Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lead.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Exposure to lead in South African shooting ranges

Introduction: Lead exposure in shooting ranges has been under scrutiny for decades, but no information in this regard is available in respect of African settings, and in South Africa specifically. The aim of this study was to determine the blood lead levels in the users of randomly selected private shooting ranges in South Africa's Gauteng province. Methods: An analytical cross sectional study was conducted, with participants recruited from four randomly selected shooting ranges and three archery ranges as a comparator group. Results: A total of 118 (87 shooters and 31 archers) were included in the analysis. Shooters had significantly higher blood lead levels (BLL) compared to archers with 36/85 (42.4%) of shooters versus 2/34 (5.9%) of archers found to have a BLL ≥10 μg/dl (p<0.001). Conclusion: Shooting ranges may constitute an import site of elevated exposure to lead. Improved ventilation, low levels of awareness of lead hazards, poor housekeeping, and inadequate personal hygiene facilities and practices at South African shooting ranges need urgent attention. - Highlights: • This is the first study, to our knowledge, of lead exposure in shooting ranges in an African setting. • This study indicates highly elevated lead exposure amongst the users of certain private shooting ranges in South Africa. • Lead exposure may be a serious, yet under-studied, source of adult lead exposure in South Africa, and possibly elsewhere on the African continent.

54 ENVIRONMENTAL SCIENCES↗

The relationship between occupational exposure to lead and manifestation of cardiovascular complications in persons with arterial hypertension

The chronic exposure to lead represents a risk factor of arterial hypertension development. Ambulatory blood pressure monitoring is the most prognostically reliable method of measuring of arterial blood pressure. The study is aimed at evaluating the relationship between occupational exposure to lead and manifestation of cardiovascular complications in patients with arterial hypertension. The studies included 73 men (mean age, 54.26 {+-} 8.17 years) with arterial hypertension, treated with hypotensive drugs: group I-persons occupationally exposed to lead (n = 35) and group II-individuals not exposed to lead (n = 38). An analysis of results obtained during ambulatory blood pressure monitoring disclosed significantly higher values of mean systolic blood pressure, mean blood pressure, pulse pressure, and variability of systolic blood pressure in the group of hypertensive patients occupationally exposed to lead as compared to patients with arterial hypertension but not exposed to lead. The logistic regression showed that a more advanced age, higher concentration of blood zinc protoporphyrin, and a higher mean value of pulse pressure represented independent risk factors of left ventricular hypertrophy in the group of persons with arterial hypertension and chronically exposed to lead (OR{sub age} = 1.11; OR{sub ZnPP} = 1.32; OR{sub PP} = 1,43; p < 0.05). In view of the above data demonstration that occupational exposure to lead represents an independent risk factor of increased pulse pressure may be of key importance in the process of shaping general social awareness as to harmful effects of lead compounds on human health.

60 APPLIED LIFE SCIENCES↗

Blood lead level association with lower body weight in NHANES 1999–2006

Background: Lead exposure is associated with low birth-weight. The objective of this study is to determine whether lead exposure is associated with lower body weight in children, adolescents and adults. Methods: We analyzed data from NHANES 1999–2006 for participants aged ≥ 3 using multiple logistic and multivariate linear regression. Using age- and sex-standardized BMI Z-scores, overweight and obese children (ages 3–19) were classified by BMI ≥ 85th and ≥ 95th percentiles, respectively. The adult population (age ≥ 20) was classified as overweight and obese with BMI measures of 25–29.9 and ≥ 30, respectively. Blood lead level (BLL) was categorized by weighted quartiles. Results: Multivariate linear regressions revealed a lower BMI Z-score in children and adolescents when the highest lead quartile was compared to the lowest lead quartile (β (SE) = − 0.33 (0.07), p < 0.001), and a decreased BMI in adults (β (SE) = − 2.58 (0.25), p < 0.001). Multiple logistic analyses in children and adolescents found a negative association between BLL and the percentage of obese and overweight with BLL in the highest quartile compared to the lowest quartile (OR = 0.42, 95% CI: 0.30–0.59; and OR = 0.67, 95% CI: 0.52–0.88, respectively). Adults in the highest lead quartile were less likely to be obese (OR = 0.42, 95% CI: 0.35–0.50) compared to those in the lowest lead quartile. Further analyses with blood lead as restricted cubic splines, confirmed the dose-relationship between blood lead and body weight outcomes. Conclusions: BLLs are associated with lower body mass index and obesity in children, adolescents and adults. - Highlights: • NHANES analysis of BLL and body weight outcomes • Increased BLL associated with decreased body weight in children and adolescent • Increased BLL associated with decreased body weight in adults.

