Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water Interplays during Dysprosium Electrodeposition in Pyrrolidinium Ionic Liquid: Deconvoluting the Pros and Cons for Rare Earth Metallization

The electrochemical production of rare earth metals (REMs) in ionic liquids (ILs) has received much attention as a promising, sustainable and replacement to the molten salt electrolysis. Water additives have been recently suggested as a strategy to overcome the limitations of the ionic liquid process, but without complete assessment of its overall viability for the REMs production. In this regard, a full investigation of water impact on dysprosium (Dy) electrodeposition in pyrrolidinium triflate (BMPyOTf) ionic liquid was carried out. Water introduction was revealed to involve an interplay of implications on the electrodeposition process, including coordination, speciation, reduction pathways, interfacial dynamics, nucleation and metal stability and purity. In highly dry conditions, the reduction occurs at very negative potentials (-3.3V) in a consecutive pathway, resulting in negligible metal electrodeposition (low rate and efficiency) at the electrode surface. Initial water introduction (<30% molar fraction) leads to partitioning of the Dy complex between water and IL coordinated speciation, giving rise to an additional wave at more positive potentials (-2.4V). Probing and quantification of the heterogeneous Dy speciation by spectroscopic analyses enabled the uncovering of the reduction mechanism and accurate evaluation of the mass transport properties. While lowering the reduction thermodynamics, water addition also improved the nucleation, deposition rate and faradaic efficiency. In spite of these benefits, stripping voltammetric analysis also indicated substantial chemical reactivity of the deposited Dy metal with water additives and/or electrolyte components, under extended timescales. Surface characterization of the obtained product confirmed limited Dy metal stability (mostly oxidized/fluorinated) and purity (~60%) in the studied system. Moreover, high water introduction (>30% molar fraction) was shown to trigger a fast hydrogen evolution reaction (HER), downgrading the robustness of system efficiency. We report the overall impact of water additives seems to engender both promoting and mitigating effects on the Dy electrodeposition process, making the case for more innovative strategies to be sought.

36 MATERIALS SCIENCE↗

WO 3 /CuWO 4 Ratio Controls Open-Circuit Photovoltage and Photocurrent in Type II Heterojunction Solar Fuel Photoelectrodes

WO 3 /CuWO 4 photoelectrodes for the oxygen evolution reaction benefit from a type II heterojunction for charge separation. However, the impact of the WO 3 /CuWO 4 ratio on the photocurrent and the photovoltage is not clear. To probe the effect of composition, Cu x W 1-x O y thin films with variable W:Cu ratio were prepared on FTO by reactive magnetron co-sputtering of W and Cu, followed by air annealing at 500ºC. EDS, XRD, Rietveld refinement, and Raman spectroscopy confirm the presence of crystalline WO 3 and CuWO 4 in the W rich films and increasing amounts of amorphous copper oxides in the Cu rich films. Bandgaps were determined by optical absorption spectroscopy, surface photovoltage spectroscopy (SPS), and photoaction spectra and are found to decrease from 2.7 eV to 1.2 eV with increasing copper oxide content. SPS reveals n-type semiconductor photoanode behavior for WO 3 /CuWO 4 samples and p-type photocathode behavior for CuO x rich films. Photoelectrochemical experiments confirm stable water oxidation with Faraday efficiency near unity for all W rich films and photocurrents that are increasing with CuWO 4 content. Optimal performance is seen for WO 3 /CuWO 4 mixed phases containing 47-75 mass% CuWO 4 . These compositions maximize charge separation at the type II heterojunction interface between the two materials. Additionally, according to incident photon to current efficiency (IPCE) data, the WO 3 improves photon conversion below 350 nm, while CuWO 4 improves conversion at 450-525 nm. Overall, this work shows for the first time how the WO 3 /CuWO 4 ratio controls the photovoltage and the photocurrent in type II heterojunction solar fuel photoelectrodes, and how copper oxides in the copper rich films severely degrade the performance. Furthermore, these results are useful in the context of bulk-heterojunction electrodes for the conversion of solar energy into fuels.

