Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydrogen Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A neutral-atmosphere composition experiment for the Atmosphere Explorer-C, -D, and -E.

The neutral-atmosphere composition experiment instrumentation is designed to obtain in-situ measurements of neutral thermosphere composition from Atmosphere Explorer-C, -D, and -E. The system is based on previously flown OGO-6 and San Marco-3 composition instruments. The mass-spectrometer sensor includes a gold-plated thermalizing chamber and ion source, a hyperbolic rod quadrupole analyzer, and an off-axis electron multiplier. Automatic ion-source sensitivity control and pulse-counting techniques provide density measurement capability from approximately 125 to 1000 km altitude. The normal operating mode includes measurement at all masses in the range of 1 to 44 amu, with emphasis on hydrogen, helium, oxygen, nitrogen, and argon.

Pelz, D. T.↗

Smart medical systems with application to nutrition and fitness in space

Smart medical systems are being developed to allow medical treatments to address alterations in chemical and physiologic status in real time. In a smart medical system, sensor arrays assess subject status, which is interpreted by computer processors that analyze multiple inputs and recommend treatment interventions. The response of the subject to the treatment is again assessed by the sensor arrays, thus closing the loop. An early form of "smart medicine" has been practiced in space to assess nutrition. Nutrient levels are assessed with food frequency questionnaires, which are interpreted by flight surgeons to recommend inflight alterations in diet. In the future, sensor arrays will directly probe body chemistry. Near-infrared spectroscopy can be used to non-invasively measure several blood and tissue parameters that are important in the assessment of nutrition and fitness. In particular, this technology can be used to measure blood hematocrit and interstitial fluid pH. The non-invasive measurement of interstitial pH is discussed as a surrogate for blood lactate measurement for the development and real-time assessment of exercise protocols in space. Earth-based application of these sensors is also described.

NASA Discipline Life Sciences Technologies↗

Hydrogen sensing and separation

Techniques for hydrogen sensing and mitigation are provided. As one example, a device includes a chamber and a membrane that is permeable to a first gas and is impermeable to a second gas. The membrane separates the chamber from a gas mixture that contains the first gas, such that the first gas in the gas mixture can only enter the chamber via the membrane. The device also includes a pressure sensor configured to measure a pressure within the chamber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-Principles Investigation of Near-Surface Divacancies in Silicon Carbide

The realization of quantum sensors using spin defects in semiconductors requires a thorough understanding of the physical properties of the defects in the proximity of surfaces. We report a study of the divacancy (V Si V C ) in 3C-SiC, a promising material for quantum applications, as a function of surface reconstruction and termination with -H, -OH, -F and oxygen groups. Here we show that a V Si V C close to hydrogen-terminated (2 x 1) surfaces is a robust spin-defect with a triplet ground state and no surface states in the band gap and with small variations of many of its physical properties relative to the bulk, including the zero-phonon line and zero-field splitting. However, the Debye-Waller factor decreases in the vicinity of the surface and our calculations indicate it may be improved by strain-engineering. Overall our results show that the V Si V C close to SiC surfaces is a promising spin defect for quantum applications, similar to its bulk counterpart.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SLS Test Stand Site Selection

Test site selection is a critical element of the design, development and production of a new system. With the advent of the new Space Launch System (SLS), the National Aeronautics and Space Administration (NASA) had a number of test site selection decisions that needed to be made early enough in the Program to support the planned Launch Readiness Date (LRD). This case study focuses on decisions that needed to be made in 2011 and 2012 in preparation for the April 2013 DPMC decision about where to execute the Main Propulsion Test that is commonly referred to as "Green Run." Those decisions relied upon cooperative analysis between the Program, the Test Lab and Center Operations. The SLS is a human spaceflight vehicle designed to carry a crew farther into space than humans have previously flown. The vehicle consists of four parts: the crew capsule, the upper stage, the core stage, and the first stage solid rocket boosters. The crew capsule carries the astronauts, while the upper stage, the core stage, and solid rocket boosters provide thrust for the vehicle. In other words, the stages provide the "lift" part of the lift vehicle. In conjunction with the solid rocket boosters, the core stage provides the initial "get-off-the-ground" thrust to the vehicle. The ignition of the four core stage engines and two solid rocket boosters is the first step in the launch portion of the mission. The solid rocket boosters burn out after about 2 minutes of flight, and are then jettisoned. The core stage provides thrust until the vehicle reaches a specific altitude and speed, at which point the core stage is shut off and jettisoned, and the upper stage provides vehicle thrust for subsequent mission trajectories. The integrated core stage primarily consists of a liquid oxygen tank, a liquid hydrogen tank, and the four core stage engines. For the SLS program, four RS-25 engines were selected as the four core stage engines. The RS-25 engine is the same engine that was used for Space Shuttle. The test plan for the integrated core stage was broken down into several segments: Component testing, system level testing, and element level testing. In this context, components are items such as valves, controllers, sensors, etc. Systems are items such as an entire engine, a tank, or the outer stage body. The core stage itself is considered to be an element. The rocket engines are also considered an element. At the program level, it was decided to perform a single green run test on the integrated core stage prior to shipment of it to Kennedy Space Center (KSC) for use in the EM-1 test flight of the SLS vehicle. A green run test is the first live fire of the new integrated core stage and engine elements - without boosters of course. The SLS Program had to decide where to perform SLS green run testing.

