Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Voltage Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of divertor electrical drifts on particle distribution and detachment near the divertor target plate in DIII-D

Strong impacts of drifts on the divertor plasma in–out asymmetry and detachment are demonstrated in DIII-D with an open divertor configuration. For forward toroidal field, B T , i.e., with the ion B × ∇B drift toward the divertor, the particle flux to the inner divertor, as represented by the Langmuir probe measured ion saturation current (J sat ), exhibits a double peak structure, with electron temperature, lower at the inner target. Reversing the B T direction reverses both the radial and poloidal E × B flows, leading to a broad particle flux profile in the outboard scrape-off layer (SOL) with a similar double-peak structure to that observed at the inner target with forward B T . The correlation of a double peak structure with divertor temperature profiles confirms physical coupling between the drift flow and sheath boundary condition and their strong impact on divertor profiles. In addition, under reversed B T conditions, increasing the density flattens the target temperature profile. However, J sat remains high away from the strike point, rendering it difficult to achieve an “effective” detached plasma, i.e., with effective reduction in both peak heat flux and peak temperature (in the far SOL). In contrast, divertor detachment with a cold and flat temperature profile can be achieved at both target plates with the forward B T .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SULI Research Report

Acoustic levitation allows for the containerless manipulation of small samples limited by density, size, and shape. Modern acoustic levitators are either constructed with Langevin horns, which need to be machined to high tolerance and require at least 100V, or ultrasonic transducers, which are robust to changes in temperature and require low voltage. We investigated the ability of the TinyLev, a commercially available single axis levitator, and prototyped a two-axis levitator. Both the TinyLev and our two-axis levitator employ phased arrays of transducers and operate at 40 kHz. Models produced with the Python toolbox Levitate showed the characteristic nodes of the TinyLev and found two previously unpublished “traps” (stable local pressure minima) of the twoaxis levitator. We plan to use these levitators at the Advanced Photon Source (APS) to study a variety of samples, via white beam diffraction and high speed imaging. It is our goal to calculate the radial distribution function with respect to temperature across phase transitions.

42 ENGINEERING↗

Reversible Electrochemical Lithium Cycling in a Vanadium(IV)- and Niobium(V)-Based Wadsley–Roth Phase

Fast charging remains one of the greatest safety challenges in Li-ion batteries due to Li-dendrite growth occurring on graphite anodes if they are lithiated too quickly. The search for high-rate anodes has highlighted materials in the Wadsley–Roth (WR) shear phase family. The relative abundance of V compared with traditional WR compositions of Nb and W makes V-based phases attractive. However, the high voltage and poor reversibility typically associated with V redox have made V-rich WR phases less studied than Nb- and W-rich phases. Here, we show that a new V-rich Wadsley–Roth phase, V 7 Nb 6 O 29 , achieves excellent rate capability and 80% capacity retention after 228 cycles with a relatively low average voltage of 1.76 V vs Li/Li + compared with other V-rich WR phases. Single-crystal X-ray diffraction reveals a P4/m space group with repeating 2 × 2 × ∞ and 3 × 3 × ∞ blocks of V 4+ and Nb 5+ octahedra. Finally, combined neutron pair distribution function analysis, X-ray absorption spectroscopy, and density functional theory calculations show that V redox is the primary source of capacity and that cycling stability is provided by the stable octahedral coordination adopted by V 4+ in the material.

25 ENERGY STORAGE↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

An Environmentally Benign Electrolyte for High Energy Lithium Metal Batteries

In this work, a hybrid electrolyte comprising a high content of H 2 O for a lithium metal cell is reported. At high LiFSI salt concentration, the N-methyl-N-propyl-piperidinium bis(fluorosulfonyl) imide (PMpipFSI) electrolyte can tolerate up to 1 M H2O addition without sacrificing its redox stability on both lithium nickel manganese cobalt oxide (NMC) cathode and lithium metal anode. Molecular dynamics simulations revealed the underpinned mechanism that, at high salt concentrations, H 2 O molecules are embedded in the Li + , PMpip + , and FSI - bulk as a structural material with a strong solvation with Li + and are orderly distributed at the surface of both electrodes. This electrolyte eliminates the critical moisture controls required for the state-of-the-art (SOA) carbonate/LiPF 6 electrolyte, electrode, separator and cell assembly, thus significantly reducing the cost of the mass production of the batteries.

molecular dynamics simulation↗

Reverse-Bias Resilience of Monolithic Perovskite/Silicon Tandem Solar Cells

Metal halide perovskites have rapidly enabled a range of high-performance photovoltaic technologies. However, catastrophic failure under reverse voltage bias poses a roadblock for their commercialization. In this work, we conduct a series of stress tests to compare the reverse-bias stability of perovskite single-junction, silicon single-junction, and monolithic perovskite/silicon tandem solar cells. We demonstrate that the tested perovskite/silicon tandem devices are considerably more resilient against reverse bias compared with perovskite single-junction devices. The origin of such improved stability stems from the low reverse-bias diode current of the silicon subcell. This translates to dropping most of the voltage over the silicon subcell, where such a favorable voltage distribution protects the perovskite subcell from reverse-bias-induced degradation. These results highlight that, compared with other perovskite technologies, monolithic perovskite/silicon tandems are at a higher technology readiness level in terms of tackling the reverse bias and partial shading challenges, which is a considerable advantage toward commercialization.

halide perovskite↗

Carbon Support Microstructure Impact on High Current Density Transport Resistances in PEMFC Cathode

Cell voltages at high current densities (HCD) of an operating proton-exchange membrane fuel cell (PEMFC) cathode suffer from losses due to the local-O 2 and bulk-H + transport resistances in the catalyst layer. Particularly, the microstructure of high surface area carbon (HSC) support upon which both the platinum catalyst and ionomer are dispersed play a pivotal role in controlling the reactant transport to the active site in the catalyst layer. In this study, we perform a systematic analysis of the underlying microstructure of platinum-cobalt catalyst dispersed on various HSC supports in terms of their surface area and pore-size distribution. The carbon microstructure was found to strongly influence the PtCo nanoparticle dispersion, catalyst layer ionomer distribution and transport losses governing the performance at HCD. Catalyst layer electrochemical diagnostics carried out to quantify local-O 2 transport resistance and bulk-H + transport resistance in the cathode were found to be directly correlated to the micropore (<2 nm) and macropore (>8 nm) surface areas of the carbon support, respectively. Finally, a 1D-performance model has been developed to assimilate our understanding of the catalyst layer microstructure and transport resistances at HCD.

