Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Analytical electron microscopy of LDEF impactor residues

The LDEF contained 57 individual experiment trays or tray portions specifically designed to characterize critical aspects of meteoroid and debris environment in low-Earth orbit (LEO). However, it was realized from the beginning that the most efficient use of the satellite would be to characterize impact features from the entire surface of the LDEF. With this in mind particular interest has focused on common materials facing in all 26 LDEF facing directions; among the most important of these materials has been the tray clamps. Therefore, in an effort to better understand the nature and flux of particulates in LEO, and their effects on spacecraft hardware, we are analyzing residues found in impact features on LDEF tray clamp surfaces. This paper summarizes all data from 79 clamps located on Bay A & B of the LDEF. We also describe current efforts to characterize impactor residues recovered from the impact craters, and we have found that a low, but significant, fraction of these residues have survived in a largely unmelted state. These residues can be characterized sufficiently to permit resolution of the impactor origin. We have concentrated on the residue from chondritic interplanetary dust particles (micrometeoroids), as these represent the harshest test of our analytical capabilities.

Bernhard, Ronald P.↗

Nondestructive monitoring damage in composites using scanning laser acoustic microscopy

Several Nicalon fiber reinforced LAS (lithium alumino-silicate) glass matrix composites were tested to study the relation between the residual strength and the different amounts of damage. The samples were fatigued by four-point cyclic loading at a 5 Hz rate at 500 C for a different number of cycles. 10 MHz scanning laser acoustic microscope (SLAM) images were taken to monitor damage on the samples. Our SLAM results indicate that there were defects already existing throughout the sample before fatigue, and the resultant damage pattern from fatigue could be related to the initial defect distribution in the sample. Finally, the fatigued samples were fractured and the residual strength data could not be explained by the cyclic fatigue alone. Rather, the damage patterns evident in the SLAM images were needed to explain the scatter in the data. The results show that SLAM is useful in nondestructively monitoring damage and estimating residual strength of fatigued ceramic composites.

Wey, A. C.↗

Scanning and Transmission Electron Microscopy of High Temperature Materials

Software and hardware updates to further extend the capability of the electron microscope were carried out. A range of materials such as intermetallics, metal-matrix composites, ceramic-matrix composites, ceramics and intermetallic compounds, based on refractory elements were examined under this research. Crystal structure, size, shape and volume fraction distribution of various phases which constitute the microstructures were examined. Deformed materials were studied to understand the effect of interfacial microstructure on the deformation and fracture behavior of these materials. Specimens tested for a range of mechanical property requirements, such as stress rupture, creep, low cycle fatigue, high cycle fatigue, thermomechanical fatigue, etc. were examined. Microstructural and microchemical stability of these materials exposed to simulated operating environments were investigated. The EOIM Shuttle post-flight samples were also examined to understand the influence of low gravity processing on microstructure. In addition, fractographic analyses of Nb-Zr-W, titanium aluminide, molybdenum silicide and silicon carbide samples were carried out. Extensive characterization of sapphire fibers in the fiber-reinforced composites made by powder cloth processing was made. Finally, pressure infiltration casting of metal-matrix composites was carried out.

Source record↗

Fundamental Studies of Solidification in Microgravity Using Real-Time X-Ray Microscopy

This research applies a state of the art X-ray Transmission Microscope, XTM, to image (with resolutions up to 3 micrometers) the solidification of metallic or semiconductor alloys in real-time. We have successfully imaged in real-time: interfacial morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid interface. We have also measured true local growth rates and can evaluate segregation structures in the solid; a form of in-situ metallography. During this study, the growth of secondary phase fibers and lamellae from eutectic and monotectic alloys have been imaged during solidification, in real-time, for the first time in bulk metal alloys. Current high resolution X-ray sources and high contrast X-ray detectors have advanced to allow systematic study of solidification dynamics and the resulting microstructure. We have employed a state-of-the-art sub-micron source with acceleration voltages of 10-100 kV to image solidification of metals. One useful strength of the XTM stems from the manner an image is formed. The radiographic image is a shadow formed by x-ray photons that are not absorbed as they pass through the specimen. Composition gradients within the specimen cause variations in absorption of the flux such that the final image represents a spatial integral of composition (or thickness). The ability to image these features in real-time enables more fundamental and detailed understanding of solidification dynamics than has previously been possible. Hence, application of this technique towards microgravity experiments will allow rigorous testing of critical solidification models.

