Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Genetic Variants in CD44 and MAT1A Confer Susceptibility to Acute Skin Reaction in Breast Cancer Patients Undergoing Radiation Therapy

Purpose: Heterogeneity in radiation therapy (RT)-induced normal tissue toxicity is observed in 10% of cancer patients, limiting the therapeutic outcomes. In addition to treatment-related factors, normal tissue adverse reactions also manifest from genetic alterations in distinct pathways majorly involving DNA damage–repair genes, inflammatory cytokine genes, cell cycle regulation, and antioxidant response. Therefore, the common sequence variants in these radioresponsive genes might modify the severity of normal tissue toxicity, and the identification of the same could have clinical relevance as a predictive biomarker. Methods and Materials: The present study was conducted in a cohort of patients with breast cancer to evaluate the possible associations between genetic variants in radioresponsive genes described previously and the risk of developing RT-induced acute skin adverse reactions. We tested 22 genetic variants reported in 18 genes (ie, NFE2L2, OGG1, NEIL3, RAD17, PTTG1, REV3L, ALAD, CD44, RAD9A, TGFβR3, MAD2L2, MAP3K7, MAT1A, RPS6KB2, ZNF830, SH3GL1, BAX, and XRCC1) using TaqMan assay-based real-time polymerase chain reaction. At the end of RT, the severity of skin damage was scored, and the subjects were dichotomized as nonoverresponders (Radiation Therapy Oncology Group grade <2) and overresponders (Radiation Therapy Oncology Group grade ≥2) for analysis. Results: Of the 22 single nucleotide polymorphisms studied, the rs8193 polymorphism lying in the micro-RNA binding site of 3′-UTR of CD44 was significantly (P=.0270) associated with RT-induced adverse skin reactions. Generalized multifactor dimensionality reduction analysis showed significant (P=.0107) gene–gene interactions between MAT1A and CD44. Furthermore, an increase in the total number of risk alleles was associated with increasing occurrence of overresponses (P=.0302). Conclusions: The genetic polymorphisms in radioresponsive genes act as genetic modifiers of acute normal tissue toxicity outcomes after RT by acting individually (rs8193), by gene–gene interactions (MAT1A and CD44), and/or by the additive effects of risk alleles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exosomes and Exosomal MicroRNAs in Prostate Cancer Radiation Therapy

Despite current risk stratification systems using traditional clinicopathologic factors, many localized and locally advanced prostate cancers fail radical treatment (ie, radical prostatectomy, radiation therapy with or without androgen deprivation therapy). Therefore, a pressing need exists for enhanced methods of disease stratification through novel prognostic and predictive tools that can reliably be applied in clinical practice. Exosomes are 50- to 150-nm small vesicles released by cancer cells that reflect the genetic and nongenetic materials of parent cancer cells. Cancer cells can contain distinct sets of microRNA profiles, the expression of which can change owing to stress such as radiation therapy. These alterations or distinctions in contents allow exosomes to be used as prognostic and/or predictive biomarkers and to monitor the treatment response. Additionally, microRNAs have been shown to influence multiple processes in prostate tumorigenesis, including cell proliferation, induction of apoptosis, migration, oncogene inhibition, and radioresistance. Thus, comparative exosomal microRNA profiling at different levels could help portray tumor aggressiveness and response to radiation therapy. Although technical challenges persist in exosome isolation and characterization, recent improvements in microRNA profiling have evolved toward in-depth analyses of the exosomal cargo and its functions. We have reviewed the role of exosomes and exosomal microRNAs in biologic processes of prostate cancer progression and radiation therapy response, with a particular focus on the development of clinical assays for treatment personalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiomic Biomarkers to Refine Risk Models for Distant Metastasis in HPV-related Oropharyngeal Carcinoma

Distant metastasis (DM) is the main cause of death for patients with human papillomavirus (HPV)–related oropharyngeal cancers (OPCs); yet, there are few reliable predictors of DM in this disease. The role of quantitative imaging (ie, radiomic) analysis was examined to determine whether there are primary tumor features discernible on imaging studies that are associated with a higher risk of DM developing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Education Program in Radiation Medicine: International Learner Perceptions of Experiences, Outcomes, and Impact

