Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inertia”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM’s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 µm. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

Symmetry and Shape Coexistence in 10 Be

Within the low-lying spectrum of 10 Be, multiple rotational bands are found, with strikingly different moments of inertia. A proposed interpretation has been that these bands variously represent triaxial rotation and prolate axially-deformed rotation. The bands are well-reproduced in ab initio no-core configuration interaction (NCCI) calculations. Here, we use the calculated wave functions to elucidate the nuclear shapes underlying these bands, by examining the Elliott SU(3) symmetry content of these wave functions. The ab initio results support an interpretation in which the ground-state band, along with an accompanying K = 2 side band, represent a triaxial rotor, arising from an SU(3) irreducible representation in the 0hw space. Then, the lowest excited K = 0 band represents a prolate rotor, arising from an SU(3) irreducible representation in the 2hw space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments to explore the influence of pulse shaping at the National Ignition Facility

The shaping of the drive pulse in time is a key tool in the design of fusion experiments that use inertia to confine burning plasmas. It is directly related to the adiabat and compressibility of the DT fuel, and the characteristics of the laser and target that are needed to ignite. With this in mind, we have performed experiments at the National Ignition Facility that test small changes in the shape of the pulse. In contrast to theory, we find implosions at lower adiabats can have reduced yield and areal density. We discuss implications to performance and the mechanism(s) that could be responsible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Active Damping With Energy Storage to Improve Power System Frequency Stability

As renewable resources displace traditional generation, there may be times when there is relatively less rotational inertia (H, MW-s) to stabilize power system frequency following a power system disturbance. This article outlines a method for the control of Battery Energy Storage System (BESS) to mitigate power system frequency disturbances. The control scheme discussed in the article leverages latest ‘smart grid’ technologies including PMU’s and advanced grid-supportive inverters. The authors’ screening-level analysis of this novel BESS control concept indicates the potential to increase the speed of recovery of disturbed power systems, i.e. return power system frequency to nominal value (60 Hz in N. America), following a system disturbance. Increasing power system stability by adding inertial-support from appropriately controlled BESS will help power systems accommodate more renewable generation before hitting stability limits.

Energy Storage↗

Standing Shock Regulates Sparks in Explosive Flows

Electric sparks and explosive flows have long been associated with each other. Flowing dust particles originate charge through contact electrification and separate based on inertia, resulting in strong electric fields supporting sparks. These sparks can cause explosions in dusty environments, especially those rich in carbon, such as coal mines and grain elevators. Recent observations of explosive events in nature and decompression experiments indicate that supersonic flows of explosions may alter the electrical discharge process. Shocks may suppress parts of the hierarchy of the discharge phenomena, such as leaders. In our decompression experiments, a shock tube ejects a flow of gas and particles into an expansion chamber. We imaged an illuminated plume from the decompression of a mixture of argon and < 100 mg of diamond particles. We also performed hydrodynamics simulations of the decompression event that provide insight into the conditions supporting the observed behavior. The sparks occur below the sharp boundary of a condensation cloud. These results agree closely with the Mach disk shock shape and height in the simulation. This represents direct evidence that the sparks are sculpted by the outflow. The spatial and temporal scale of the sparks transmit an impression of the shock tube flow, a connection that could enable novel instrumentation to diagnose currently inaccessible supersonic granular phenomena.

36 MATERIALS SCIENCE↗

A hub and spoke approach to optimizing energy wheeling of renewable resources

The deployment of zero carbon renewable energy sources needs to increase significantly to support the goal of net zero greenhouse gas emissions by 2050. At the same time energy end use needs to decarbonize. This will change both energy supply and energy demand patterns, requiring the energy delivery infrastructure (grid-based transmission circuits) to become increasingly flexible to maintain security of supply everywhere and always. The integration of zero carbon renewable energy requires cross-border and cross energy system coupling and a fit-for-purpose design. Nowadays, energy systems are planned, designed and operated in silos with a strong national focus. However, large-scale offshore wind production needs to be transported to deep inland locations, across country borders. The increased peak generation capacity of renewable energy sources will, at times, significantly exceed demand (Matthew Langholtz, 2020). The traditional solution of continuously reinforcing and extending the electricity grid is not sustainable from a cost and societal perspective. This paper will, however, propose a deterministic approach on how networked (interconnected grid) Points of receipt (POR) to Points of Delivery (POD) can be optimized for wheeling renewable energy resources while minimizing energy cost with a hub and spoke approach. The statistical approach will be done via using existing daily energy market clearing prices, available transmission capacity and firm daily transmission prices in open access energy markets. Renewable energy targets, including specific offshore wind targets, need to be in line with the ramp-up as implied by the Paris Agreement. These targets are required to provide industry with a secure market outlook that allows them to build up supply chains accordingly. Optimizing wheeled energy paths from carbon neutral resources such as renewables make them not only cost competitive on the unit commitment stack, but also more accessible on the dispatch stack to other carbon heavy forms of generation such as coal and natural gas turbines (Matthew Langholtz, 2020). This correlates to maximizing renewable resource inertia (wind, solar, biomass) within an interconnected grid without having to consider additional expansion of resources via land purchases and de-forestation.