60 APPLIED LIFE SCIENCES↗

Lead Service Line Inventory at the Materials and Fuels Complex

In 1986, Congress amended the Safe Drinking Water Act prohibiting the use of lead in pipes for providing water. This was due to research on lead poisoning showing lead was extremely detrimental to the development of kids and cognitive abilities in adults. Now, because of the amendment of 1986, the EPA 2021 Lead and Copper Rule Revision came out since then to promote progress in the inventory and elimination of lead pipes. The Idaho Department of Environmental Quality(IDEQ) adopted this rule for the state which means every water system in Idaho fall under the new regulation. By October 16, 2024, the INL must report to the IDEQ, the pipe materials in a Lead Service Line Inventory(LSLI) in hopes of finding lead. If lead is found, a Lead Service Line Replacement Plan is required. This poster only specifically talks about the results for the largest site out on the desert, Materials and Fuels Complex(MFC), as the INL also consists of ATR, INTEC, SMC, and CFA.

54 ENVIRONMENTAL SCIENCES↗

Hybrid structures formed by homo- and heteroleptic aliphatic dicarboxylates of lead with 2-D inorganic connectivity

Three-dimensional homoleptic (single type of ligand) lead dicarboxylates with hybrid structures involving Pb-O-Pb linkages of the compositions, Pb(C{sub 5}H{sub 6}O{sub 4}), I, and Pb(C{sub 6}H{sub 8}O{sub 4}), II and III, have been synthesized and characterized. Three-dimensional heteroleptic (mixed ligands) lead dicarboxylates of the formulae, Pb{sub 2}(C{sub 2}O{sub 4})(C{sub 4}H{sub 4}O{sub 4}), IV and Pb{sub 2}(C{sub 2}O{sub 4})(C{sub 6}H{sub 8}O{sub 4}), V, with hybrid structures involving Pb-O-Pb linkages have also been prepared and characterized along with a novel two-dimensional lead nitrate-oxalate of the composition, (OPb{sub 2}){sub 2}(C{sub 2}O{sub 4})(NO{sub 3}){sub 2}, VI. In all these dicarboxylates, there is two-dimensional inorganic connectivity and the lead (II) cation has hemi- or holo-directed coordination geometry. Depending upon the torsional angle and the coordination mode of the dicarboxylate anions as well as the geometry of the lead (II) cations, these hybrid compounds exhibit two types of two-dimensional inorganic connectivities. - Graphical abstract: Three homoleptic and two heteroleptic three-dimensional lead aliphatic dicarboxylates along with a novel two-dimensional lead nitrate-oxalate with hybrid structures involving Pb-O-Pb linkages have been synthesized and charecterized. In all these dicarboxylates, there is two-dimensional inorganic connectivity. The lead (II) cation has hemi- or holo-directed coordination geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A RELAP5-3D Model of the Lobo Lead Loop

The goal of our research is to build upon the capability of RELAP5-3D to model molten lead systems. Molten lead has several potential uses in future advanced reactors like the lead fast reactor or fusion reactors that utilize dual-coolant lead lithium blankets. This potential for use in future generations of reactors highlights the necessity to develop molten lead models to ensure that they can accurately predict the thermohydraulic behavior. We have developed a RELAP5-3D model of the Lobo Lead Loop facility, located at the University of New Mexico, to verify the accuracy of RELAP5-3D via comparison to existing computational fluid dynamics results and analytical calculations. It was found that RELAP5-3D accurately calculated radiative heat transfer (within < 1%) when compared to theoretical calculations. In addition, pressure drop calculations done in RELAP5-3D demonstrated reasonable agreement within 20 kPa, mostly within ~7-15%, when compared to the computational fluid dynamics model of the facility developed by the University of New Mexico, and captured the dependence of pressure drop on flow velocity accurately. Finally, a hypothetical loss of flow transient was imposed on the RELAP5-3D model to determine the feasibility of performing a similar experiment with the Lobo Lead Loop. It was found that such an experiment could be possible as the RELAP5-3D model indicated that the temperatures of the fluid would not exceed limiting temperatures of the structure (1658 K) nor the maximum temperature of the electromagnetic pump inlet (823 K). Although there is not experimental data to begin validation, the model will be readily available for future validation studies when the experimental data is generated, especially as the model continues to evolve over time. Furthermore, the results so far demonstrate a promising first step in the verification/validation of the RELAP5-3D model of the Lobo Lead Loop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Telomere length in children environmentally exposed to low-to-moderate levels of lead

Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r{sub S} = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R{sup 2}adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R{sup 2}adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r{sub S} = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R{sup 2}adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between environmental lead exposure and telomere length in children. • Blood lead concentrations were inversely associated with relative telomere length in 8-year-old children. • Environmental lead exposure during childhood might contribute to telomere shortening, and in turn, future risk for disease.