Curreri, Peter A.↗

In-Situ X-Ray Microscopy of Phase and Composition Distributions in Metal Alloys During Solidification

This research applies a state of the art X-ray Transmission Microscope, to image the solidification of metallic or semiconductor alloys in real-time. By employing a hard x-ray source with sub-micron dimensions, resolutions of up to 3 gm can be obtained with magnifications of over 800 X. Specimen growth conditions were optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast. We have successfully imaged in real-time: interfacial morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid inter-face. We have also measured true local growth rates and can evaluate segregation structures in the solid; a form of in-situ metallography. Composition gradients within the specimen cause vafiations in absorption of the flux such that the final image represents a spatial integral of composition (or thickness). During this study, the growth of secondary phase fibers and lameilae from eutectic and monotectic alloys have been imaged during solidification, in real-time, for the first time in bulk metal alloys. Keywords: x-ray, microscope, solidification, microfocus, real-time, microstructure

Kaukler, William F.↗

Real-Time X-Ray Microscopy of Al-Cu Eutectic Solidification

Recent improvements in the resolution of the X-ray Transmission Microscope (XTM) for Solidification Studies provide microstructure feature detectability down to 5 micrometers during solidification. This presentation will show the recent results from observations made in real-time of the solid-liquid interfacial morphologies of the Al-CuAI2 eutectic alloy. Lamellar dimensions and spacings, transitions of morphology caused by growth rate changes, and eutectic grain structures are open to measurements. A unique vantage point viewing the face of the interface isotherm is possible for the first time with the XTM due to its infinite depth of field. A video of the solid-liquid interfaces seen in-situ and in real-time will be shown.

Kaukler, William F.↗

Microscopy of Analogs for Martian Dust and Soil

The upcoming Mars 2001 lander will carry an atomic force microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) payload. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase-contrast imaging. Phase imaging is an extension of tapping-mode AFM that provides nanometer-scale information about surface composition not revealed in the topography. Phase imaging maps the phase of the cantilever oscillation during the tapping mode scan, hence detecting variations in composition, adhesion, friction, and viscoelasticity. Because phase imaging highlights edges and is not affected by large-scale height differences, it provides for clearer observation of fine features, such as grain edges, which can be obscured by rough topography. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil and terrestrial basaltic glasses to determine the AFMOs ability to define particle shapes and sizes and grain-surface textures. The test materials include the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for Martian dust. The terrestrial samples are millimeter size basaltic glasses collected on Black Pointe at Mono Lake, just north of the Long Valley caldera in California. The basaltic glass formed by a phreatomagmatic eruption 13,000 years ago beneath a glacier that covered the Mono Lake region. Because basaltic glass formed by reworking of pyroclastic deposits may represent a likely source for Martian dunes, these basaltic glass samples represent plausible analogs to the types of particles that may be studied in sand dunes by the 01 lander and rover. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150-micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100-micron glass spherule, it was possible to define an extremely smooth surface.E Also visible on the surface of the glass spherule were chains of 100-nanometer- and-smaller impact melt droplets. Additional information is contained in the original extended abstract.

Anderson, M. A.↗

Apparatus for Direct Optical Fiber Through-Lens Illumination of Microscopy or Observational Objects

In one embodiment of the invention, a microscope or other observational apparatus, comprises a hollow tube, a lens mounted to the tube, a light source and at least one flexible optical fiber having an input end and an output end. The input end is positioned to receive light from the light source, and the output end is positioned within the tube so as to directly project light along a straight path to the lens to illuminate an object to be viewed. The path of projected light is uninterrupted and free of light deflecting elements. By passing the light through the lens, the light can be diffused or otherwise defocused to provide more uniform illumination across the surface of the object, increasing the quality of the image of the object seen by the viewer. The direct undeflected and uninterrupted projection of light, without change of direction, eliminates the need for light-deflecting elements, such as beam-splitters, mirrors, prisms, or the like, to direct the projected light towards the object.

