Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A beam hardening and dispersion correction for x-ray dark-field radiography

Purpose: X-ray dark-field imaging promises information on the small angle scattering properties even of large samples. However, the dark-field image is correlated with the object’s attenuation and phase-shift if a polychromatic x-ray spectrum is used. A method to remove part of these correlations is proposed. Methods: The experimental setup for image acquisition was modeled in a wave-field simulation to quantify the dark-field signals originating solely from a material’s attenuation and phase-shift. A calibration matrix was simulated for ICRU46 breast tissue. Using the simulated data, a dark-field image of a human mastectomy sample was corrected for the finger print of attenuation- and phase-image. Results: Comparing the simulated, attenuation-based dark-field values to a phantom measurement, a good agreement was found. Applying the proposed method to mammographic dark-field data, a reduction of the dark-field background and anatomical noise was achieved. The contrast between microcalcifications and their surrounding background was increased. Conclusions: The authors show that the influence of and dispersion can be quantified by simulation and, thus, measured image data can be corrected. The simulation allows to determine the corresponding dark-field artifacts for a wide range of setup parameters, like tube-voltage and filtration. The application of the proposed method to mammographic dark-field data shows an increase in contrast compared to the original image, which might simplify a further image-based diagnosis.

60 APPLIED LIFE SCIENCES↗

Sci—Thur PM: Imaging — 01: Position-sensitive noise characteristics in multi-pinhole cardiac SPECT imaging

Myocardial perfusion imaging (MPI) with Single Photon Emission Computed Tomography (SPECT) is invaluable in the diagnosis and management of heart disease. It provides essential information on myocardial blood flow and ischemia. Multi-pinhole dedicated cardiac-SPECT cameras offer improved count sensitivity, and spatial and energy resolutions over parallel-hole camera designs however variable sensitivity across the field-of-view (FOV) can lead to position-dependent noise variations. Since MPI evaluates differences in the signal-to-noise ratio, noise variations in the camera could significantly impact the sensitivity of the test for ischemia. We evaluated the noise characteristics of GE Healthcare's Discovery NM530c camera with a goal of optimizing the accuracy of our patient assessment and thereby improving outcomes. Theoretical sensitivity maps of the camera FOV, including attenuation effects, were estimated analytically based on the distance and angle between the spatial position of a given voxel and each pinhole. The standard deviation in counts, σ was inferred for each voxel position from the square root of the sensitivity mapped at that position. Noise was measured experimentally from repeated (N=16) acquisitions of a uniform spherical Tc-99m-water phantom. The mean (μ) and standard deviation (σ) were calculated for each voxel position in the reconstructed FOV. Noise increased ∼2.1× across a 12 cm sphere. A correlation of 0.53 is seen when experimental noise is compared with theory suggesting that ∼53% of the noise is attributed to the combined effects of attenuation and the multi-pinhole geometry. Further investigations are warranted to determine the clinical impact of the position-dependent noise variation.

60 APPLIED LIFE SCIENCES↗

Low-frequency attenuator circuit

Circuit uses only single operational amplifier and few passive components to remove background noise from miniature "wristwatch" pulse detector. It can be applied to other systems where background noise is slowly varying, such as ultrasonics, strain-gage sensors, and accelerometers.

Cash, W. H., Jr.↗

A Review of Noise and Vibration Control Technologies for Rotorcraft Transmissions

An expanded commercial use of rotorcraft can alleviate runway congestion and improve the accessibility of routine air travel. To date, commercial use has been hindered by excessive cabin noise. The primary noise source is structure-borne vibration originating from the main rotor gearbox. Despite significant advancements in gear design, the gear mesh tones generated often exceed 100 dB. This paper summarizes the findings of a literature survey of vibration control technologies that serve to attenuate this vibration near the source, before it spreads into the airframe and produces noise. The scope is thus limited to vibration control treatments and modifications of the gears, driveline, housing structures, and the strut connections to the airframe. The findings of the literature are summarized and persistent and unresolved issues are identified. An emphasis is placed on components and systems that have been demonstrated in flight vehicles. Then, a discussion is presented of emerging technologies that have the potential to make significant advancements over the state of the art.

cabin noise↗

A Review of Noise and Vibration Control Technologies for Rotorcraft Transmissions

An expanded commercial use of rotorcraft can alleviate runway congestion and improve the accessibility of routine air travel. To date, commercial use has been hindered by excessive cabin noise. The primary noise source is structure-borne vibration originating from the main rotor gearbox. Despite significant advancements in gear design, the gear mesh tones generated often exceed 100 dB. This paper summarizes the findings of a literature survey of vibration control technologies that serve to attenuate this vibration near the source, before it spreads into the airframe and produces noise. The scope is thus limited to vibration control treatments and modifications of the gears, driveline, housing structures, and the strut connections to the airframe. The findings of the literature are summarized and persistent and unresolved issues are identified. An emphasis is placed on components and systems that have been demonstrated in flight vehicles. Then, a discussion is presented of emerging technologies that have the potential to make significant advancements over the state of the art.