25 ENERGY STORAGE↗

Visualizing degradation mechanisms in a gas-fed CO 2 reduction cell via operando X-ray tomography

We utilize operando X-ray computed tomography, coupled with real-time electrochemical analysis, to reveal the underlying failure mechanisms of membrane electrode assemblies (MEAs) for electrochemical CO 2 reduction (eCO 2 R). Through operando imaging, we can obtain unprecedented insights into the dynamic behavior of the MEA under different operating conditions, revealing critical changes in interface interactions, phase distribution, and structural integrity over time. Our findings identify phenomena giving rise to the transition from CO 2 R to the hydrogen evolution reaction (HER), as evidenced by shifts in cathode potential and CO 2 R selectivity. The formation of inhomogeneous precipitates at the gas diffusion electrode disrupts the CO 2 supply and reduces the active sites for eCO 2 R, resulting in a shift toward H2 production during low current density operation. Additionally, under high current density conditions, rapid water crossover up to the microporous layer/gas diffusion layer promotes the transition from CO 2 R to HER, further shifting cell potential toward anodic direction. Oscillating voltage conditions reveal the dissolution and regrowth of precipitates, providing direct visualization of the competing selectivity of CO 2 R and HER. This work offers new insight into the degradation mechanisms of MEAs, with implications for the design of more durable CO 2 R systems.

Lee, Sol A [California Institute of Technology (Ca↗

Testbed Demonstration of a Microgrid Building Block Prototype

With the adoption of ambitious climate action goals, the penetration level of distributed energy resources (DERs) is rapidly increasing. Microgrids are an efficient way to integrate these DERs, facilitating their operation and control. Additionally, microgrids enhance the overall resilience of the distribution system by serving critical loads both within and outside their boundaries. However, the need for substantial customized engineering leads to a high cost of development, installation and maintenance of microgrids. To address this challenge, Microgrid Building Blocks (MBB) are proposed to reduce the deployment cost of microgrids through modular, standardized design and implementation. This work presents a testbed demonstrating the integrated power conversion, control, and communication functionalities of an MBB. The testbed is formed by a real-time electromagnetic transient (EMT) simulation combined with a hardware and software prototype of MBB. The use cases supported by the MBB testbed are enumerated. The islanded operation, voltage regulation, and optimal dispatch capabilities of an MBB-based microgrid controller are validated through a case study.

Somda, Baza [Virginia Tech]↗

Regulating the Electron Distribution of Metal-Oxygen for Enhanced Oxygen Stability in Li-rich Layered Cathodes

Li-rich Mn-based layered oxides (LLO) hold great promise as cathode materials for lithium-ion batteries (LIBs) due to their unique oxygen redox (OR) chemistry, which enables additional capacity. However, the LLOs face challenges related to the instability of their OR process due to the weak transition metal (TM)-oxygen bond, leading to oxygen loss and irreversible phase transition that results in severe capacity and voltage decay. Herein, a synergistic electronic regulation strategy of surface and interior structures to enhance oxygen stability is proposed. In the interior of the materials, the local electrons around TM and O atoms may be delocalized by surrounding Mo atoms, facilitating the formation of stronger TM—O bonds at high voltages. Besides, on the surface, the highly reactive O atoms with lone pairs of electrons are passivated by additional TM atoms, which provides a more stable TM—O framework. Hence, this strategy stabilizes the oxygen and hinders TM migration, which enhances the reversibility in structural evolution, leading to increased capacity and voltage retention. This work presents an efficient approach to enhance the performance of LLOs through surface-to-interior electronic structure modulation, while also contributing to a deeper understanding of their redox reaction.

25 ENERGY STORAGE↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cation Selectivity in Capacitive Deionization: Elucidating the Role of Pore Size, Electrode Potential, and Ion Dehydration

Capacitive deionization (CDI) is a promising water desalination technology that is applicable to the treatment of low-salinity brackish waters and the selective removal of ionic contaminants. In this work, we show that by making a small change in the synthetic procedure of hierarchical carbon aerogel monolith (HCAM) electrodes, we can adjust the pore-size distribution and tailor the selectivity, effectively switching between selective adsorption of calcium or sodium ions. Ion selectivity was measured for a mixture of 5 mM NaCl and 2.5 mM CaCl 2 . For the low activated flow-through CDI (fteCDI) cell, we observed extremely high sodium selectivity over calcium (S Na/Ca $\gg$ 10, no Ca 2+ adsorbed) at all of the applied potentials, while for the highly activated fteCDI cell, we observed a selectivity value of 6.6 ± 0.8 at 0.6 V for calcium over sodium that decreased to 2.2 ± 0.03 at 1.2 V. Molecular dynamics simulations indicated that the loss in Ca 2+ selectivity over Na+ at high applied voltages could be due to a competition between ion-pore electrostatic interactions and volume exclusion (“crowding”) effects. Interestingly, we also find with these simulations that the relative sizes of the ions change due to changes in hydration at a higher voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