Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

IUE observations of the hot components in two symbiotic stars

Recent IUE observations reveal striking differences in the UV spectra of two symbiotic stars, R Aqr and RW Hya. RW Hya is found to be an unexpectedly intense source of UV radiation. The measurements reported demonstrate the presence of a hot component in each star, supporting the view that each is a binary system with a luminous red primary and a hot, subluminous companion. In one case, the hot companion manifests itself by exciting a compact nebulosity; in the other case the continuous spectrum of the hot star is directly detected, while the continuum of nebulosity excited by the hot star is detected at longer wavelengths.

Michalitsianos, A. G.↗

Chemical processes involved in the initiation of hot corrosion of B-1900 and NASA-TRW VIA

Sodium surface-induced hot corrosion of B-1900 and NASA-TRW VIA alloys at 900 C has been studied, with special attention to the chemical reactions during and immediately after the induction period. Thermogravimetric tests were run and data were obtained by chemical analysis of water soluble metal salts and of residual sulfate. Surface analyses of hot corroded samples were obtained by spectroscopic techniques (ESCA). A chemical mechanism for elucidating Na2SO4-induced hot corrosion is proposed indicating that hot corrosion is initiated by basic fluxing of the protective Al2O3 scale. The sequential, catastrophic corrosion results from molybdenum content. The self-sustaining feature is a consequence of the cyclic nature of the acidic fluxing. It is believed that the mechanism is applicable not only to laboratory results, but also to the practical problem of hot corrosion encountered in gas turbine engines.

Fryburg, G. C.↗

Endolithic microbial life in hot and cold deserts

Endolithic microorganisms (those living inside rocks) occur in hot and cold deserts and exist under extreme environmental conditions. These conditions are discussed on a comparative basis. Quantitative estimates of biomass are comparable in hot and cold deserts. Despite the obvious differences between the hot and cold desert environment, survival strategies show some common features. These endolithic organisms are able to 'switch' rapidly their metabolic activities on and off in response to changes in the environment. Conditions in hot deserts impose a more severe environmental stress on the organisms than in the cold Antarctic desert. This is reflected in the composition of the microbial flora which in hot desert rocks consist entirely of prokaryotic microorganisms, while under cold desert conditions eukaryotes predominate.

Friedmann, E. I.↗

Comparison of hot wire/laser velocimeter turbulence intensity measurements

The question of whether a random measure of particle velocities yields a good statistical estimate of the stationary condition of the turbulence flow field was investigated by comparing hot-wire and laser velocimeter turbulence intensity measurements. Great care was taken to insure that the instrument precision of both the laser velocimeter and hot wire was maximized. In this attempt to reduce the measurement uncertainties in the hot wire, direct digitization of the analog output signal was performed with point-by-point conversion to velocity through a spline fit calibration curve and the turbulence intensity function was calculated statistically. Frequent calibrations of the hot wire were performed using the laser velocimeter as the velocity standard to account for the presence of the small seed particles in the air flow and signal drift in the hot wire.

Meyers, J. F.↗

Long-term high-velocity oxidation and hot corrosion testing of several NiCrAl and FeCrAl base oxide dispersion strengthened alloys

Several oxide dispersion strengthened (ODS) alloys have been tested for cyclic, long-term, high gas-velocity resistance to oxidation at 1100 C and hot corrosion at 900 C. Both nominally Ni-16Cr-4Al and Fe-20Cr-4.5Al ODS alloys were subjected up to about 2500 cycles, where each cycle consisted of 1 hr in a hot, Mach 0.3 combusted gas stream followed by a 3-min quench in an ambient temperature, Mach 0.3 air blast. For comparison to existing technology, a coated superalloy was simultaneously tested. The ODS iron alloy exhibited clearly superior behavior, surviving 3800 oxidation and 2300 hot corrosion cycles essentially unscathed. While the ODS nickel alloys exhibited adequate oxidation resistance, the long-term hot corrosion resistance could be marginal, since the best life for such alloys under these conditions was only about 1100 cycles. However, the hot corrosion resistance of the ODS Ni-base alloys is excellent in comparison to that of traditional superalloys.

Lowell, C. E.↗

Characterization of particles in the Langley 0.3 meter transonic cryogenic tunnel using hot wire anemometry

Hot wire anemometry was used to identify the nature of particles reportedly observed during free stream velocity measurements in the Langley 0.3-meter transonic cryogenic tunnel using a Laser Doppler Velocimeter. Since the heat-transfer process from the hot wire depends on the thermal conductivity and sticking capability of the particles, it was anticipated that the hot wire anemometer response would be affected differently upon impaction by liquid droplets and solid aerosols in the test gas stream. Based on the measured time response of the hot-wire anemometer in the cryogenic tunnel operated in the 0.3-0.8 Mach number range, it is concluded that the particles impacting the hot wire are liquid in nature rather than solid aerosols. It is further surmised that the liquid aerosols are unevaporated liquid nitrogen droplets used for cooling the tunnel test gas.

