Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEDIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Liquid flow and distribution in unsaturated porous media

Flow and transport in permeable or porous media and microchannels occurs in a variety of situations in micro- and reduced-gravity environments, many of them associated with environmental control and life support systems. While the role of gravity is limited, due to the typically small size scales associated permeable media, gravity, at the very least, affects the overall disposition of fluid in a macroscopic system. This presentation will discuss examples where the absence of gravity affects flow and phase distribution in selected examples of unsaturated flow and transport of heat and mass in porous media and microchannels that are pertinent to spacecraft systems.

Alexander, J. Iwan↗

An Initial Non-Equilibrium Porous-Media Model for CFD Simulation of Stirling Regenerators

The objective of this paper is to define empirical parameters for an initial thermal non-equilibrium porous-media model for use in Computational Fluid Dynamics (CFD) codes for simulation of Stirling regenerators. The two codes currently used at Glenn Research Center for Stirling modeling are Fluent and CFD-ACE. The codes porous-media models are equilibrium models, which assume solid matrix and fluid are in thermal equilibrium. This is believed to be a poor assumption for Stirling regenerators; Stirling 1-D regenerator models, used in Stirling design, use non-equilibrium regenerator models and suggest regenerator matrix and gas average temperatures can differ by several degrees at a given axial location and time during the cycle. Experimentally based information was used to define: hydrodynamic dispersion, permeability, inertial coefficient, fluid effective thermal conductivity, and fluid-solid heat transfer coefficient. Solid effective thermal conductivity was also estimated. Determination of model parameters was based on planned use in a CFD model of Infinia's Stirling Technology Demonstration Converter (TDC), which uses a random-fiber regenerator matrix. Emphasis is on use of available data to define empirical parameters needed in a thermal non-equilibrium porous media model for Stirling regenerator simulation. Such a model has not yet been implemented by the authors or their associates.

Tew, Roy C.↗

Multiphase Transport in Porous Media: Gas-Liquid Separation Using Capillary Pressure Gradients International Space Station (ISS) Flight Experiment Development

Advances in the understanding of multiphase flow characteristics under variable gravity conditions will ultimately lead to improved and as of yet unknown process designs for advanced space missions. Such novel processes will be of paramount importance to the success of future manned space exploration as we venture into our solar system and beyond. In addition, because of the ubiquitous nature and vital importance of biological and environmental processes involving airwater mixtures, knowledge gained about fundamental interactions and the governing properties of these mixtures will clearly benefit the quality of life here on our home planet. The techniques addressed in the current research involving multiphase transport in porous media and gas-liquid phase separation using capillary pressure gradients are also a logical candidate for a future International Space Station (ISS) flight experiment. Importantly, the novel and potentially very accurate Lattice-Boltzmann (LB) modeling of multiphase transport in porous media developed in this work offers significantly improved predictions of real world fluid physics phenomena, thereby promoting advanced process designs for both space and terrestrial applications.This 3-year research effort has culminated in the design and testing of a zero-g demonstration prototype. Both the hydrophilic (glass) and hydrophobic (Teflon) media Capillary Pressure Gradient (CPG) cartridges prepared during the second years work were evaluated. Results obtained from ground testing at 1-g were compared to those obtained at reduced gravities spanning Martian (13-g), Lunar (16-g) and zero-g. These comparisons clearly demonstrate the relative strength of the CPG phenomena and the efficacy of its application to meet NASAs unique gas-liquid separation (GLS) requirements in non-terrestrial environments.LB modeling software, developed concurrently with the zero-g test effort, was shown to accurately reproduce observed CPG driven gas-liquid separation phenomena. The design and fabrication of a micropost plate-lamina Hele-Shaw (HS) cell was performed which served as a computationally attainable geometric structure facilitating direct comparison between physical phenomena observed in our laboratory and the LB software predictions.

Wheeler, Richard R., Jr.↗

Regeneratively Cooled Porous Media Jacket

The fluid and heat transfer theory for regenerative cooling of a rocket combustion chamber with a porous media coolant jacket is presented. This model is used to design a regeneratively cooled rocket or other high temperature engine cooling jacket. Cooling jackets comprising impermeable inner and outer walls, and porous media channels are disclosed. Also disclosed are porous media coolant jackets with additional structures designed to transfer heat directly from the inner wall to the outer wall, and structures designed to direct movement of the coolant fluid from the inner wall to the outer wall. Methods of making such jackets are also disclosed.

