Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Angular Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

AS04-AS02-133 Electroformed-Nickel Hard-X-Ray Optic Development at NASA/MSFC

We are developing the nickel electroforming process to fabricate high-quality mirrors for the region. Two applications for these optics are a balloon-borne payload, termed HERO, and a hard-X-ray telescope module for consideration for the Constellation-X mission. In the formation on shells, of 15 arcsec angular resolution, will provide over 200 sq cm of effective collecting area unprecedented sensitivity in the 20-75 keV region. A first flight of a partial payload, feature approximately 1/4 of the total collecting area, is scheduled for the Spring of 2004. In the Co-application, two mirror shells, of diameters 150 and 230 mm, are being fabricated. This is particularly challenging as high angular resolution must be maintained with shells of only 1 mm thickness (driven by the tight weight budget for the mission). Further, the shells must be low (less than 5 A on sub-micron spatial scales) to permit efficient use of planned multilayer coatings which must release cleanly from their forming mandrels without any surface degradation.

Ramsey, Brian↗

The High Resolution Telescope Cluster. I - Overview and technical status

A major component of the Advanced Solar Observatory is the High Resolution Telescope Cluster (HRTC) for investigations of the solar atmosphere at soft X-ray, XUV, EUV, and VUV wavelengths, via high resolution spectroheliograms in lines and continuum emitted over the full, (4500 to 100,000,000 K) range of temperatures of the outer solar atmosphere; angular resolution may be as high as 0.03 arcsec. An analysis is conducted of a model HRTC instrument complement encompassing a 60-90 cm aperture VUV telescope, a 40-50 cm aperture EUV telescope, three 40-50 cm aperture XUV telescopes, and a 40-cm aperture soft X-ray telescope, as well as flare spectrometers and polarimeters and four coronagraph/spectrographs.

Walker, Arthur B. C., Jr.↗

Variations of Strahl Properties with Fast and Slow Solar Wind

The interplanetary solar wind electron velocity distribution function generally shows three different populations. Two of the components, the core and halo, have been the most intensively analyzed and modeled populations using different theoretical models. The third component, the strahl, is usually seen at higher energies, is confined in pitch-angle, is highly field-aligned and skew. This population has been more difficult to identify and to model in the solar wind. In this work we make use of the high angular, energy and time resolution and three-dimensional data of the Cluster/PEACE electron spectrometer to identify and analyze this component in the ambient solar wind during high and slow speed solar wind. The moment density and fluid velocity have been computed by a semi-numerical integration method. The variations of solar wind density and drift velocity with the general build solar wind speed could provide some insight into the source, origin, and evolution of the strahl.

Figueroa-Vinas, Adolfo↗

Fabrication of a Hybrid Transition Edge Sensor Array for Lynx

Lynx is a proposed NASA X-Ray telescope flight mission aimed at achieving state-of-the-art angular and energy resolution with a 100 kilopixel array to probe the hot energetic young universe in unprecedented detail. To achieve these goals, our team plans on leveraging our current work in development of the focal plane for the Athena X-Ray Integral Field Unit (X-IFU) while advancing the state-of-the-art in transition edge sensor (TES) X-ray detector technology. The TES is an optimal technology for achieving both high energy and fine angular resolution at the same time because pixel features can be made extremely small and the absorber which dominates the heat capacity can be tuned to meet resolution requirements. Specifically, the proposed mission concept calls for a hybrid detector of three different arrays fabricated in the same planar process in one focal plane and optimized for different science goals. The main arrays consist of 5x5 hydras, 25 pixels of 4 micron thick Au absorbers each with a different thermal link to one common TES. The outer array has absorbers on a 50-micron pitch for most of the 5 arc-minute field-of-view, and the inner array has 25-micron absorbers for the central 1 arc-minute region. A high resolution array consisting of single pixel 1 micron thick Au absorbers on 50-micron pitch will lie off to the side. Reading out an array of this magnitude will likely require improvements in indium bump bonding to superconducting flexible wiring. Fabrication of absorbers of two different sizes requires electroplating through a photoresist mold by careful tuning of the current density to achieve uniform flat absorbers on a fine pitch scale, followed by ion milling to yield narrow streets separating the pixels while preserving high quantum efficiency. We report on progress made at fabricating the hybrid array with different absorber sizes and thicknesses. Further, we also report on ongoing work to adequately heat sink the pixels with backside wire bonding and copper coating. We also report on work to improve detector pixel yield and top side indium bump bonding to flexible wiring.

