Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Plasma-Assisted Pre-Chamber Ignition System for Highly Dilute Stoichiometric Heavy-Duty Natural Gas Engines (Final Technical Report)

This project explored advanced ignition technologies to significantly enhance efficiency and reduce operating costs for heavy-duty natural gas engines operating at stoichiometric conditions, while meeting ultra-low NOx emission standards. The main goal was to develop and validate a plasma-assisted pre-chamber ignition system that could deliver at least a 2% increase in brake thermal efficiency (BTE) and a 4% decrease in total cost of ownership (TCO) compared to a typical multi-cylinder engine with three-way catalyst aftertreatment, ensuring compatibility with the expected 2027 EPA/CARB regulations. In the first half of the project, the research team concentrated on developing and testing plasma-assisted pre-chamber ignition using nanosecond pulsed discharges. Extensive experiments were conducted in an optically accessible rapid-compression and expansion machine, a constant-volume chamber, and an optical single-cylinder engine. Experiments were coupled with CFD simulations. The work produced unique insights into pre-chamber flame formation, jet ignition, dilution effects, and flame quenching at pressures, temperatures, and dilution levels relevant to engines. Although plasma-assisted ignition showed promise in controlled lab settings, the research also identified fundamental and practical challenges when applying this technology to real engine conditions. Midway through the project, a crucial pivot was made, guided by three key findings. First, the power electronics required for nanosecond plasma discharges were found to be too costly for commercial use, undermining the project’s cost-of-ownership goals. Second, nanosecond plasma ignition was highly sensitive to turbulent flow in the pre-chamber, resulting in lower ignition reliability than traditional spark under engine-like conditions. Third, achieving a truly diffuse low-temperature plasma at high pressures near top dead center was not possible, reducing the anticipated chemical enhancement benefits. These results collectively suggested that continuing with plasma-assisted ignition was unlikely to meet both efficiency and cost objectives. In response, the project shifted focus to a more realistic approach: enhancing traditional spark-based pre-chamber ignition with significantly less spark energy. Using insights gained earlier in the project, the team redesigned the pre-chamber to maintain high dilution tolerance and quick combustion, even with lower ignition energy. Testing confirmed that with optimized pre-chamber design and combustion timing, a lower-energy spark could reliably ignite highly diluted stoichiometric mixtures, reduce burn time, and boost thermal efficiency. Final engine testing and techno-economic analysis verified that this revised approach successfully achieved the project goals. The optimized pre-chamber ignition system provided over a 2% increase in calculated brake thermal efficiency compared to the baseline engine. Notably, the lower ignition energy and simplified hardware reduced component stress, extended maintenance intervals, and lowered the total cost of ownership. When used with stoichiometric operation and traditional three-way aftertreatment, the system remained compatible with near-zero NOx emissions targets without increasing cost or complexity in the emissions control system. In summary, although the project deviated from its initial plasma-assisted ignition idea, the work produced a more practical and commercially viable solution. The results show that precisely optimized, low-energy pre-chamber spark ignition can significantly improve efficiency and reduce overall ownership costs for heavy-duty natural gas engines. This directly aligns with DOE goals for cleaner, more efficient, and cost-effective transportation technologies.

03 NATURAL GAS↗

Biological Treatment of Flue Gas Desulfurization Wastewater

In order to limit and mitigate the environmental impacts associated with coal combustion, flue gas desulfurization (FGD) systems have been put into place to reduce the release of contaminates. The main constituent targeted by FGD systems is sulfur oxide gasses (SOx). While FGD systems have been able to achieve high removal rates of SOx gasses, the wastewater effluent requires treatment before release back into the environment. The release of wastewater is heavily regulated by the U.S. Environmental Protection Agency (EPA) and their effluent guideline limitations rule (ELG). The ELG rule set new limits on discharges containing constituents such as selenium, nitrogenous species, mercury, and arsenic in the effluent. This report seeks to give background on abiotic removal methods as well as highlight the most important issues when utilizing biological treatment to treat the FGD wastewater for the constituents of interest mentioned. This report also seeks to discuss the issues of foaming which can occur during biological treatment.