Mungas, Greg↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to its unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade State-of-the-Art filtration media currently used in space vehicles with water-recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early life-support-systems investigation pioneers in graphene-research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and log reduction are probed. This preliminary investigation informs on the practicability of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to its unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade State-of-the-Art filtration media currently used in space vehicles with water-recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early life-support-systems investigation pioneers in graphene-research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and log reduction are probed. This preliminary investigation informs on the practicability of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Composite media for ion processing

Composite media, systems, and devices for substantially removing, or otherwise processing, one or more constituents of a fluid stream. The composite media comprise a plurality of beads, each having a matrix substantially comprising polyacrylonitrile (PAN) and supporting one or more active components which are effective in removing, by various mechanisms, one or more constituents from a fluid stream. Due to the porosity and large surface area of the beads, a high level of contact is achieved between composite media of the present invention and the fluid stream being processed. Further, the homogeneity of the beads facilitates use of the beads in high volume applications where it is desired to effectively process a large volume of flow per unit of time.

36 MATERIALS SCIENCE↗

Laser based analysis using a passively Q-switched laser employing analysis electronics and a means for detecting atomic optical emission of the laser media

A device for Laser based Analysis using a Passively Q-Switched Laser comprising an optical pumping source optically connected to a laser media. The laser media and a Q-switch are positioned between and optically connected to a high reflectivity mirror (HR) and an output coupler (OC) along an optical axis. The output coupler (OC) is optically connected to the output lens along the optical axis. A means for detecting atomic optical emission comprises a filter and a light detector. The optical filter is optically connected to the laser media and the optical detector. A control system is connected to the optical detector and the analysis electronics. The analysis electronics are optically connected to the output lens. The detection of the large scale laser output production triggers the control system to initiate the precise timing and data collection from the detector and analysis.

47 OTHER INSTRUMENTATION↗

Proceedings for Lunch and Learn: Making science fun and exciting through social media

Social media channels are vital for outreach and offer huge opportunities for scientists to directly engage with the public using nontraditional methods – including lots of creativity and humor. The physics community’s presence is growing more significant, and this session (designed for early career researchers) provided a lively discussion with experts in the domain. We covered how to best use social media to raise public awareness of science, share excitement and progress, and cultivate support from followers. We also discussed some of the thornier issues in social media, such as capturing the complexity of both the scientific process and the science itself.

Biron, Lauren↗

Multi-organ media compositions and methods of their use

Disclosed herein are media for culture of cells, tissues, and/or organs. The media formulations disclosed herein can be used to support growth, viability, and/or function of one or more than one cell type, tissue, or organ. In some embodiments, one or more cell types, tissues, organ devices, and/or organs are contacted with a disclosed culture medium under conditions sufficient to support growth, viability, and/or function of the cell types, tissues, and/or organs. The disclosed media can be used in methods of culturing multiple cell types, and in some examples, is used in a platform device including one or more organ devices, for example, by circulating the medium through the one or more organ devices in the platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for laser system having non-planar thin disc gain media

The present disclosure relates to a laser system. The laser system may have at least non-flat gain media disc. At least one pump source may be configured to generate a beam that pumps the non-flat gain media disc. A laser cavity may be formed by the pump source and the non-flat gain media disc. An output coupler may be included for receiving and directing the output beam toward an external component.

Dawson, Jay W.↗

Spent enrichment media for growth of gene-matched microorganisms

A method for amplifying and detecting microorganisms, such as species of Listeria, is described. The method utilizes gene-matched enrichment media and PCR-based detection. The enrichment media is spent media produced using a modified microorganism containing a plurality of mutations in a selected gene such that the modified microorganism does not contain the PCR signature. Thus, PCR detects only the amplified microorganism of interest, not the modified microorganism. Exemplary methods and kits for amplification and detection of Listeria species are described.

Ozanich, Richard M.↗

CFD study of natural convection mixing in a steam generator mock-up: Comparison between full geometry and porous media approaches

In CFD simulations of flow mixing in a steam generator (SG) during natural circulation, one is faced with the problem of representing the thousands of SG U-tubes. Typically simplifications are made to render the problem computationally tractable. In particular, one or a number of tubes are lumped in one volume which is treated as a single porous medium. This approach dramatically reduces the computational size of the problem and hence simulation time. In this work, we endeavor to investigate the adequacy of this approach by performing two separate simulations of flow in a mock-up with 262 U-tubes, i.e. one in which the porous media model is used for the tube bundle, and another in which the full geometry is represented. In both simulations, the Reynolds Stress (RMS) model of turbulence is used. We show that in steady state conditions, the porous media treatment yields results which are comparable to those of the full geometry representation (temperature distribution, recirculation ratio, hot plume spread, etc). Hence, the porous media approach can be extended with a good degree of confidence to the full scale SG. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fukushima Media Involvement: Lessons Learned and Challenges - 13261

