Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

Axion pulsarscope

Electromagnetic fields surrounding pulsars may source coherent ultralight axion signals at the known rotational frequencies of the neutron stars, which can be detected by laboratory experiments (e.g., pulsarscopes). As a promising case study, we model axion emission from the well-studied Crab pulsar, which would yield a prominent signal at 𝑓 ≈ 29.6 Hz regardless of whether the axion contributes to the dark matter abundance. We estimate the relevant sensitivity of future axion dark matter detection experiments such as DMRadio-GUT, Dark SRF, and CASPEr, assuming different magnetosphere models to bracket the uncertainty in astrophysical modeling. For example, depending on final experimental parameters, the Dark SRF experiment could probe axions with any mass 𝑚 𝑎 ≪ 10 −13 eV down to 𝑔 𝑎⁢𝛾⁢𝛾 ∼3 × 10 −13 GeV −1 with one year of data and assuming the vacuum magnetosphere model. These projected sensitivities may be degraded depending on the extent to which the magnetosphere is screened by charge-filled plasma. The promise of pulsar-sourced axions as a clean target for direct detection experiments motivates dedicated simulations of axion production in pulsar magnetospheres.

axions↗

Observation of Ion Electrosorption in Metal–Organic Framework Micropores with In Operando Small-Angle Neutron Scattering

A molecular-level understanding of transport and adsorption mechanisms of electrolyte ions in nanoporous electrodes under applied potentials is essential to control the performance of double-layer capacitors. In this paper, in operando small-angle neutron scattering (SANS) is used to directly detect ion movements into the nanopores of a conductive metal–organic framework (MOF) electrode under operating conditions. Neutron-scattering data reveals that most of the void space within the MOF is accessible to the solvent. Upon the addition of the electrolyte sodium triflate (NaOTf), the ions are adsorbed on the outer surface of the protrusions to form a 30 Å layer instead of entering the ionophobic pores in the absence of an applied charging potential. The changes in scattering intensity when potentials are applied suggests the ion rearrangement in the micropores following different mechanisms depending on the electrode polarization. These observations shed insights on ion electrosorption in electrode materials.

36 MATERIALS SCIENCE↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Modeling light signals using data from the first pulsed neutron source program at the DUNE vertical drift ColdBox test facility at the CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN Neutrino Platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. We demonstrate the ability to identify the contribution from neutron interactions using X-ARAPUCA photodetectors, and show first comparisons of data to simulation, which indicate reasonable agreement. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and simulation. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

Detector modelling and simulations I (interaction ↗

Measuring the molecular Migdal effect with neutron scattering on diatomic gases

The Migdal effect is a key inelastic signal channel which could be used to detect low-mass dark matter, but it has never been observed experimentally using Standard Model probes. Here we propose a conceptual design for an experiment which could detect the Migdal effect in diatomic molecules through low-energy neutron scattering, and we provide the requirements on the beam spectrum and reducible backgrounds such that a detection may be achieved. The enhancement of the Migdal rate through non-adiabatic couplings, which are absent in isolated atoms, combined with the distinctive photon energies of electronic transitions in CO, suggest that a positive detection of the molecular Migdal effect may be possible with modest beam times at existing neutron facilities. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Constraining ΛCDM cosmological parameters with Einstein Telescope mock data

