Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INFRARED SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Influence of Charge Block Length on Conformation and Solution Behavior of Polyampholytes

In this paper, we investigate the effect of charge block length on polyampholyte chain conformation and phase behavior using small-angle X-ray scattering (SAXS) and implicit-solvent molecular simulations. To this end, we use solid phase peptide synthesis to precision-tailor a series of polyampholytes consisting of l-glutamic acid (E) and l-lysine (K) monomers arranged in alternating blocks from 2 to 16 monomers. We observe that the polyampholytes tend to phase separate as block size increases. With addition of NaCl, phase separated polyampholytes exhibit a salting-in effect dependent on charge block length. Fourier-transform infrared (FTIR) spectroscopy reveals the presence of intramolecular hydrogen bonds that are disrupted upon the addition of NaCl, implicating both electrostatic interactions and hydrogen bonding in the phase behavior. SAXS spectra at no-added salt conditions show minimal dependence of charge block length on the radius of gyration (R g ) for soluble polyampholytes, but local chain stiffening is found to be dependent on charge block length. With increasing NaCl, consistent with electrostatic screening, all polyampholytes expand and behave as neutral or swollen chains in good solvent conditions. Molecular simulations are qualitatively consistent with experiments. Implications for understanding intracellular condensates and material design are noted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution optical micro-spectroscopy extending from the near-infrared to the vacuum-ultraviolet

Optical characterization of small samples over a wide spectral range with rapid data acquisition is essential for the analysis of many material systems, such as 2D van der Waals layers and their heterostructures. In this paper, we present the design and implementation of a tabletop micro-spectroscopy system covering the near-infrared to the vacuum-ultraviolet (1.2 eV–6.8 eV or ~1.0 μm to 185 nm) using mostly off-the-shelf components. It can measure highly reproducible local reflectance spectra with a total integration time of a few minutes and a full-width-half-maximum spot size of 2.7 by 5.6 μm. For precise positioning, the design also allows simultaneous monitoring of the measurement location and the wide-field image of the sample. We demonstrate ultra-broadband reflectance spectra of exfoliated thin flakes of several wide-gap 2D materials, including ZnPS 3 , hexagonal BN, and Ca(OH) 2 .

47 OTHER INSTRUMENTATION↗

Helium droplet infrared spectroscopy of the butyl radicals

Butyl radicals (n-, s-, i-, and tert-butyl) are formed from the pyrolysis of stable precursors (1-pentyl nitrite, 2-methyl-1-butyl nitrite, isopentyl nitrite, and azo-tert-butane, respectively). The radicals are doped into a beam of liquid helium droplets and probed with infrared action spectroscopy from 2700 to 3125 cm -1 , allowing for a low temperature measurement of the CH stretching region. The presence of anharmonic resonance polyads in the 2800–3000 cm -1 region complicates its interpretation. To facilitate spectral assignment, the anharmonic resonances are modeled with two model Hamiltonian approaches that explicitly couple CH stretch fundamentals to HCH bend overtones and combinations: a VPT2+K normal mode model based on coupled-cluster with single, double, and perturbative triple excitations [CCSD(T)] quartic force fields and a semi-empirical local mode model. Both of these computational methods provide generally good agreement with the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How long can luminous blue variables sleep? A long-term photometric variability and spectral study of the Galactic candidate luminous blue variable MN 112

ABSTRACT Luminous blue variables (LBVs) are massive stars that show strong spectral and photometric variability. The questions of what evolutionary stages they represent and what exactly drives their instability are still open, and thus it is important to understand whether LBVs without significant ongoing activity exist, and for how long such dormant LBVs may ‘sleep’. In this paper we investigate the long-term variability properties of the LBV candidate MN 112, by combining its optical and infrared spectral data covering 12 years with photometric data covering nearly a century, as acquired from both modern time-domain sky surveys and historical photographic plates. We analyse the spectra, derive the physical properties of the star by modelling its atmosphere, and use a new distance estimate from Gaia data release 3 (DR3) to determine the position of MN 112 both inside the Galaxy and in the Hertzsprung–Russell diagram. The distance estimation has almost doubled in comparison with Gaia DR2. Because of this, MN 112 moved to upper part of the diagram, and according to our modelling it lies on an evolutionary track for a star with initial mass $M_*=70~\rm M_\odot$ near the Humphreys–Davidson limit. Given the absence of any significant variability, we conclude that the star is a dormant LBV that has now been inactive for at least a century.

