Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Wear measurement of highly cross-linked UHMWPE using a 7 Be tracer implantation technique

The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

Wimmer, Markus A.↗

Strain Recovery and Defect Characterization in Mg‐Implanted Homoepitaxial GaN on High‐Quality GaN Substrates

The evolution of defects due to high‐pressure annealing of magnesium ion‐implanted epitaxial GaN grown on high‐quality GaN substrates is investigated. Changes in the implant‐induced strain are quantified as a function of annealing temperature and time. After annealing at 1300 °C for 10 min, the implant‐induced strain is fully relieved and accompanied by the presence of extended defects such as basal plane stacking faults and prismatic loops. Approximately one‐third of the original implant‐induced strain remains after annealing at 700 °C, and 5% of the original strain remains at 1000 °C for 100 min. In all cases, nearly all of the recovered strain occurs within first few minutes of annealing. A prominent increase in the asymmetric (104) triple axis X‐ray rocking curve full width at 0.01 maximum (FW0.01M) is observed after annealing at 1300 °C for 10 min. After annealing at 1300 °C for 100 min, a subsequent decrease in FW0.01M is correlated with a reduction of the extended defect density from 4 × 10 8 to 3 × 10 7 cm −2 , determined through transmission electron microscope (TEM) measurements. Further reduction in the density of the extended defects by optimizing annealing temperature and time is expected to improve the performance of GaN‐based vertical power devices.

Wang, Yekan↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receive an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Endografting on the Thoracic Aortic Anatomy: Comparative Analysis of the Aortic Geometry before and after the Endograft Implantation

Purpose: Although the widespread acceptance of thoracic endovascular aortic repair (TEVAR) as a first-line treatment option for a multitude of thoracic aortic diseases, little is known about the consequences of the device implantation on the native aortic anatomy. We propose a comparative analysis of the pre- and postoperative geometry on a clinical series of patients and discuss the potential clinical implications Methods: CT pre- and postoperative acquisitions of 30 consecutive patients treated by TEVAR for different pathologies (20 thoracic aortic aneurysms, 6 false aneurysms, 3 penetrating ulcers, 1 traumatic rupture) were used to model the vascular geometry. Pre- and postoperative geometries were compared for each patient by pairing and matching the 3D models. An implantation site was identified, and focal differences were detected and described. Results: Segmentation of the data sets was successfully performed for all 30 subjects. Geometry differences between the pre- and postoperative meshes were depicted in 23 patients (76 %). Modifications at the upper implantation site were detected in 14 patients (47 %), and among them, the implantation site involved the arch (Z0–3) in 11 (78 %). Conclusion: Modeling the vascular geometry on the basis of imaging data offers an effective tool to perform patient-specific analysis of the vascular geometry before and after the treatment. Future studies will evaluate the consequences of these changes on the aortic function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Outcome of Peripherally Implanted Venous Access Ports in the Forearm in Female Cancer Patients

PurposeThe aim of this retrospective study was to analyze the long-term outcome of peripherally implanted venous access ports in the forearm at our institution in a female patient collective.MethodsBetween June 2002 and May 2011, a total of 293 female patients with an underlying malignancy had 299 forearm ports implanted in our interventional radiology suite. The mean age of the cohort was 55 ± 12 years (range 26–81 years). The majority of women suffered from breast (59.5 %) or ovarian cancer (28.1 %). Complications were classified as infectious complications, thrombotic and nonthrombotic catheter dysfunction (dislocation of the catheter or port chamber, fracture with/without embolization or kinking of the catheter, port occlusion), and others.ResultsWe analyzed a total of 90,276 catheter days in 248 port systems (47 patients were lost to follow-up). The mean device service interval was 364 days per catheter (range 8–2,132, median 223 days, CI 311–415, SD 404). Sixty-seven early (≤30 days from implantation) or late complications (>30 days) occurred during the observation period (0.74/1,000 catheter days). Common complications were port infection (0.18/1,000 days), thrombotic dysfunction (0.12/1,000 days), and skin dehiscence (0.12/1,000 days). Nonthrombotic dysfunction occurred in a total of 21 cases (0.23/1,000 days) and seemed to cumulate on the venous catheter entry site on the distal upper arm.ConclusionPeripherally implanted venous access ports in the forearm are a safe alternative to chest or upper-arm ports in female oncology patients. Special attention should be paid to signs of skin dehiscence and nonthrombotic dysfunction, especially when used for long-term treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surgical implantation techniques for electronic tags in fish