60 APPLIED LIFE SCIENCES↗

SU-E-P-20: Personnel Lead Apparel Integrity Inspection: Where We Are and What We Need?

Purpose: In recent years, tremendous efforts have been devoted to radiation dose reduction, especially for patients who are directly exposed to primary radiation or receive radiopharmaceuticals. Limited efforts have been focused on those personnel who are exposed to secondary radiation while fulfilling their work responsibilities associated with diagnostic imaging and image-guided interventions. Occupational exposure is compounded in daily practice and can lead to a significant radiation dose over time. Personnel lead apparel is a well-accepted engineering control to protect healthcare workers when radiation is inevitable. The question is, do we have a nationally established program to protect personnel? This study is to investigate the lead apparel inspection programs among the USA. Methods: A series of surveys of state regulations, the University Health System Consortium, and federal regulations and regulations determined by accrediting bodies were conducted. The surveys were used to determine the current status of lead apparel programs regarding integrity inspections. Based on the survey results, a thorough program was proposed accordingly. Results: Of 50 states, seventeen states and Washington D.C. require lead apparel integrity inspections within their state regulations. Eleven of these states specify that the inspection is required on an annual basis. Two of these states require lead apron integrity checks to be performed semi-annually. Eleven out of the two hundred academic medical centers surveyed responded. The results show that the method (visually vs. fluoroscopy) used to conduct lead apparel integrity checks differ greatly amongst healthcare organizations. The FDA, EPA, CRCPD and NCRP require lead apparel integrity checks. However, the level of policies is different. A standard program is not well established and clearly there is a lack of standardization. Conclusion: A program led by legislative (state or federal government) and with specific frequency, methods, tracking and criteria is needed to ensure the integrity of personnel lead apparel.

60 APPLIED LIFE SCIENCES↗

What Caused the Lead burn-out in Spectrometer Magnet 2B

The spectrometer solenoids are supposed to be the first magnets installed in the MICE Cooling Channel. The results of the test of Spectrometer Magnet 2B are reported in a previous MICE Note. Magnet 2B was tested with all five coils connected in series. The magnet failed because a lead to coil M2 failed before it could be trained to its full design current of 275 A. First, this report describes the condition of the magnet when the lead failure occurred. The lead that failed was between the cold mass feed-through and the heavy lead that connected to coil M2 and the quench protection diodes. It is believed that the lead failed because the minimum propagation zone (MPZ) length was too short. The quench was probably triggered by lead motion in the field external to the magnet center coil. The effect of heat transfer on quench propagation and MPZ length is discussed. The MPZ length is compared for a number of cases that apply to the spectrometer solenoid 2B as built and as it has been repaired. The required heat transfer coefficient for cryogenic stability and the quench propagation velocity along the leads are compared for various parts of the Magnet leads inside the cold mass cryostat. The effect of the insulation on leads on heat transfer is and stability is discussed.

42 ENGINEERING↗

Importance of Pipe Deposits to Lead and Copper Rule Compliance

When Madison, Wis., exceeded the lead action level in 1992, residential and off-line tests suggested that lead release into the water was more complex than a lead solubility mechanism. Scale analyses (color and texture as well as mineralogical and elemental composition) of five excavated lead service lines (LSLs) revealed that accumulation of manganese (and iron) onto pipe walls had implications for lead corrosion by providing a high-capacity sink for lead. Manganese that accumulated from source well water onto pipe scales (up to 10% by weight of scale composition) served to capture and eventually transport lead to consumer taps. In addition, manganese sometimes obstructed the predominance of an insoluble (and thus potentially protective) plattnerite [Pb(IV) solid] scale layer. Full LSL replacement in Madison achieved Lead and Copper Rule compliance and a major reduction in lead contamination and exposure, supplemented by unidirectional flushing of water mains and manganese control in the source well water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of leading-edge devices on the low-speed aerodynamic characteristics of a highly-swept arrow-wing