The Accelerated Education Program (AEP) at the Princess Margaret Cancer Centre (PM) has been offering continuing medical education courses since 2006. The purpose of this study was to assess learner experiences, perspectives, and outcomes using Kirkpatrick’s Four Level Training Evaluation Model (ie, reaction, learning, behavior, results) to ascertain whether it was meeting stated goals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deciphering Time-Dependent DNA Damage Complexity, Repair, and Oxygen Tension: A Mechanistic Model for FLASH-Dose-Rate Radiation Therapy

Irradiation with ultrahigh dose rates (FLASH) has reemerged as a promising radiation therapy approach to effectively lower potential damage burden on normal tissue without sacrificing tumor control. However, the large number of recent FLASH studies have been conducted under vastly different experimental conditions and circumstances (ie, investigated biological endpoint, radiation quality, and environmental oxygen level), with unverified biological mechanisms of action and unexplored interplay effect of the main dependencies. To facilitate radiobiological investigation of FLASH phenomena and assessment of clinical applicability, we present an extension of the mechanistic radiobiological model “UNified and VERSatile bio response Engine” (UNIVERSE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding Competing Risks

Highlights: • Clinicians and researchers need to be cognizant of competing risks (ie, the occurrence of an event that precludes future development of the outcome of interest). • Censoring is appropriate when a patient being censored at a particular time (eg, owing to loss to follow-up) is deemed to have approximately the same future risk of developing the outcome of interest as patients still being followed, and when the reason for censoring is not related to events of interest. • Censoring is not appropriate in many scenarios; for example, a dead patient can never develop a future cancer recurrence or late effect. • Kaplan-Meier (KM) analysis is commonly used for a time-to-event analysis when the primary outcome (eg, overall survival) has no meaningful competing risk and censoring is appropriate. Cox proportional hazards modeling can be used for multivariable analysis to examine the association between covariates and the primary outcome. • In the presence of competing events, incorrect use of the KM analysis will likely lead to an overestimation of the risk of the outcome of interest and biased estimates from both univariable and multivariable analyses. Therefore, KM usually should not be used to determine local recurrence risk because humanity is always at risk for dying, which is a competing risk. • A competing risk analysis is therefore most appropriate when there are competing events to the primary outcome of interest. The most commonly used multivariable model in these situations is the Fine-Gray model. • Many fundamental questions in radiation oncology—local and regional recurrence, treatment-related toxicity—are best addressed using competing risk methodologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Attention Guided Lymph Node Malignancy Prediction in Head and Neck Cancer

Accurate lymph node (LN) malignancy classification is essential for treatment target identification in head and neck cancer (HNC) radiation therapy. Given the constraints imposed by relatively small sample sizes in real-world medical applications, to classify LN malignancy status accurately, we proposed an attention-guided classification (AGC) scheme that (1) incorporates human knowledge (ie, LN contours) into model training to guide model’s “learning” direction, alleviating the critical requirement of large training samples by deep learning approaches; and (2) does not require accurate delineation of LNs in the inference stage but can highlight the discriminative region nearby the LN, which is important for malignancy determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Logistic Regression in Clinical Studies

• A logistic regression model is used when the outcome of interest is binary. The term “logistic” refers to the underlying “logit” (log odds) function that is used to model the binary outcome. • Odds ratios are produced from a logistic regression model and have a useful interpretation. • Tips, tricks and concepts used to fit logistic regression models are similar to those used in linear regression models. • Modeling building that is knowledge-based rather than automatic is preferred in most applications of logistic regression. • A logistic regression model that is overparameterized (ie, too many variables for too few events) can result in odds ratios that are implausibly large and confidence intervals that are wide and uninterpretable. These types of “overfitted” models should be avoided. • Logistic regression models can be fit using most standard statistical software.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mass-transport properties of electrosprayed Pt/C catalyst layers for polymer-electrolyte fuel cells

