Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Velocity and temperature decay characteristics of inverted-profile jets

In order to design efficient, lightweight flap systems for future engine under-the-wing STOL aircraft, the velocity and temperature decay rate of the jet plume must be increased relative to that for single-stream nozzles in order to provide local flap loads and structural temperatures within acceptable limits. The jet plume decay rate of dual flow engines can be increased by resorting to inverted-profile velocity and temperature nozzle concepts. The peak axial decay characteristics of model-scale, two-stream inverted-profile nozzle flows are empirically correlated. Also discussed are the radial and spreading characteristics of inverted-profile nozzle flows.

Vonglahn, U.↗

Plume characteristics of single-stream and dual-flow conventional and inverted-profile nozzles at equal thrust

The plume velocity and temperature decay rates of single-stream, conventional dual-flow and inverted-profile dual-flow nozzles are compared at equal values of ideal thrust over a wide range of flow conditions. The comparisons are made in terms of constant velocity and temperature contour maps. The results show that both dual-flow nozzle types have much greater plume velocity and temperature decay rates than those of equivalent thrust single-stream nozzles when the respective secondary flows were at ambient temperature. With hot secondary flows, the inverted-profile dual-flow plumes decayed significantly faster than those of single-stream nozzles; however, the decay rates for the conventional dual-flow streams were about the same as those for the single-stream nozzles. Consequently, with hot secondary flows, the inverted-profile dual-flow plumes decayed much faster than the conventional dual-flow plumes at equal thrust.

Vonglahn, U. H.↗

Velocity and temperature decay characteristics of inverted-profile jets

In order to design efficient, lightweight flap systems for future engine under-the-wing STOL aircraft, the velocity and temperature decay rate of the jet plume must be increased relative to that for single-stream nozzles in order to provide local flap loads and structural temperatures within acceptable limits. The jet plume decay rate of dual flow engines can be increased by resorting to inverted-profile velocity and temperature nozzle concepts. The peak axial decay characteristics of model-scale, two-stream inverted-profile nozzle flows are empirically correlated. Also discussed are the radial and spreading characteristics of inverted-profile nozzle flows.

Von Glahn, U.↗

Dynamics of liquid sloshing in upright and inverted bladdered tanks

A system identification methodology was used to examine the dynamics of liquid sloshing in the upright and inverted bladdered hydrazine tanks of the Tracking and Data Relay Satellite, (TDRS) and to evaluate the effects of bladder stiffness on the sloshing parameters. Mechanical models of the two systems were developed using the numerical values derived from static stability tests and from slosh frequency response tests of a full-size model tank fitted with a prototype bladder. For the upright tank (liquid below the bladder) a modified conventional pendulum was used. In the inverted tank (liquid above the bladder) where sloshing is unconventional due to the highly nonsymmetrical orientation of the liquid held by the bladder, a mechanical model using an inverted pendulum which is able to undergo small oscillations as well as large reorientations was necessary. Both thrusting and low-gravity conditions are considered.

Dodge, F. T.↗

Plume characteristics of single-stream and dual-flow conventional and inverted-profile nozzles at equal thrust

The plume velocity and temperature decay rates of single-stream, conventional dual-flow and inverted-profile dual-flow nozzles are compared at equal values of ideal thrust over a wide range of flow conditions. The comparisons are made in terms of constant velocity and temperature contour maps. The results show that both dual-flow nozzle types have much greater plume velocity and temperature decay rates than those of equivalent thrust single-stream nozzles when the respective secondary flows were at ambient temperature. With hot secondary flows, the inverted-profile dual-flow plumes decayed significantly faster than those of single-stream nozzles; however, the decay rates for the conventional dual-flow streams were about the same as those for the single-stream nozzles. Consequently, with hot secondary flows, the inverted-profile dual-flow plumes decayed much faster than the conventional dual-flow plumes at equal thrust.

