Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Development of Emergency Intravehicular Spacesuit (EIS) assembly

A program was undertaken to develop and test two prototype pressure suits to operate at pressures up to 413 mm Hg (8.0 PSIG). The units were designated Emergency Intravehicular Spacesuits (EIS). Performance requirements, design evolution, testing performed, problems encountered, and final EIS configuration are reported.

Source record↗

Testing of improved polyimide actuator rod seals at high temperature and under vacuum conditions for use in advanced aircraft hydraulic systems

Polyimide second-stage rod seals were evaluated to determine their suitability for applications in space station environments. The 6.35-cm (2.5-in.)K-section seal was verified for thermal cycling operation between room temperature and 478 K (400 F) and for operation in a 133 micron PA(0.000001 mm Hg) vacuum environment. The test seal completed the scheduled 96 thermal cycles and 1438 hr in vacuum with external rod seal leakage well within the maximum allowable of two drops per 25 actuation cycles. At program completion, the seals showed no signs of structural degradation. Posttest inspection showed the seals retained a snug fit against the shaft and housing walls, indicating additional wear life capability. Evaluation of a molecular flow section during vacuum testing, to inhibit fluid loss through vaporization, showed it to be beneficial with MIL-H-5606, a petroleum-base fluid, in comparison with MIL-H-83282, a synthetic hydrocarbon-base fluid.

Sellereite, B. K.↗

Six-man, self-contained carbon dioxide concentrator system

A six man, self contained electrochemical carbon dioxide concentrating subsystem was successfully designed and fabricated. It was a preprototype engineering model designed to nominally remove 6.0 kg (13.2 lb) CO2/day with an inlet air CO2 partial pressure of 400 N/sq m (3 mm Hg) and an overcapacity removal capability of 12.0 kg (26.4 lb) CO2/day. The design specifications were later expanded to allow operation at space station prototype CO2 collection subsystem operating conditions.

Powell, J. D.↗

Sputter erosion and deposition in the discharge chamber of a small mercury ion thruster

A 5-cm diameter mercury ion thruster similar to one tested for 9715 hours was operated approximately 400 hrs each at discharge voltages of 36.6, 39.6, and 42.6 V, with corresponding discharge propellant utilizations of 58, 68, and 70 percent. The observed sputter erosion rates of the internal thruster parts and the anode weight gain rate all rose rapidly with discharge voltage and were roughly in the ratio of 1:3:5 for the three voltages. The combined weight loss of the internal thruster parts nearly balanced the anode weight gain. Hg+2 ions apparently caused most of the observed erosion.

Power, J. L.↗

Horizon-glow and the motion of lunar dust

Surveyor-7 photographed a bright glow along the western lunar horizon one hour after local sunset. This horizon-glow (HG) must result from the forward scattering of sunlight by electrically charged dust grains which are electrostatically levitated 3 to 30 cm above rocks or surface irregularities located in the lunar terminator zone. Column densities the order of 50 grains/sq cm are produced. The mechanism by which the electrostatic field is generated is described, and the amount of surface material annually churned by this process is estimated.

Criswell, D. R.↗

Competition between cutaneous vasodilator and vasoconstrictor reflexes in man

A two-part experiment was carried out on seven men to determine whether skin will respond to increased neurogenic vasoconstrictor activity during heating. The latter was induced by lower body negative pressure of -50 mm Hg applied for 5 of each 15 min in 12 studies with constant, neutral skin temperature (32.2-34.4 C) in a 40-min control period and with skin temperature held at 38 C for 40-70 min. We conclude that during heating, skin retains the ability to vasoconstrict but that this vasoconstriction cannot completely override heat-induced vasodilatation.

Johnson, J. M.↗

The vapor pressure of iron pentacarbonyl

Vapor pressure measurements have been made on pure iron pentacarbonyl between +31 and -19 C. The experimental results may be expressed by the logarithm of pressure (mm Hg) to the base 10 equals -(2096.7 K/T) + 8.4959, which corresponds to a heat of vaporization for the liquid carbonyl of delta H ? (9.588 plus or minus 0.12) kcal/mole. This result confirms and extends the earlier measurements made by Trautz and Badstuebner between 0 and 140 C. The need for careful purification of commercially available iron pentacarbonyl is emphasized, particularly for establishing the correct vapor pressure below 45 C.

