Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

IER-484 CED4a Report: AFRRI ER1 Dosimetry Characterization

This report presents an analytical function as the reference neutron and photon dose (normalized to an ion chamber integral) for future nuclear accident dosimeter (NAD) exercise at the Armed Forces Radiobiology Research Institute (AFRRI). Various dosimeters and equipment were positioned within exposure room 1 (ER1) and irradiated using a 1.1 MW Training, Research, Isotope, General Atomics (TRIGA) Mark-F nuclear reactor. An ion chamber located in ER1 was used as a normalization factor in Equation 2. This allows for a quick calculation of neutron and photon dose based on the ion chamber data. Currently, AFRRI is in preparation to host a NAD exercise this summer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation

The implantation energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation (EGD-PIII) is investigated numerically and experimentally. Depth profiles obtained from different samples processed by EGD-PIII and traditional PIII are compared. The retained doses under different pulse widths are calculated by integrating the area under the depth profiles. Our results indicate that the improvement in the impact energy and retained dose uniformity by this technique is remarkable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A planning study of simultaneous integrated boost with forward IMRT for multiple brain metastases

The objective of this study was to evaluate the dose conformity and feasibility of whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in patients with 1 to 3 brain metastases. Forward intensity-modulated radiation therapy plans were generated for 10 patients with 1 to 3 brain metastases on Pinnacle 6.2 Treatment Planning System. The prescribed dose was 30 Gy to the whole brain (planning target volume [PTV]{sub wbrt}) and 40 Gy to individual brain metastases (PTV{sub boost}) simultaneously, and both doses were given in 10 fractions. The maximum diameters of individual brain metastases ranged from 1.6 to 6 cm, and the summated PTVs per patient ranged from 1.62 to 69.81 cm{sup 3}. Conformity and feasibility were evaluated regarding conformation number and treatment delivery time. One hundred percent volume of the PTV{sub boost} received at least 95% of the prescribed dose in all cases. The maximum doses were less than 110% of the prescribed dose to the PTV{sub boost}, and all of the hot spots were within the PTV{sub boost}. The volume of the PTV{sub wbrt} that received at least 95% of the prescribed dose ranged from 99.2% to 100%. The mean values of conformation number were 0.682. The mean treatment delivery time was 2.79 minutes. Ten beams were used on an average in these plans. Whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in 1 to 3 brain metastases is feasible, and treatment delivery time is short.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiscale Modeling of Total Ionizing Dose Effects in Commercial-off-the-Shelf Parts in Bipolar Technologies

A multiscale modeling platform that supports the “virtual” qualification of commercial-off-the-shelf parts is presented. The multiscale approach is divided into two modules. The first module generates information related to the bipolar junction transistor gain degradation that is a function of fabrication process, operational, and environmental inputs. The second uses this information as inputs for radiation-enabled circuit simulations. The prototype platform described in this paper estimates the total ionizing dose and dose rate responses of linear bipolar integrated circuits for different families of components. The simulation and experimental results show good correlation and suggest this platform to be a complementary tool within the radiation-hardness assurance flow. Finally, the platform may reduce some of the costly reliance on testing for all systems.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-450: The Investigation of Radiotherapy Quality Assurance and Automatic Treatment Planning Based On the Kernel Density Estimation Method

Purpose: To develop a fast automatic algorithm based on the two dimensional kernel density estimation (2D KDE) to predict the dose-volume histogram (DVH) which can be employed for the investigation of radiotherapy quality assurance and automatic treatment planning. Methods: We propose a machine learning method that uses previous treatment plans to predict the DVH. The key to the approach is the framing of DVH in a probabilistic setting. The training consists of estimating, from the patients in the training set, the joint probability distribution of the dose and the predictive features. The joint distribution provides an estimation of the conditional probability of the dose given the values of the predictive features. For the new patient, the prediction consists of estimating the distribution of the predictive features and marginalizing the conditional probability from the training over this. Integrating the resulting probability distribution for the dose yields an estimation of the DVH. The 2D KDE is implemented to predict the joint probability distribution of the training set and the distribution of the predictive features for the new patient. Two variables, including the signed minimal distance from each OAR (organs at risk) voxel to the target boundary and its opening angle with respect to the origin of voxel coordinate, are considered as the predictive features to represent the OAR-target spatial relationship. The feasibility of our method has been demonstrated with the rectum, breast and head-and-neck cancer cases by comparing the predicted DVHs with the planned ones. Results: The consistent result has been found between these two DVHs for each cancer and the average of relative point-wise differences is about 5% within the clinical acceptable extent. Conclusion: According to the result of this study, our method can be used to predict the clinical acceptable DVH and has ability to evaluate the quality and consistency of the treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-I-16: Scan Length Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

