Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Effect of impurities on hydrogen defect stability and migration barrier in yttrium dihydride crystal

The impurity or alloying atoms in YH 2 can alter the local electronic structure and so the hydrogen defect stability, as well as the H migration barrier energy. Thus, DFT calculations were employed to determine the effect of foreign elements from alkali and alkaline earth metals to transition metals and one critical impurity element, O, on H vacancy stability and retention characteristics in YH2. Results revealed that alloying elements act as hydrogen vacancy sinks by reducing the vacancy formation energy at neighboring sites. The implantation of non-magnetic foreign elements (s1, s2, and d10 valence electrons) in hydrogen energy landscape was calculated to be minor; while the hydrogen vacancy formation energy was reduced from 1.37 eV to 1.00 eV, the migration energy barrier of hydrogen was increased from 0.87 eV to 1.15 eV for non-magnetic foreign elements. The migration energy barrier monotonically decreased with increasing d-shell occupancy, reaching as low as 0.4 eV for Cr, Mo(d4), and Fe (d4). Alloying with late transition metals (d8 and d9) moderately impacted the hydrogen vacancy formation. Finally, it was found to be O addition into the YH 2- lattice did not alter the energy landscape of hydrogen vacancies. Since alloyed YH 2 has not been studied extensively, this study provides an atomistic understanding how alloying elements and impurities trap vacancies and affects hydrogen mobility YH 2 . Meanwhile, the main findings of this study may serve as guidelines for introducing alloying elements in ZrH 2 as well.

08 HYDROGEN↗

Modeling of hydrogen liquefaction using magnetocaloric cycles with permanent magnets

Hydrogen (H 2 ) is promising alternative to replace fossil fuels, but its transport and storage has been challenging. As H 2 fuel cell vehicles are gaining traction, the infrastructure for storing large amounts of liquid H 2 is needed. However, liquid H 2 would suffer from boil-off loss, and traditional vapor compression refrigeration systems would not be able to economically recover the lost H 2 due to the low efficiencies at cryogenic temperature. Magnetocaloric (MC) refrigeration systems could possess much higher coefficient of performance (COP) at cryogenic temperature compared to the vapor compression ones. Previous work on cryogenic MC systems, however, have only focused on large scale applications which use superconducting magnets to provide a large magnetic field but are prohibitively expensive to operate for small scale applications, such as that of a H 2 refilling station. In this work, we model the performance of a MC refrigeration cycle using 1-Tesla permanent magnets for H 2 liquefaction, with the objective of cooling H 2 from 80 K (using liquid nitrogen as the heat sink) to 20 K (boiling point of hydrogen). We evaluate main performance metrics including the total work input to the refrigeration system, COP, total MCM mass in the system, and total volume of the permanent magnets, etc. Our modeling results indicate that such a permanent magnet-based MC cooling system is feasible for small-scale H 2 liquefaction, with projected COP values significantly higher than those of vapor compression systems. In conclusion, this work provides design guidelines for future experimental efforts on permanent magnet MC cooling systems for cryogenic cooling.

08 HYDROGEN↗

Modeling of Tumor Control Probability in Stereotactic Body Radiation Therapy for Adrenal Tumors

Stereotactic body radiation therapy (SBRT) in the management of adrenal metastases is emerging as a well-tolerated, effective method of treatment for patients with limited metastatic disease. SBRT planning and treatment utilization are widely variable, and publications report heterogeneous radiation dose fractionation schemes and treatment outcomes. The objective of this analysis was to review the current literature on SBRT for adrenal metastases and to develop treatment guidelines and a model for tumor control probability of SBRT for adrenal metastases based on these publications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety Margins for the Delineation of the Left Anterior Descending Artery in Patients Treated for Breast Cancer

Cardiac toxicity after breast cancer (BC) radiation therapy is partly due to the large radiation doses to coronary arteries. The left anterior descending artery (LAD) is particularly exposed. A first step in achieving robust dose constraints to the LAD during treatment planning is homogeneous delineation based on guidelines. LAD delineation can be problematic due to heart movements. The aim of the study was to establish a safety margin for delineation of the LAD in patients with BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response Relationship in Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma: A Pooled Analysis of an Asian Liver Radiation Therapy Group Study

Despite the worldwide implementation of stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC), there is a lack of consensus guideline on prescription dose. Herein, this multinational study aimed to investigate the effects of the prescribed radiation dose on oncologic outcomes of SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Executive Summary of the American Radium Society Appropriate Use Criteria for Radiation Treatment of Node-Negative Muscle Invasive Bladder Cancer