01 COAL, LIGNITE, AND PEAT↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

Given the steady growth in world population and the ever-increasing fresh water demand, the only sustainable water supply option is desalination. Conceptually, desalination is very simple - just separate dissolved salts from water. While desalination research programs have existed since the 1960s and have resulted in a multitude of approaches, realizing affordable desalination has proven to be a challenge. Our goal is to meet this challenge using low cost heat sources to drive a liquid-discharge-free desalination process that can be co-mingled with the extraction of economically valuable co-products. High temperatures and pressures will be used to manipulate water’s properties, such as the dielectric constant, and hence its ability to solvate ions. Selective precipitation/recovery of valuable metal co-products creates new revenue streams (i.e., cost offsets). We will develop the scientific understanding necessary to control salt precipitation from supercritical seawater, inland brines, and water commonly co-produced with oil and gas. Atomistic simulations will be used to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

58 GEOSCIENCES↗

Dielectric strength of noble and quenched gases for high pressure time projection chambers

Abstract Dielectric breakdown strength is one of the critical performance metrics for pure gases and gas mixtures used in large, high pressure gas time projection chambers. In this paper we experimentally study dielectric breakdown strengths of several important time projection chamber working gases and gas-phase insulators over the pressure range 100 mbar to 10 bar, and gap sizes ranging from 0.1 to 10 mm. Gases characterized include argon, xenon, CO $$_2$$ 2 , CF $$_4$$ 4 , and mixtures 90-10 argon-CH $$_4$$ 4 , 90-10 argon-CO $$_2$$ 2 and 99-1 argon-CF $$_4$$ 4 . We develop a theoretical model for high voltage breakdown based on microphysical simulations that use electron swarm Monte Carlo results as input to Townsend- and Meek-like discharge criteria. This model is shown to be highly predictive at high pressure, out-performing traditional Paschen–Townsend and Meek–Raether models significantly. At lower pressure-times-distance, the Townsend-like model is an excellent description for noble gases whereas the Meek-like model provides a highly accurate prediction for insulating gases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data and scripts associated with "Coupled primary production and respiration in a large river contrasts with smaller rivers and streams."

This data package is associated with the publication "Coupled primary production and respiration in a large river contrasts with smaller rivers and streams." in review at Limnology and Oceanography (Roley et al. 2023). This study focuses on understanding ecosystem metabolism for the Hanford Reach of the Columbia River in Washington state, a free-flowing stretch with a substantial discharge. Large rivers have been overlooked compared to small and medium rivers due to the challenges associated with measurements. Our study presents novel ways to address these challenges and highlights that metabolism patterns in large rivers differ from those observed in small-medium rivers and requires the application of knowledge and tools beyond those implemented for smaller rivers.This data package includes the data and R scripts for the analyses described in Roley et al. 2023. It includes dissolved oxygen and temperature data from a dissolved oxygen HOBO sensor, light data collected from the National Solar Radiation Database (https://nsrdb.nrel.gov/) and hydrologic variables estimated from the MASS-1 model (Niehus et al.; 2014). It also includes metabolism estimates (gross primary production, ecosystem respiration, and net ecosystem production) estimated via streamMetabolizer (Appling et al.; 2018). All analyses in the paper can be replicated with these data and scripts.The data package is comprised of one main data folder. The folder includes (1) file-level metadata (flmd); (2) a data dictionary (dd) for each data file; (3) data files; and (4) R scripts for metabolism estimates and data analysis. All files are .R, .csv, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

Design of a separate effects MiniFuel irradiation experiment investigating microstructure evolution in high burnup UO 2

The microstructural evolution of UO 2 fuel pellets during commercial operation in light water reactors (LWRs) is known to vary significantly across the pellet radius due to spatial variations in local temperature and burnup. The primary obstacle to extending LWR refueling cycles to 24-month intervals is the susceptibility of certain high burnup fuel microstructures to fuel fragmentation, relocation, and dispersal (FFRD) during a loss of coolant accident (LOCA). Although FFRD of the high burnup structure in the rim region of a pellet is well studied, the fine fragmentation that has been observed in a second region, near the midradius of the pellet (termed the “dark zone”) following mock LOCA testing of high burnup commercial fuel rods is less understood. This paper describes the design, analysis, and execution of a separate effects MiniFuel irradiation experiment that aims to identify the specific temperature and burnup regimes under which FFRD-susceptible dark zone microstructures form. The small disc specimens (3 mm diameter by ∼0.3 mm thick) enable more precise control of the relatively uniform temperature and burnup conditions. A total of 42 specimens were fabricated with typical LWR fuel densities (∼96%–98% of theoretical density) and grain sizes (∼12 μm) and are being irradiated over a range of temperatures (600°C–1000°C) and discharge burnups (50–72 MWd/kg-U) that bound the midradius region of high burnup LWR fuel. Fuel specimens with identical 235 U enrichments were inserted in two irradiation locations in the High Flux Isotope Reactor and are currently undergoing irradiation to further evaluate the impact of rate effects (fission rate, time at temperature) on the microstructural evolution. The fuel fabrication and the thermal and neutronic simulations used for designing the experiment are detailed in this paper. A secondary objective of the experiment is to observe fission gas release (FGR) under the various irradiation conditions, and this work provides first-order predictions of FGR from all fuel specimens. The insights gained from these experiments will inform future high burnup core designs that could minimize the formation of susceptible microstructures and ultimately enable 24-month refueling cycles while minimizing the fraction of the fuel susceptible to FFRD.