Von Glahn, U. H.↗

An in situ evaluation of TOPEX/Poseidon altimetric measurements versus meaurements made by moorings and inverted echo sounders for sea surface height

The classical method of observing the sea surface height has been to make shipboard measurements of the vertical - density profile, and then calculating the surface height relative to a deeper reference surface. Two methods (a moored vertical string of instruments and an inverted echo sounder) were subsequently developed to obtain longer time in situ measurements. The first of these can be thought of as an extension of the discrete bottle hydrocast while the second integrates acoustically over the water column. One purpose of this note is to compare the result when coincidental observations are made by these two methods. This was done at two sites in the western tropical Pacific. Two inverted echo sounders were deployed alongside two enhanced TOGA-COARE moorings to be used in an in situ evaluation of TOPEX/Poseidon altimetric measurements of sea surface height. The mooring and inverted echo sounder data reproduced one another, at low frequency, with a correlation of 0.93 and 0.95 and the altimeter correlated with each of the above values ranging from 0.84 to 0.94. It is concluded that the altimetric measurements are statistically equivalent to the in situ measurements in the area of study.

Source record↗

Noise from Supersonic Coaxial Jets: Inverted Velocity Profile - Part 3

The instability wave noise generation model is used to study the instability waves in the two shear layers of an inverted velocity profile, supersonic, coaxial jet and the noise radiated from the dominant wave. The inverted velocity profile jet has a high speed outer stream surrounding a low speed inner stream and the outer shear layer is always larger than the inner shear layer. The jet mean flows are calculated numerically. The operating conditions are chosen to exemplify the effect of the coaxial jet outer shear layer initial spreading rates. Calculations are made for the stability characteristics in the coaxial jet shear layers and the noise radiated from the instability waves for different operating conditions with the same total thrust, mass flow and exit area as a single reference jet. Results for inverted velocity profile jets indicate that relative maximum instability wave amplitudes and far field peak noise levels can be reduced from that of the reference jet by having higher spreading rates for the outer shear layer, low velocity ratios, and outer streams hotter than the inner stream.

Dahl, Milo D.↗

Suspended Patch Antenna Array With Electromagnetically Coupled Inverted Microstrip Feed

The paper demonstrates a four-element suspended patch antenna array, with a parasitic patch layer and an electromagnetically coupled inverted microstrip feed, for linear polarization at K-Band frequencies. This antenna has the following advantages over conventional microstrip antennas: First, the inverted microstrip has lower attenuation than conventional microstrip; hence, conductor loss associated with the antenna corporate feed is lower resulting in higher gain and efficiency. Second, conventional proximity coupled patch antennas require a substrate for the feed and a superstrate for the patch. However, the inverted microstrip fed patch antenna makes use of a single substrate, and hence, is lightweight and low cost. Third, electromagnetic coupling results in wider bandwidth. Details regarding the design and fabrication will be presented as well as measured results including return loss, radiation patterns and cross-polarization levels.

Simons, Rainee N.↗

Minimizing Gravity Sag of a Large Mirror with an Inverted Hindle-Mount

A method of minimizing the optical distortion from gravity sag on a suspended large autocollimating flat mirror has been devised. This method consists of an inverted nine-point Hindle-Mount. A conventional Hindle-mount is located underneath a sky-viewing mirror and is primarily under compression loads from the weight of the mirror. It is not suitable for the situation where the mirror is viewing the ground, since a mirror would tend to fall out of the mount when in an inverted position. The inverted Hindle-Mount design consists of bonded joints on the backside of the mirror that allow the mirror to be held or suspended above an object to be viewed. This ability is useful in optical setups such as a calibration test where a flat mirror is located above a telescope so that the telescope may view a known optic.

