Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An Investigation into the Electromagnetic Interactions between a Superconducting Torus and Solenoid for the Jefferson Lab 12 GeV Upgrade

The Jefferson Lab 12 GeV Upgrade in Hall B will need CLAS12 detector that requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a Toroidal configuration (Torus) and the second is an actively shielded solenoidal magnet (Solenoid). Both the torus and solenoid are located in close proximity to one another and are surrounded by sensitive detectors. This paper investigates the electromagnetic interactions between the two systems during normal operation as well as during various fault scenarios as part of a Risk Assessment and Mitigation (RAM).

Torus, actively shielded, Solenoid, SSC-NbTi,Ruthe↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

Final Assembly and Factory Testing of the Jefferson Lab SHMS Spectrometer Quadrupole and Dipole Superconducting Magnets

Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface, burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting Magnet Power Supply and Hard-Wired Quench Protection at Jefferson Lab for 12 GeV Upgrade

The superconducting magnet system in Hall B being designed and built as part of the Jefferson Lab 12 GeV upgrade requires powering two conduction cooled superconducting magnets - a torus and a solenoid. The torus magnet is designed to operate at 3770 A and solenoid at 2416 A. Failure Modes and Effects Analysis (FMEA) determined that voltage level thresholds and dump switch operation for magnet protection should be tested and analyzed before incorporation into the system. The designs of the quench protection and voltage tap sub-systems were driven by the requirement to use a primary hard-wired quench detection sub-system together with a secondary PLC-based protection. Parallel path voltage taps feed both the primary and secondary quench protection sub-systems. The PLC based secondary protection is deployed as a backup for the hard-wired quench detection sub-system and also acts directly on the dump switch. Here, we describe a series of tests and modifications carried out on the magnet power supply and quench protection system to ensure that the superconducting magnet is protected for all fault scenarios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary Design Study of a Fast-Ramping Magnet for Pre-Concept Design of an Electron-Ion Collider at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. The all new ion accelerator and collider complex will consist of two collider rings with a unique figure-of-eight layout to deliver a high degree of polarization in both beams. As part of the pre-concept design for the Ion ring, a 3-Tesla Super-Ferric dipole magnet was proposed utilizing a superconducting Cable-in-Conduit-Conductor (CICC) design to wind the coils which will be built by Texas A&M University. A first mechanical model of the winding for the 3T-SF-CICC dipole was built to validate that the winding structure provides the conductor geometry required to provide collider field homogeneity over large aperture. A rapid-cycling Booster synchrotron is required to inject 8 GeV beams to the Ion Ring. The Booster requires arc dipoles with the same field and aperture as those of the Ion Ring. Due to the design of the CICC with respect to the amount of stabilizer and the internal cooling mechanism employed, temperature rise of the coils during a quench event is much more rapid than for more conventional magnets. It is thus imperative that the magnet?s stored energy is dissipated externally to the windings to avoid overheating the CICC and to provide adequate protection during a quench. As a result, this paper presents a preliminary design study, including AC effects inside the coils and associated risks with the aim of providing guidance for the design of the full protection system for such a magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quench-Back Management for Fast Decaying Currents in SHMS Superconducting Magnets at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) of Hall C, part of the 12-GeV upgrade at Jefferson Lab, was successfully commissioned in 2017. Early operation demonstrated that fast current dumps decays of the SHMS Q2/Q3 and dipole superconducting magnets triggered quenches, causing some level of operational difficulty. Tests and detailed assessments suggest that nonquench induced fast current decay could result in substantial ac loss in the conductor and subsequently trigger a quench-back effect. The OPERA/ELECTRA software package was used to calculate the amount of heat deposited in the copper stabilizer from a fast current decay. The resistances of external energy dump resistors were lowered to slow the fast dumping of the magnet's current to reduce or eliminate the quench-back effect. A worst-case adiabatic quench scenario was analyzed, assuming no external dump resistor and no liquid helium surrounding the coil, to ensure the safety of the magnets. The stress levels in the coil imposed by winding, collaring preload, Lorentz force, and temperature gradient during a quench were also examined. The Tsai-Wu material failure criterion was used to determine the acceptable combined stress level. Linear orthotropic analysis of the coil indicates that the magnets can be operated safely with appropriately sized dump resistors. Fast dump tests with the modified dump resistors have been planned to verify the performance and suitability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Immersive Visualization Lab at Idaho National Laboratory

This article introduces the Applied Visualization Laboratory at Idaho National Laboratory, including the lab's success and challenges as an immersive visualization laboratory. Also, it discusses the future direction of the immersive virtual environment and visualization.