Maryeva, O. V. (ORCID:0000000314424755)↗

Probing vibronic coherence in charge migration in molecules using strong-field sequential double ionization

We propose a scheme for probing vibronic coherence in charge migration in molecules utilizing strong-field sequential double ionization. To demonstrate the feasibility of this approach, we perform full simulations of a pump-probe scheme employing few-cycle intense infrared pulses for N 2 and O 2 . We predict that the vibronic coherence between the pumped states will be directly imprinted in experimental observables such as kinetic energy release spectra and branching ratios of the dissociative dications. Our simulations are based on the recently developed density matrix approach for sequential double ionization model, which is capable of efficiently accounting for molecular orientations and enabling direct comparison with experimental results. Lastly, our findings strongly encourage the use of this probing scheme in future charge migration experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Simons Observatory: Combining cross-spectral foreground cleaning with multitracer B -mode delensing for improved constraints on inflation

The Simons Observatory (SO), due to start full science operations in early 2025, aims to set tight constraints on inflationary physics by inferring the tensor-to-scalar ratio r from measurements of cosmic microwave background (CMB) polarization B-modes. Its nominal design including three small-aperture telescopes (SATs) targets a precision σ⁡(r = 0) ≤ 0.003 without delensing. Achieving this goal and further reducing uncertainties requires a thorough understanding and mitigation of other large-scale B-mode sources such as Galactic foregrounds and weak gravitational lensing. We present an analysis pipeline aiming to estimate r by including delensing within a cross-spectral likelihood, and demonstrate it for the first time on SO-like simulations accounting for various levels of foreground complexity, inhomogeneous noise and partial sky coverage. As introduced in an earlier SO delensing paper, lensing B-modes are synthesized using internal CMB lensing reconstructions as well as Planck-like cosmic infrared background maps and LSST-like galaxy density maps. We then extend SO’s power-spectrum-based foreground-cleaning algorithm to include all auto- and cross-spectra between the lensing template and the SAT B-modes in the likelihood function. This allows us to constrain r and the parameters of our foreground model simultaneously. Within this framework, we demonstrate the equivalence of map-based and cross-spectral delensing and use it to motivate an optimized pixel-weighting scheme for power spectrum estimation. We start by validating our pipeline in the simplistic case of uniform foreground spectral energy distributions. In the absence of primordial B-modes, we find that the 1⁢σ statistical uncertainty on r, σ⁡(r), decreases by 37% as a result of delensing. Tensor modes at the level of r = 0.01 are successfully detected by our pipeline. Even when using more realistic foreground models including spatial variations in the dust and synchrotron spectral properties, we obtain unbiased estimates of r both with and without delensing by employing the moment-expansion method. In this case, uncertainties are increased due to the higher number of model parameters, and delensing-related improvements range between 27% and 31%. These results constitute the first realistic assessment of the delensing performance at SO’s nominal sensitivity level.

79 ASTRONOMY AND ASTROPHYSICS↗

The Urban Observatory: A Multi-Modal Imaging Platform for the Study of Dynamics in Complex Urban Systems

We describe an “Urban Observatory” facility designed for the study of complex urban systems via persistent, synoptic, and granular imaging of dynamical processes in cities. An initial deployment of the facility has been demonstrated in New York City and consists of a suite of imaging systems—both broadband and hyperspectral—sensitive to wavelengths from the visible (∼400 nm) to the infrared (∼13 micron) operating at cadences of ∼0.01–30 Hz (characteristically ∼0.1 Hz). Much like an astronomical survey, the facility generates a large imaging catalog from which we have extracted observables (e.g., time-dependent brightnesses, spectra, temperatures, chemical species, etc.), collecting them in a parallel source catalog. We have demonstrated that, in addition to the urban science of cities as systems, these data are applicable to a myriad of domain-specific scientific inquiries related to urban functioning including energy consumption and end use, environmental impacts of cities, and patterns of life and public health. We show that an Urban Observatory facility of this type has the potential to improve both a city’s operations and the quality of life of its inhabitants.

54 ENVIRONMENTAL SCIENCES↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

Neural Density Estimation and Uncertainty Quantification for ChemCam Spectra [Slides]

The ChemCam instrument of Curiosity uses laser-induced breakdown spectroscopy (LIBS). It fires a laser at target and vaporizes rock surfaces, creating a plasma. Three spectrographs divide the plasma light into wavelengths for chemical analysis: ultraviolet, violet, and visible near-infrared. Regression methods (SVR, PCR, CNN) have been employed for calibration (prediction of the elemental composition of samples); however, labeled ChemCam samples are limited. Here, we focus on unsupervised learning and employ generative models from ChemCam analysis. Further, we use labels (supervised) in combination to the generative model to compute uncertainties related to predictions. We report generative modeling can be successfully applied to model real-world data. Normalizing flow models can be efficiently constructed on latent spaces for fast downstream inference. Unsupervised and supervised learning can be combined to form an uncertainty quantification framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic rays in molecular clouds probed by H 2 rovibrational lines