Robinson, David W.↗

Motor/Generator and Inverter Characterization for Flywheel System Applications

The Advanced Electrical Systems Development Branch at NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheels systems for satellite energy storage and attitude applications. These flywheels will serve as replacement for chemical nickel hydrogen, nickel cadmium batteries and gyroscopic wheels. The advantages of using flywheel systems for energy storage on satellites are high energy density, high power density, long life, deep depth of discharge, and broad operating temperature ranges. A flywheel system for space applications consist of a number of flywheel modules, the motor/generator and magnetic bearing, and an electronics package. The motor/generator electronics package includes a pulse-width modulated inverter that drives the flywheel permanent magnet motor/generator located at one end of the shaft. This summer, I worked under the direct supervision of my mentor, Walter Santiago, and the goal for this summer was to characterize motor generator and inverter attributes in order to increase their viability as a more efficient energy storage source for space applications. To achieve this goal, magnetic field measurements around the motor/generator permanent magnet and the impedance of the motor/generator three phase windings were characterized, and a recreation of the inverter pulse width modulated control system was constructed. The Flywheel modules for space use are designed to maximize energy density and minimize loss, and attaining these values will aid in locating and reducing losses within the flywheel system as a whole, making flywheel technology more attractive for use as energy storage in future space applications.

Tamarcus, Jeffries L.↗

FET commutated current-FED inverter

A shunt switch comprised of a field-effect transistor (Q.sub.1) is employed to commutate a current-fed inverter (10) using thyristors (SCR1, SCR2) or bijunction transistors (Q.sub.2, Q.sub.3) in a full bridge (1, 2, 3, 4) or half bridge (5, 6) and transformer (T.sub.1) configuration. In the case of thyristors, a tapped inverter (12) is employed to couple the inverter to a dc source to back bias the thyristors during commutation. Alternatively, a commutation power supply (20) may be employed for that purpse. Diodes (D.sub.1, D.sub.2) in series with some voltage dropping element (resistor R.sub.12 or resistors R.sub.1, R.sub.2 or Zener diodes D.sub.4, D.sub.5) are connected in parallel with the thyristors in the half bridge and transformer configuration to assure sharing the back bias voltage. A clamp circuit comprised of a winding (18) negatively coupled to the inductor and a diode (D.sub.3) return stored energy from the inductor to the power supply for efficient operation with buck or boost mode.

Rippel, Wally E.↗

Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

MacLeod, Todd C.↗

Switching Characteristics of Ferroelectric Transistor Inverters

This paper presents the switching characteristics of an inverter circuit using a ferroelectric field effect transistor, FeFET. The propagation delay time characteristics, phl and plh are presented along with the output voltage rise and fall times, rise and fall. The propagation delay is the time-delay between the V50% transitions of the input and output voltages. The rise and fall times are the times required for the output voltages to transition between the voltage levels V10% and V90%. Comparisons are made between the MOSFET inverter and the ferroelectric transistor inverter.

Laws, Crystal↗

Static Characteristics of the Ferroelectric Transistor Inverter

The inverter is one of the most fundamental building blocks of digital logic, and it can be used as the foundation for understanding more complex logic gates and circuits. This paper presents the characteristics of an inverter circuit using a ferroelectric field-effect transistor. The voltage transfer characteristics are analyzed with respect to varying parameters such as supply voltage, input voltage, and load resistance. The effects of the ferroelectric layer between the gate and semiconductor are examined, and comparisons are made between the inverters using ferroelectric transistors and those using traditional MOSFETs.

Mitchell, Cody↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Three-phase, three-level inverters and methods for performing soft switching with phase synchronization

A three-phase, N-level inverter and method are disclosed. A circuit topology of the inverter comprises first, second and third sets of switches and first, second and third inductors. Each switch comprises at least first, second and third terminals, the first terminals being control terminals. The first terminals of the first, second and third inductors are electrically coupled to the first, second and third sets of switches, respectively. A current controller performs a control algorithm that causes it to output first, second and third sets of gating signals to the control terminals of the switches of the first, second and third sets of switches, respectively, to cause them to be placed in an on state or an off state in a particular sequence to perform zero voltage switching while maintaining synchronization of the three phases of the three-phase, N-level inverter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

PV Inverter Failures Cause AC Breaker Damage - Power Quality

This poster discusses how PV inverter failures cause AC breaker damage and is intended to help system owners identify power quality issues and origins, help inverter and/or circuit breaker manufacturers develop safer failure modes, and develop addendums to standards for failure testing of breakers and inverters.

arc↗