Singh, J. J.↗

Hot spot heat transfer - Its application to Venus and implications to Venus and earth

Using a model that gives a relationship between surface elevation, lithospheric thickness, and heat flux, the hot spot heat loss mechanism is tested for Venus. The mechanism is found to readily explain the predicted heat loss of the planet with a modest number of hot spots (of the order of 35). Lithospheric thickness variations can explain approximately 93 percent of the mapped topography of Venus. Above a radius of 6053 km, additional compensation is required, and this can be effected by incorporating a variable thickness crust into the model. If it is assumed that the crust is generated on the crests of the hot spots, probably by processes associated with volcanism, the model is consistent with nearly 99 percent of the mapped topography of Venus. In addition, the model is basically consistent with available gravity data and interpretations that suggest compensated topography and great depths of compensation (100-1000 km) for the midlatitudes of the planet. It is thought that the approximately 1 percent of the topography not explained by hot spot crustal generation is compensated at a shallower depth primarily by variations in crustal thickness that are not directly related to hot spot volcanism.

Morgan, P.↗

The use of hot-wire anemometry in transonic periodic flow

The unsteady wake profiles of an airfoil with an oscillating flap were measured in the NASA Ames 11 x 11-foot transonic wind tunnel. Laser Doppler Velocimetry (LDV) and holography techniques were used in limited region where optical accessability is available. X-hot-film wire was used to measure the wake profiles in the complete region to obtain magnitude and direction of the flow. A thorough calibration was carried out to determine the sensitivity coefficients of the hot-wire in three different tunnels at transonic speeds. A calculation procedure is established to resolve the hot-wire signals at transonic speeds and applied in the measurements of steady and periodic wake profiles. The effect of flow incidence on the hot-wire signals is evaluated and incorporated in the analyses. Typical hot-wire results are compared with the results of LDV, holography and pitot-static tube embedded with Kulite transducers.

Bodapati, S.↗

Effect of hot electrons on the polar wind

A semikinetic model is used to describe the steady state collisionless flow of H(+), O(+), and electrons along diverging geomagnetic field lines in the high-latitude topside ionosphere. The effect that hot electron populations have on the polar wind is emphasized. Several such populations are considered, including the polar rain, polar showers, and polar squall. Hot electron densities and temperatures are calculated from the characteristic energy and flux measurements. The results indicate that the hot/cold electron temperature ratio varies from 10 to 10,000 and that the hot/cold electron density ratio varies from 0.001 to 0.1 at the baropause. For higher hot electron temperatures and a greater percentage of hot electrons, there is a discontinuity in the kinetic solution, which indicates the presence of a sharp transition corresponding to a contact surface between the hot and cold electrons. Along this surface, a double-layer potential barrier exists which reflects the cold ionospheric electrons and prevents their penetrations to higher altitudes.

Barakat, A. R.↗

Accuracy Of Hot-Wire Anemometry In Supersonic Turbulence

Sensitivity of hot-wire probe compared to laser-induced-florescence measurements. Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF). Because LIF provides spatially and temporally resolved data on temperature, density, and pressure, provides independent means to determine responses of hot-wire anemometers to these quantities.

Logan, Pamela↗

Role of hot oxygen in Venusian ionospheric ion energetics and supersonic antisunward flow

The column heating rate of the dayside Venus ionospheric ion gas resulting from transfer of energy from the hot oxygen component of the neutral atmosphere is estimated and found equal to that which, when inserted into ionospheric models at the ionopause, raises the calculated temperature to measured values. The transfer of energy is effected through resonant charge exchange between the relatively cold ionospheric O(+) ions and the hot oxygen neutrals. The hot oxygen density in the nightside hemisphere does not appear to play a significant role in the nightside ion energetics. The hot oxygen neutral gas flowing across the terminator from its dayside source to its nightside sink will exchange momentum with the antisunward flowing ionospheric gas. Although the flow rate of hot oxygen can be estimated only crudely, the estimated rate of deposition and absorption is comparable to that produced by the plasma pressure and should be included in numerical studies of the terminator ionospheric wind.

