Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Xenon doping of Liquid Argon in ProtoDUNE Single Phase: first results

Doping Liquid Argon (LAr) with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength to ease its detection. The largest Xenon doping test ever performed in a LArTPC was carried out in ProtoDUNE Single Phase (ProtoDUNE-SP) at the CERN Neutrino Platform. The response of such a large TPC (7701 of Liquid Argon and 4401 of fiducial mass) has been studied using the ProtoDUNE Photon Detection System (PDS) and a dedicated setup installed before the run. With the first, it was possible to study the light detected in the system as a function of the xenon concentration and to characterise the light collection efficiency with respect to the track position. With the second system it was possible to disentangle the LAr (128 nm) light from the xenon (178 nm) light using two dedicated X-ARAPUCA modules. The run was fully satisfactory, it was possible to measure directly the increase of the xenon light component during doping; furthermore most of the LAr light quenched by impurities was fully recovered even at small Xenon concentration (< 20 ppm in mass). A study of the collected scintillation light as a function of the track position showed an improvement of the detector response uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Improving Fission Products at CARIBU: Near Field Detection (Q3/FY21 Quarterly Progress Report)

The overview of our project as well as most recent results have been presented at the NSARD review in April, and more recently during the WoNDRAM workshop. We have been dealing with recent personnel changes in the group. Miguel Bencomo, who has worked with us on this project as a postdoc at LLNL since 2019, will be terminating his appointment within the next two weeks to take a full-time appointment with Raytheon. We continue training our new team member Dan Hoff to take over data analysis from the last experiment we performed, as well as prepare for upcoming measurements. Additionally, we are working with a summer student, John Wilkinson, who is training to perform GEANT4 simulations of beta detector this summer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct reactions for astrophysical p-capture rates with ORRUBA and GODDESS

Understanding the nucleosynthesis and energy generation in quiescent and explosive stellar burning requires a detailed understanding of reaction rates on many unstable nuclides. Such reaction rates are often governed by the properties of low-lying, isolated proton resonances. Though direct measurements of resonance strengths are ultimately desired, and are a focus of rare isotope beam facilities worldwide, such tour-de-force experiments must be guided by indirect techniques, in order to know resonance energies, J π assignments, and estimated widths, to inform targeted measurements. Furthermore, some important low-lying resonances may be too weak for direct measurements with radioactive beams, and indirect techniques provide the only practical constraints. Additionally, there has been growing interest in the astrophysical role of isomeric states, which can influence the reaction flow in nucleosynthetic reaction networks, and hence impact the quantitative interpretation of astronomical observables, such as γ-ray signatures, and elemental and isotopic ratios. Properties of single-proton resonances can be obtained by exploiting the selectivity of direct reactions, such as single-nucleon transfer and charge-exchange reactions. Constraining proton-capture rates via direct reactions has been a focus of the astrophysics program at ORNL for over two decades, spurring the development of the ORRUBA and GODDESS detector systems. Herein, a review of recent developments in instrumentation and radioactive beam delivery (including isomeric beam experiments) is presented, along with some specific examples of astrophysically interesting sd-shell nuclides, which have been a target of recent ORRUBA and GODDESS experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

CTN-004: Rubin Observatory Raw Data File Format

At the NSF-DOE Vera C. Rubin Observatory we write data from the LSSTCam and LATISS instruments using FITS format with one file written per detector. Here we discuss the layout of those FITS files and describe the FITS headers.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Optimizing observables with machine learning for better unfolding

Most measurements in particle and nuclear physics use matrix-based unfolding algorithms to correct for detector effects. In nearly all cases, the observable is defined analogously at the particle and detector level. We point out that while the particle-level observable needs to be physically motivated to link with theory, the detector-level need not be and can be optimized. We show that using deep learning to define detector-level observables has the capability to improve the measurement when combined with standard unfolding methods.

47 OTHER INSTRUMENTATION↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Dark matter detection capabilities of a large multipurpose Liquid Argon Time Projection Chamber

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE) . Here in this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivity argon, which may be commercially available on that timescale, along with a significant increase in light detection, one DUNE-like module gives a competitive WIMP detection sensitivity, particularly above a dark matter mass of 100 GeV.

47 OTHER INSTRUMENTATION↗

A 32-channels readout ASIC for X-ray spectrometry and tracking in the GAPS experiment

Here this work describes the architecture and the experimental results from the characterization of a 32-channels mixed-signal Application-Specific Integrated Circuit (ASIC) developed for the readout of the lithium-drifted silicon, Si(Li), detectors of the General AntiParticle Spectrometer (GAPS) experiment dedicated to searching for dark matter. The instrument is designed for the identification of antiprotons, antideuterons and antihelium nuclei from cosmic rays during an Antarctic balloon mission scheduled for late 2024. A full custom integrated circuit, named SLIDER32 (32-channels Si-LI DEtector Readout) ASIC, has been produced in a commercial 180 nm CMOS technology. The ASIC is comprised of 32 low-noise analog readout channels featuring dynamic signal compression to comply with the wide input range, an 11-bit SAR ADC and a digital back-end section which is responsible for channel setting and for sending digital information to the data acquisition system (DAQ). The circuit design criteria and the experimental results are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