CuWO4↗

Search for brown dwarfs in IC 1396 with Subaru HSC: interpreting the impact of environmental factors on substellar population

ABSTRACT Young stellar clusters are predominantly the hub of star formation and hence, ideal to perform comprehensive studies over the least explored substellar regime. Various unanswered questions like the mass distribution in brown dwarf regime and the effect of diverse cluster environment on brown dwarf formation efficiency still plague the scientific community. The nearby young cluster, IC 1396 with its feedback-driven environment, is ideal to conduct such study. In this paper, we adopt a multiwavelength approach, using deep Subaru HSC along with other data sets and machine learning techniques to identify the cluster members complete down to ∼ 0.03 M⊙ in the central 22 arcmin area of IC 1396. We identify 458 cluster members including 62 brown dwarfs which are used to determine mass distribution in the region. We obtain a star-to-brown dwarf ratio of ∼ 6 for a stellar mass range 0.03–1 M⊙ in the studied cluster. The brown dwarf fraction is observed to increase across the cluster as radial distance from the central OB-stars increases. This study also compiles 15 young stellar clusters to check the variation of star-to-brown dwarf ratio relative to stellar density and ultraviolet (UV) flux ranging within 4–2500 stars pc−2 and 0.7–7.3 G0, respectively. The brown dwarf fraction is observed to increase with stellar density but the results about the influence of incident UV flux are inconclusive within this range. This is the deepest study of IC 1396 as of yet and it will pave the way to understand various aspects of brown dwarfs using spectroscopic observations in future.

Gupta, Saumya (ORCID:0000000161843958)↗

Low temperature polyolefin deconstruction via tandem cracking-hydrogenation

The use of aluminum chloride in dichloromethane to crack polyolefin chains in tandem with alkylation of the resulting products has been previously reported as an efficient polyolefin recycling route. Building off this work, we report that a tandem cracking-hydrogenation system also efficiently converts polyolefins into gasoline-range light alkanes at mild temperatures without needing a hydrocarbon co-reactant. This Lewis acid and hydrogenation bifunctional system uses anhydrous aluminum chloride as the acid catalyst and Pd/C as a hydrogenation catalyst to achieve nearly 80 % conversion of low-density polyethylene (LDPE) at 70 °C in three hours, with 90+% selectivity towards gasoline-range (C 4 -C 12 ) branched alkanes. By combining the endothermic cracking reaction with the exothermic hydrogenation reaction, the thermodynamic limitations to low-temperature polyolefin deconstruction can be overcome. In using hydrogenation instead of alkylation, the system’s carbon efficiency is greatly improved, the cost of the reactants is reduced and the overall mass of both reactants and products reduced as well.

Alkylation↗

A fast and accurate modeling approach for water and steam thermodynamics with practical applications in district heating system simulation

In U.S. district heating (DH) systems, steam is the most common heat transport medium. Industry demand for new advanced modeling capabilities of complete steam DH systems is increasing; however, the existing models for water/steam thermodynamics are too slow for large system simulations because of computationally expensive algebraic loops that require the solution to nonlinear systems of equations. For practical applications, this work presents a novel split-medium approach that implements numerically efficient liquid water models alongside various water/steam models, breaking costly algebraic loops by decoupling mass and energy balance equations. New component models for steam DH systems are also presented. We implemented the models in the equation based Modelica language and evaluated accuracy and computing speed across multiple scales: from fundamental thermodynamic properties to complete districts featuring 10 to 200 buildings. Compared to district models with the IF97 water/steam model and equipment models from the Modelica Standard Library, the new implementation improves the scaling rate for large districts from cubic to quadratic with negligible compromise to accuracy. Additionally, for an annual simulation with 180 buildings, this translates to a computing time reduction from 33 to 1-1.5 h. These results are critically important for industry practitioners to simulate steam DH systems at large scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effective removal of trace-level toxic metals from flue gas desulfurization wastewater using SiO 2 supported hydrogel sorbent