Mass-transport properties of electrosprayed catalyst-layers based on Pt/C and ionomer (Nafion) are investigated with hydrogen limiting-current technique, water-vapor-uptake, scanning transmission microscopy (STEM), single-cell testing, and impedance spectroscopy. The hydrogen limiting-current technique provides the transport resistance of the layers ( R CL m t ), which demonstrates to be lower in electrosprayed layers compared with conventional layers, especially at very low platinum loadings (0.025 mg Pt ·cm -2 ) and low cell temperature, denoting superior mass-transport properties. Images of the distribution of Pt, F, and C elements reveal the ionomer preferentially interacting with the Pt nanoparticles. Water-vapor-uptake experiments show larger vapor absorption for electrosprayed than conventional catalyst layers. Such large water-vapor uptake capability is combined with superhydrophobicity, ie. very low interaction with water in liquid phase (wettability). Both apparently contradictory properties result from a particular configuration of the amphiphilic ionomer in the electrosprayed layers, and provide ideal conditions for high mass transport and ionic conductivity in a catalyst layer. Electrosprayed layers as cathode catalyst layers reflect peak response at a loading of 0.17 mg Pt ·cm -2 (18 μm layer thickness when using Pt/C 20 wt% catalyst) where they provide minimal mass-transport and polarization resistances.

08 HYDROGEN↗

Syntheses and properties of a series of chromium vanadates ACrV{sub 2}O{sub 7} (A=Na, K, Rb, Cs) with layered structure

A series of layered compounds ACrV{sub 2}O{sub 7} (A=Na, K, Rb, Cs) were investigated by means of powder X-ray diffraction technique, thermal analysis and IR spectroscopy. As a new member in this family, the structure of CsCrV{sub 2}O{sub 7} is confirmed by Rietveld refinement applying powder X-ray diffraction data. Isostructural NaCrV{sub 2}O{sub 7} was obtained by ion-exchange reaction of KCrV{sub 2}O{sub 7} in NaNO{sub 3} melt under 350 Degree-Sign C and was testified to be a metastable phase. These compounds crystallize in a monoclinic structure in the space group P2/c, and consist of planar CrV{sub 2}O{sub 7}{sup -} slabs interleaved by alkali-metal cations. ACrV{sub 2}O{sub 7} (A=K, Rb, Cs) present decreasing melting points and characteristic vibration of V=O bond in IR spectra. Magnetic measurements reveal weak antiferromagnetic interactions between Cr{sup 3+} cations in the isolated chains. - Graphical Abstract: A series of layered chromium vanadates ACrV{sub 2}O{sub 7} (A=Na, K, Rb, Cs) have been synthesized by direct solid state reactions and ion-exchange routes. The interlayer alkali-metal cations were testified ion-exchangeable by some smaller monovalent cations. Highlights: Black-Right-Pointing-Pointer The entire family of ACrV{sub 2}O{sub 7} (A=Na, K, Rb, Cs) have been prepared via solid-state reactions and ion-exchange routes. Black-Right-Pointing-Pointer CsCrV{sub 2}O{sub 7} and a metastable phase of NaCrV{sub 2}O{sub 7} (ie-NaCrV{sub 2}O{sub 7}) were synthesized for the first time. Black-Right-Pointing-Pointer Structural characterization, spectra features and physical property measurements were carried out contrastively. Black-Right-Pointing-Pointer Alkali-metal cations in the layered structure were testified to be ion-exchangeable with smaller monovalent ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conditions for the formation of pure birnessite during the oxidation of Mn(II) cations in aqueous alkaline medium

Birnessite was synthetized through redox reaction by mixing MnO{sub 4}{sup -}, Mn{sup 2+} and OH{sup -} solutions. The Mn(VII): Mn(II) ratio of 0.33 was chosen and three methods were used consisting in a quick mixing under vigorous stirring of two of the three reagents and then on the dropwise addition of the third one. The obtained solids were characterized by XRD, FTIR and XPS spectroscopies. Their average oxidation states were determined from ICP and CEC measurements while their surface properties were investigated by XPS. This study provides an increased understanding of the importance of dissolved oxygen in the formation of birnessite and hausmannite and shows the ways to obtain pure birnessite. The role of counter-ion ie. Na{sup +} or K{sup +} was also examined. - Graphical abstract: Pathways of birnessite formation. - Highlights: • Pure birnessite is prepared through a redox reaction. • Hausmannite formation is prevented by controlling dissolved O2. • The employed counterion influences the purity of birnessite. • Initial Mn(OH){sub 2} is oxidized by both MnO{sub 4}{sup -} and dissolved O{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of alloying on intrinsic ductility in WTaCrV high entropy alloys