Context. Low-energy cosmic rays (<1 TeV) play a fundamental role in the chemical and dynamical evolution of molecular clouds, as they control the ionisation, dissociation, and excitation of H 2 . Their characterisation is therefore important both for the interpretation of observations and for the development of theoretical models. However, the methods used so far for estimating the cosmic-ray ionisation rate in molecular clouds have several limitations due to uncertainties in the adopted chemical networks. Aims. Here, we refine and extend a previously proposed method to estimate the cosmic-ray ionisation rate in molecular clouds by observing rovibrational transitions of H 2 at near-infrared wavelengths, which are mainly excited by secondary cosmic-ray electrons. Methods. Combining models of interstellar cosmic-ray propagation and attenuation in molecular clouds with the rigorous calculation of the expected secondary electron spectrum and updated electron-H 2 excitation cross sections, we derive the intensity of the four H 2 rovibrational transitions observable in cold dense gas: (1—0)O(2), (1—0)Q(2), (1—0)S(0), and (1—0)O(4). Results. The proposed method allows the estimation of the cosmic-ray ionisation rate for a given observed line intensity and H 2 column density. We are also able to deduce the shape of the low-energy cosmic-ray proton spectrum impinging upon the molecular cloud. In addition, we present a look-up plot and a web-based application that can be used to constrain the low-energy spectral slope of the interstellar cosmic-ray proton spectrum. We finally comment on the capability of the James Webb Space Telescope to detect these near-infrared H 2 lines, which will make it possible to derive, for the first time, spatial variation in the cosmic-ray ionisation rate in dense gas. Besides the implications for the interpretation of the chemical-dynamic evolution of a molecular cloud, it will finally be possible to test competing models of cosmic-ray propagation and attenuation in the interstellar medium, as well as compare cosmic-ray spectra in different Galactic regions

79 ASTRONOMY AND ASTROPHYSICS↗

Geochemistry of Mars with Laser-Induced Breakdown Spectroscopy (LIBS): ChemCam, SuperCam, and MarSCoDe

Laser-induced breakdown spectroscopy (LIBS) has been used to explore the chemistry of three regions of Mars on respective missions by NASA and CNSA, with CNES contributions. All three LIBS instruments use ~100 mm diameter telescopes projecting pulsed infrared laser beams of 10–14 mJ to enable LIBS at 2–10 m distances, eliminating the need to position the rover and instrument directly onto targets. Over 1.3 million LIBS spectra have been used to provide routine compositions for eight major elements and several minor and trace elements on >3000 targets on Mars. Onboard calibration targets common to all three instruments allow careful intercomparison of results. Operating over thirteen years, ChemCam on Curiosity has explored lacustrine sediments and diagenetic features in Gale crater, which was a long-lasting (>1 My) lake during Mars’ Hesperian period. SuperCam on Perseverance is exploring the ultramafic igneous floor, fluvial–deltaic features, and the rim of Jezero crater. MarSCoDe on the Zhurong rover investigated for one year the local blocks, soils, and transverse aeolian ridges of Utopia Planitia. The pioneering work of these three stand-off LIBS instruments paves the way for future space exploration with LIBS, where advantages of light-element (H, C, N, O) quantification can be used on icy regions.

47 OTHER INSTRUMENTATION↗

Resolving the Impact of Hydrogen Bonding on the Phylloquinone Cofactor through Two-Dimensional Infrared Spectroscopy

Phylloquinone (PhQ) is a molecule involved in photosynthetic electron transfer, where the local protein environment is known to tune the properties of PhQ through various noncovalent interactions. In this work, we determine how hydrogen bonding, one of these noncovalent interactions, alters the vibrational potential energy surface of PhQ. In addition, this work demonstrates how hydrogen bonding to PhQ manifests in ultrafast multidimensional vibrational spectra, which is an important step towards using ultrafast vibrational based spectroscopies to probe PhQ embedded in the binding pocket of photosynthetic reaction centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Probing electrolyte–silica interactions through simulations of the infrared spectroscopy of nanoscale pores

The structural and dynamical properties of nanoconfined solutions can differ dramatically from those of the corresponding bulk systems. Understanding the changes induced by confinement is central to controlling the behavior of synthetic nanostructured materials and predicting the characteristics of biological and geochemical systems. A key outstanding issue is how the molecular-level behavior of nanoconfined electrolyte solutions is reflected in different experimental, particularly spectroscopic, measurements. This is addressed here through molecular dynamics simulations of the OH stretching infrared (IR) spectroscopy of NaCl, NaBr, and NaI solutions in isotopically dilute HOD/D 2 O confined in hydroxylated amorphous silica slit pores of width 1–6 nm and pH ~2. In addition, the water reorientation dynamics and spectral diffusion, accessible by pump–probe anisotropy and two-dimensional IR measurements, are investigated. In this work, the aim is to elucidate the effect of salt identity, confinement, and salt concentration on the vibrational spectra. It is found that the IR spectra of the electrolyte solutions are only modestly blue-shifted upon confinement in amorphous silica slit pores, with both the size of the shift and linewidth increasing with the halide size, but these effects are suppressed as the salt concentration is increased. This indicates the limitations of linear IR spectroscopy as a probe of confined water. However, the OH reorientational and spectral diffusion dynamics are significantly slowed by confinement even at the lowest concentrations. The retardation of the dynamics eases with increasing salt concentration and pore width, but it exhibits a more complex behavior as a function of halide.