Flue gas desulfurization (FGD) wastewater generated from coal-fired power plants contain potentially harmful heavy metal pollutants that pose a threat to public health and clean water. In this work, we present a water stable polyethylenimine-n,n’-methylenebisacrylamide (PEI-MBAA) functionalized SiO 2 solid sorbent material (PMS-1.2/1/4) and investigate its metal adsorption kinetics, selectivity, regenerability, and space velocity. The kinetic studies of six of the toxic heavy metals (As, Cd, Cr, Pb, Se, and Hg) prepared with single elements in Milli-Q water showed the effect of chemical bonding and intraparticle mass transfer resistance on the sorption process. The selectivity studies demonstrated the significant adsorption efficiency toward trace-level heavy metals (Se, Cd, U, Al, etc.) from authentic industrial FGD wastewater. Through five consecutive adsorption–desorption cycles with the FGD (uptake)-citrate (release)-based buffer pair, the sorbent showed high heavy metal removal ability and good reusability. The maximum flow rate for the removal of Se from industrial FGD wastewater was determined to be as high as 8 bed volumes/minute of the sorbent bed. Finally, the results demonstrate the PMS-1.2/1.4 sorbent is a promising candidate for the removal of heavy metals from practical aqueous solutions.

36 MATERIALS SCIENCE↗

Narrowing the band gap and suppressing electron–hole recombination in β-Fe 2 O 3 by chlorine doping

Here, the effects of halogen (F, Cl, Br, I, and At) doping in the direct-band-gap β-Fe 2 O 3 semiconductor on its band structures and electron–hole recombination have been investigated by density functional theory. Doping Br, I, and At in β-Fe 2 O 3 leads to transformation from a direct-band-gap semiconductor to an indirect-band-gap semiconductor because their atomic radii are too large; however, F- and Cl-doped β-Fe 2 O 3 remain as direct-band-gap semiconductors. Due to the deep impurity states of the F dopant, this study focuses on the effects of the Cl dopant on the band structures of β-Fe 2 O 3 . Two impurity levels are introduced when Cl is doped into β-Fe 2 O 3 , which narrows the band gap by approximately 0.3 eV. After doping Cl, the light-absorption edge of β-Fe 2 O 3 redshifts from 650 to 776 nm, indicating that its theoretical solar to hydrogen efficiency for solar water splitting increases from 20.6% to 31.4%. In addition, the effective mass of the holes in halogen-doped β-Fe 2 O 3 becomes significantly larger than that in undoped β-Fe 2 O 3 , which may suppress electron–hole recombination.

30 DIRECT ENERGY CONVERSION↗

Prioritizing circular economy strategies for sustainable PV deployment at the TW scale

Global decarbonization requires an unprecedented scale-up of photovoltaic (PV) manufacturing and deployment. The material demand and eventual end of life management associated with multi-TW scale deployment poses many challenges. Circular Economy (CE) and it's associated R-Actions (Reduce, Reuse, Recycle) have been proposed to mitigate end of life management and material sourcing concerns. However, CE metrics typically focus on a single product and only consider mass, excluding energy flows. This work leverages the PV in Circular Economy (PV ICE) tool to quantify the deployment, mass, and energy impacts of R-Actions and proposed sustainable PV designs in the context of achieving energy transition deployment goals (75 TW in 2050). 13 module scenarios are established and evaluated across 6 capacity, mass and energy metrics to identify tradeoffs and priorities. We find that increasing module efficiency can reduce near-term material demands up to 30% and improve energy metrics by up to 9%. Material circularity (recycling) can minimize lifecycle wastes and reduce material demands at the cost of higher energy demands. Increasing module lifetime, including reliability improvements and reuse strategies, is effective at reducing both material (>10%) and energy demands (24%). Uniquely, lifetime improvements maximize benefits and minimize the harms across all six metrics while achieving multi-TW scale deployment.