Focal plane array↗

Instrument Development for X-Ray Astronomy

Current x-ray observatories such as Chandra and XMM-Newton have delivered spectacular results at soft-x-ray energies thanks to their grazing incidence mirrors. To continue these advances necessitates the development of mirrors with even larger collecting areas, yet within manageable weights and budgets, and focal detectors with improved energy resolution. At higher energies where x-ray critical-grazing angles become very small, x-ray optics have typically not been employed and thus this region remains relatively unexplored at high sensitivity levels and fine angular resolutions. This situation is changing with the development of hard-x-ray optics carried aloft by high-altitude balloons, which promise to bring about dramatic advances. This presentation will review developments in all these areas.

Ramsey, Brian↗

10-30 micrometer Maps of the Central 5 parsecs of the Galaxy: Heating of the Cavity and Neutral-Gas Disk

Maps are presented for 10, 20, and 30 micrometers of the central 60' X 90' (RA X Dec) of the galaxy made at approximately 4' resolution with the MSFC bolometer array. The maps are the first to show the thermal emission from dust particles in both the ionized cavity and the neutral-gas ring with high sensitivity and an angular resolution as good as several arcsec.

galaxies galaxy center infrared astronomy↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Flare stars and solar bursts - High resolution in time and frequency

Coronal loops on the sun and nearby stars are studied using observations at 20-cm wavelength with high resolution in time and frequency. Observations of the dwarf M star AD Leonis with high time resolution led to the discovery of a quasi-periodic train of circularly polarized spikes with a mean periodicity of 32 + or - 5 ms and a total duration of 150 ms. Observations at closely spaced wavelengths using the VLA revealed a narrow-band structure in solar bursts and in the slowly varying radiation of the dwarf M star YZ Canis Minoris. This narrow-band emission may be attributed to electron-cyclotron maser radiation. Maser action at the second or first harmonic of the gyrofrequency implies magnetic field strengths of 250 and 500 G, respectively. Hence, observations with high resolution in time and frequency suggest coherent processs in the coronas of the sun and dwarf M stars. It is noted that the scientific potential suggested by the present data can be realized by the development of a solar-stellar synthesis radiotelescope. This instrument would be dedicated to solar and stellar observations with high angular, temporal, and frequency resolution.

Lang, K. R.↗

Three-dimensional (3D) velocity map imaging: from technique to application

The velocity map imaging (VMI) technique was first introduced by Eppink and Parker in 1997, as an improvement to the original ion imaging method by Houston and Chandler in 1987. The method has gained huge popularity over the past two decades and has become a standard tool for measuring high-resolution translational energy and angular distributions of ions and electrons. VMI has evolved gradually from 2D momentum measurements to 3D measurements with various implementations and configurations. The most recent advancement has brought unprecedented 3D performance to the technique in terms of resolutions (both spatial and temporal), multi-hit capability as well as acquisition speed while maintaining many attractive attributes afforded by conventional VMI such as being simple, cost-effective, visually appealing and versatile. Here, in this tutorial, we will discuss many technical aspects of the recent advancement and its application in probing correlated chemical dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Solar Heating in Minor Absorption Bands

Solar radiation is the primary source of energy driving atmospheric and oceanic circulations. Concerned with the huge computing time required for computing radiative transfer in weather and climate models, solar heating in minor absorption bands has often been neglected. The individual contributions of these minor bands to the atmospheric heating is small, but collectively they are not negligible. The solar heating in minor bands includes the absorption due to water vapor in the photosynthetically active radiation (PAR) spectral region from 14284/cm to 25000/cm, the ozone absorption and Rayleigh scattering in the near infrared, as well as the O2 and CO2 absorption in a number of weak bands. Detailed high spectral- and angular-resolution calculations show that the total effect of these minor absorption is to enhance the atmospheric solar heating by approximately 10%. Depending upon the strength of the absorption and the overlapping among gaseous absorption, different approaches are applied to parameterize these minor absorption. The parameterizations are accurate and require little extra time for computing radiative fluxes. They have been efficiently implemented in the various atmospheric models at NASA/Goddard Space Flight Center, including cloud ensemble, mesoscale, and climate models.