Crowe, Kathryn↗

Electrolysis Performance Improvement Concept Study (EPICS) Flight Experiment-Reflight

The Electrolysis Performance Improvement Concept Study (EPICS) is a flight experiment to demonstrate and validate in a microgravity environment the Static Feed Electrolyzer (SFE) concept which was selected for the use aboard the International Space Station (ISS) for oxygen (O2) generation. It also is to investigate the impact of microgravity on electrochemical cell performance. Electrochemical cells are important to the space program because they provide an efficient means of generating O2 and hydrogen (H2) in space. Oxygen and H2 are essential not only for the survival of humans in space but also for the efficient and economical operation of various space systems. Electrochemical cells can reduce the mass, volume and logistical penalties associated with resupply and storage by generating and/or consuming these gases in space. An initial flight of the EPICS was conducted aboard STS-69 from September 7 to 8, 1995. A temperature sensor characteristics shift and a missing line of software code resulted in only partial success of this initial flight. Based on the review and recommendations of a National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) review team a reflight activity was initiated to obtain the remaining desired results, not achieved during the initial flight.

Schubert, F. H.↗

Study of Acoustic Emissions from Composites

The nondestructive evaluation (NDE) of future propulsion systems utilizing advanced composite structures for the storage of cryogenic fuels, such as liquid hydrogen or oxygen, presents many challenges. Economic justification for these structures requires light weight, reusable components with an infrastructure allowing periodic evaluation of structural integrity after enduring demanding stresses during operation. A major focus has been placed on the use of acoustic emission NDE to detect propagating defects, in service, necessitating an extensive study into characterizing the nature of acoustic signal propagation at very low temperatures and developing the methodology of applying AE sensors to monitor cryogenic components. This work addresses the question of sensor performance in the cryogenic environment. Problems involving sensor mounting, spectral response and durability are addressed. The results of this work provides a common point of measure from which sensor selection can be made when testing composite components at cryogenic temperatures.

Walker, James L.↗

Study Acoustic Emissions from Composites

The nondestructive evaluation (NDE) of future propulsion systems utilizing advanced composite structures for the storage of cryogenic fuels, such as liquid hydrogen or oxygen, presents many challenges. Economic justification for these structures requires, light weight, reusable components with an infrastructure allowing periodic evaluation of structural integrity after enduring demanding stresses during operation. A major focus has been placed on the use of acoustic emission NDE to detect propagating defects, in service, necessitating an extensive study into characterizing the nature of acoustic signal propagation at very low temperatures and developing the methodology of applying AE sensors to monitor cryogenic components. This work addresses the question of sensor performance in the cryogenic environment. Problems involving sensor mounting, spectral response and durability are addressed. The results of this work provides a common point of measure from which sensor selection can be made when testing composite components at cryogenic temperatures.

Walker, James L.↗

A spectral study of a radio-frequency plasma-generated flux of atomic oxygen

The active environment of a radio-frequency (RF) plasma generator, with and without low-pressure oxygen, has been characterized through the identification of emission lines in the spectral region from 250 to 900 nm. The environment is shown to be dependent on the partial pressure of oxygen and the power applied to the RF generator. Atomic oxygen has been found in significant amounts as well as atomic hydrogen and the molecular oxygen species O2((sup 1)Sigma). The only charged species observed was the singly charged molecular ion O2(+). With a polymer specimen in the plasma chamber, carbon monoxide was also observed. The significance of these observations with respect to previous studies using this type of generator to stimulate material degradation in space is discussed. The possibility of using these generators as atomic oxygen sources in the development of oxygen atom fluorescence sensors is explored.