99 GENERAL AND MISCELLANEOUS↗

Development of vegetative oil sorghum: From lab‐to‐field

Summary Biomass crops engineered to accumulate energy‐dense triacylglycerols (TAG or ‘vegetable oils’) in their vegetative tissues have emerged as potential feedstocks to meet the growing demand for renewable diesel and sustainable aviation fuel (SAF). Unlike oil palm and oilseed crops, the current commercial sources of TAG, vegetative tissues, such as leaves and stems, only transiently accumulate TAG. In this report, we used grain (Texas430 or TX430) and sugar‐accumulating ‘sweet’ (Ramada) genotypes of sorghum, a high‐yielding, environmentally resilient biomass crop, to accumulate TAG in leaves and stems. We initially tested several gene combinations for a ‘push‐pull‐protect’ strategy. The top TAG‐yielding constructs contained five oil transgenes for a sorghum WRINKLED1 transcription factor (‘push’), a Cuphea viscosissima diacylglycerol acyltransferase (DGAT; ‘pull’), a modified sesame oleosin (‘protect’) and two combinations of specialized Cuphea lysophosphatidic acid acyltransferases and medium‐chain acyl‐acyl carrier protein thioesterases. Though intended to generate oils with medium‐chain fatty acids, engineered lines accumulated oleic acid‐rich oil to amounts of up to 2.5% DW in leaves and 2.0% DW in stems in the greenhouse, 36‐fold and 49‐fold increases relative to wild‐type (WT) plants, respectively. Under field conditions, the top‐performing event accumulated TAG to amount to 5.5% DW in leaves and 3.5% DW in stems, 78‐fold and 58‐fold increases, respectively, relative to WT TX430. Transcriptomic and fluxomic analyses revealed potential bottlenecks for increased TAG accumulation. Overall, our studies highlight the utility of a lab‐to‐field pipeline coupled with systems biology studies to deliver high vegetative oil sorghum for SAF and renewable diesel production.

59 BASIC BIOLOGICAL SCIENCES↗

Long-term monitoring experiences at the HADES underground lab and its relevance for radwaste repository monitoring

In the frame of its radwaste disposal research programme, SCK-CEN started the construction of the HADES underground research facility in 1980. Including several extensions and a comprehensive experimental programme, it has provided a lot of experience on monitoring. Monitoring is performed for many reasons: construction follow-up, field characterisation, investigation of phenomena, and model validations - in which the underground lab offers the opportunity for up-scaling conventional laboratory set-ups. Construction monitoring has allowed to develop and optimise the underground construction techniques in a previously poorly known environment, resulting in a well-mastered application of mechanised methods for gallery construction with minimal damage to the host formation. Access to this formation also allows its characterisation, both geotechnical, geological and geochemical, and the detailed investigation of phenomena such as fracturing and oxidation. Finally, instrumented set-ups allow to test various numerical models by comparing the observations with the predicted behaviour. The specific conditions of the underground laboratory put particular requirements to the sensors. These conditions include the long-term nature of many set-ups - typically several years to decades, the inaccessibility of many sensors after installation, high mechanical and water pressures, and corrosion. Combined with the fact that many sensors are custom made, obtaining and maintaining a fully functional instrumented set-up can be challenging. A lot of experience has therefore been gained which is very valuable when designing the monitoring of radwaste repositories - and it has allowed us to determine the critical success factors for monitoring. Engineers tend to look at this first from a technical viewpoint - and there are many technical aspects indeed that determine the reliability of monitoring. A first one is the combination of different observations ('redundancy') which can be implemented by the use of several sensors, different sensor principles, different (coupled) parameters, and the combination of point measurements with geophysical techniques. Cabling is also a critical issue as it is often considered as the primary enemy of barrier integrity. Minimal cabling techniques, such as distributed fibre optic monitoring and wireless signal transmission, therefore get increasing attention. Also the interpretation of the monitoring data - in particular those that are perceived as 'wrong' or 'unexpected', needs sufficient attention. The long-term experience has however also shown that the design of a monitoring programme must look beyond the technical part. In particular for long-term applications, issues such as data management and record keeping are vital to guarantee success in this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.

