Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANSCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

MARSAME Radiological Release Report for Metal Items from TA 53, Set 22

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever bein direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

36 MATERIALS SCIENCE↗

LAMP Emittance Budget Rev. 2

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP).

43 PARTICLE ACCELERATORS↗

LAMP Operational Concepts

This brief report describes the major operational changes resulting from accelerator design and implementation of the LAMP scope. Improvements in operational performance are discussed, along with implications for integration with the existing LANSCE accelerator complex. Potential impacts to the present LANSCE operational modes and integration with the existing personnel and machine protection systems are also discussed.

43 PARTICLE ACCELERATORS↗

Beamline Device Designators

LAMP is to replace the front-end of LANSCE. Therefore, the device designators for LAMP needs approval from LANSCE. This document defines the agreed upon device designator names to be used in LAMP and in the prototype beamline LAMP in ADEF Tunnel (LAT).

43 PARTICLE ACCELERATORS↗

On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.

47 OTHER INSTRUMENTATION↗

Micronuclei Induction in Human Fibroblasts Exposed In Vitro to Los Alamos High-Energy Neutrons

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility#s ICE House 30L beamline is known to generate neutrons that simulate the secondary neutron spectra of earth#s atmosphere. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and International Space Station (ISS). To evaluate the biological damage, we exposed human fibroblasts in vitro to the LANSCE neutron beams without degrader at an entrance dose rate of 25 mGy/hr and analyzed the micronuclei (MN) induction. The cells were also placed behind a 9.9 cm water column to study effect of shielding in the protection of neutron induced damages. It was found that the dose response in the MN frequency was linear for the samples with and without shielding and the slope of the MN yield behind the shielding was reduced by a factor of 3.5. Compared to the MN induction in human fibroblasts exposed to a gamma source at a low dose rate, the RBE was found to be 16.7 and 10.0 for the neutrons without and with 9.9 cm water shielding, respectively.

Gersey, Brad↗

M-BAND Analysis of Chromosome Aberration In Human Epithelial Cells exposed to Gamma-ray and Secondary Neutrons of Low Dose Rate

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.

Hada, M.↗

SRF Cavity High-Gradient Study at 805 MHz for Proton and Other Applications

805 MHz elliptical SRF cavities have been used for SNS as the first application for protons. At LANL, an R&D started to explore a capability of getting high-gradient cavities (40-50 MV/m) at this frequency for the future applications such as proton and muon based interrogation testing facility added to the LANSCE accelerator and a power upgrade of the LANSCE accelerator for the fission and fusion material test station. Optimized cell designs for “standard”, “low-loss” and “re-entrant” shapes, cavity test results for “standard” single-cell cavities with temperature mapping as well as surface inspection results will be presented.

43 PARTICLE ACCELERATORS↗

A pulse width modulated picket fence pulser to reduce accelerator start-up transients

This paper describes a solid state modulator used to control the input beam to the Los Alamos Neutron Science Center 'LANSCE' 800 MeV accelerator. This electrostatic Ground Level Deflector (GLD) chops the beam after the 750 keV injection energy. Two GLD's are utilized, one for the 'H+' beam and another for the 'H-' beam. These modulators are mounted on the vacuum beam pipe and directly operate sets of deflection plates. To minimize the accelerator beam start up transients, the beam is let into the accelerator cavity structures by a pulse width modulated picket fence operating between 0 and 12 kV. As the deflection plate structure appears as a capacitive load, a totem-pole switching network is utilized to facilitate rise and fall times of {approx}50 ns that is able to sink and source current to minimize beam induced sidewall activation. This paper will describe the system design and provides operational results as now presently utilized on the LANSCE accelerator system.

43 PARTICLE ACCELERATORS↗

Stripping of H- beams by residual gas in the linac at the Los Alamos neutron science center

The linear accelerator at the Los Alamos Neutron Science Center (LANSCE) accelerates both protons and H{sup -} ions using Cockroft-Walton-type injectors, a drift-tube linac and a coupled-cavity linac. The vacuum is maintained in the range of 10{sup -6} to 10{sup -7} Torr; the residual gas in the vacuum system results in some stripping of the electrons from the H{sup -} ions resulting in beam spill and the potential for unwanted proton beams delivered to experiments. We have measured the amount of fully-stripped H{sup -} beam (protons) that end up at approximately 800 MeV in the beam switchyard at LANSCE using image plates as very sensitive detectors. We present here the motivation for the measurement, the measurement technique and results.

43 PARTICLE ACCELERATORS↗

Experimental Physical Sciences Vistas: MaRIE (draft)