Purpose: The area-averaged dose in the central plane of a long cylinder following a CT scan depends upon the radial dose distribution and the length of the scan. The ICRU/TG200 phantom, a polyethylene cylinder 30 cm in diameter and 60 cm long, was the subject of this study. The purpose was to develop an analytic function that could determine the dose for a scan length L at any point in the central plane of this phantom. Methods: Monte Carlo calculations were performed on a simulated ICRU/TG200 phantom under conditions of cylindrically symmetric conditions of irradiation. Thus, the radial dose distribution function must be an even function that accounts for two competing effects: The direct beam makes its weakest contribution at the center while the scatter begins abruptly at the outer radius and grows as the center is approached. The scatter contribution also increases with scan length with the increase approaching its limiting value at the periphery faster than along the central axis. An analytic function was developed that fit the data and possessed these features. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the ICRU/TG200 phantom. The relative depth of the minimum decreases as the scan length grows and an absolute maximum can occur between the center and outer edge of the cylinders. As the scan length grows, the relative dip in the center decreases so that for very long scan lengths, the dose profile is relatively flat. Conclusion: An analytic function characterizes the radial and scan length dependency of dose for long cylindrical phantoms. The function can be integrated with the results expressed in closed form. One use for this is to help determine average dose distribution over the central cylinder plane for any scan length.

60 APPLIED LIFE SCIENCES↗

Acute Toxicity and Tumor Response in Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy With Shortening of the Overall Treatment Time Using Intensity-Modulated Radiation Therapy With Simultaneous Integrated Boost: A Phase 2 Trial

Background and Purpose: This phase 2 study investigated the efficacy and safety of preoperative intensity modulated radiation therapy with a simultaneous integrated boost (IMRT-SIB) without dose escalation, concomitant with standard capecitabine chemotherapy in locally advanced rectal cancer. Methods and Materials: Between January 2014 and March 2015, 51 patients with operable stage II-III rectal adenocarcinoma received preoperative IMRT with pelvic dose of 41.8 Gy and simultaneously delivered 46.2 Gy to T2/3 and 48.4 Gy to T4 tumor in 22 fractions, concomitant with capecitabine, 825 mg/m{sup 2}/12 hours, including weekends. The primary endpoint was pathologic complete response (pCR). Results: Fifty patients completed preoperative treatment according to the protocol, and 47 underwent surgical resection. The sphincter preservation rate for the low rectal tumors was 62%, and the resection margins were free in all but 1 patient. Decrease in tumor and nodal stage was observed in 32 (68%) and 39 (83%) patients, respectively, with pCR achieved in 12 (25.5%) patients. There were only 2 G ≥ 3 acute toxicities, with infectious enterocolitis in 1 patient and dermatitis over the sacral area caused by the bolus effect of the treatment table in the second patient. Conclusions: Preoperative IMRT-SIB without dose escalation is well tolerated, with a low acute toxicity profile, and can achieve a high rate of pCR and downstaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segregation behavior and phase instability of Eurofer97 after neutron irradiation to 72 dpa

Here, a reduced activation ferritic/martensitic steel, Eurofer97, was neutron irradiated in the vicinity of 300 °C in the High Flux Isotope Reactor (HFIR) up to 72 dpa. Advanced analytical scanning transmission electron microscopy and conventional transmission electron microscopy were applied to investigate the radiation-induced segregation and phase instability behavior after neutron irradiation. Amorphization was observed in M 23 C 6 carbides. Cr-rich clusters were seen within the matrix, near the lath boundaries and close to the M 23 C 6 carbides. Cr enrichment and Fe depletion were detected at both prior austenite grain boundaries and lath boundaries, despite different segregation magnitude. In addition, the enrichment of Ni, the depletion of V, and tiny cavities (presumably helium bubbles) are also found at lath boundaries. This work interrogates the evolution of microstructures after neutron irradiation, which provides detailed understanding on the microstructural aspects controlling the mechanical integrity of Eurofer97 under high-dose neutron damage.