An investigation was conducted in the Texas A&M University 7 by 10 foot Low Speed Wind Tunnel to provide a direct comparison of the effect of several leading edge devices on the aerodynamic performance of a highly swept wing configuration. Analysis of the data indicates that for the configuration with undeflected leading edges, vortex separation first occurs on the outboard wing panel for angles of attack of approximately 2, and wing apex vorticies become apparent for alpha or = 4 deg. However, the occurrence of the leading edge vortex flow may be postponed with leading edge devices. Of the devices considered, the most promising were a simple leading edge deflection of 30 deg and a leading edge slat system. The trailing edge flap effectiveness was found to be essentially the same for the configuration employing either of these more promising leading edge devices. Analysis of the lateral directional data showed that for all of the concepts considered, deflecting leading edge downward in an attempt to postpone leading edge vortex flows, has the favorable effect of reducing the effective dihedral.

Scott, S. J.↗

Increased heat transfer to elliptical leading edges due to spanwise variations in the freestream momentum: Numerical and experimental results

A study of the effect of spanwise variation in momentum on leading edge heat transfer is discussed. Numerical and experimental results are presented for both a circular leading edge and a 3:1 elliptical leading edge. Reynolds numbers in the range of 10,000 to 240,000 based on leading edge diameter are investigated. The surface of the body is held at a constant uniform temperature. Numerical and experimental results with and without spanwise variations are presented. Direct comparison of the two-dimensional results, that is, with no spanwise variations, to the analytical results of Frossling is very good. The numerical calculation, which uses the PARC3D code, solves the three-dimensional Navier-Stokes equations, assuming steady laminar flow on the leading edge region. Experimentally, increases in the spanwise-averaged heat transfer coefficient as high as 50 percent above the two-dimensional value were observed. Numerically, the heat transfer coefficient was seen to increase by as much as 25 percent. In general, under the same flow conditions, the circular leading edge produced a higher heat transfer rate than the elliptical leading edge. As a percentage of the respective two-dimensional values, the circular and elliptical leading edges showed similar sensitivity to span wise variations in momentum. By equating the root mean square of the amplitude of the spanwise variation in momentum to the turbulence intensity, a qualitative comparison between the present work and turbulent results was possible. It is shown that increases in leading edge heat transfer due to spanwise variations in freestream momentum are comparable to those due to freestream turbulence.

Rigby, D. L.↗

Development of X-43A Mach 10 Leading Edges

The nose leading edge of the Hyper-X Mach 10 vehicle was orginally anticipated to reach temperatures near 4000 F at the leading-edge stagnation line. A SiC coated carbon/carbon (C/C) leading-edge material will not survive that extreme temperature for even a short duration single flight. To identify a suitable leading edge for the Mach 10 vehicle, arc-jet testing was performed on thirteen leading-edge segments fabricated from different material systems to evaluate their performance in a simulated flight environment. Hf, Zr, Si, and Ir based materials, in most cases as a coating on C/C, were included in the evaluation. Afterwards, MER, Tucson, AZ was selected as the supplier of the flight vehicle leading edges. The nose and the vertical and horizontal tail leading edges were fabricated out of a 3:1 biased high thermal conductivity C/C. The leading edges were coated with a three layer coating comprised of a SiC conversion of the top surface of the C/C, followed by a chemical vapor deposited layer of SiC, followed by a thin chemical vapor deposited layer of HfC. This paper will describe the fabrication of the Mach 10 C/C leading edges and the testing performed to validate performance.

Ohlhorst, Craig W.↗

Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead high-fidelity ECG employing and combining the results of several advanced ECG software techniques shows great promise as a rapid and inexpensive tool for screening of heart disease.

Schlegel, T. T.↗

Concentrations and Origins of Atmospheric Lead and Other Trace Species at a Rural Site in Northern China

In this study we analyze the ambient levels of lead and other trace species in the bulk aerosol samples from a rural site approx.70 km ESE of Beijing in spring 2005. Lead (0.28+/-0.24 micro-g/cu m, average +/- standard deviation), along with several pollution \related trace elements, was enriched by over 100 fold relative to the Earth's crust. The ambient lead levels showing large synoptic variations were well-correlated with other anthropogenic pollutants (e.g., CO and SO2). The Unmix receptor model resolved four factors in the aerosol composition data: a biomass burning source, an industrial and coal combustion source, a secondary aerosol source, and a dust source. The first three sources were strongest in weak southerly winds ahead of cold fronts, while the dust source peaked in strong northerly winds behind cold fronts. The second source, primarily representing emissions from industrial processes and relatively small \scale coal burning such as in home and institutional heating, was identified as the main source of ambient lead in this study. Mobile sources might also contribute to this factor, but there was no distinct evidence of emissions due to combustion of leaded gasoline, despite a correlation between lead and CO. Potential source contribution function, calculated from backward trajectories and aerosol composition, further reveals that lead observed in this study was predominantly from the populated and industrialized areas to the south and SW of Xianghe, rather than Beijing to the west. Our results and several recent studies show that the lead levels in suburban areas near big cities in China, although generally lower than those in industrial districts and urban areas, are substantial (near or above 0.15 micro-g/cu m). More extensive studies on airborne lead and its emission sources in China are called for.