Gilbert, A. G.↗

NO and O3 measurements in the lower stratosphere from a U-2 aircraft

In situ measurements of nitric oxide and ozone were carried out at altitudes up to 21 km during two flights of a U-2 aircraft on Dec. 6 and 18, 1973, over the west coast of the United States. A chemiluminescent detector based on the luminescent reaction of nitric acid with excess ozone was used in nitric acid measurements. Ozone concentration measurements were based on the absorption of the Hg line at 2,537 A in the Hartley continuum. The results are compared with available data.

Loewenstein, M.↗

H2SO4-HNO3-H2O ternary system in the stratosphere

Estimation of the equilibrium vapor pressure over the ternary system H2SO4-HNO3-H2O to study the possibility of stratospheric aerosol formation involving HNO3. It is shown that the vapor pressures for the ternary system H2SO4-HNO3-H2O with weight composition around 70-80% H2SO4, 10-20% HNO3, 10-20% H2O at -50 C are below the order of 10 to the minus 8th mm Hg. It is concluded that there exists more than sufficient nitric acid and water vapor in the stratosphere to participate in ternary system aerosol formation at -50 C. Therefore, HNO3 should be present in stratospheric aerosols, provided that H2SO4 is also present.

Kiang, C. S.↗

Development of a six-man, self-contained carbon dioxide collection subsystem for spacecraft application

Life Systems, working with NASA, has developed an electrochemical, six-man, self-contained carbon dioxide concentrator subsystem (CX-6) designed to normally remove 13.2 lb/day of CO2 while maintaining the CO2 partial pressure (pCO2) of the cabin atmosphere at 3 mm Hg or less. The CX-6 was subjected to extensive parametric and endurance testing. The effects of operating conditions on CO2 removal and electrical efficiencies were determined, including effects of hydrogen (H2) flow rate, process airflow rate, pCO2, operating temperature and current density. A total of 209 days of operation was accumulated. The subsystem was designed with self-contained electronic control and monitoring instrumentation. The CX-6 was redesigned and repackaged into the CO2 collection subsystem for the air revitalization group of the space station prototype.

Schubert, F. H.↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with minus 196 C walls. Cold storage of a thruster was simulated and temperatures as low as minus 100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

Large neutron counters for supermonitors

Large neutron counters designed for the neutron supermonitor with an area of about 20 sq m are reported. Statistical accuracy of the counters is 0.1% per 2 hours. Dimensions: length--2 m; diameter--150 mm; pressure--200 mm Hg. The counters are filled with BF3 gas containing over 80% of B-10.

Blokh, Y. L.↗

LK39F1 S/N U-1 infrared detector

A multilayered (Hg,Cd)Te detector is described with three infrared bands. Nominal cut-off wavelengths for each band are as follows: (1) Channel 1 - 3 microns, (2) Channel 2 - 6 microns, and (3) Channel 3 - 11 microns. The multilayered detector is mounted in a Honeywell LK39 glass dewar. Accompanying the detector/dewar assembly is a three-channel preamplifier package capable of switching each detector to the single channel input of the HRB Singer Reconfax 4 Mark 4 Infrared Scanner.

Source record↗

The effects of exposure to LN2 temperatures and 2.5 suns solar radiation on 30-cm ion thruster performance

An experimental test program was developed to demonstrate all 30 cm Hg-ion bombardment thruster functions over the thermal environment of several proposed missions. A 30 cm thruster with grids dished 1.25 cm and instrumented with 31 thermocouples, was placed in a vacuum tank equipped with -196 C walls. Cold storage of a thruster was simulated and temperatures as low as -100 C were attained on the thruster. The thruster started successfully from these cold conditions. The thruster operating at both half and full beam power was exposed to 2.5 suns on axis solar simulation. Various thruster thermal configurations, used to simulate multiple thruster operation, were tested at the above conditions. The results of these tests are reported herein.