cabin noise↗

Strong increase in ultrasound attenuation below T c in Sr 2 RuO 4 : Possible evidence for domains

Recent experiments suggest that Sr 2 RuO 4 has a two-component superconducting order parameter (OP). A two-component OP has multiple degrees of freedom in the superconducting state that can result in low-energy collective modes or the formation of domain walls—a possibility that would explain a number of experimental observations including the smallness of the signature of time reversal symmetry breaking at T c and telegraph noise in critical current experiments. We use resonant ultrasound spectroscopy to perform ultrasound attenuation measurements across the superconducting T c of Sr 2 RuO 4 . We find that compressional sound attenuation increases by a factor of 7 immediately below T c , in sharp contrast with what is found in both conventional (s-wave) and high-T c (d-wave) superconductors. Our observations are most consistent with the presence of domain walls that separate different configurations of the superconducting OP. Here, the fact that we only observe an increase in sound attenuation for compressional strains, and not for shear strains, suggests an inhomogeneous superconducting state formed of two distinct, accidentally degenerate superconducting OPs that are not related to each other by symmetry. Whatever the mechanism, a factor of 7 increase in sound attenuation is a singular characteristic that must be reconciled with any potential theory of superconductivity in Sr 2 RuO 4 .

36 MATERIALS SCIENCE↗

Modeling self-subtraction in angular differential imaging: Application to the HD 32297 debris disk

We present a new technique for forward-modeling self-subtraction of spatially extended emission in observations processed with angular differential imaging (ADI) algorithms. High-contrast direct imaging of circumstellar disks is limited by quasi-static speckle noise, and ADI is commonly used to suppress those speckles. However, the application of ADI can result in self-subtraction of the disk signal due to the disk's finite spatial extent. This signal attenuation varies with radial separation and biases measurements of the disk's surface brightness, thereby compromising inferences regarding the physical processes responsible for the dust distribution. To compensate for this attenuation, we forward model the disk structure and compute the form of the self-subtraction function at each separation. As a proof of concept, we apply our method to 1.6 and 2.2 μm Keck adaptive optics NIRC2 scattered-light observations of the HD 32297 debris disk reduced using a variant of the 'locally optimized combination of images' algorithm. We are able to recover disk surface brightness that was otherwise lost to self-subtraction and produce simplified models of the brightness distribution as it appears with and without self-subtraction. From the latter models, we extract radial profiles for the disk's brightness, width, midplane position, and color that are unbiased by self-subtraction. Our analysis of these measurements indicates a break in the brightness profile power law at r ≈ 110 AU and a disk width that increases with separation from the star. We also verify disk curvature that displaces the midplane by up to 30 AU toward the northwest relative to a straight fiducial midplane.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying Acoustic Emission to Large Format Additive Manufacturing

Large format additive manufacturing (AM) is being adapted as a method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing development and feedstock material but minimum research on the structural health monitoring (SHM), defect detection, and nondestructive evaluation (NDE) for large format AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. Acoustic emission (AE) is a passive technique that can be used to monitor and locate defect progression in large structures by distributing group of sensors around the part. This research outlines the necessary procedure for implementing AE to AM as a reliability method. The topics this research will display are: (a) Wave propagation/velocity evaluation, (b) an AE attenuation characterization for the anisotropic printed structure and material, (c) background noise measurements of the extruder and gantry system, and (d) assist in optimal sensor selection and placement for monitoring large AM structures with demonstration. This work establishes the foundation for scaling up the SHM-AE system for the large additive platform.

Spencer, Ryan↗

Optimum FM pre-emphasis

Calibrated RF signal generator, precision RF attenuator, and a wave analyzer are used to determine the spectral noise characteristics in the baseband of receiver as a function of RF input power.

Merz, K. W.↗

Laser Doppler systems in atmospheric turbulence

The loss of heterodyne signal power for the Marshall Space Flight Center laser Doppler system due to the random changes in the atmospheric index of refraction is investigated. The current status in the physics of low energy laser propagation through turbulent atmosphere is presented. The analysis and approximate evaluation of the loss of the heterodyne signal power due to the atmospheric absorption, scattering, and turbulence are estimated for the conditions of the January 1973 flight tests. Theoretical and experimental signal to noise values are compared. Maximum and minimum values of the atmospheric attenuation over a two way path of 20 km range are calculated as a function of altitude using models of atmosphere, aerosol concentration, and turbulence.

