles with different sizes on the top surfaces of the thick epoxy-resin specimens. Based on the Rayleigh criterion, the point-to-point resolution is then determined as the minimum distance between centers of two resolvable tangent gold particles. Some values of resolution are accordingly acquired for the specimens with different thicknesses at the accelerating voltage of 2 MV, for example, 18.5 nm and 28.4 nm for the 5 {mu}m and 8 {mu}m thick epoxy-resin specimens, respectively. The presented method and results provide a reliable and useful approach to quantifying and comparing the achievable spatial resolution for the thick specimens imaged in the mode of transmission electron including the scanning transmission electron microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Study of extreme ultraviolet and soft x-ray emission of metal targets produced by laser-plasma-interaction

Different metal targets were investigated as possible source material for tailored laser-produced plasma-sources. In the wavelength range from 1 to 20 nm, x-ray spectra were collected with a calibrated spectrometer with a resolution of {lambda}/{Delta}{lambda}= 150 at 1 nm up to {lambda}/{Delta}{lambda}= 1100 at 15 nm. Intense line emission features of highly ionized species as well as continuum-like spectra from unresolved transitions are presented. With this knowledge, the optimal target material can be identified for the envisioned application of the source in x-ray spectrometry on the high energy side of the spectra at about 1 keV. This energy is aimed for because 1 keV-radiation is ideally suited for L-shell x-ray spectroscopy with nm-depth resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Vector reflectometry in a beam waveguide

We present a one-port calibration technique for characterization of beam waveguide components with a vector network analyzer. This technique involves using a set of known delays to separate the responses of the instrument and the device under test. We demonstrate this technique by measuring the reflected performance of a millimeter-wave variable-delay polarization modulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Seesaw actuation of atomic force microscope probes for improved imaging bandwidth and displacement range

The authors describe a method of actuation for atomic force microscope (AFM) probes to improve imaging speed and displacement range simultaneously. Unlike conventional piezoelectric tube actuation, the proposed method involves a lever and fulcrum ''seesaw'' like actuation mechanism that uses a small, fast piezoelectric transducer. The lever arm of the seesaw mechanism increases the apparent displacement range by an adjustable gain factor, overcoming the standard tradeoff between imaging speed and displacement range. Experimental characterization of a cantilever holder implementing the method is provided together with comparative line scans obtained with contact mode imaging. An imaging bandwidth of 30 kHz in air with the current setup was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Multi-point measurement of |B| in the gas-dynamic trap with a spectral motional Stark effect diagnostic

An upgraded spectral motional Stark effect diagnostic has been installed on the gas-dynamic trap (GDT) experiment to enable spatially resolved measurement of |B|. A new low-noise charge-coupled device detector, combined with enhancements of the diagnostic neutral beam, allows single-shot profile measurements. Previously only single-point motional Stark effect measurements were possible, and detector noise severely limited measurement precision, requiring multi-shot averaging. The plasma pressure profile in GDT is derived from the measured diamagnetic modification of |B| and used to examine the conditions of stable plasma confinement at high plasma pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