Only days after the Fukushima nuclear reactor disaster on March 11, 2011, the DOE's Pacific Northwest National Laboratory, or PNNL, found itself in a maelstrom of media attention following its announcement of the detection of minute levels of radioactive material originating from the damaged reactors 4,500 miles away. Because PNNL develops state-of-the-art ultra-sensitive radionuclide detection and monitoring systems for national security applications, and has some of the equipment operating on its Richland campus, there was little surprise when one of these sophisticated systems led PNNL to be the first to detect measurable radionuclides in the United States. On Wednesday, March 16, 2011, that system detected minuscule levels of short-lived radioactive xenon, a telltale element derived from either weapons testing or a major reactor disruption. Immediately after the detection was announced, a flurry of inquiries nearly overwhelmed staff as governments, scientific organizations, the general public, and reporters struggled to understand and estimate what impacts this disaster might have on health and environment. Over the course of about three weeks, PNNL's News and Media Relations staff and its scientists and engineers responded to more than 100 requests for information, and engaged in dozens of personal interviews with international, national, regional, and local media. While many of the interviews and resulting stories were accurate and well done, not all communication went flawlessly. In the midst of chaos and confusion, which are part of any significant crisis, hiccoughs are sure to occur. Addressed here is 'the rest of the story'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Stability of SiO{sub 2} Fe{sub 3}O{sub 4} Nanoparticles for Uranium Extraction in Acidic Media - 20189

This comprehensive study has shown that the proposed strategy of SiO{sub 2} coating of Fe{sub 3}O{sub 4} nanoparticles (NPs) for the use of uranium (U) extraction in acidic media was successful. The breakdown of Fe{sub 3}O{sub 4} in acidic media has proven to be a challenge when applying to a nuclear waste removal scenario, leading to the dissolution of Fe{sub 3}O{sub 4} and preventing uptake of U ions in the waste. To overcome this a SiO{sub 2} passivating layer was grafted to the Fe{sub 3}O{sub 4} NPs, to which an acid stability test was conducted between pH 3 and pH 4. It has been shown via Transmission Electron Microscopy (TEM) and zeta potential measurements that the uncoated Fe{sub 3}O{sub 4} NPs exhibit rapid coagulation when exposed to acidic conditions, moving from a stable zeta potential of -44 mV to an unstable zeta potential of +6 mV. SiO{sub 2} coated Fe{sub 3}O{sub 4} on the other hand can remain stable for several hours and continue to be stable beyond that. Throughout acid exposure the zeta potential of these NPs remained at ∼ -38 mV, showing great stability. As a functionality is needed on the surface of the NPs for separation and extraction, the phosphate complex used was also tested for its acid stability. It was determined that with a constant zeta potential of ∼ -20 mV, the phosphate functionality was able to remain stable in the acidic conditions simulating the environment of certain nuclear wastes. Overall SiO{sub 2} coated (PO)x-Fe{sub 3}O{sub 4} NPs show great promise for application in separation and removal of U in acid media. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimum critical values for various fissile media with very low content of plutonium mixed in different kinds of matrix - 14340

For materials slightly contaminated by fissile nuclides (such as radioactive sludge), it could be useful to take into account the low fissile density in order to define the nuclear criticality safety limits (mass, volume,...) when this density is lower than the one of the optimally moderated fissile-water mixture (e.g. 30 g/dm{sup 3} for {sup 239}Pu). In such a case, if the material is modelled by the usual fissile-water mixture only, the fissile medium still contains a void fraction when the optimal moderation ratio is reached. Then, the question is to know whether modeling the other elements of the material can impact the nuclear criticality safety limits, in particular when they are good scattering elements. This paper aims at studying the impact of replacing the void fraction in plutonium fissile media, with various apparent densities, by different kinds of matrix containing scattering elements. Minimum critical values (mass, volume, diameter and thickness) have been determined for plutonium media, composed of 100 % {sup 239}Pu, with densities of 2, 5.8 and 7.3 g/dm{sup 3} in different kinds of matrix containing scattering elements (graphite, carbon, alumina, silica, magnesia, fluorite and calcium oxide). Different contents of the aforementioned scattering elements in the fissile media were studied and additional moderation was ensured by water. The results highlight that minimum critical values are lower when considering a fissile medium containing graphite, carbon, silica, alumina and magnesia with additional water moderation, compared to plutonium-water mixture only with the same low fissile apparent density. However, there is still a benefit of crediting density (critical values for a low fissile density are still higher than critical values without a density control). (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