Mirtich, M. J.↗

Preflight studies on tolerance of pocket mice to oxygen and heat. I - Physiological studies

Tests were carried out on pocket mice to ascertain their tolerance to elevated oxygen pressures alone and to a combination of hyperoxia and heat in excess of that expected during the flight of the mice on Apollo XVII. The mice withstood oxygen partial pressures up to 12 psi at normal room temperature (24 C, 75 F) over a period of 7 days. A few mice previously exposed to increased PO2 died in the course of exposure to an oxygen pressure of 10 psi or 12 psi (517 mm or 620 mm Hg) for 13 d in ambient heat of 32 C (90 F). Supplemental vitamin E and physiological saline loading given prior to exposure had no apparent protective effect. The overall conclusion was that the pocket mice which were to go on Apollo XVII could readily survive the ambient atmosphere to which they would be exposed.

Leon, H. A.↗

Preflight studies on tolerance of pocket mice to oxygen and heat. IV - Observations on the brain

Experiments designed to ascertain the effects of oxygen at 8, 10, and 12 psi partial pressure on the brains of pocket mice (Perognathus longimembris) were carried out at room temperature (24 C, 75 F) and at 32 C (90 F). The animals exposed to 8-12 psi at 32 C had been in earlier KO2 oxygen tests. Five animals exposed either to 10 or 12 psi (517 mm or 620 mm Hg) O2 partial pressure at 32 C died during the course of the tests, possibly as a consequence of injury sustained by the earlier O2 partial pressure testing. Autopsy was not carried out. In the other 36 exposed animals, no pathological changes were observed in the brain. It is thus highly probable that oxygen pressures at the hyperbaric levels to which the pocket mice would be exposed during the Apollo XVII mission would not result in any lesions in the brain.

Bailey, O. T.↗

Comparison of techniques for measuring +Gz tolerance in man

Two objective methods and one subjective method for measuring +Gz tolerance (inertial vector in a head-to-foot direction) were compared on the human centrifuge. Direct eye-level blood pressure (Pa), blood flow velocity in the superficial temporal artery (Qta), and subjective visual symptoms were used to determine tolerance to rapid-onset acceleration (1 G/s) on the USAFSAM human centrifuge. Seven 'relaxed' subjects with extensive centrifuge experience were exposed to gradually increasing +Gz plateaus until the subject reported 100% loss of peripheral centrifuge gondola lights (PLL) and 50% loss of central light (CLD); viz., blackout. Zero forward Qta occurred 6 s (range 4-9 s) before subjective blackout and when mean eye-level blood pressure had reached 20 + or - 1 mm Hg (SE). The results of this study indicate that flow changes in the superficial temporal artery reflect flow changes in the retinal circulation during +Gz stress.

Krutz, R. W., Jr.↗

Measurements of NH3 absorption coefficients with a C-13/O-16/2 laser

Measurements of NH3 absorption coefficients are presented for several transitions of a C-13(O-16)2 laser for small concentrations of NH3(p less than 1 torr) for absorption lines broadened to 1 atm with N2. NH3 absorption coefficients were determined for laser transitions R(8)(920.2194 wavelengths/cm) to R(28)(933.8808 wavelengths/cm) of the 00 1 - (10 0,02 0)I band. The strongest absorption coefficient K = 36.09 + or - 1.43 per (atm-cm) was measured for the R(18) transition for the NH3 line, aQ(6,6), and is larger than has been found in any previous measurements with a CO2 laser. The dependence of K on total pressure was also obtained for select transitions, and the frequency separation between the R(18) laser transition and the neighboring NH3 line aQ(6,6) was determined to be 550 + or - 50 MHz. These results are significant for long path absorption monitoring of NH3 with CO2 lasers since the path length can be reduced by approximately 40% and for heterodyne detection of NH3 since the relative position of the laser transition to the NH3 absorption line is well within the bandpass of Hg-Cd-Te photomixers.

Allario, F.↗