Definitive radiation therapy (RT), with or without concurrent chemotherapy, is an alternative to radical cystectomy for patients with localized, muscle-invasive bladder cancer (MIBC) who are either not surgical candidates or prefer organ preservation. We aim to synthesize an evidence-based guideline regarding the appropriate use of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Radiation Therapy for Bone Metastases, 2015 to 2017: Choosing Wisely in the Era of Complex Radiation

Guidelines recommend short-course (≤10 fractions) external-beam radiation therapy (EBRT) for bone metastases. Stereotactic body radiation therapy (SBRT) may also improve outcomes; however, routine use is not recommended outside clinical trials. We assessed national radiation therapy trends in complex techniques for bone metastases and associated expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exercise Therapy and Radiation Therapy for Cancer: A Systematic Review

Exercise therapy (ET) is shown to improve toxicity and surrogates of survival for patients receiving chemotherapy. Current National Comprehensive Cancer Network (NCCN) guidelines lack recommendations for concurrent radiation therapy (RT) and ET. The main objective was to determine the impact of concurrent ET + RT with respect to (1) acceptability, feasibility, safety; and (2) to demonstrate how incorporating ET in cancer treatment can enhance patient-reported outcomes (PROs) and physical function—defined as strength or exercise capacity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Recommendations on Reirradiation by Intensity Modulated Radiation Therapy for Locally Recurrent Nasopharyngeal Carcinoma

Reirradiation for locally recurrent nasopharyngeal carcinoma (NPC) is challenging because prior radiation dose delivered in the first course is often close to the tolerance limit of surrounding normal structures. A delicate balance between achieving local salvage and minimizing treatment toxicities is needed. However, high-level evidence is lacking because available reports are mostly retrospective studies on small series of patients. Pragmatic consensus guidelines, based on an extensive literature search and the pooling of opinions by leading specialists, will provide a useful reference to assist decision-making for these difficult decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Relation of Radiation Therapy Quality With Toxicity and Survival in LAP07 Phase 3 Trial for Locally Advanced Pancreatic Carcinoma

The LAP07 multicenter randomized study assessed whether chemoradiation therapy increases overall survival versus continuation chemotherapy in patients whose locally advanced pancreatic cancer was controlled after 4 months of induction chemotherapy. This analysis investigated whether failure to adhere to radiation therapy (RT) guidelines influenced survival and toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Mediastinal B Cell Lymphoma in the Positron-Emission Tomography Era Executive Summary of the American Radium Society Appropriate Use Criteria

Primary mediastinal B cell lymphoma (PMBCL) is a highly curable subtype of non-Hodgkin lymphoma that is diagnosed predominantly in adolescents and young adults. Consequently, long-term treatment-related morbidity is critical to consider when devising treatment strategies that include different chemoimmunotherapy strategies with or without radiation therapy. Furthermore, adaptive approaches using the end-of-chemotherapy (EOC) positron emission tomography (PET)/computed tomography (CT) scanning may help to determine which patients may benefit from additional therapies. We aimed to develop evidence-based guidelines for treating these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gantry-Based 5-Fraction Elective Nodal Irradiation in Unfavorable-Risk Prostate Cancer: Outcomes From 2 Prospective Studies Comparing SABR Boost With MR Dose-Painted HDR Brachytherapy Boost

Guidelines from the American Society of Clinical Oncology and Cancer Care Ontario recommend brachytherapy boost for patients with intermediate-risk or high-risk prostate cancer. SABR is an emerging technique for prostate cancer, but its use in high-risk disease is limited. Efficacy, toxic effects, and quality of life (QoL) were compared in patients treated on 2 prospective protocols that used SABR boost or magnetic resonance–guided high-dose-rate brachytherapy (HDR-BT) boost with 6 to 18 months of androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineered Biosynthesis of Alkyne-Tagged Polyketides by Type I PKSs

Polyketides produced by modular polyketide synthases (PKSs) are important small molecules widely used as drugs, pesticides, and biological probes. Tagging these polyketides with a clickable functionality enables the visualization, diversification, and mode of action study through bio-orthogonal chemistry. We report the de novo biosynthesis of alkyne-tagged polyketides by modular type I PKSs through starter unit engineering. Specifically, we use JamABC, a terminal alkyne biosynthetic machinery from the jamaicamide B biosynthetic pathway, in combination with representative modular PKSs. We demonstrate that JamABC works as a trans loading system for engineered type I PKSs to produce alkyne-tagged polyketides. In addition, the production efficiency can be improved by enhancing the interactions between the carrier protein (JamC) and PKSs using docking domains and site-directed mutagenesis of JamC. This work thus provides engineering guidelines and strategies that are applicable to additional modular type I PKSs to produce targeted alkyne-tagged metabolites for chemical and biological applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