Batten, Carmen E.↗

Molecular To Mesoscale Targeting of Oxoanions with Multi-Tasking Hosts

Achieving a better understanding of anion interactions both in solution and crystalline state was the overarching goal of this project. Anions are everywhere throughout Nature and play important roles in biological and environmental processes. They can be beneficial or deleterious or both in different situations and concentrations. For either reason it is important to have molecules that can bind anions for key needs that benefit society. However, recognition of specific anions is challenging due to the diffuse nature of their negative charge(s) as well as their various shapes and sizes. Understanding the basic properties of anions and how they interact with other molecules and ions in surrounding environments is key to selective recognition. In this project multi-tasking molecules for selective binding of targeted anions were designed to achieve cooperativity and synergism in one rather than multiple host molecules, including (1) cation:anion pair hosts for anions with charges of -2 or greater; (2) pH and redox activated hosts for on-off binding and release; and (3) multiple anion capture in extended host networks. Our design strategy was to combine the use of simple inexpensive building blocks and high yield synthetic pathways to provide economically feasible scale-up for applications. Oxoanions representing multiple shapes and charges were chosen based on having the potential for significant impact on DOE separations needs. Amide/amine-based macrocycles and urea/amine-based chelates and macrocycles with multiple hydrogen bonding sites provided the basic anion-binding frameworks. Successful multi-tasking outcomes were forthcoming in all three tasks. In Task 1, successful ion pair binding for anions with multiple charges was achieved. Furthermore, the ion pair molecules were capable of extended interactions through supramolecular intertwining, like fishing nets for capturing pools of fish (also fitting with Task 3). In Task 2, molecules were synthesized possessing on-off switches. These included a pH sensitive sensor for on-off binding of anions in general, as well as an electrochemical sensor selective for sulfate capture. Three new classes of extended anion host networks capable of binding multiple ions was a major outcome of Task 3. These systems included: anion sensitive, fluorescent organogels; channel-forming macrocycles for studying anion-water including larger macrocyclic cluster sandwiches; and, the offshoot of Task 1, fishing net ion-pair networks for higher valent anions. These strategies can be expanded in the future to other ions and molecules for a better understanding of intermolecular and interionic interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of High Yield, Ultra‐Shallow Nitrogen‐Vacancy Centre Ensembles Through High Purity Forming gas Annealing

Dense, ultra‐shallow (<10 nm from the surface) ensembles of nitrogen‐vacancy (NV) centers in diamond are sought‐after for realising practical quantum sensing at the nanoscale. However, these ensembles typically suffer from reduced NV creation efficiency and spin coherence compared to their deeper and bulk counterparts. Consequently, most demonstrations in the literature to date have been restricted to using single NV centers with atypical coherence and charge stability properties not achievable across entire ensembles. Here, in this work, we demonstrate that controlled annealing in a high purity forming gas atmosphere improves near‐surface NV formation efficiency to over 20%. This environment preserves a high quality hydrogen termination throughout the anneal, avoiding material etching over many hours at temperatures up to 1100°C and possibly helping to suppress vacancy out‐diffusion. We show that high temperature annealing is especially vital for improving spin properties in high density, ultra‐shallow implanted samples due to the localised damage profiles produced. By allowing the formation of high yield NV ensembles with improved spin properties, the optimised forming gas anneal can facilitate the reliable production of more sensitive diamond sensors than have previously been accessible.

Healey, Alexander J. [Royal Melbourne Institute of↗

A robust and multifunctional calcium coordination polymer as a selective fluorescent sensor for acetone and iron (+3) and as a tunable proton conductor

