Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

A study of target heating in low-energy ion-beam processing

A bonded thermocouple approach is employed to accurately determine semiconductor surface heating profiles as a function of energy, position, and gas species in a high-current low-energy ion beam etching system. The total beam current is kept at 200 mA and the extractor voltage at 300 V. It is found that the ionic species, the radial position in the ion beam, and the kinetic energy of the ions, all of which effect the ion current density, must be taken into account in recording the temperature rise of the bombarded surface. It is also noted that the occurrence of this temperature rise is dependent on the thermal contacts and heat sinking.

Ringel, S. A.↗

The development of a solar residential heating and cooling system

The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

Source record↗

Study of thermal energy storage using fluidized bed heat exchangers

The technical and economic feasibility of fluid bed heat exchangers (FBHX) for thermal energy storage (TES) in waste heat recovery applications is assessed by analysis of two selected conceptual systems, the rotary cement kiln and the electric arc furnace. It is shown that the inclusion of TES in the energy recovery system requires that the difference in off-peak and on-peak energy rates be large enough so that the value of the recovered energy exceeds the value of the stored energy by a wide enough margin to offset parasitic power and thermal losses. Escalation of on-peak energy rates due to fuel shortages could make the FBHX/TES applications economically attractive in the future.

Weast, T. E.↗

Study of component technologies for fuel cell on-site integrated energy systems

Heating, ventilation and air conditioning equipment are integrated with three types of fuel cells. System design and computer simulations are developed to utilize the thermal energy discharge of the fuel in the most cost effective manner. The fuel provides all of the electric needs and a loss of load probability analysis is used to ensure adequate power plant reliability. Equipment cost is estimated for each of the systems analyzed. A levelized annual cost reflecting owning and operating costs including the cost of money was used to select the most promising integrated system configurations. Cash flows are presented for the most promising 16 systems. Several systems for the 96 unit apartment complex (a retail store was also studied) were cost competitive with both gas and electric based conventional systems. Thermal storage is shown to be beneficial and the optimum absorption chiller sizing (waste heat recovery) in connection with electric chillers are developed. Battery storage was analyzed since the system is not electric grid connected. Advanced absorption chillers were analyzed as well. Recommendations covering financing, technical development, and policy issues are given to accelerate the commercialization of the fuel cell for on-site power generation in buildings.

Lee, W. D.↗

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Film Cooling Performance Prediction for Air and Supercritical CO 2

The current study explores the possibility of cooling the vanes and blades of a direct-fired sCO 2 turbine using film cooling. The operating conditions of a direct-fired sCO 2 cycle and thermophysical properties of the fluid at those conditions can alter the flow field characteristics of the coolant jet and its mixing with the mainstream. Very little information is present in the literature regarding the performance of film cooling geometries employing supercritical CO 2 . The objective of this study is to estimate the resulting film cooling effectiveness while also capturing the effects of the crossflow-to-mainstream velocity ratio on the coolant jet. Herein, a computational fluid dynamic model is used to study the coolant jet exiting a cylindrical hole located on a flat plate, with the coolant fed by an internal channel. Steady-state Reynolds-averaged Navier–Stokes equations were solved along with the (shear-stress transport) SST k–ω model to provide the turbulence closure. The operating conditions for the direct-fired sCO 2 turbine are obtained using an in-house Cooled Turbine Model. Numerical predictions revealed that the crossflow effects and jet lift-off were more pronounced in the case of sCO 2 when compared to air. Spatial distribution of flow field and cooling effectiveness are presented at different operating conditions.

30 DIRECT ENERGY CONVERSION↗

Heat transfer enhancement due to cold cap motion from bubbling in a waste glass melter

In this study, a computational fluid dynamics (CFD) model was developed to model the motion of a solid cold cap in a waste glass melter. Forced convection bubblers at the base of the melter release air into the molten glass, which forms large bubbles that travel upwards to the cold cap and augment heat transfer from the glass to the cold cap. The CFD model employs the Navier- Stokes equations to solve for the fluctuating flowfield using a rigid body motion dynamic fluid body interaction module. This allows for movement of the floating body in response to the bubbling forces calculated at each time step. Further, the heat flux delivered to the cold cap by the convective bubbling is studied as a function of the bubbling rate. Results for the moving cold cap are compared with the computed heat flux trends for a stationary cold cap. The heat flux delivered to the cold cap from the glass is 25% higher for the case with the moving cold cap. The heat flux was found to be proportional to v0.6 as opposed to v0.9 (where v is the normalized bubbling rate) for the stationary cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural heat pipe

When solar heat is absorbed through the structural support member it is fed directly to a heat pipe. Energy is transferred by heat pipe around to a cooler spot before it can find its way to the structure. This prevents local hot spots from occurring on the sun side and excessive heat leaks on the dark side.