Knudsen, William C.↗

Method of measuring cross-flow vortices by use of an array of hot-film sensors

The invention is a method for measuring the wavelength of cross-flow vortices of air flow having streamlines of flow traveling across a swept airfoil. The method comprises providing a plurality of hot-film sensors. Each hot-film sensor provides a signal which can be processed, and each hot-film sensor is spaced in a straight-line array such that the distance between successive hot-film sensors is less than the wavelength of the cross-flow vortices being measured. The method further comprises determining the direction of travel of the streamlines across the airfoil and positioning the straight-line array of hot film sensors perpendicular to the direction of travel of the streamlines, such that each sensor has a spanwise location. The method further comprises processing the signals provided by the sensors to provide root-mean-square values for each signal, plotting each root-mean-square value as a function of its spanwise location, and determining the wavelength of the cross-flow vortices by noting the distance between two maxima or two minima of root-mean-square values.

Agarwal, Aval K.↗

Interaction of field-aligned cold plasma flows with an equatorially-trapped hot plasma - Electrostatic shock formation

Effects of equatorially trapped hot plasma on the highly supersonic cold-plasma flow occurring during early stage plasmaspheric refilling are studied by means of numerical simulations. It is shown that the equatorially trapped hot ions set up a potential barrier for the cold ion beams and facilitate formation of electrostatic shocks by reflecting them from the equatorial region. Simulations with and without the hot plasma show different flow properties; the formation of electrostatic shocks occur only in the former case. The simulation with the hot plasma also reveals that the magnetic trapping in conjunction with the evolution of the electrostatic potential barrier produces ion velocity distribution functions consisting of a cold core and a hot ring in the perpendicular velocity. Such a distribution function provides a source of free energy for equatorial waves. The corresponding electron population is warm and field-aligned.

Singh, Nagendra↗

Ultraviolet and optical studies of binaries with luminous cool primaries and hot companions. IV - Further IUE detections

We have obtained IUE spectra for 31 middle and late-type giant and supergiant stars whose TD-1 fluxes or ground-based spectra indicate the presence of a hot component, or whose radial velocities indicate an unseen component. Stellar components earlier than type F1 were detected in 22 cases. While 20 of the hot secondaries are seen weakly in optical spectra, two are UV discoveries: HD 58134 and HD 183864. The hot companions are classified accurately by temperature class from their far-UV spectra. The interstellar extinction of each system and the relative luminosities of the components are derived from the UV and optical fluxes, using a new grid of UV intrinsic colors for hot dwarfs. We find that many giant stars apparently have companions which are too hot and hence too luminous for consistency with the primary's spectral classification.

Parsons, Sidney B.↗

Experimental Study of Ignition by Hot Spot in Internal Combustion Engines

In order to carry out the contemplated study, it was first necessary to provide hot spots in the combustion chamber, which could be measured and whose temperature could be changed. It seemed difficult to realize both conditions working solely on the temperature of the cooling water in a way so as to produce hot spots on the cylinder wall capable of provoking autoignition. Moreover, in the majority of practical cases, autoignition is produced by the spark plug, one of the least cooled parts in the engine. The first procedure therefore did not resemble that which most generally occurs in actual engine operation. All of these considerations caused us to reproduce similar hot spots at the spark plugs. The hot spots produced were of two kinds and designated with the name of thermo-electric spark plug and of metallic hot spot.

Serruys, Max↗

Resistance of Silicon Nitride Turbine Components to Erosion and Hot Corrosion/oxidation Attack

Silicon nitride turbine components are under intensive development by AlliedSignal to enable a new generation of higher power density auxiliary power systems. In order to be viable in the intended applications, silicon nitride turbine airfoils must be designed for survival in aggressive oxidizing combustion gas environments. Erosive and corrosive damage to ceramic airfoils from ingested sand and sea salt must be avoided. Recent engine test experience demonstrated that NT154 silicon nitride turbine vanes have exceptional resistance to sand erosion, relative to superalloys used in production engines. Similarly, NT154 silicon nitride has excellent resistance to oxidation in the temperature range of interest - up to 1400 C. Hot corrosion attack of superalloy gas turbine components is well documented. While hot corrosion from ingested sea salt will attack silicon nitride substantially less than the superalloys being replaced in initial engine applications, this degradation has the potential to limit component lives in advanced engine applications. Hot corrosion adversely affects the strength of silicon nitride in the 850 to 1300 C range. Since unacceptable reductions in strength must be rapidly identified and avoided, AlliedSignal and the NASA Lewis Research Center have pioneered the development of an environmental life prediction model for silicon nitride turbine components. Strength retention in flexure specimens following 1 to 3300 hour exposures to high temperature oxidation and hot corrosion has been measured and used to calibrate the life prediction model. Predicted component life is dependent upon engine design (stress, temperature, pressure, fuel/air ratio, gas velocity, and inlet air filtration), mission usage (fuel sulfur content, location (salt in air), and times at duty cycle power points), and material parameters. Preliminary analyses indicate that the hot corrosion resistance of NT154 silicon nitride is adequate for AlliedSignal's initial engine applications. Protective coatings and/or inlet air filtration may be required to achieve required ceramic component lives in more aggressive environments.