Li, Can↗

Development of Advanced High Lift Leading Edge Technology for Laminar Flow Wings

This paper describes the Advanced High Lift Leading Edge (AHLLE) task performed by Northrop Grumman Systems Corporation, Aerospace Systems (NGAS) for the NASA Subsonic Fixed Wing project in an effort to develop enabling high-lift technology for laminar flow wings. Based on a known laminar cruise airfoil that incorporated an NGAS-developed integrated slot design, this effort involved using Computational Fluid Dynamics (CFD) analysis and quality function deployment (QFD) analysis on several leading edge concepts, and subsequently down-selected to two blown leading-edge concepts for testing. A 7-foot-span AHLLE airfoil model was designed and fabricated at NGAS and then tested at the NGAS 7 x 10 Low Speed Wind Tunnel in Hawthorne, CA. The model configurations tested included: baseline, deflected trailing edge, blown deflected trailing edge, blown leading edge, morphed leading edge, and blown/morphed leading edge. A successful demonstration of high lift leading edge technology was achieved, and the target goals for improved lift were exceeded by 30% with a maximum section lift coefficient (Cl) of 5.2. Maximum incremental section lift coefficients ( Cl) of 3.5 and 3.1 were achieved for a blown drooped (morphed) leading edge concept and a non-drooped leading edge blowing concept, respectively. The most effective AHLLE design yielded an estimated 94% lift improvement over the conventional high lift Krueger flap configurations while providing laminar flow capability on the cruise configuration.

Bright, Michelle M.↗

RHIC 12x150A current lead temperature controller: design and implementation

There are 60 12 x 150A current leads distributed in six RHIC service buildings; each lead delivers power supply current from room temperature to cryogenic temperature in RHIC. Due to the humid environment, condensation occurs frequently and ice forms quickly during operation, especially during an extensive storage period. These conditions generate warnings and alarms to which personnel must respond and establish temporary solutions to keep the machine operating. In here, we designed a temperature control system to avoid such situations. This paper discusses its design, implementation, and some results. There are six service buildings in the RHIC complex; each building has two valve boxes that transfer room-temperature current cables from the power supplies into superconducting leads, and then transport them into the RHIC tunnel. In there, the transition between the room-temperature lead into superconducting lead is critical and essential; smooth running during the physics store is crucial for the machine's continuing operation. One of the problems that often occurred previously was the icing of these current leads that could result in a potential leakage current onto ground, thereby preventing a continuous supply of physics store. Fig. 1 illustrates a typical example on a power lead. Among the modifications of the design of the valve box, we list below the new requirements for designing the temperature controller to prevent icing occurring: (1) Remotely control, monitor, and record each current lead's temperature in real time. Prevent icing or overheating of a power lead. (2) Include a temperature alarm for the high/low level threshold. In this paper we discuss the design, implementation, upgrades to, and operation of this new system.

43 PARTICLE ACCELERATORS↗

Lead Coolant Test Facility - Design Concept and Requirements

The Idaho National Laboratory prepared a preliminary technical and functional requirements (T&FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic. Based on review of current world lead or lead-bismuth test facilities and research need listed in the Generation IV Roadmap, five broad areas of requirements are identified in this paper: (1) Develop and Demonstrate Feasibility of Submerged Heat Exchanger; (2) Develop and Demonstrate Open-lattice Flow in Electrically Heated Core; (3) Develop and Demonstrate Chemistry Control; (4) Demonstrate Safe Operation; and (5) Provision for Future Testing Across these five broad areas are supported by twenty-one specific requirements. The purpose of this facility is to focus the lead fast reactor community domestically on the requirements for the next unique state of the art test facility. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 4200C. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3.7M (in 2006 $). It is also estimated that the facility will require two years to be constructed and ready for operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