Murty, S. S. R.↗

A microcomputer-based system for noise characteristics analysis

A description is given of the design and use of a microcomputer-based system for the analysis and prediction of interior noise levels in general aviation aircraft constructed from novel materials. The system consists of a test chamber divided into two parts by a panel which has been fabricated from the material or combination of materials to be tested. A noise generator applies noise to one side of the specimen, while the microcomputer system measures and records the noise spectra on both sides of the specimen, so that its attenuation properties may be calculated and displayed by both a color CRT and X-Y plotter hard copy.

Mosser, M. A.↗

A High-Order L-Band HTS Filter for Sensitive Detecting

In this paper, a new high-temperature superconducting (HTS)-based microwave radiometer with an improved sensitivity is presented. The cryogenic receiver front end consists of an HTS filter and a cryogenic low noise amplifier (LNA). The cryogenic receiver front end shows an ultra-low noise figure and can suppress radio frequency interference (RFI) effectively. The proposed HTS filter works at a center frequency of 1.4135 GHz with a bandwidth of 25 MHz. The measured mid-band insertion loss, side band steepness, and out-of-band attenuation of the HTS filter are 0.14 dB, 35 dB/MHz, and 80 dB, respectively. The noise figure of the cryogenic LNA is about 0.27 dB at a temperature of 77 K. Compared with other total power radiometers, the proposed radiometer has a lower receiver noise temperature, which can improve the sensitivity with a short integration time of the satellite-based salinity meter. In addition, since the bandwidth of the salinity meter is fixed and the integration time of satellite-based equipment is limited, such a low receiver noise temperature can increase the flexibility of future satellite payload configuration program.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compensating rain induced impairments in terrestrial FSO links using aperture averaging and receiver diversity

In this paper, we investigate the performance of a free space optical link considering the deteriorations caused by heavy rain. The applicability of receiver diversity and aperture averaging techniques to compensate the rain-induced impairments is analyzed on the basis of outage probability and signal to noise ratio at varying rain intensities. A 10-Mbps on-off keying modulated optical signal is taken as the test signal for which rain specific attenuation is calculated using a laboratory testbed having controlled rainfall conditions up to 250 mm/h. A 15-m single input multi output) optical link with selection combining technique at the receiver is used to observe diversity gain. Significant diversity improvement by a factor of 1.35 is observed by comparing the results with the conventional single input single output link. Experimental observations with and without aperture averaging shows average SNR gain of 1.58 and outage probability reduction of 12.3%.

42 ENGINEERING↗

The effect of modeling dose uncertainty on low-boom community noise dose-response curves

In logistic dose-response modeling, failing to account for uncertainty in estimated doses can cause an artificial flattening or attenuation of the slope of the summary curve. In Lee et al. [J. Acoust. Soc. Am. 147(4), pp. 2222-2234 (2020)], data from two NASA low-amplitude sonic boom community noise survey tests were modeled using a Bayesian multilevel logistic regression (MLR) statistical model that assumed there was no uncertainty in the noise dose estimates. However, in these community tests, the noise dose uncertainty was estimated by Page et al. [NASA/CR-2014-218180 and NASA/CR-2020-220589/Volume I] using a leave-one-out method. In the current work, a term was added to extend the Bayesian MLR model to account for the estimated noise dose uncertainty quantified in the Page et al. analyses. This uncertainty term was included in two ways, either as classical or as Berkson uncertainty, and yield similar results. When the uncertainty is accounted for in the Bayesian MLR model, the dose-response curves become 5-10% steeper, but the difference in the noise dose that elicits a 5% highly annoyed response is small (less than 1 dB). This result is encouraging for future X-59 community tests whose survey area will be sparsely populated with noise monitors.

X-59↗

Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic guide for noise-transmission testing of aircraft

Selective testing of aircraft or other vehicular components without requiring disassembly of the vehicle or components was accomplished by using a portable guide apparatus. The device consists of a broadband noise source, a guide to direct the acoustic energy, soft sealing insulation to seal the guide to the noise source and to the vehicle component, and noise measurement microphones, both outside the vehicle at the acoustic guide output and inside the vehicle to receive attenuated sound. By directing acoustic energy only to selected components of a vehicle via the acoustic guide, it is possible to test a specific component, such as a door or window, without picking up extraneous noise which may be transmitted to the vehicle interior through other components or structure. This effect is achieved because no acoustic energy strikes the vehicle exterior except at the selected component. Also, since the test component remains attached to the vehicle, component dynamics with vehicle frame are not altered.

Vaicaitis, Rimas↗

Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

Introduction: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Methods: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in {sup 99m}Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R{sup 2}) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. Results: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R{sup 2}) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC −1.9-7.1; NR −0.4-4.4; NR + SC −1.1-4.3; NR + SC + RR −0.7-2.5) (CAD NC −1.2-3.8; NR −1.0-2.8; NR + SC −1.0-2.5; NR + SC + RR −1.1-2.6). Conclusions: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