Tungsten (W) exhibits desirable properties for extreme applications, such as the divertor in magnetic fusion reactors, but its practicality remains limited due to poor formability and insufficient irradiation resistance. In this work, we study the intrinsic ductility of body-centered cubic WTaCrV based high entropy alloys (HEAs), which are known to exhibit excellent irradiation resistance. The ductility evaluations are carried out using a criterion based on the competition between the critical stress intensity factors for emission (K Ie ) and cleavage (K Ic ) in the {110} slip planes and {110} crack planes, which are evaluated within the linear elastic fracture mechanics framework and computed using density functional theory. The results suggest that increasing the alloying concentrations of V and reducing the concentrations of W can significantly improve the ductility in these HEAs. The elastic anisotropy for these HEAs is analyzed using the Zener anisotropy ratio and its correlation with the concentration of W in the alloys is studied. Results indicate that these alloys tend to be fairly isotropic independently from the concentration of W in them. The computed data for the elastic constants of these HEAs is also compared against available experimental data. The results are in good agreement, validating the robustness and accuracy of the computational methods. Multiple phenomenological ductility metrics were also computed and analyzed against the analytical model. Some metrics, mainly the surrogate D parameter, show a good correlation with the Rice model. The potential of these empirical metrics to serve as surrogate screening models for optimizing the compositional space is also discussed.

Anisotropy↗

Simulation of differential die-away instrument’s response to asymmetrically burned spent nuclear fuel

Here, previous simulation studies of Differential Die–Away (DDA) instrument’s response to active interrogation of spent nuclear fuel from a pressurized water reactor (PWR) yielded promising results in terms of its capability to accurately measure or estimate basic spent fuel assembly (SFA) characteristics, such as multiplication, initial enrichment (IE) and burn-up (BU) as well as the total plutonium content. These studies were however performed only for a subset of idealized SFAs with a symmetric BU with respect to its longitudinal axis. Therefore, to complement the previous results, additional simulations have been performed of the DDA instrument’s response to interrogation of asymmetrically burned spent nuclear fuel in order to determine whether detailed assay of SFAs from all 4 sides will be necessary in real life applications or whether a cost and time saving single sided assay could be used to achieve results of similar quality as previously reported in case of symmetrically burned SFAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

London penetration depth of electron-irradiated Ba 0 . 47 K 0 . 53 Fe 2 As 2

We have characterized an electron-irradiated Ba 1-x K x Fe 2 As 2 (x = 0.53) single-crystal using two different experimental techniques: magneto-optic measurements and microwave measurements. The crystal has been measured before as well as after the 2.5 MeV electron irradiation process. After irradiation it was annealed in a number of steps, between 90 °C and 180 °C, and measured after each annealing step. Most microwave measurements were performed by means of a copper cavity, taking advantage of the TE 011 and TM 110 modes, allowing for the determination of the London penetration depths changes δλ ab (T) and δλ c (T), ie perpendicular and parallel to the sample c-axis. Appropriate equations, based on perturbation theory, were derived to calculate the penetration depths changes δλ ab and δλ c for a rectangular prism geometry. The sample showed a full recovery of its T c , however the observed behavior of δλ c and δλ ab was not monotonic vs annealing temperature, displaying a minimum of δλ c and δλ ab at 120 °C. In conclusion, this finding was confirmed by magneto-optic measurements, where besides verifying the sample uniformity and the absence of visible defects, the lower critical field H c1 of the Ba 1-x K x Fe 2 As 2 single-crystal was obtained and the London penetration depth λab(0) was calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