Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Manual”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SMAnalytics Automated Shape Memory Test Analysis Software User's Manual: UCFTC, UPER, and DSC Test Methods, Version 1.0.2

Over the course of 60 years of shape memory alloy research and development, the properties of these alloys have been measured using various testing methods, which are often customized by the organization performing the test. However, commercial adoption of shape memory alloys in aeronautic actuator applications requires reducing property uncertainty through standardizing test methods. Historically, differential scanning calorimetry (DSC) has been used to measure transformation temperatures under stress-free conditions. This testing method is well established, and tests are run under the applicable standard, ASTM F2004-17: Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis. Two other test methods for measuring strains and transformation temperatures under constant load or free recovery after prestraining have only recently been standardized—ASTM E3097: Standard Test Method for Mechanical Uniaxial Constant Force Thermal Cycling of SMAs (UCFTC) and ASTM E3098: Standard Test Method for Mechanical Uniaxial Pre-Strain and Thermal Free Recovery of SMAs (UPFR). These standards represent a critical step forward in producing reliable material property data for the use of these alloys in aeronautics and other commercial areas. However, no standard programs or software packages were previously available for postprocessing UCFTC- and UPFR-type test data to extract property data. Each organization that performed the testing analyzed data using its own custom manual methods, such as using a plot and a straight edge, spreadsheet plotting methods, or custom code routines, to extract the required values for strains, stresses, and transformation temperatures. SMAnalytics represents the first publicly available uniform software package for processing data generated using the DSC, UCFTC, and UPFR test methods, as well as many modifications of these methods, including loading in martensite versus austenite and performing multiple thermal cycles at stress. In doing so, it provides a tool for reducing potential error or variability in the measured values due to the precision of the technique used and person-to-person variability. It is also expected that this automated data-parsing tool can accelerate the data analysis phase of the test campaign, especially for large data files. This User’s Manual describes how the SMAnalytics software works and the method for its use.

Shape Memory Alloy↗

Nevada National Security Site Radiological Control Manual

Please have this STIP assigned, documented, and recorded in OSTI as Report Number DOE/NV/03624--0257 Revision 1 and Author as Radiological Control Managers' Council. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO). (Activities conducted under the purview of the U.S. Department of Energy, Office of Environmental Management Nevada[(EM Nevada] may require additional approval authorities as described in the EM Nevada Prime Contractor’s implementation plan.) Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, “Occupational Radiation Protection.” This manual represents policies, guidelines, and best practices for implementing the DOE/NV/03624--0082, “Nevada National Security Site Radiation Protection Program,” (NNSS RPP) according to the requirements of 10 CFR 835.

61 RADIATION PROTECTION AND DOSIMETRY↗

Risk Analysis of Radiological Release from Pu-238 Targets During Manual Handling

Pu-238 Isotope Production Targets are routinely installed in the Advanced Test Reactor (ATR) core, transferred, and stored in the spent fuel canal. These evolutions involve manual handling and manipulation of the targets underwater using long handled tools. The ATR Safety Analysis Report (SAR) postulates a design basis accident which results in damage from manual manipulation of targets, and radiological consequences must be determined for receptors inside the reactor facility, as well as public receptors. This presentation presents the analysis used to determine the radiological consequences due to potential target damage in the ATR canal. The analysis considered radionuclide release fractions, damage ratios for handling evolutions, and entrainment of radionuclides in the canal water.

Advanced Test Reactor↗

Demonstration and Validation Assets: User Manual Development

This report documents the development of a database-supported user manual for DEMVAL assets in the NSTI area of operations and focuses on providing comprehensive user information on DEMVAL assets serving businesses with national security technology applications in southern New Mexico. The DEMVAL asset program is being developed as part of the NSPP, funded by both Department of Energy (DOE) and NNSA. This report describes the development of a comprehensive user manual system for delivering indexed DEMVAL asset information to be used in marketing and visibility materials and to NSTI clients, prospective clients, stakeholders, and any person or organization seeking it. The data about area DEMVAL asset providers are organized in an SQL database with updateable application structure that optimizes ease of access and customizes search ability for the user.

99 GENERAL AND MISCELLANEOUS↗

DOE nuclear material packaging manual: storage container requirements for plutonium oxide materials

Loss of containment of nuclear material stored in containers such as food-pack cans, paint cans, or taped slip lid cans has generated concern about packaging requirements for interim storage of nuclear materials in working facilities such as the plutonium facility at Los Alamos National Laboratory (LANL). In response, DOE has recently issued DOE M 441.1 'Nuclear Material Packaging Manual' with encouragement from the Defense Nuclear Facilities Safety Board. A unique feature compared to transportation containers is the allowance of filters to vent flammable gases during storage. Defining commonly used concepts such as maximum allowable working pressure and He leak rate criteria become problematic when considering vented containers. Los Alamos has developed a set of container requirements that are in compliance with 441.1 based upon the activity of heat-source plutonium (90% Pu-238) oxide, which bounds the requirements for weapons-grade plutonium oxide. The pre and post drop-test He leak rates depend upon container size as well as the material contents. For containers that are routinely handled, ease of handling and weight are a major consideration. Relatively thin-walled containers with flat bottoms are desired yet they cannot be He leak tested at a differential pressure of one atmosphere due to the potential for plastic deformation of the flat bottom during testing. The He leak rates and He leak testing configuration for containers designed for plutonium bearing materials will be presented. The approach to meeting the other manual requirements such as corrosion and thermal degradation resistance will be addressed. The information presented can be used by other sites to evaluate if their conditions are bounded by LANL requirements when considering procurement of 441.1 compliant containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

User's Manual for BEST-Dairy: Benchmarking and Energy/water-Saving Tool (BEST) for the Dairy Processing Industry (Version 1.2)

This User's Manual summarizes the background information of the Benchmarking and Energy/water-Saving Tool (BEST) for the Dairy Processing Industry (Version 1.2, 2011), including'Read Me' portion of the tool, the sections of Introduction, and Instructions for the BEST-Dairy tool that is developed and distributed by Lawrence Berkeley National Laboratory (LBNL).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal{sup ®} Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HOPSPACK 2.0 user manual.