Chou, Ming-Dah↗

Fast Plasma Instrument for MMS: Data Compression Simulation Results

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eights (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 deg x 180 deg fields-of-view (FOV) are set 90 deg apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 deg x 180 deg fan about its nominal viewing (0 deg deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the results in the DES complement of a given spacecraft generating 6.5-Mbs(exp -1) of electron data while the DIS generates 1.1-Mbs(exp -1) of ion data yielding an FPI total data rate of 6.6-MBs(exp -1). The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. Currently, the FPI data rate allocation to the CIDP is 1.5-Mbs(exp -1). Consequently, the FPI-IDPU must employ data/image compression to meet this CIDP telemetry allocation. Here, we present simulations of the CCSDS 122.0-B-1 algorithm-based compression of the FPI-DES electron data. Compression analysis is based upon a seed of re-processed Cluster/PEACE electron measurements. Topics to be discussed include: review of compression algorithm; data quality; data formatting/organization; and, implications for data/matrix pruning. To conclude a presentation of the base-lined FPI data compression approach is provided.

Barrie, A.↗

Spherical Harmonic Analysis of Particle Velocity Distribution Function: Comparison of Moments and Anisotropies using Cluster Data

This paper presents a spherical harmonic analysis of the plasma velocity distribution function using high-angular, energy, and time resolution Cluster data obtained from the PEACE spectrometer instrument to demonstrate how this analysis models the particle distribution function and its moments and anisotropies. The results show that spherical harmonic analysis produced a robust physical representation model of the velocity distribution function, resolving the main features of the measured distributions. From the spherical harmonic analysis, a minimum set of nine spectral coefficients was obtained from which the moment (up to the heat flux), anisotropy, and asymmetry calculations of the velocity distribution function were obtained. The spherical harmonic method provides a potentially effective "compression" technique that can be easily carried out onboard a spacecraft to determine the moments and anisotropies of the particle velocity distribution function for any species. These calculations were implemented using three different approaches, namely, the standard traditional integration, the spherical harmonic (SPH) spectral coefficients integration, and the singular value decomposition (SVD) on the spherical harmonic methods. A comparison among the various methods shows that both SPH and SVD approaches provide remarkable agreement with the standard moment integration method.

Gurgiolo, Chris↗

Fast Plasma Investigation for MMS: Simulation of the Burst Triggering System

The Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eight (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 degree x 180 degree fields-of-view (FOV) are set 90 degrees apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 degree x 180 degree fan about the its nominal viewing (0 deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the diffusion regions of reconnection, the highest temporal/spatial resolution mode of FPI results in the DES complement of a given spacecraft generating 6.5-Mb (raised dot) per second of electron data while the DIS generates 1.1-Mb (raised dot) per second of ion data yielding an FPI total data rate of 6.6-Mb (raised dot) per second. The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. This requires a data ranking process known as the burst trigger system. The burst trigger system uses pseudo physical quantities to approximate the local plasma environments. As each pseudo quantity will have a different value, a set of two scaling factors is employed for each pseudo term. These pseudo quantities are then combined at the instrument, spacecraft, and observatory level leading to a final ranking of data based on expected scientific interest. Here, we present simulations of the fixed point burst trigger system for the FPI. A variety of data sets based on previous mission data as well as analytical formulations are tested. Comparisons of floating point calculations versus the fixed point hardware simulation are shown. Analysis of the potential sources of error from overflows, quantization, etc. are examined and mitigation methods are presented. Finally a series of calibration curves are presented, showing the expected error in pseudo quantities based solely on the scale parameters chosen and the expected data range. We conclude with a presentation of the current base-lined FPI burst trigger approach.