A multifunctional calcium coordination polymer (Ca-CP) formulated as [(CH 3 ) 2 NH 2 ][Ca(Me 2 tcpbH)(H 2 O)] (1) has been synthesized and characterized. Compound 1 features a robust and novel three-dimensional (3D) network with cage-like cavities. The high thermal and moisture stability of the title compound makes it a good candidate for possible environment or energy related applications. Fluorescence (FL) studies demonstrate that 1 shows emission with a maximum at 350 nm under 270 nm excitation. The title compound acts as a selective and sensitive fluorescent sensor for the detection of acetone and Fe 3+ ions at low concentrations. The FL intensity quenching percentage and the concentration ratio of Fe 3+ /Fe 2+ showed a linear relation with a Fe 3+ concentration as low as 50 μM in Fe 2+ aqueous solutions, offering an easy way to probe the extent of Fe 2+ oxidation. Moreover, due to the relatively high hydration character of Ca 2+ , the terminal water molecules and undeprotonated carboxylate groups form a strong hydrogen-bonded network within the structure, facilitating its tunable proton conduction under various humidity and temperature conditions. The proton conducting mechanism has been investigated using PXRD, IR, and EA methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A magnetostatic-coupling based remote query sensor for environmental monitoring

A new type of in situ, remotely monitored magnetism-based sensor is presented that is comprised of an array of magnetically soft, magnetostatically-coupled ferromagnetic thin-film elements or particles combined with a chemically responsive material that swells or shrinks in response to the analyte of interest. As the chemically responsive material changes size the distance between the ferromagnetic elements changes, altering the inter-element magnetostatic coupling. This in turn changes the coercive force of the sensor, the amplitude of the voltage spikes detected in nearby pick-up coils upon magnetization reversal and the number of higher-order harmonics generated by the flux reversal. Since the sensor is monitored through changes in magnetic flux, no physical connections such as wires or cables are needed to obtain sensor information, nor is line of sight alignment required as with laser telemetry; the sensors can be detected from within sealed, opaque or thin metallic enclosures.

NASA Discipline Life Sciences Technologies↗

High-performance piezoelectric composites via β phase programming

Polymer-ceramic piezoelectric composites, combining high piezoelectricity and mechanical flexibility, have attracted increasing interest in both academia and industry. However, their piezoelectric activity is largely limited by intrinsically low crystallinity and weak spontaneous polarization. Here, we propose a Ti 3 C 2 T x MXene anchoring method to manipulate the intermolecular interactions within the all-trans conformation of a polymer matrix. Employing phase-field simulation and molecular dynamics calculations, we show that OH surface terminations on the Ti 3 C 2 T x nanosheets offer hydrogen bonding with the fluoropolymer matrix, leading to dipole alignment and enhanced net spontaneous polarization of the polymer-ceramic composites. We then translated this interfacial bonding strategy into electrospinning to boost the piezoelectric response of samarium doped Pb (Mg1/3Nb 2/3 )O 3 -PbTiO 3 /polyvinylidene fluoride composite nanofibers by 160% via Ti 3 C 2 T x nanosheets inclusion. With excellent piezoelectric and mechanical attributes, the as-electrospun piezoelectric nanofibers can be easily integrated into the conventional shoe insoles to form a foot sensor network for all-around gait patterns monitoring, walking habits identification and Metatarsalgi prognosis. This work utilizes the interfacial coupling mechanism of intermolecular anchoring as a strategy to develop high-performance piezoelectric composites for wearable electronics.

36 MATERIALS SCIENCE↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO 3 -based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO 3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO 3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO 3 /carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO 3 /CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression I pa = 3.73 [AMXL] + 0.77 with R 2 = 0.96 and at 0.1 to 30.0 μM with the linear regression I pa = 3.76 [AMXL] + 0.69 with R 2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM –1 cm –2 , respectively. Furthermore, Co-WO 3 /CPE showed high selectivity and anti-interference capabilities. In conclusion, the sensing and disposable Co-WO 3 /CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Shanbhag, Mahesh M. [KLE Technological University,↗

Implementation of Real-Time Hardware in the Loop Simulation for WAVE Instrument Avionics

The Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE) payload will lead the Resource Prospector rover to hydrogen-rich locations on the moon supporting NASA's in-situ resource utilization (ISRU) mission. The Water Analysis and Volatile Extraction (WAVE) system will be responsible for heating up regolith samples and analyzing their volatiles in a vaporized state. Given the space environment, testing flight hardware and software using the scientific instruments can be costly and time consuming, which can hold back progress involving the instruments. A hardware-in-the-loop (HITL) simulation will test the Avionics Data Acquisition as well as the Instrument Interface Unit, through simulating sensors and actuators involved in supporting the WAVE instruments. HITL is a platform for testing and developing WAVE's avionics and software, where the simulation plant will imitate the LAVA and OVEN instruments, thus allowing for an accessible, efficient, and replicable testing environment.

Al Qaraghuli, Ali↗