Strangmen, Thomas E.↗

Hot-wire calibration in subsonic/transonic flow regimes

A different approach for calibrating hot-wires, which simplifies the calibration procedure and reduces the tunnel run-time by an order of magnitude was sought. In general, it is accepted that the directly measurable quantities in any flow are velocity, density, and total temperature. Very few facilities have the capability of varying the total temperature over an adequate range. However, if the overheat temperature parameter, a(sub w), is used to calibrate the hot-wire then the directly measurable quantity, voltage, will be a function of the flow variables and the overheat parameter i.e., E = f(u,p,a(sub w), T(sub w)) where a(sub w) will contain the needed total temperature information. In this report, various methods of evaluating sensitivities with different dependent and independent variables to calibrate a 3-Wire hot-wire probe using a constant temperature anemometer (CTA) in subsonic/transonic flow regimes is presented. The advantage of using a(sub w) as the independent variable instead of total temperature, t(sub o), or overheat temperature parameter, tau, is that while running a calibration test it is not necessary to know the recovery factor, the coefficients in a wire resistance to temperature relationship for a given probe. It was deduced that the method employing the relationship E = f (u,p,a(sub w)) should result in the most accurate calibration of hot wire probes. Any other method would require additional measurements. Also this method will allow calibration and determination of accurate temperature fluctuation information even in atmospheric wind tunnels where there is no ability to obtain any temperature sensitivity information at present. This technique greatly simplifies the calibration process for hot-wires, provides the required calibration information needed in obtaining temperature fluctuations, and reduces both the tunnel run-time and the test matrix required to calibrate hotwires. Some of the results using the above techniques are presented in an appendix.

Nagabushana, K. A.↗

The onset of Wolf-Rayet wind outflow and the nature of the hot component in the symbiotic nova PU Vulpecula

We have analyzed temporal variations in the far ultraviolet He II (1640), Si IV (1393, 1402), and C IV (1548, 1550) line profiles in eight high dispersion, International Ultraviolet Explorer Short Wavelength Prime spectra of the symbiotic nova PU Vul by comparatively examining these profiles on a common velocity scale. We see clear evidence of the onset of a Wolf-Rayet-like wind outflow from the bloated, contracting white dwarf hot component with terminal velocity of approximately equals -550 to -600 km/s. We have quantitatively analyzed the complicated He II (1640) emission region for the first time and show that the discrete absorption features seen in the He II region occur at precisely the same velocites in each spectrum, thus demonstrating that the absorbing source is steady and not affected by any orbital motion. We demonstrate that there is an underlying He II wind emission feature whose true shape is hidden by superposed absorption due to the foreground red giant wind flowing in front of the white dwarf and abscuring the white dwarf's wind outflow. We present synthetic spectra of He II emission behind an absorbing slab with u = 20 km/s, T = 5000 K, and column densities in the range N = 1 x 10(exp 22) and 1 x 10(exp 23)/sq cm which explain these absorptions. Our analysis of the Si IV and C IV resonance doublets, in velocity space, reveal temporal variations in the profile between 1987 and 1991 with the emergence of clear P Cygni profiles in Si IV by 1990. A nebular emission feature in C III 1909 also appears in the most recent spectra (e.g., SW42538H) while it was absent or extremely weak in the earliest spectra (e.g., SW36332H), thus strengthening evidence that the nebular emission, as seen in permitted and semiforbidden lines, intensities in step with the onset of the hot, fast, wind outflow. We also report the first detection of narrow interstellar (circumbinary shell?) absorption lines near -1 km/s, most strongly in Al III (1854, 1862) and Si IV (1392, 1402). We have carried out a rough quantitative analysis of the He II wind emission by using the theoretical He II Wolf-Rayet profiles of Hamann & Schmutz (1987). We obtain a lower limit to the He II net emission equivalent width of approximately 1 A, a hot component temperature in the range 25,000 to 35,000 K, a hot component radius in the range 5 solar radius to 30 solar radius, a maximum wind velocity of approximately equals -600 km/s and a rough upper limit to the mass-loss rate of less than 1 x 10(exp -5) solar mass/yr. To our knowledge, this is the first quantitative wind analysis, albeit crude, to be carried out for the hot component of a symbiotic nova or symbiotic variable.

Sion, Edward M.↗