Mesoporous material↗

Characterization of single-shot attosecond pulses with angular streaking photoelectron spectra

Most of the traditional attosecond pulse retrieval algorithms are based on a so-called attosecond streak camera technique, in which the momentum of the electron is shifted by an amount depending on the relative time delay between the attosecond pulse and the streaking infrared pulse. Thus, temporal information of the attosecond pulse is encoded in the amount of momentum shift in the streaked photoelectron momentum spectrogram S(p,τ), where p is the momentum of the electron along the polarization direction and τ is the time delay. An iterative algorithm is then employed to reconstruct the attosecond pulse from the streaking spectrogram. This method, however, cannot be applied to attosecond pulses generated from free-electron x-ray lasers where each single shot is different and stochastic in time. However, using a circularly polarized infrared laser as the streaking field, a two (or three)-dimensional angular streaking electron spectrum can be used to retrieve attosecond pulses for each shot, as well as the time delay with respect to the circularly polarized IR field. Here we show that a retrieval algorithm previously developed for the traditional streaking spectrogram can be modified to efficiently characterize single-shot attosecond pulses. The methods have been applied to retrieve 188 single shots from recent experiments. We analyze the statistical behavior of these 188 pulses in terms of pulse duration, bandwidth, pulse peak energy, and time delay with respect to the IR field. Furthermore, the retrieval algorithm is efficient and can be easily used to characterize a large number of shots in future experiments for attosecond pulses at free-electron x-ray laser facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

The use of double-mode RR Lyrae stars as robust distance and metallicity indicators

Abstract RR Lyrae stars are one of the primary distance indicators for old stellar populations such as globular clusters, dwarf galaxies and galaxies. Typically, fundamental-mode RR Lyr stars are used for distance measurements, and their accuracy is strongly limited by the dependence of absolute magnitudes on metallicity, in both the optical and infrared bands. Here, we report the discovery of a period–(period ratio)–metallicity relation for double-mode RR Lyr stars, which can predict metallicity as accurately as the low-resolution spectra. With theoretical and observational evidence, we propose that the period–luminosity relation of double-mode RR Lyr stars is not affected by the metallicity. Combining the Large Magellanic Cloud distance and Gaia parallaxes, we calibrate the zero point of the period–luminosity relation to an error of 0.022 mag, which means that in the best case double-mode RR Lyr stars can anchor galaxy distances to an accuracy of 1.0%. For four globular clusters and two dwarf galaxies, we obtain distances using double-mode RR Lyr stars with a distance accuracy of 2–3% and 1–2%, respectively. With future telescopes such as the China Space Station Telescope and the Vera C. Rubin Observatory, double-mode RR Lyr stars will be established as an independent distance ladder in the near-field universe.

Astronomy & Astrophysics↗

Simons Observatory: Constraining inflationary gravitational waves with multitracer B-mode delensing

We introduce and validate a delensing framework for the Simons Observatory (SO), which will be used to improve constraints on inflationary gravitational waves by reducing the lensing noise in measurements of the B modes in CMB polarization. SO will initially observe CMB by using three small aperture telescopes and one large-aperture telescope. While polarization maps from small-aperture telescopes will be used to constrain inflationary gravitational waves, the internal CMB lensing maps used to delens will be reconstructed from data from the large-aperture telescope. Since lensing maps obtained from the SO data will be noise dominated on subdegree scales, the SO lensing framework constructs a template for lensing-induced B modes by combining internal CMB lensing maps with maps of the cosmic infrared background from Planck as well as galaxy density maps from the LSST survey. We construct a likelihood for constraining the tensor-to-scalar ratio r that contains auto and cross spectra between observed B modes and the lensing B-mode template. We test our delensing analysis pipeline on map-based simulations containing survey nonidealities, but that, for this initial exploration, does not include contamination from Galactic and extragalactic foregrounds. We find that the SO survey masking and inhomogeneous and atmospheric noise have very little impact on the delensing performance, and the r constraint becomes σ(r)≈0.0015 which is close to that obtained from the idealized forecasts in the absence of the Galactic foreground and is nearly a factor of 2 tighter than without delensing. We also find that uncertainties in the external large-scale structure tracers used in our multitracer delensing pipeline lead to bias much smaller than the 1σ statistical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