Intracoelomic implantation of transmitters into fish requires making a surgical incision, incision closure, and other surgery related techniques; however, the tools and techniques used in the surgical process vary widely. We review the available literature and focus on tools and techniques used for conducting surgery on juvenile salmonids because of the large amount of research that is conducted on them. The use of sterilized surgical instruments properly selected for a given size of fish will minimize tissue damage and infection rates, and speed the wound healing of fish implanted with transmitters. For the implantation of transmitters into small fish, the optimal surgical methods include making an incision on the ventral midline along the linea alba (for studies under 1 month), protecting the viscera (by lifting the skin with forceps while creating the incision), and using absorbable monofilament suture with a small-swaged-on swaged-on tapered or reverse-cutting needle. Standardizing the implantation techniques to be used in a study involving particular species and age classes of fish will improve survival and transmitter retention while allowing for comparisons to be made among studies and across multiple years. This review should be useful for researchers working on juvenile salmonids and other sizes and species of fish.

59 BASIC BIOLOGICAL SCIENCES↗

Improvement of field emission performance on nitrogen ion implanted ultrananocrystalline diamond films through visualization of structure modificaitons.

The relationship between the electron field emission properties and structure of ultra-nanocrystalline diamond (UNCD) films implanted by nitrogen ions or carbon ions was investigated. The electron field emission properties of nitrogen-implanted UNCD films and carbon-implanted UNCD films were pronouncedly improved with respect to those of as-grown UNCD films, that is, the turn-on field decreased from 23.2 V/{micro}m to 12.5 V/{micro}m and the electron field emission current density increased from 10E-5 mA/cm{sup 2} to 1 x 10E-2 mA/cm{sup 2}. The formation of a graphitic phase in the nitrogen-implanted UNCD films was demonstrated by Raman microscopy and cross-sectional high-resolution transmission electron microscopy. The possible mechanism is presumed to be that the nitrogen ion irradiation induces the structure modification (converting sp{sup 3}-bonded carbons into sp{sup 2}-bonded ones) in UNCD films.

74 ATOMIC AND MOLECULAR PHYSICS↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic phase composition of strontium titanate implanted with iron ions

Highlights: Black-Right-Pointing-Pointer The origin of RT-ferromagnetism in iron implanted strontium titanate. Black-Right-Pointing-Pointer Metallic iron nanoclusters form during implantation and define magnetic behaviour. Black-Right-Pointing-Pointer Paramagnetic at room temperature iron-substituted strontium titanate identified. -- Abstract: Thin magnetic films were synthesized by means of implantation of iron ions into single-crystalline (1 0 0) substrates of strontium titanate. Depth-selective conversion electron Moessbauer spectroscopy (DCEMS) indicates that origin of the samples magnetism is {alpha}-Fe nanoparticles. Iron-substituted strontium titanate was also identified but with paramagnetic behaviour at room temperature. Surface magneto-optical Kerr effect (SMOKE) confirms that the films reveal superparamagnetism (the low-fluence sample) or ferromagnetism (the high-fluence sample), and demonstrate absence of magnetic in-plane anisotropy. These findings highlight iron implanted strontium titanate as a promising candidate for composite multiferroic material and also for gas sensing applications.

36 MATERIALS SCIENCE↗

Proposed mechanism to represent the suppression of dark current density by four orders with low energy light ion (H{sup −}) implantation in quaternary alloy-capped InAs/GaAs quantum dot infrared photodetectors

Graphical abstract: - Abstract: Here we propose a carrier transport mechanism for low energy H{sup −} ions implanted InAs/GaAs quantum dot infrared photodetectors supportive of the experimental results obtained. Dark current density suppression of up to four orders was observed in the implanted quantum dot infrared photodetectors, which further demonstrates that they are effectively operational. We concentrated on determining how defect-related material and structural changes attributed to implantation helped in dark current density reduction for InAs/GaAs quantum dot infrared photodetectors. This is the first study to report the electrical carrier transport mechanism of H{sup −} ion-implanted InAs/GaAs quantum dot infrared photodetectors.