Kadogawa, Hiroshi↗

Laboratory Investigation of the Growth and Crystal Structure of Nitric Acid Hydrates by Transmission Electron Microscopy (TEM)

A great deal of recent laboratory work has focussed on the characterization of the nitric acid hydrates, thought to be present in type I Polar Stratospheric Clouds (PSCs). Phase relationships and vapor pressure measurements (1-3) and infrared characterizations (4-5) have been made. However, the observed properties of crystalline solids (composition, melting point, vapor pressure, surface reactivity, thermodynamic stability, extent of solid solution with other components, etc.) are controlled by their crystal structure. The only means of unequivocal structural identification for crystalline solids is diffraction (using electrons, X-rays, neutrons, etc.). Other observed properties of crystalline solids, such as their infrared spectra, their vapor pressure as a function of temperature, etc. yield only indirect information about what phases are present, their relative proportions, or whether they are crystalline or amorphous.

Blake, David F.↗

Microscopy in Space Research: Learning More About Gravitational Effects on Living Systems

Investigators are using light, scanning and transmission electron microscopic (TEM) methods to investigate the effects of microgravity on the development, maintenance and aging of biological systems. The capabilities of the spacelab for life sciences research in space will be described. Among the many results to be discussed are the effects of microgravity on amphibian fertilization and early development, and on the rodent musculoskeletal and neural systems. Xenopus laevis eggs fertilized in space developed normally during and after an eight day spaceflight. Ultrastructural studies of rodent tissue demonstrated that spaceflight-induced atrophy of antigravity skeletal muscles renders muscle fibers susceptible to structural failure upon return to weight bearing postflight. Principle TEM changes in neuromuscular junctions are the decrease or absence of synaptic vesicles and degeneration of axon terminals. In bone, architectural rather than compositional changes may be the primary perturbation. Thus, many techniques used on Earth (such as density determinations) would not detect significant changes in bone strength. An increment in synaptic number and changes in synapse distribution occur in peripheral gravity sensors. There is a decrease in muscarinic cholinergic receptor density in the striatum. Striatal receptor changes suggest spaceflight-related alterations in motor activity. Opportunities for future life sciences research in space will be discussed.

Ross, Muriel D.↗

Electron Microscopy and Image Analysis for Selected Materials

This particular project was completed in collaboration with the metallurgical diagnostics facility. The objective of this research had four major components. First, we required training in the operation of the environmental scanning electron microscope (ESEM) for imaging of selected materials including biological specimens. The types of materials range from cyanobacteria and diatoms to cloth, metals, sand, composites and other materials. Second, to obtain training in surface elemental analysis technology using energy dispersive x-ray (EDX) analysis, and in the preparation of x-ray maps of these same materials. Third, to provide training for the staff of the metallurgical diagnostics and failure analysis team in the area of image processing and image analysis technology using NIH Image software. Finally, we were to assist in the sample preparation, observing, imaging, and elemental analysis for Mr. Richard Hoover, one of NASA MSFC's solar physicists and Marshall's principal scientist for the agency-wide virtual Astrobiology Institute. These materials have been collected from various places around the world including the Fox Tunnel in Alaska, Siberia, Antarctica, ice core samples from near Lake Vostoc, thermal vents in the ocean floor, hot springs and many others. We were successful in our efforts to obtain high quality, high resolution images of various materials including selected biological ones. Surface analyses (EDX) and x-ray maps were easily prepared with this technology. We also discovered and used some applications for NIH Image software in the metallurgical diagnostics facility.

Williams, George↗

Quantitative Analysis of Charge Injection and Discharging of Si Nanocrystals and Arrays by Electrostatic Force Microscopy

NASA requirements for computing and memory for microspacecraft emphasize high density, low power, small size, and radiation hardness. The distributed nature of storage elements in nanocrystal floating-gate memories leads to intrinsic fault tolerance and radiation hardness. Conventional floating-gate non-volatile memories are more susceptible to radiation damage. Nanocrystal-based memories also offer the possibility of faster, lower power operation. In the pursuit of filling these requirements, the following tasks have been accomplished: (1) Si nanocrystal charging has been accomplished with conducting-tip AFM; (2) Both individual nanocrystals on an oxide surface and nanocrystals formed by implantation have been charged; (3) Discharging is consistent with tunneling through a field-lowered oxide barrier; (4) Modeling of the response of the AFM to trapped charge has allowed estimation of the quantity of trapped charge; and (5) Initial attempts to fabricate competitive nanocrystal non-volatile memories have been extremely successful.

