Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

Standard Library Grid-Forming Hybrid Control Inverter-Based Resource Model Specification (REGFM_C1)

This document describes a standard library grid-forming (GFM) hybrid control inverter-based resource (IBR) model. The GFM hybrid control approach implements both a typical GFM control and a typical grid-following (GFL) control inside one single inverter simultaneously, so that it can take advantage of both methods without comprising the benefits of a typical GFM. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control blocks to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

This presentation starts with the details of IEEE 2800-2022 requirements of IBR for balanced and unbalanced faults. Then, it shows how to design a droop based GFM control to be IEEE 2800-2022 compliant. An performance evaluation is carried out to see if three OEM GFM inverters 2800-2022 compliant or not. And finally we show how IEEE 2800-2022 complaint and non-compliant GFM inverter will impact the transmission line protection elements, such as directional element and FID. Finally, recommendations are made if the GFM is not IEEE 2800-2022 compliant to disable the protection elements that rely on reliable and regulated negative sequence current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Investigation on Tuning Power–Frequency Droop for Improved Grid–Forming Inverter and Synchronous Generator Transient Load Sharing

Poor transient load sharing has been observed during the parallel operation of synchronous generators (SGs) and droop-controlled grid-forming (GFM) inverter-based resources (IBRs) in islanded microgrids. This can result in overcurrent protections, causing the inverters to trip, which leads to the collapse of voltage and frequency. In this article, small-signal analysis supported by electromagnetic transients (EMTs) simulation is performed on a detailed model of a microgrid containing IBRs and an SG to identify underdamped modes and their sensitivities to the power–frequency (P-F) droop parameter. Further EMT simulation of a more complex microgrid model with multiple GFM IBRs and SGs is performed to determine whether trends identified from the modal analysis extend to cases where the number of SGs in operation may vary. The objective is to investigate the effectiveness of tuning this parameter to reduce the likelihood of overcurrents in response to load and generation disturbances. The work uncovers both fast and slow modes of concern. Primarily, the findings show that increasing the P-F droop value improves the damping of the slower mode while degrading the damping of the faster mode, leading to an upper limit on the damping improvement of the GFM IBR output current. In EMT simulations of the more complex microgrid, the greatest damping improvement still exhibits significant maximum overshoot. Furthermore, the optimal value of the P-F droop parameter is sensitive to the number of SGs in operation. The conclusion is that tuning the P-F droop parameter is not an effective means to avoid the overcurrent tripping of GFM IBRs during response to large load or generation disturbances when operating in parallel to SGs in islanded microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Parametric Reduced-Order Model for Inverter Short-Circuit Response in Protection Studies

This paper presents a reduced-order model (ROM) for grid-following (GFL) inverters that reproduces inverter fault current trajectories, including sub transients, transient, and steady-state phases, across a range of fault types, locations, and pre-fault operating points. . The proposed model is developed by: Constructing the positive- and negative-sequence current with parameterization fitted by large data training and fitting Validating using EMT simulation against EMT full model and demonstrating the ROM's capability to capture fault current magnitude, phase angle, and oscillatory transients. Building a standard EMT simulation platform library component for easy configuration and application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Time-Disciplined Non-PLL Active Synchronization for Grid-Forming Inverters: Preprint

Grid Forming Inverters (GFMIs) are a critical component of the future Grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) Initial Grid Synchronization, (2) Ride-Through, (3) Blackstart Coordination, (4) Grid Reconnection Coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper’s framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant Grid.

blackstart↗

Time Disciplined Non-PLL Active Synchronization for Grid Forming Inverters

Grid forming inverters (GFMIs) are a critical component of the future grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) initial grid synchronization, (2) ride-through, (3) blackstart coordination, (4) grid reconnection coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper's framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant grid.

blackstart↗

Enabling Interoperability on PV Inverters Using IEC 61850

Inverter based distributed energy resources are integrated into distribution system at a fast pace. Distribution management systems, microgrid controllers, and other distributed assets need to communicate with each other for sensing and control of the different assets. Interoperability is critical to the ease of data exchange between different assets. This presentation will provide a background on interoperability and a laboratory implementation using IEC 61850. Specifically, this presentation will discuss the use of IEC 61850 7-420 to enable interoperability in PV inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Inner-Loop Control Method for the Filter-less, Voltage Sensor-less, and PLL-less Grid-Following Inverter-Based Resource

This paper presents a novel inner-loop control method for the inverter-based resource (IBR). The innovative concepts include removing the voltage sensors at the point of common coupling (PCC), removing the inverter interface inductance, and removing the traditional phase-locked loop (PLL) circuits. Simulation is conducted to verify the feasibility of the method. Furthermore, the virtual impedance is applied to the control loop to improve the current THD and dynamics. Compared to the traditional control, the proposed one helps offload the system by reducing the bulky inductors and voltage sensors without compromising the control performance.

grid-forming inverter, inner-loop control, filterl↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Invertible Neural Networks for Aerodynamic Design of Wind Turbine Blades

The state-of-the-practice methods for aerodynamic design of wind turbine blads use linearized blade element momentum theory (BEM) to optimize the twist and chord profiles from a pre-selected set of 2D airfoil shapes. In this work, we apply invertible neural network (INN) tools to enable the rapid inverse aerodynamic design of wind turbine blades including component airfoils. The INN is trained on data obtained through the use of robust automated mesh generation and the HAMSTR computational fluid dynamics solver with advanced turbulence and transition models validated for turbine applications. Our design technique is a significant improvement over the state-of-the-practice linearized blade element momentum (BEM) techniques in capturing 3D nonlinear aerodynamic effects that are critical for optimal design of the rotors. This is made possible by developing sparse, invertible neural networks (INNs) for inverse design and optimization that realize a 100x cost reduction compared to adjoint-based computational fluid dynamics (CFD) approaches, while enabling increased robustness of the final design. We demonstrate the INN tool for design of a section of the NREL 5-MW blade. All generated shapes satisfy the desired aerodynamic characteristics, demonstrating the success of the INN approach for inverse design of wind turbine blades.

aerodynamic design↗

Grid-Forming Inverters - Enabling the Next Generation Grid

NREL's Power Electronic Grid Interface (PEGI) Workshop, held October 13, 2020, focused on the research challenges of operating power systems with ever-higher levels of inverter-based generation and power-electronic-based load. This presentation discusses grid-forming inverters and enabling the next generation grid.

grid↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs: Preprint

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.

frequency-shaping control↗