Ollendorf, S.↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Compressed Gas Energy Storage Integrated with Combined Heat and Power Plant

A new energy storage technology, Comrpessed Gas Energy Storage (CGES), seeks to achieve low-cost, long-duration eenrgy storage by combining mature commercially-available technology (compressors, high-pressure gas storage, expander generators) and utilizing existing infrastructure for transportation and distribution of industrial gases. CGES utilizes existing compressors to transform electricity into potential energy (pressure), existing pipelines or underground storage to store said potential energy, and adds new expander generators at pressure reduction points in the networkm to recover part of the energy used in compression and transform it into electricity. By adapting itself to widely available existing infrastructure, CGES recovers energy that is otherwise wasted in the gas value chain, reduces the cost of new facilities, and avoids many of the development huddles typically associated with other long-duration energy storage technologies (e.g., Compressed Air Energy Storage, CAES). This paper discusses the performance and economics associated with CGES as a standalone project and in combination with a thermal power plant, based on a concept for integration of the technology over an existing lateral pipeline transporting natural gas to an 85 MW combined heat and power plant that feeds power to a grid with increasing share of renewable power generation.

03 NATURAL GAS↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Exergy Based Analysis for the Environmental Control and Life Support Systems of the International Space Station

When optimizing the performance of complex systems, a logical area for concern is improving the efficiency of useful energy. The energy available for a system to perform work is defined as a system's energy content. Interactions between a system's subsystems and the surrounding environment can be accounted for by understanding various subsystem energy efficiencies. Energy balance of reactants and products, and enthalpies and entropies, can be used to represent a chemical process. Heat transfer energy represents heat loads, and flow energy represents system flows and filters. These elements allow for a system level energy balance. The energy balance equations are developed for the subsystems of the Environmental Control and Life Support (ECLS) system aboard the International Space Station (ISS). The use of these equations with system information would allow for the calculation of the energy efficiency of the system, enabling comparisons of the ISS ECLS system to other systems as well as allows for an integrated systems analysis for system optimization.

Clem, Kirk A.↗

Machine learning-accelerated discovery of heat-resistant polysulfates for electrostatic energy storage

The development of heat-resistant dielectric polymers that withstand intense electric fields at high temperatures is critical for electrification. Balancing thermal stability and electrical insulation, however, is exceptionally challenging as these properties are often inversely correlated. A traditional intuition-driven polymer design approach results in a slow discovery loop that limits breakthroughs. Here we present a machine learning-driven strategy to rapidly identify high-performance, heat-resistant polymers. A trustworthy feed-forward neural network is trained to predict key proxy parameters and down select polymer candidates from a library of nearly 50,000 polysulfates. The highly efficient and modular sulfur fluoride exchange click chemistry enables successful synthesis and validation of selected candidates. A polysulfate featuring a 9,9-di(naphthalene)-fluorene repeat unit exhibits excellent thermal resilience and achieves ultrahigh discharged energy density with over 90% efficiency at 200 °C. Its exceptional cycling stability underscores its promise for applications in demanding electrified environments.

Li, He↗

Optimizing design and dispatch of a renewable energy system with combined heat and power

We embellish a mixed-integer program that prescribes a set of renewable energy, conventional generation, and storage technologies to procure, along with a corresponding dispatch strategy. Specifically, we add combined heat and power to this set. The model minimizes fixed and operational costs less incentives for the use of various technologies, subject to a series of component interoperability and system-wide constraints. The resulting mixed-integer linear program contains hundreds of thousands of variables and constraints. We demonstrate how to efficiently formulate and solve the corresponding instances such that we produce near-optimal solutions in minutes. A previous rendition of the model required hours of solution time for the same instances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Critical Review of Heat Pipe Experiments in Nuclear Energy Applications

This critical review provides heat pipe (HP) experimental data sets that contain pertinent information regarding nuclear technology that may be beneficial to researchers. Heat pipes have been shown to have a tremendously positive impact on nuclear technologies and will continue to become a more prevalent technology as more nuclear reactor concepts embrace this robust technology. Most previous reviews may focus on only a specific HP design or application, and some are backdated. Herein, this critical review extends previous efforts; integrates and summarizes previously reported HP experimental efforts; and provides updates with recently reported results in the literature for HPs in all nuclear-related applications, including space power (thermal radiators, core cooling, and electricity production), microreactors (emergency core cooling, hybrid control rods, and reactor core cooling), and HP involvement in other nuclear-related technologies (spent fuel pool cooling). The two main objectives of this critical review are (1) to facilitate the development of HP codes by outlining some of the existing experimental data sets to validate their codes and directing developers to these efforts and (2) to provide comprehensive information regarding the vast applicability of HPs used in the nuclear industry, including the theory of operation and limitations to supplement researchers in the development of new ideas for potential applications in nuclear-related technologies. The review clearly shows extensive and diverse experimental data sets for HPs developed under diverse testing conditions depending on the available nuclear application for validation purposes. Thus, this critical review is oriented to providing attention to the existing efforts rather than determining gaps in HP research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