60 APPLIED LIFE SCIENCES↗

The Jefferson Lab tritium program of nucleon and nuclear structure measurements

In this work a series of experiments were performed in Hall A of Jefferson Lab in 2018 that used a novel tritium and helium-3 target system. These experiments took advantage of the isospin symmetry of these mirror nuclei to make precise measurements of isospin dependence in both nucleon and nuclear structure. We summarize here the design and properties of these cells, the physics measurements that have been published, and results currently under analysis from this program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential for tensor polarized deuterons in Hall D at Jefferson lab

Hall D at Jefferson lab is an ideal place to install a polarized deuteron target which can be “tensor polarized”, allowing the separation of the spin states m = 0, ±1 or the measurement of tensor asymmetries. The bremsstrahlung photon beam with 3 - 12 GeV endpoint provides very little heating or radiation damage compared to an electron beam, allowing the target to be run in frozen spin mode. Adiabatic fast passage spin manipulations can then be used to greatly enhance the population of the m = 0 spin state of the deuteron. Coherent photoproduction of ρ mesons from deuterium is sensitive to double-scattering at high momentum transfer and in the m = 0 spin state an additional sensitivity at intermediate momentum transfer opens up. In conclusion, we propose a frozen spin target for Hall D and the measurement of ρ photoproduced coherently from the deuteron as a flagship measurement.

43 PARTICLE ACCELERATORS↗

Deeply Virtual Pseudoscalar Meson Production at Jefferson Lab and Transversity GPDs

Transverse-momentum dependent parton distribution functions (TMDs) provide a description of nucleon structure in terms of the parton transverse momentum and its transverse spin. At leading twist there are eight TMDs, each offering a unique feature of quarks in a polarized or an unpolarized nucleon. The Sivers distribution is one of the most interesting TMD due to its non-universality. It has been extracted using the data from semi-inclusive deep-inelastic scattering (SIDIS), but there is no data yet from spin-dependent Drell-Yan (DY) process. Such measurement will provide a crucial test of TMD formalism which predicts an equal magnitude and opposite sign for the Sivers function extracted from SIDIS and DY process. We will discuss key future measurements of TMDs using both SIDIS and DY process with a focus on Hall A SoLID SIDIS program at Jefferson Lab.

Kubarovsky, Valery P.↗

The proton form factor ratio at low Q2: New results from Jefferson Lab

Recently an experiment at Jefferson Lab has measured the proton form factor ratio {mu}{sub p}G{sub E}{sup p}/G{sub M}{sup p}, down to Q{sup 2} {approx} 0.3 GeV{sup 2} with unprecedented precision. Based on the results from this experiment, a re-analysis was carried out for the world data on proton form factors, and a new result was extracted for the proton charge radius. The new result is consistent with published CODATA results and is at odds with the new muonic hydrogen measurement at PSI. We present the results of the new measurement, as well as discuss an upcoming experiment to measure the form factor ratio down to even lower Q{sup 2}.

08 HYDROGEN↗

Jefferson Lab 12 GeV Science Program

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab are presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

McKeown, R. D.↗

Jefferson Lab at 12 GeV: The Science Program

Jefferson Lab’s upgrade of its Continuous Electron Beam Accelerator Facility (CEBAF) has recently been completed. The project involved an upgrade of the accelerator to achieve a maximum beam energy of 12 GeV and the construction of a fourth end station, Experimental Hall D, as well as new detector equipment for two of the three existing halls (A, B, and C). A broad experimental program has been developed to map the nucleon’s intrinsic quark distributions in transverse space and in longitudinal momentum through measurements of deeply exclusive and semi-inclusive processes, and to probe color confinement by studying the spectrum of hadrons with active gluon degrees of freedom in the wave function. Other programs include the forward parton distribution function at large quark momentum fraction χ, the quark and gluon polarized distribution functions, measurements of electromagnetic form factors of the nucleon ground state and of nucleon resonance transitions at short distances, and the exploration of physics beyond the Standard Model in high-precision parity-violating processes and in the search for signals of dark matter. The higher beam energy is also suitable for exploration of quark hadronization properties using the nucleus as a laboratory. This review highlights major areas of hadron and nuclear science that will be the focus of the first 5 years of operation.

3D imaging↗

Advanced Tri-lab Software Environment (ATSE)

The Advanced Tri-lab Software Environment (ATSE) is an effort to build an open, modular, extensible, community-engaged, and vendor-adaptable software ecosystem that enables the prototyping of new technologies for improving the ASC computing environment. The initial target for ATSE is to accelerate the maturity of the Arm ecosystem for supporting ASC computing and the high-performance computing community more broadly. ATSE provides an integrated and optimized software stack that includes: 1) Application development environment and libraries including compilers, math libraries, tools, MPI, and OpenMP, 2) Low-level system software including optimized Linux, network stack, file systems, containers, and virtual machines, 3) Job scheduling and management including workload manager, application launcher, and user tools, and 4) System administration and management tools supporting booting, monitoring, and operating system image management. SAND2020-12377 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Younge, Andrew J.↗