Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Memory device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A new method for using Cf-252 in SEU testing

A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.

Costantine, A.↗

A Third Arm for the Surgeon

In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

Source record↗

Computer driven optical keratometer and method of evaluating the shape of the cornea

An apparatus and method for measuring the shape of the cornea utilize only one reticle to generate a pattern of rings projected onto the surface of a subject's eye. The reflected pattern is focused onto an imaging device such as a video camera and a computer compares the reflected pattern with a reference pattern stored in the computer's memory. The differences between the reflected and stored patterns are used to calculate the deformation of the cornea which may be useful for pre-and post-operative evaluation of the eye by surgeons.

Baroth, Edmund C.↗

Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets in a NAND Flash Memory

We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found that the single-event upset (SEU) cross section varied inversely with cumulative fluence. We attribute the effect to the variable upset sensitivities of the memory cells. Furthermore, the effect impacts only single cell upsets in general. The rate of multiple-bit upsets remained relatively constant with fluence. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, traditional SEE testing techniques may underestimate the on-orbit event rate for a device with variable upset sensitivity.

NAND flash memory↗

Endurance cycling results in extreme environments

A new test bed for life testing flash memories in extreme environments is introducted. the test bed is based on a state-of-the-art development board. Since space applications often desire state-of-the-art devices, such a basis seems appropriate. Comparison of this tester to other such systems, including those with data presented here in the past is made. Limitations of different testers for varying applications are discussed. Recently developed data, using this test bed is also presented.

microelectronics↗

Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets of NAND Flash Memory

We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found the single-event upset (SEU) cross section varied inversely with fluence. The SEU cross section decreased with increasing fluence. We attribute the effect to the variable upset sensitivities of the memory cells. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, heavy ion irradiation of devices with variable upset sensitivity distribution using typical fluence levels may underestimate the cross section and on-orbit event rate.

Single Event Effects (SEE)↗

New dynamic FET logic and serial memory circuits for VLSI GaAs technology

The complexity of GaAs field effect transistor (FET) very large scale integration (VLSI) circuits is limited by the maximum power dissipation while the uniformity of the device parameters determines the functional yield. In this work, digital GaAs FET circuits are presented that eliminate the DC power dissipation and reduce the area to 50% of that of the conventional static circuits. Its larger tolerance to device parameter variations results in higher functional yield.

Eldin, A. G.↗

Infrascope: Full-Spectrum Phonocardiography With Automated Signal Analysis Report

Physicians have used the stethoscope to listen to heart sounds for over 150 years. During this time the stethoscope has remained nearly unchanged. While the device is inexpensive, simple and easy to use, it has shortcomings as a diagnostic tool. It is dependent on human hearing to detect the complex sounds made by the heart, and human memory to analyze them. There also has been a significant decline in the use of stethoscope, at least in part because of the availability of technologies such as the echocardiogram, which can provide imaging and blood flow through the heart chambers. However, echocardiography can be complex, costly and time consuming and requires the need for a specialist, all of which delay the diagnosis and increase the cost of patient evaluation. Even with the availability of echocardiogram devices such as the handheld pocket ultrasound, diagnosing heart problems can still be difficult. The Infrascope is a new device that resembles a traditional stethoscope and is simple to use. In addition, the Infrascope offers greater sensitivity and a wider range of frequencies heard by the human ear, <20Hz than a traditional stethoscope can detect. Through automated analysis of the full spectrum of heart sounds, it has the potential to improve diagnostic accuracy while reducing the need for referrals, allowing primary care physicians to practice better medicine at the bedside.

Infrasounds↗

Design, processing, and testing of LSI arrays for space station

At wafer probe, units of the TA6567 circuit, a beam leaded COS/MOS/SOS 256-bit RAM, were demonstrated to be functionally perfect. An aluminum gate current-sense version and a silicon-gate voltage-sense version of this memory were developed. Initial base line data for the beam lead SOS process using the TA5388 circuit show the stability of the dc device characteristics through the beam lead processing.

Schneider, W. C.↗

Deployment Mechanism for the Space Technology 5 Micro Satellite

Space Technology 5 (ST5) is a technology mission that will send three spin-stabilized, 25-kg satellites into a highly elliptical Earth orbit. Each of these satellites must be deployed separately from the same launch vehicle with a spin rate of 3.4 rads (32.4 rpm). Because of the satellite's small size and the requirement to achieve its mission spin rate on deploy, typical spin table, pyrotechnic deployment devices or spin up thrusters could not be used. Instead, this new mechanism design employs a "Frisbee" spin up strategy with a shape memory alloy actuated Pinpuller to deploy each satellite. The mechanism has undergone several design and test iterations and has been successfully qualified for flight.

Rossoni, Peter↗

Deployment Mechanism for the Space Technology 5 Micro Satellite

Space Technology 5 (ST5) is a technology mission that will send three spin-stabilized, 25-kg satellites into a highly elliptical Earth orbit. Each of these satellites must be deployed separately from the same launch vehicle with a spin rate of 3.4 rad/s (32.4 rpm). Because of the satellite's small size and the requirement to achieve its mission spin rate on deploy, typical spin table, pyrotechnic deployment devices or spin up thrusters could not be used. Instead, this new mechanism design employs a 'Frisbee' spin up strategy with a shape memory alloy actuated Pinpuller to deploy each satellite. The mechanism has undergone several design and test iterations and has been successfully qualified for flight.