36 MATERIALS SCIENCE↗

Effects of helium implantation on the tensile properties and microstructure of Ni₇₃P₂₇ metallic glass nanostructures

We report fabrication and nanomechanical tension experiments on as-fabricated and helium-implanted ~130 nm diameter Ni₇₃P₂₇ metallic glass nano-cylinders. The nano-cylinders were fabricated by a templated electroplating process and implanted with He⁺ at energies of 50, 100, 150, and 200 keV to create a uniform helium concentration of ~3 at. % throughout the nano-cylinders. Transmission electron microscopy (TEM) imaging and through-focus analysis reveal that the specimens contained ~2 nm helium bubbles distributed uniformly throughout the nano-cylinder volume. In-situ tensile experiments indicate that helium-implanted specimens exhibit enhanced ductility as evidenced by a 2-fold increase in plastic strain over as-fabricated specimens, with no sacrifice in yield and ultimate tensile strengths. This improvement in mechanical properties suggests that metallic glasses may actually exhibit a favorable response to high levels of helium implantation.

36 MATERIALS SCIENCE↗

Designing functionality in perovskite thin films using ion implantation techniques: Assessment and insights from first-principles calculations

Ion implantation has been widely used in the semiconductor industry for decades to selectively control electron/hole doping for device applications. Recently, experimental studies on ion implantation into more structurally and electronically complex materials have been undertaken in which defect generation has been used to control a variety of functional phenomena. Of particular interest, are recent findings demonstrating that low doses of low energy helium ions into single crystal films can be used to tailor the structural properties. These initial experimental studies have shown that crystal symmetry can be continuously controlled by applying increasingly large doses of He ions into a crystal. The observed changes in lattice structure were then observed to correlate with functional changes, such as metal-insulator transition temperature2 and optical bandgap3. In these preliminary experimental studies, changes to lattice expansion was proposed to be the direct result of chemical pressure originating predominantly from the implanted He applying chemical pressure at interstitial sites. However, the influence of possible secondary knock-on damage arising from the He atoms transferring energy to the lattice through nuclear-nuclear collision with the crystal lattice remains largely unaddressed. In this work, we focus on a SrRuO3 model system to provide a comprehensive examination of the impact of common defects on structural and electronic properties, obtain calculated defect formation energies, and define defect migration barriers. Our model indicates that, while interstitial He can modify the crystal properties, a dose significantly larger than those reported in experimental studies would be required. The true origin of the observed structural changes is likely the result of a combination of secondary defects created during He implantation. Of particular importance, we observe that different defect types can generate greatly varied local electronic structures and that the formation energies and migration energy barriers vary by defect type. Thus, we may have identified a new method of selectively inducing controlled defect complexes into single crystal materials. Development of this approach would have a broad impact on both our ability to probe specific defect contributions in fundamental studies and allow a new level of control over functional properties driven by specific defect complexes.

36 MATERIALS SCIENCE↗

Arrays of Si vacancies in 4 H -SiC produced by focused Li ion beam implantation

Point defects in SiC are an attractive platform for quantum information and sensing applications because they provide relatively long spin coherence times, optical spin initialization, and spin-dependent fluorescence readout in a fabrication-friendly semiconductor. The ability to precisely place these defects at the optimal location in a host material with nano-scale accuracy is desirable for integration of these quantum systems with traditional electronic and photonic structures. Here, we demonstrate the precise spatial patterning of arrays of silicon vacancy (${V}_{Si}$) emitters in an epitaxial 4H -SiC (0001) layer through mask-less focused ion beam implantation of Li + . We characterize these arrays with high-resolution scanning confocal fluorescence microscopy on the Si-face, observing sharp emission lines primarily coming from the ${V1}^{{\prime}}$ zero-phonon line (ZPL). The implantation dose is varied over 3 orders of magnitude, leading to ${V}_{Si}$ densities from a few per implantation spot to thousands per spot, with a linear dependence between ZPL emission and implantation dose. Optically-detected magnetic resonance (ODMR) is also performed, confirming the presence of V2 ${V}_{Si}$. Our investigation reveals scalable and reproducible defect generation.