HOPSPACK (Hybrid Optimization Parallel Search PACKage) solves derivative-free optimization problems using an open source, C++ software framework. The framework enables parallel operation using MPI or multithreading, and allows multiple solvers to run simultaneously and interact to find solution points. HOPSPACK comes with an asynchronous pattern search solver that handles general optimization problems with linear and nonlinear constraints, and continuous and integer-valued variables. This user manual explains how to install and use HOPSPACK to solve problems, and how to create custom solvers within the framework.

97 MATHEMATICS AND COMPUTING↗

TALENT User's Manual

The Ground-Based Monitoring R and E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. The software tool used to capture and analyze the data collected from testing is called TALENT: Test and Analysis Evaluation Tool. This document is the manual for using TALENT. Other reports document the testing procedures that are in place (Kromer, 2007) and the algorithms employed in the test analysis (Merchant, 2011).

99 GENERAL AND MISCELLANEOUS↗

User Manual for the PROTEUS Mesh Tools

This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status and Opportunities for Improving the Consistency of Technical Reference Manuals

Across the United States, energy-efficiency program administrators rely on Technical Reference Manuals (TRMs) as sources for calculations and deemed savings values for specific, well-defined efficiency measures. TRMs play an important part in energy efficiency program planning by providing a common and consistent source for calculation of ex ante and often ex post savings. They thus help reduce energy-efficiency resource acquisition costs by obviating the need for extensive measurement and verification and lower performance risk for program administrators and implementation contractors. This paper considers the benefits of establishing region-wide or national TRMs and considers the challenges of such undertaking due to the difficulties in comparing energy savings across jurisdictions. We argue that greater consistency across TRMs in the approaches used to determine deemed savings values, with more transparency about assumptions, would allow better comparisons in savings estimates across jurisdictions as well as improve confidence in reported efficiency measure savings. To support this thesis, we review approaches for the calculation of savings for select measures in TRMs currently in use in 17 jurisdictions. The review reveals differences in the saving methodologies, technical assumptions, and input variables used for estimating deemed savings values. These differences are described and their implications are summarized, using four, common energy-efficiency measures as examples. Recommendations are then offered for establishing a uniform approach for determining deemed savings values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CREST - Cost of Renewable Energy Spreadsheet Tool: A Model for Developing Cost-based Incentives in the United States (User Manual Version 1)

This user manual helps model users understands how to use the CREST model to support renewable energy incentives, FITs, and other renewable energy rate-setting processes. It reviews the spreadsheet tool, including its layout and conventions, offering context on how and why it was created. It also provides instructions on how to populate the model with inputs that are appropriate for a specific jurisdiction’s policymaking objectives and context. And, it describes the results and outlines how these results may inform decisions about long-term renewable energy support programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

COE1 Calorimeter Operations Manual

The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RADTRAN 6 Technical Manual

This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation and Maintenance Manual for the Remote-Handled Low-Level Waste Facility Potable Water System (PWS #6120030)

The document is an Operations and Maintenance Manual for the Remote Handled Low Level Waste Disposal Facility (RHLLW) potable water system. This document is required by the State of Idaho Department of Environmental Quality. The document defines the system, components, interfaces with ATR, operations of the system, contains operating procedures and log sheets, component manufacturer sheets showing compliance with regulations and also contains signed Preventive Maintenance Justification forms for applicable components of the potable water system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rattlesnake: User Manual

The drafted user manual for Rattlesnake, the multigroup radiation transport application based on MOOSE.

97 MATHEMATICS AND COMPUTING↗

SAM Theory Manual

The System Analysis Module (SAM) is an advanced and modern system analysis tool under development at Argonne National Laboratory for advanced non-LWR reactor safety analysis. It aims to provide fast-running, modest-fidelity, whole-plant transient analyses capabilities, which are essential for fast turnaround design scoping and engineering analyses of advanced reactor concepts. While SAM is being developed as a system-level modeling and simulation tool, advanced modeling techniques being implemented include a reduced-order three-dimensional module, pseudo 3-D conjugate heat transfer modeling in reactor core, flexible and multi-scale modeling of heat transfer between fluid and structures, in addition to the advances in software environments and design, and numerical methods. SAM aims to be a generic system-level safety analysis tool for advanced non-LWRs, including Liquid-Metal-cooled fast Reactors (LMR), Molten Salt Reactors (MSR), Fluoride-salt-cooled High- temperature Reactors (FHR), and High-Temperature Gas-cooled Reactors (HTGR). SAM takes ad- vantage of advances in physical modeling, numerical methods, and software engineering to enhance its user experience and usability. It utilizes an object-oriented computational framework (MOOSE), and its underlying meshing and finite-element library and linear and non-linear solvers, to leverage the modern advanced software environments and numerical methods. This document provides the theoretical and technical basis of the code to help users understand the underlying physical models (such as governing equations, closure models, and component models), system modeling approaches, numerical discretization and solution methods, and the overall capabilities in SAM. As new code capabilities and features are added, the SAM Theory Manual will be updated periodically to keep it consistent with the state of the development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