Rossoni, Peter↗

Initial SEE Testing of Maestro

We have reported on initial SEE sensitivity of the full 49-core Maestro device. Supporting the low-level structures and qualitative system observation goals of phase 1 of testing. Observed sensitivities found to be consistent with Boeing predictions. Highlighted by the L1 data cache sensitivity which drives the rates on the current Maestro device. Presented details to the hardware and software setups that show where the limitations - highlighting future work. Key future work includes testing with memory and IO ports.

cache sensitivity↗

Coordination and establishment of centralized facilities and services for the University of Alaska ERTS survey of the Alaskan environment

The author has identified the following significant results. Specifications have been prepared for the engineering design and construction of a digital color display unit which will be used for automatic processing of ERTS data. The color display unit is a disk refresh memory with computer interfaced input and a color cathode ray tube output display. The system features both analog and digital post disk data manipulation and a versatile color coding device suitable for displaying not only images, but also computer generated graphics such as diagrams, maps, and overlays. Input is from IBM compatible 9 track, 800 BPI tapes, as generated by an IBM 360 computer. ERTS digital tapes are read into the 360, where various analyses such as maximum likelihood classification are performed and the results are written on a magnetic tape which is the input to the color display unit. The greatest versatility in the data manipulation area is provided by the minicomputer built into the color display unit, which is off-line from the main 360 computer. The minicomputer is able to read any line from the refresh disk and place it in its 4K-16 bit memory. Considerable flexibility is available for post-processing enhancement of images by the investigator.

Belon, A. E.↗

Device for Temporal Measurement of Loads in Parachute Suspension Systems

In order to understand the distribution of loads in parachutes, the NASA Low Density Supersonic Decelerators (LDSD) project developed a wireless instrument to measure loads in the parachute suspension lines. The load cells are titanium links that are connected in the primary structural load path of the parachute system. Strain gages measure the elongation of the links and an onboard data acquisition system records the data to ash memory. The load cells have onboard power, and include a radio transceiver that is used to receive timing information. The load cells are designed to be interfaced with cordage, packed in a parachute bag, and deployed with a standard parachute deployment. The devices are triggered passively during the deployment of the parachute. Prototype devices with a mass of 100 grams and a load capability of 16,000 lbs were built as a proof of concept.

Brandeau, Erich J.↗

Low cost omega navigation receiver

The development of a low cost Omega navigation receiver is discussed. Emphasis is placed on the completion and testing of a modular, multipurpose Omega receiver which utilizes a digital memory-aided, phase-locked loop to provide phase measurement data to a variety of applications interfaces. The functional units contained in the prototype device are described. The receiver is capable of receiving and storing phase measurements for up to eight Omega signals and computes two switch-selectable lines of position, displaying this navigation data in chart-recorded form.

Lilley, R. W.↗

A molecular shift register based on electron transfer

An electronic shift-register memory at the molecular level is described. The memory elements are based on a chain of electron-transfer molecules and the information is shifted by photoinduced electron-transfer reactions. This device integrates designed electronic molecules onto a very large scale integrated (silicon microelectronic) substrate, providing an example of a 'molecular electronic device' that could actually be made. The design requirements for such a device and possible synthetic strategies are discussed. Devices along these lines should have lower energy usage and enhanced storage density.

Hopfield, J. J.↗

Molecular Electronic Shift Registers

Molecular-scale shift registers eventually constructed as parts of high-density integrated memory circuits. In principle, variety of organic molecules makes possible large number of different configurations and modes of operation for such shift-register devices. Several classes of devices and implementations in some specific types of molecules proposed. All based on transfer of electrons or holes along chains of repeating molecular units.

Beratan, David N.↗

Autonomous Science Decision Making for Mars Sample Return

In the near future NASA intends to explore Mars in preparation for a sample return mission using robotic devices such as landers, rovers, orbiters, airplanes, and/or balloons. Such platforms will likely carry imaging devices to characterize the surface morphology, and a variety of analytical instruments intended to evaluate the chemical and mineralogical nature of the environment(s) that they encounter. Historically, mission operations have involved the following sequence of activities: (1) return of scientific data from the vehicle; (2) evaluation of the data by space scientists; (3) recommendations of the scientists regarding future mission activity; (4) transmission of commands to the vehicle to achieve this activity; and (5) new activity by the vehicle in response to those commands. This is repeated for the duration of the mission, with command opportunities once or perhaps twice per day. In a rapidly changing environment, such as might be encountered by a rover traversing hundreds of meters a day or an airplane soaring over several hundred of kilometers, this traditional cycle of data evaluation and commands is not amenable to rapid long range traverses, discovery of novelty, or rapid response to any unanticipated situations. In addition, to issues of response time, the nature of imaging and/or spectroscopic devices are such that tremendous data volumes can be acquired, for example during a traverse. These data volumes can rapidly exceed on-board memory capabilities prior to an opportunity to transmit it to Earth.

Roush, Ted L.↗