Mukherjee, Srijib↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems: Preprint

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different sets of preprocess data for the prediction of the frequency nadir in the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. The training and testing data sets are collected by extensive generation scheduling simulations on the Multi-timescale Integrated Dynamic and Scheduling (MIDAS) toolbox. Numerical results show that all five machine learning methods can achieve high performance accuracy for power system nadir frequency estimation. Among them, the gradient boosting and the XGBoost are clear winners by providing the best prediction accuracy.

data driven↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

An Efficient Time-Domain Model to Simulate Parametric Resonances in a Floating Body Free to Move in Six Degrees of Freedom: Preprint

We present a computationally efficient time-domain model capable of simulating parametric resonances in a floating body in waves. The model assumes all wave forces to be linear, but the inertia and restoring forces acting on the body are expanded to second order in body motions. The simulation speed on a standard computer is approximately 40 times faster than real time. The model is applied to a soft-moored floating axisymmetric body which absorbs energy through heave, but is otherwise free to move in six degrees of freedom. Under certain conditions, we show that the body responds parametrically with large amplitudes not only in surge and pitch, but also in sway, roll, and yaw, provided it is given some small initial displacement in one of these out-of-plane modes. The predictions are confirmed by simulations using state-of-the-art nonlinear Froude-Krylov and computational fluid dynamics models.

parametric resonance↗

DynaShape: Dynamic Shaping of Grid Response with Inverters

We consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

frequency-shaping control↗

On Practical Aspects of Variational Consistency in Contact Dynamics

Usage of contact mechanics methodologies is a pervasive modeling requirement in dynamic simulations. While for some trivial problems, solutions taken from analytical geometry are available, use of a finite element framework is common to achieve formulation generality. This work explores two dynamic contact formulations: one based on the traditional node-to-segment (NTS) approach, and a variationally consistent segment-to-segment (STS) mortar formulation. The NTS formulation employed here enforces the constraints kinematically (i.e., the interpenetration is enforced to the solver tolerance), whereas the mortar approach uses Lagrange multipliers to enforce the contact constraints. Both approaches are implemented in the open-source finite element framework Multiphysics Object-Oriented Simulation Environment (MOOSE). The results highlight two relevant contact-interface-related dynamic phenomena in finite element simulations. First, stabilization of contact constraints is discussed, taking into account the evolution of the total energy in a benchmark problem. Second, the influence of finite element discretization on both of the aforementioned contact formulations is analyzed by exercising a large-deformation example with continuous relative sliding. Variationally consistent contact approaches such as the mortar formulation lead to improved energy preservation and avoid spurious excitation of the system's frequencies. This is especially relevant in settings where inertia and vibrations are of importance.

42 ENGINEERING↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗

Fluid power circuit having switch-mode power transformer and methods

A fluid power circuit with a switch-mode power transformer used to transfer power while keeping the pressure of power source and reverse osmosis processes relatively decoupled. The switch-mode power transformer uses the inertia of a hydraulic motor driven electric generator and switching of a hydraulic motor inlet between high and low-pressure ends to decrease the pressure at which power is being transmitted to a reverse osmosis process.

Simmons, II, Jeremy W.↗

Amphiphilic Block Copolymers for Flocculation and Hydrophobization of Legacy Waste Suspensions in Flotation Driven Dewatering Operations

There exists a degrading legacy fuel pond at the Sellafield site (UK), known as the First-Generation Magnox Storage Pond (FGMSP). After being placed into a passive care and maintenance regime resulting in a long storage period, the fuel rods, primarily their cladding, corroded in the pond forming magnesium hydroxide based sludges and suspended material. These ponds are a grave concern to the British government in terms of hazard and risk reduction. Therefore, decommissioning of these ponds is a top priority beginning with the contaminant retrievals process [1]. The pond has accumulated significant quantities of waste materials amongst the skips of fuel, including but not limited to: large inventories of corroded Magnox sludge, fuel rod fragments, metal fragments (from fuel skips), concrete degradation products (from the pond infrastructure), wind-blown sand, and other materials such as bird guano and animal remains. This challenge requires a chemically robust technology to complete sludge retrievals [2]. As nuclear is different, a more stringent process operation criteria is required. From the criteria, flotation was selected as a viable technology. Flotation involves the application of collector molecules which modify the hydrophobicity of suspended particles allowing them to adsorb to rising bubbles. As some particles lack inertia for flotation due to their size, dual flocculant/collector agents can be deployed for greater particle recovery, in this case, amphiphilic diblock copolymers. Two copolymers of Poly(acrylic acid)-b-poly(n-butyl acrylate) (or PAA-b-PnBA), of different hydrophobic chain lengths (PBA) were synthesized for flotation campaigns. Flotation has shown promise to be a valuable rapid dewatering strategy for decommissioning of legacy waste ponds whilst upholding the required operational criteria. This research has shown: PAA-b-PnBA copolymers promote flocculation of Mg(OH){sub 2} particulates. Diblock copolymers retain more fluid than traditional surfactant based collectors wrt. relative particulate recovery performance- where longer PnBA chain length polymers performed best. Performance appears to be hydrodynamically limited due to over-flocculation of Mg(OH){sub 2}. Potential to combine with sedimentation for high particle recovery with low fluid carryover.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