To achieve breakthrough scientific discoveries in the 21st century, a convergence and integration of world-leading experimental facilities and capabilities with theory, modeling, and simulation is necessary. In this issue of Experimental Physical Sciences Vistas, I am excited to present our plans for Los Alamos National Laboratory's future flagship experimental facility, MaRIE (Matter-Radiation Interactions in Extremes). MaRIE is a facility that will provide transformational understanding of matter in extreme conditions required to reduce or resolve key weapons performance uncertainties, develop the materials needed for advanced energy systems, and transform our ability to create materials by design. Our unique role in materials science starting with the Manhattan Project has positioned us well to develop a contemporary materials strategy pushing the frontiers of controlled functionality - the design and tailoring of a material for the unique demands of a specific application. Controlled functionality requires improvement in understanding of the structure and properties of materials in order to synthesize and process materials with unique characteristics. In the nuclear weapons program today, improving data and models to increase confidence in the stockpile can take years from concept to new knowledge. Our goal with MaRIE is to accelerate this process by enhancing predictive capability - the ability to compute a priori the observables of an experiment or test and pertinent confidence intervals using verified and validated simulation tools. It is a science-based approach that includes the use of advanced experimental tools, theoretical models, and multi-physics codes, simultaneously dealing with multiple aspects of physical operation of a system that are needed to develop an increasingly mature predictive capability. This same approach is needed to accelerate improvements to other systems such as nuclear reactors. MaRIE will be valuable to many national security science challenges. Our first issue of Vistas focused on our current national user facilities (the Los Alamos Neutron Science Center [LANSCE], the National High Magnetic Field Laboratory-Pulsed Field Facility, and the Center for Integrated Nanotechnologies) and the vitality they bring to our Laboratory. These facilities are a magnet for students, postdoctoral researchers, and staff members from all over the world. This, in turn, allows us to continue to develop and maintain our strong staff across the relevant disciplines and conduct world-class discovery science. The second issue of Vistas was devoted entirely to the Laboratory's materials strategy - one of the three strategic science thrusts for the Laboratory. This strategy has helped focus our thinking for MaRIE. We believe there is a bright future in cutting-edge experimental materials research, and that a 21st-century facility with unique capability is necessary to fulfill this goal. The Laboratory has spent the last several years defining MaRIE, and this issue of Vistas presents our current vision of that facility. MaRIE will leverage LANSCE and our other user facilities, as well as our internal and external materials community for decades to come, giving Los Alamos a unique competitive advantage, advancing materials science for the Laboratory's missions and attracting and recruiting scientists of international stature. MaRIE will give the international materials research community a suite of tools capable of meeting a broad range of outstanding grand challenges.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Wide-Bandwidth Capture of Wire-Scanner Signals

Integrated charge collected on the sense wires of wire-scanner systems utilized to determine beam profile is generally the parameter of interest. The LANSCE application requires capturing the charge information macropulse-by-macropulse with macropulse lengths as long as 700 {micro}s at a maximum macropulse rate of 120 Hz. Also, for the LANSCE application, it is required that the integration be performed in a manner that does not require integrator reset between macropulses. Due to the long macropulse which must be accommodated and the 8.33 ms minimum pulse period, a simple R-C integrator cannot be utilized since there is insufficient time between macropulses to allow the integrator to adequately recover. The application of wide analog bandwidth to provide accurate pulse-by-pulse capture of the wire signals with digital integration of the wire signals to determine captured charge at each macropulse in applications with comparatively long macropulses and high pulse repetition rates is presented.

43 PARTICLE ACCELERATORS↗

Incremental performance improvements for a surface-convergency H- ion source

We discuss some of the interventions on LANSCE's surface-conversion negative-hydrogen ion sources to increase reliability; lifetime and output without any major re-design of the machine. LANSCE's source presently delivers a baseline 16 mA, 60 Hz, 12% duty factor beam. We describe how better quality control and processing of tungsten filaments allow the comfortable completion of 28-day run cycles, how improved temperature control of the ion source body yields an increased H{sup -} output, how higher input power through an additional filament allows operations at plasma densities while maintaining the filament lifetime and how adequate electrode biasing inside the source provide some control over the beam Twiss parameters on exit.

43 PARTICLE ACCELERATORS↗

Inelastic cross sections from gamma-ray measurements

Measurements of gamma rays following neutron induced reactions have been studied with the Germanium Array for Neutron-induced Excitations (GEANIE) at the Los Alamos Neutron Science Center (LANSCE) for many years. Gamma-ray excitation functions and coincidence studies provide insight into nuclear reaction mechanisms as well as expanding our knowledge of energy levels and gamma-rays. Samples studied with Ge detectors at LANSCE range from Be to Pu. Fe, Cr and Ti have been considered for use as reference cross sections. An overview of the measurements and efforts to create a reliable neutron-induced gamma-ray reference cross section will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First results with a surface conversion H ion source based on helicon wave mode-driven plasma discharge

The currently employed converter-type negative ion source at Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. The extracted H{sup -} beam current is limited by the achievable plasma density, which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which degrades the performance of the H{sup -} conversion surface. In order to overcome these limitations we have designed and tested a prototype of a surface conversion H{sup -} ion source, based on excitation of helicon plasma wave mode with an external antenna. The source has been operated with and without cesium injection. An H{sup -} beam current of over 12 mA has been transported through the low energy beam transport of the LANSCE ion source test stand. The results of these experiments and the effects of different source parameters on the extracted beam current are presented. The limitations of the source prototype are discussed and future improvements are proposed based on the experimental observations.

43 PARTICLE ACCELERATORS↗

Operational status and future plans for Los Alamos Neutron Science Center

The Los Alamos Neutron Science Center (LANSCE) continues to be a signature experimental science facility at Los Alamos National Laboratory (LANL). The 800 MeV linear proton accelerator provides multiplexed beams to five unique target stations to produce medical radioisotopes, ultra-cold neutrons, thermal and high energy neutrons for material and nuclear science, and to conduct proton radiography of dynamic events. Recent operating experience will be reviewed and the role of an enhanced LANSCE facility in LANL's new signature facility initiative, Matter and Radiation in Extremes (MaRIE) will be discussed.

43 PARTICLE ACCELERATORS↗

Neutron proton crystallography station (PCS)

The PCS (Protein Crystallography Station) at Los Alamos Neutron Science Center (LANSCE) is a unique facility in the USA that is designed and optimized for detecting and collecting neutron diffraction data from macromolecular crystals. PCS utilizes the 20 Hz spallation neutron source at LANSCE to enable time-of-flight measurements using 0.6-7.0 {angstrom} neutrons. This increases the neutron flux on the sample by using a wavelength range that is optimal for studying macromolecular crystal structures. The diagram below show a schematic of PCS and photos of the detector and instrument cave.

59 BASIC BIOLOGICAL SCIENCES↗