Photovoltaics↗

Ly α emission in low-redshift most metal-deficient compact star-forming galaxies

ABSTRACT We present observations with the Cosmic Origins Spectrograph onboard the Hubble Space Telescope of nine most metal-deficient compact star-forming galaxies with oxygen abundances 12 + log(O/H) = 6.97–7.23, redshifts z = 0.02811–0.13320, and stellar masses M⋆ ≤ 107 M⊙. We aim to study the properties of Ly α emission in these extremely metal-deficient objects. We find that all nine galaxies are Ly α emitters (LAEs). We examine various relations between the Ly α escape fraction fesc(Ly α) and other characteristics – such as absolute UV magnitude, oxygen abundance, O32 ratio, stellar mass, Lyman-alpha luminosity, and equivalent width EW(Ly α), ionizing photon production efficiency ξion and velocity separation Vsep between the two peaks of the Ly α profile – of a large sample of LAEs, including our lowest metallicity galaxies and other objects from the literature. We find a relatively tight correlation between fesc(Ly α) and two characteristics, EW(Ly α) and Vsep, whereas no correlation is found between fesc(Ly α) and the oxygen abundance. We also find a relatively tight relation between the Ly α and LyC escape fractions. We propose to use the latter relation to estimate indirectly the escaping ionizing radiation in LAEs, when direct measurements of LyC emission are not possible. We show that the global properties of low-z LAEs are very similar to those of z > 6 galaxies. They are thus ideal local proxies for studying physical processes during the epoch of reionization of the Universe.

Izotov, Y. I. (ORCID:0000000214166082)↗

Data for The Leaf Economics Spectrum of Triploid and Tetraploid C4 Grass Miscanthus x giganteus

The leaf economics spectrum (LES) describes multivariate correlations in leaf structural, physiological and chemical traits, originally based on diverse C3 species grown under natural ecosystems. However, the specific contribution of C4 species to the global LES is studied less widely. C4 species have a CO2 concentrating mechanism which drives high rates of photosynthesis and improves resource use efficiency, thus potentially pushing them towards the edge of the LES. Here, we measured foliage morphology, structure, photosynthesis, and nutrient content for hundreds of genotypes of the C4 grass Miscanthus × giganteus grown in two common gardens over two seasons. We show substantial trait variations across M. × giganteus genotypes and robust genotypic trait relationships. Compared to the global LES, M. × giganteus genotypes had higher photosynthetic rates, lower stomatal conductance, and less nitrogen content, indicating greater water and photosynthetic nitrogen use efficiency in the C4 species. Additionally, tetraploid genotypes produced thicker leaves with greater leaf mass per area and lower leaf density than triploid genotypes. By expanding the LES relationships across C3 species to include C4 crops, these findings highlight that M. × giganteus occupies the boundary of the global LES and suggest the potential for ploidy to alter LES traits.

Biomass Analytics↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of saturated thermal conduction on clouds in a hot plasma

We numerically investigate the internal evolution of multiphase clouds, which are at rest with respect to an ambient, highly ionized medium (HIM) representing the hot component of the circumgalactic medium. Time-dependent saturated thermal conduction and its implications like condensation rates and mixing efficiency are assessed in multiphase clouds. Our simulations are carried out by using the adaptive mesh refinement code FLASH. The model clouds are initially in both hydrostatic and thermal equilibrium and are in pressure balance with the HIM. Thus, they have steep gradients in both temperature and density at the interface to HIM leading to non-negligible thermal conduction. Several physical processes are considered numerically or semi-analytically: thermal conduction, radiative cooling and external heating of gas, self-gravity, mass diffusion, and dissociation of molecules and ionization of atoms. It turns out that saturated thermal conduction triggers a continuous condensation irrespective of cloud mass. Dynamical interactions with ambient HIM all relate to the radial density gradient in the clouds: (1) mass flux due to condensation is the higher the more homogeneous the clouds are; (2) mixing of condensed gas with cloud gas is easier in low-mass clouds, because of their shallower radial density gradient; and thus (3) accreted gas is distributed more efficiently. A distinct and sub-structured transition zone forms at the interface between cloud and HIM, which starts at smaller radii and is much narrower as deduced from analytical theory.

79 ASTRONOMY AND ASTROPHYSICS↗