36 MATERIALS SCIENCE↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Automatic CT simulation optimization for radiation therapy: A general strategy

Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43–58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. Conclusions: A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel culture morphology resulting from applied mechanical strain

To demonstrate that cells both perceive and respond to external force, a strain/relaxation regimen was applied to normal human fetal and aged dermal fibroblasts cultured as monolayers on flexible membranes. The precisely controlled protocol of stretch (20% elongation of the culture membrane) at 6.67 cycles/min caused a progressive change in the monolayers, such that the original randomly distributed pattern of cells became a symmetric, radial distribution as the cell bodies aligned parallel to the applied force. High cell density interfered with the success of re-alignment in the fetal cell cultures observed, which may reflect a preference in this cell strain for cell-cell over cell-matrix contacts. The chronologically aged cells observed did not demonstrate this feature, aligning efficiently at all seeding densities examined. The role of microfilaments in force perception and transmission was investigated through the addition of cytochalasin D in graded doses. Both intercellular interactions and cytoskeletal integrity mediate the morphological response to mechanical strain.

NASA Discipline Cell Biology↗

Development of Graphical User Interface for ARRBOD (Acute Radiation Risk and BRYNTRN Organ Dose Projection)

The space radiation environment, particularly solar particle events (SPEs), poses the risk of acute radiation sickness (ARS) to humans; and organ doses from SPE exposure may reach critical levels during extra vehicular activities (EVAs) or within lightly shielded spacecraft. NASA has developed an organ dose projection model using the BRYNTRN with SUMDOSE computer codes, and a probabilistic model of Acute Radiation Risk (ARR). The codes BRYNTRN and SUMDOSE, written in FORTRAN, are a Baryon transport code and an output data processing code, respectively. The ARR code is written in C. The risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. BRYNTRN code operation requires extensive input preparation. With a graphical user interface (GUI) to handle input and output for BRYNTRN, the response models can be connected easily and correctly to BRYNTRN in friendly way. A GUI for the Acute Radiation Risk and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations, which are required for operations of the ARRBOD modules: BRYNTRN, SUMDOSE, and the ARR probabilistic response model. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. The ARRBOD GUI will serve as a proof-of-concept example for future integration of other human space applications risk projection models. The current version of the ARRBOD GUI is a new self-contained product and will have follow-on versions, as options are added: 1) human geometries of MAX/FAX in addition to CAM/CAF; 2) shielding distributions for spacecraft, Mars surface and atmosphere; 3) various space environmental and biophysical models; and 4) other response models to be connected to the BRYNTRN. The major components of the overall system, the subsystem interconnections, and external interfaces are described in this report; and the ARRBOD GUI product is explained step by step in order to serve as a tutorial.

Kim, Myung-Hee↗

Epidermal Homeostasis and Radiation Responses in a Multiscale Tissue Modeling Framework

The surface of skin is lined with several thin layers of epithelial cells that are maintained throughout life time by a small population of stem cells. High dose radiation exposures could injure and deplete the underlying proliferative cells and induce cutaneous radiation syndrome. In this work we propose a multiscale computational model for skin epidermal dynamics that links phenomena occurring at the subcellular, cellular, and tissue levels of organization, to simulate the experimental data of the radiation response of swine epidermis, which is closely similar to human epidermis. Incorporating experimentally measured histological and cell kinetic parameters, we obtain results of population kinetics and proliferation indexes comparable to observations in unirradiated and acutely irradiated swine experiments. At the sub-cellular level, several recently published Wnt signaling controlled cell-cycle models are applied and the roles of key components and parameters are analyzed. Based on our simulation results, we demonstrate that a moderate increase of proliferation rate for the survival proliferative cells is sufficient to fully repopulate the area denuded by high dose radiation, as long as the integrity of underlying basement membrane is maintained. Our work highlights the importance of considering proliferation kinetics as well as the spatial organization of tissues when conducting in vivo investigations of radiation responses. This integrated model allow us to test the validity of several basic biological rules at the cellular level and sub-cellular mechanisms by qualitatively comparing simulation results with published research, and enhance our understanding of the pathophysiological effects of ionizing radiation on skin.