Bell, L. D.↗

Transmission Electron Microscopy of an In Situ Presolar Silicon Carbide Grain

We used a focused ion beam workstation to prepare ultra-thin sections of a presolar SiC grain. Our TEM studies indicate that the SiC formed by rapid vapor-phase condensation, trapping pre-existing graphite grains in random orientations. Additional information is contained in the original extended abstract.

Stroud, Rhonda M.↗

Determining the Biogenicity of Microfossils in the Apex Chert, Western Australia, Using Transmission Electron Microscopy

For over a decade, the oldest evidence for life on this planet has been microfossils in the 3.5 Ga Apex Chert in Western Australia. Recently, the biogenicity of these carbon-rich structures has been called into question through reanalysis of the local geology and reinterpretation of the original thin sections. Although initially described as a stratiform, bedded chert of siliceous clasts, the unit is now thought to be a brecciated hydrothermal vein chert. The high temperatures of a hydrothermal environment would probably have detrimental effects to early non-hyperthermophilic life, compared to that of a shallow sea. Conversely, a hydrothermal origin would suggest that if the microfossils were valid, they might have been hyperthermophilic. Apex Chert controversy. The Apex Chert microfossils were originally described as septate filaments composed of kerogen similar in morphology to Proterozoic and modern cyanobacteria. However new thin section analysis shows that these carbonaceous structures are not simple filaments. Many of the original microfossils are branched and have variable thickness when the plane of focus is changed. Hydrothermal alteration of organic remains has also been suggested for the creation of these strange morphologies. Another point of contention lies with the nature of the carbon material in these proposed microfossils. Kerogen is structurally amorphous, but transforms into well-ordered graphite under high pressures and temperatures. Raman spectrometry of the carbonaceous material in the proposed microfossils has been interpreted both as partially graphitized kerogen and amorphous graphite. However, these results are inconclusive, since Raman spectrometry cannot adequately discriminate between kerogen and disordered graphite. There are also opposing views for the origin of the carbon in the Apex Chert. The carbon would be biogenic if the proposed microfossils are indeed the remains of former living organisms. However, an inorganic Fischer- Tropsch-type synthesis is also a possible explanation for the formation of large-aggregate carbonaceous particles and could also account for the depletion of (13)C observed.

DeGregorio, B. T.↗

Transmission Electron Microscopy of Non-Etched Presolar Silicon Carbide

Our solar system formed from nuclei produced in earlier generations of stars. Mixing in the proto-solar nebula isotopically homogenized most of this material, but some grains, called presolar grains, retain their original isotopic composition. The isotopic properties of presolar SiC grains indicate that most of the grains formed in the outflows of carbon-rich Asymptotic Giant Branch (AGB) stars. The microstructure of these presolar grains reflects the conditions of the dust formation and subsequent alteration. Early microstructural studies of SiC grains obtained by acid dissolution from meteorites show that most isotopically anomalous SiC grains have the face-centered cubic b- SiC structure. However, Daulton et al. have shown that a small fraction of sub-micron presolar SiC grains are of the hexagonal 2H polytype (a-SiC). Although the harsh chemical treatments of these grains does not alter their crystal structure, significant alteration of the surface morphology of the grains due to the acid treatments has been observed. In addition, the acid treatments may preferentially remove cracked or fissured grains, and possible sub-grains, such as graphite. By studying SiC grains isolated by physical separation and found in situ, we attempt to obtain a more complete analysis of presolar SiC microstructures, including the surface morphology, in order to address the formation and processing history of the grains. In our prior work, we reported on one in situ SiC grain (hereafter CBIS1). Here we present results from two additional grains, one in situ, and one prepared as a physical separate.

Stroud, Rhonda M.↗