ABSTRACT We investigate the capability of Einstein Telescope to constrain the cosmological parameters of the non-flat ΛCDM cosmological model. Two types of mock data sets are considered depending on whether or not a short gamma-ray burst is detected, and associated with the gravitational wave emitted by binary neutron stars merger, using the THESEUS satellite. Depending on the mock data set, two statistical estimators are applied: one assumes that the redshift is known, while the other marginalizes over it assuming a specific redshift prior distribution. We demonstrate that (i) using mock catalogues collecting gravitational wave signals emitted by binary neutron stars systems to which a short gamma-ray burst has been associated, Einstein Telescope may achieve an accuracy on the cosmological parameters of $\sigma _{H_0}\approx 0.40$ km s−1 Mpc−1, $\sigma _{\Omega _{k,0}}\approx 0.09$, and $\sigma _{\Omega _{\Lambda ,0}}\approx 0.07$; while (ii) using mock catalogues collecting all gravitational wave signals emitted by binary neutron stars systems for which an electromagnetic counterpart has not been detected, Einstein Telescope may achieve an accuracy on the cosmological parameters of $\sigma _{H_0}\approx 0.04$ km s−1 Mpc−1, $\sigma _{\Omega _{k,0}}\approx 0.01$, and $\sigma _{\Omega _{\Lambda ,0}}\approx 0.01$, once the redshift probability distribution of GW events is known from from population synthesis simulations and/or the measure of the tidal deformability parameter. These results show an improvement of a factor 2–75 with respect to earlier results using complementary data sets.

Califano, Matteo↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-induced fission fragment angular distributions, anisotropy, and linear momentum transfer measured with the NIFFTE fission time projection chamber

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning 235 U, 238 U, and 239Pu and fission fragment angular anisotropy of 235 U and 238 U as a function of neutron energies in the range 130 keV–250 MeV are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure and properties of NdCuGa 3 single crystals

Here this manuscript reports on the structural and magnetic properties of NdCuGa 3 using powder and single crystal X-ray diffraction (XRD), zero-field single crystal neutron diffraction, magnetization, and specific heat measurements. Our XRD on a single crystal specimen of NdCuGa3 confirmed that it crystallizes in the tetragonal BaNiSi 3 -type structure. A magnetic phase transition at T N = 3.3 K is assessed using specific heat and ac magnetic susceptibility measurements. No additional anomaly below T N down to 50 mK was detected by performing specific heat measurements. Neutron single crystal diffraction data collected at T = 300 mK confirm the antiferromagnetic phase below T N = 3.3 K with the propagation vector $\vec{\tau}$ = (0.2, 0, 0). Possible magnetic structure solutions of NdCuGa 3 are discussed

36 MATERIALS SCIENCE↗

Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping: FY2020 Annual Report to NA241 (Annual Report)

Lawrence Livermore National Laboratory has embarked upon development of a novel methodology for verification of spent fuel inside dry storage casks. The issue of verification of the integrity of spent fuel inside dry storage has been one of the most challenging technical problems facing IAEA for many decades. The difficulty arises because of the massive amount of shielding between the inner spent fuel and the outer surface where measurements can be performed. Despite many efforts, detection of useful gamma rays or neutrons from the outer surface has so far proven unsuccessful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

Revealing the short-range structure of the mirror nuclei 3 H and 3 He

When protons and neutrons (nucleons) are bound into atomic nuclei, they are close enough to feel significant attraction, or repulsion, from the strong, short-distance part of the nucleon-nucleon interaction. These strong interactions lead to hard collisions between nucleons, generating pairs of highly energetic nucleons referred to as short-range correlations (SRCs). SRCs are an important but relatively poorly understood part of nuclear structure, and mapping out the strength and the isospin structure (neutron-proton (np) versus proton-proton (pp) pairs) of these virtual excitations is thus critical input for modelling a range of nuclear, particle and astrophysics measurements. Two-nucleon knockout or 'triple coincidence' reactions have been used to measure the relative contribution of np-SRCs and pp-SRCs by knocking out a proton from the SRC and detecting its partner nucleon (proton or neutron). These measurements have shown that SRCs are almost exclusively np pairs, but they had limited statistics and required large model-dependent final-state interaction corrections. Here we report on measurements using inclusive scattering from the mirror nuclei hydrogen-3 and helium-3 to extract the np/pp ratio of SRCs in systems with a mass number of three. In this work we obtain a measure of the np/pp SRC ratio that is an order of magnitude more precise than previous experiments, and find a marked deviation from the near-total np dominance observed in heavy nuclei. This result implies an unexpected structure in the high-momentum wavefunction for hydrogen-3 and helium-3. Understanding these results will improve our understanding of the short-range part of the nucleon-nucleon interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