36 MATERIALS SCIENCE↗

Histological response of soda-lime glass-ceramic bactericidal rods implanted in the jaws of beagle dogs

Bacterial and fungal infections remain a major clinical challenge. Implant infections very often require complicated revision procedures that are troublesome to patients and costly to the healthcare system. Innovative approaches to tackle infections are urgently needed. We investigated the histological response of novel free P 2 O 5 glass-ceramic rods implanted in the jaws of beagle dogs. Due to the particular percolated morphology of this glass-ceramic, the dissolution of the rods in the animal body environment and the immature bone formation during the fourth months of implantation maintained the integrity of the glass-ceramic rod. No clinical signs of inflammation took place in any of the beagle dogs during the four months of implantation. This new glass-ceramic biomaterial with inherent bactericidal and fungicidal properties can be considered as an appealing candidate for bone tissue engineering.

60 APPLIED LIFE SCIENCES↗

Domain state exchange bias in a single layer FeRh thin film formed via low energy ion implantation

Modern spintronics relies heavily on the exchange bias effect to pin the orientation of ferromagnetic layers in magnetic tunnel junctions. The current implementations of exchange bias in magnetic tunnel junctions employ pristine interfaces between antiferromagnetic and ferromagnetic layers. Here we reveal an interfacial exchange bias introduced by a single-step, low-energy ion implantation process in a single layer FeRh thin film. Both 1 keV He + ions and 5 keV Fe + were investigated, their energy selected to ensure the ions would stop within the FeRh film. The ions reduce the metamagnetic transition temperature through defect generation to form a surface layer with ferromagnetic ordering. Temperature dependent magnetism measurements reveal a room temperature exchange bias between the ferromagnetic surface and the antiferromagnetic bulk of ~41 Oe in 5 keV Fe + implanted samples and ~36 Oe for 1 keV He + implanted samples. We directly scrutinize this exchange bias effect in magnetic depth profiles obtained by polarized neutron reflectometry which clearly show a pinned ferromagnetic layer adjacent to the disordered layer created by low energy Fe + ion implantation. These results reveal a novel method to implement exchange bias in an antiferromagnetic layer that can have direct application in the field of spintronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Diffraction Spectra in Cu-Implanted SiO{sub 2} Films on Si(100) Substrates

Cu-implanted SiO{sub 2} films on Si(100) have been studied using x-ray methods and x-ray diffraction pattern processing. The x-ray results indicate the presence of a preferred orientation for Cu {l_brace}111{r_brace} planes parallel to the substrate surface without directional orientation for Cu-implanted SiO{sub 2}/Si(100) and nano-crystalline-Cu/SiO{sub 2}/Si(100)(ie. after implanted and annealed Cu). The x-ray diffraction spectra of the Cu-implanted and nano-crystalline-Cu phases were analyzed (ie. in terms of peak search, profile fit, crystallite size) and compared to data from complimentary techniques (RBS, TEM). Results are discussed with respect to x-ray spectral lines shapes derived from XRD spectra processing and the nanostructure problem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isolation blocking voltage of nitrogen ion-implanted AlGaN/GaN high electron mobility transistor structure

Nitrogen ion-implanted AlGaN/GaN high electron mobility transistor structures showed an isolation blocking voltage of 900 V with a leakage current at 1 A/mm across an implanted isolation-gap of 10 m between two Ohmic pads. The effect of implanted gap distance 1.7, 5, or 10 m between two Ohmic contact pads was evaluated. The isolation current density was determined to be solely dependent on the applied field between the contact pads. A model using a combination of resistive current and Poole Frenkel current is consistent with the experimental data. The resistance of the isolation implantation region significantly decreased after the sample was annealed at temperatures above 600 C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