Hu, Shaowen↗

Localized Triple Modular Redundancy vs. Distributed Triple Modular Redundancy on a ProASIC3E Reprogrammable FPGA

Field programmable gate arrays (FPGA) are used in every space application. Currently, most space flight applications use radiation hardened (RH) FPGAs, which are very expensive. There is a desire to use cheaper, commercial off the shelf reprogrammable FPGAs, which are more susceptible to radiation effects known as single-event effects (SEE). The RH parts have SEE and total ionizing dose (TID) hardened elements pre-integrated into the part. This means that the designer does not need to implement any hardening techniques while configuring the device. The COTS parts on the other hand must be mitigated by design in order to insure any form of mitigation. The design techniques this project examines concern the use of localized triple modular redundancy (LTMR) and distributed triple modular redundancy (DTMR). LTMR triples every flip flop in the device architecture while DTMR triples everything except for the global routes (clocks, resets, and enables). The testing was performed on a ProASIC3E FPGA at the Texas A&M cyclotron facility. Two design architectures were used: shift registers and counters, both with LTMR and DTMR mitigation techniques. The test results prove that DTMR is more effective at reducing SEE than LTMR. We also determined that there was not a significant difference between the use of shift registers and counters for test purposes. More testing is required to obtain additional linear energy transfer values for each architecture and mitigation technique in order to determine the most cost-effective method of SEE mitigation.

McGuffey, Alex↗

Optimization of Occupancy Based Demand Controlled Ventilation in Residences

Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stability of SiC-Matrix Microencapsulated Fuel Constituents at Relevant LWR Conditions

This paper addresses certain key feasibility issues facing the application of SiC-matrix microencapsulated fuels for light water reactor application. Issues addressed are the irradiation stability of the SiC-based nano-powder ceramic matrix under LWR-relevant irradiation conditions, the presence or extent of reaction of the SiC matrix with zirconium-based cladding, the stability of the inner and outer pyrolytic graphite layers of the microencapsulated (TRISO) particle at this uncharacteristically low irradiation temperature, and the state of the particle-matrix interface following irradiation which could possibly effect thermal transport. In the process of determining these feasibility issues microstructural evolution and change in dimension and thermal conductivity was studied. As a general finding the SiC matrix was found to be quite stable with behavior similar to that of CVD SiC. In magnitude the irradiation-induced swelling of the matrix material was slightly higher and irradiation-degraded thermal conductivity was slightly lower as compared to CVD SiC. No significant reaction of this SiC-based nano-powder ceramic matrix material with Zircaloy was observed. Irradiation of the TRISO in the 320-360 C range to a maximum dose of 7.7 1025 n/m2 (E > 0.1 MeV) did not have significant negative impact on the constituent layers of the TRISO fuel. At the highest dose studied layer structure and interface integrity remained essentially unchanged with good apparent thermal transport through the microsphere to the surrounding matrix.

nuclear fuel↗

Remote Technology for Facility Deactivation and Decommissioning at the Oak Ridge National Laboratory

The facilities at the Oak Ridge National Laboratory (ORNL) that will undergo deactivation and decommissioning (D and D) over the next several years include highly contaminated hot cell facilities, reactor facilities, process facilities, and a variety of other buildings. The D and D effort will require physical, chemical, and radiological characterization as well as decontamination, material sorting, size reduction, dismantlement, and waste removal and packaging. D and D planning for ORNL facilities includes recognizing that a significant number of the facilities contain hazards that prevent the use of safe manual D and D techniques. These hazards include seriously deteriorated structural integrity as well as very high dose rates (some in the hundreds of R/hr). The hazards also include high levels of fixed and removable radioactive contamination on facility surfaces and in equipment as well as chemically hazardous materials. Thus, manned entry may be highly restricted. In these situations, remotely operated technologies will be required to complete the necessary D and D activities, minimize dose and protect workers. To prepare to use remote technologies, it is first necessary to understand the tasks typically required to complete D and D of these facilities as well as the availability, applicability, and sustainability of previously deployed remote technologies. Technologies of specific interest included remote inspection, characterization, decontamination, and dismantlement. The Applied Research Center (ARC) at Florida International University (FIU), in partnership with NuVision Engineering (NVE, formerly AEA Technology), assessed the requirements for remotely operated technologies to support D and D at ORNL. FIU-ARC and NVE then identified existing technologies that can meet the expected requirements and performed a gap analysis between the D and D needs and currently available technologies. (authors)

42 ENGINEERING↗