Barrie, A. C.↗

Technology Development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a Candidate Large UV-Optical-Infrared (LUVOIR) Surveyor

The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x1010 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing & control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 μm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (~290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

Technology Development↗

First Peek of ASTRO-H Soft X-Ray Telescope (SXT) In-Orbit Performance

ASTRO-H (Hitomi) is a Japanese X-ray astrophysics satellite just launched in February, 2016, from Tanegashima, Japan by a JAXA's H-IIA launch vehicle. It has two Soft X-ray Telescopes (SXTs), among other instruments, that were developed by the NASA Goddard Space Flight Center in collaboration with ISAS/JAXA and Nagoya University. One is for an X-ray micro-calorimeter instrument (Soft X-ray Spectrometer, SXS) and the other for an X-ray CCD camera (Soft X-ray Imager, SXI), both covering the X-ray energy band up to 15 keV. The two SXTs were fully characterized at the 30-m X-ray beam line at ISAS/JAXA. The combined SXT+SXS system effective area is about 250 and 300 cm(exp 2) at 1 and 6 keV, respectively, although observations were performed with the gate valve at the dewar entrance closed, which blocks most of low energy X-rays and some of high energy ones. The angular resolution for SXS is 1.2 arcmin (Half Power Diameter, HPD). The combined SXT+SXI system effective area is about 370 and 350 cm (exp 2) at 1 and 6 keV, respectively. The angular resolution for SXI is 1.3 arcmin (HPD). The both SXTs have a field of view of about 16 arcmin (FWHM of their vignetting functions).The SXT+SXS field of view is limited to 3 x 3 arcmin by the SXS array size. In-flight data available to the SXT team was limited at the time of this conference and a point-like source data is not available for the SXT+SXS. Although due to lack of attitude information we were unable to reconstruct a point spread function of SXT+SXI, according to RXJ1856.5-3754 data, the SXT seems to be working as expected in terms of imaging capability. As for the overall effective area response for both SXT+SXS and SXT+SXI, consistent spectral model fitting parameters with the previous measurements were obtained for Crab and G21.5-0.9 data. On the other hand, their 2-10 keV fluxes differ by about 20% at this point. Calibration work is still under progress. The SXT is the latest version of the aluminum foil X-ray mirror, which is extremely light-weight and very low cost, yet produces large effective area over a wide energy-band. Its area-mass ratio is the largest, 16 cm(exp 2)/kg, among ASTRO-H, Chandra, and XMM-Newton mirrors. The aluminum foil mirror is a still compelling technology depending on the mission science goal.

X-rays↗

Spatial heterodyne spectroscopy for the exploration of diffuse interstellar emission lines at far-ultraviolet wavelengths

Spatial heterodyne spectroscopy (SHS) is a new instrumental technique for interference spectroscopy which promises to extend into the FUV (1200-2000 A) spectral region the large throughput advantage at high spectral resolution usually associated with Fabry-Perot and Michelson interferometers. In addition, SHS systems are compact in size, can be field-widened to increase their throughput even further, have no moving parts, and can be built in all-reflection configurations. SHS appears to be well suited for high resolution, space-based spectroscopy of faint interstellar emission lines in the ultraviolet. This has significant implications for the study of the dynamics and distribution of hot gas within the Galactic disk and halo. For example, a field-widened SHS incorporating 5 x 5 cm gratings could obtain a radial velocity resolved (20 km/s), 3 deg angular resolution map of the high-latitude interstellar C IV 1550 emission in less than 1 year.

Harlander, J.↗

Diffraction gratings with two-orders-of-magnitude-enhanced dispersion rates for sub-meV resolution soft X-ray spectroscopy

Diffraction gratings with large angular dispersion rates are central to obtaining high spectral resolution in grating spectrometers operating over a broad spectral range from infrared to soft X-ray domains. The greatest challenge is of course to achieve large dispersion rates in the short-wavelength X-ray domain. Here it is shown that crystals in non-coplanar asymmetric X-ray Bragg diffraction can function as high-reflectance broadband soft X-ray diffraction gratings with dispersion rates that are at least two orders of magnitude larger than those that are possible with state-of-the-art man-made gratings. Additionally, this opens new opportunities to design and implement soft X-ray resonant inelastic scattering (RIXS) spectrometers with spectral resolutions that are up to two orders of magnitude higher than what is currently possible, to further advance a very dynamic field of RIXS spectroscopy, and to make it competitive with inelastic neutron scattering. Examples of large-dispersion-rate crystal diffraction gratings operating near the 930 eV L 3 absorption edge in Cu and of the 2.838 keV L 3 -edge in Ru are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