FFRD↗

Observations Show Charge Density of Volcanic Plumes is Higher Than Thunderstorms

We analyze slow electric field change and lightning mapping measurements to provide insight into the characteristics of volcanic lightning and the associated implications on charging processes and the charge structure of a Vulcanian eruption plume. Data were obtained during a multi-instrumental field campaign at Sakurajima volcano in 2015 when the Showa crater was active. We combine the electric field change and lightning mapping data from one explosive eruption on June 6, 2015 to identify individual flashes. From this, we interpret the flash type and polarity. In addition, the long-time constant of the electric field change instrument allowed measurement of the quasi-static field associated with charge separation in the eruption plume. We find that both intracloud and cloud-to-ground discharges occurred, and the polarity of cloud-to-ground discharges were all negative. The quasi-static field measurement showed the plume carried a net negative charge. We calculate both the total charge transferred by cloud-to-ground discharges and the net charge density of the eruption plume. We find that cloud-to-ground discharges transfer an average of –0.41C per flash and the net charge density was –33C/ km 3 . Here, the percent error is at least 200%, due to uncertainty in the antenna gain. We show that these estimates are consistent with lightning that is 100 m in length. Further, the average flash rate during the first 8 s following the onset of eruption was five flashes per second. After that time, the flash rate abruptly decreased, which may be related to the end of gas-thrust forcing.

58 GEOSCIENCES↗

Techno-Economic Analysis of a Cryogenic Flux Capacitor for Grid Storage

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. The high energy density of CFC-stored hydrogen allows long durations of storage, such as daily to monthly cycling, which corresponds to approximately 10 to 100 hours of duration, respectively. The techno-economic analysis examines different types of hydrogen storage for commercial viability. The assessment includes the use of hydrogen blended with natural gas in a combined cycle gas turbine. The study provides results for a range of blends from 100% natural gas to 100% hydrogen. The required fuel usages are estimated for the intended application in a grid scenario that features large amounts of renewable penetration, 10 hours, and as a baseload, 100 hours. The study presents preliminary estimates of the capital cost of storage and operating cost of storage. In addition, the cost of firing natural gas and capturing the carbon dioxide (CO2) in a carbon capture and sequestration (CCS) system is assessed. Based on the study, it is shown that CFC can competitively meet performance and cost needs for grid-based energy storage.

08 HYDROGEN↗

Microscale gas breakdown device and process

A microscale gas breakdown device includes a first surface and a second surface. The first surface and the second surface define a gap distance. The device includes a perturbation on the first surface or the second surface. The perturbation is defined by a height value and a radius value. The device includes a current source or a voltage source configured to apply a current or a voltage across the first surface and the second surface. In response to the current or the voltage being applied, a resulting discharge travels along a first discharge path in response to being exposed to a high pressure and a second discharge path in response to being exposed to a low pressure.

Fu, Yangyang↗

Modulating physicochemical interfaces enables li-rich oxides based ceramic solid-state li batteries under ambient conditions

Li-rich layered oxides exhibit promising potential applications in high-energy-density solid-state lithium metal batteries. Nevertheless, the strong oxidative oxygen species generate at high voltage, which poses great challenges to positive electrode-side interface stability. Herein, a robust in-situ polymerization gel polymer electrolyte with bifunctional additives is designed for interface modification. These additives, include lithium difluoro(oxalate) borate and LiPO 2 F 2 , regulate the Li + chemical environment in gel polymer electrolyte to enhance crosslink density without residual oligomer, which reduce gas generation and suppress contact loss, thus avoiding interfacial impedance divergence. Concurrently, the designed gel polymer electrolyte enables a wide electrochemical stability window (up to 4.7 V) and a high Li + transference number (0.82). Additionally, the additives induced F- and B-rich inorganic cathode-electrolyte interphase inhibits side reactions and oxygen/transition metal loss effectively, stabilizing the chemical interface. The as-constructed Li-rich layered oxides-based ceramic solid-state lithium metal batteries with gel polymer electrolyte interface modification exert a high discharge capacity of 276.5 mAh g -1 at 30 °C without external pressure, delivering a retention of 81.7% after 100 cycles at 25 mA g -1 during 2.0-4.7 V. This work provides a guideline for developing high-voltage solid-state lithium metal batteries via interfacial design.

Hu, Xinchao [Xiamen University (China)]↗

First feedback-controlled divertor detachment in W7-X: Experience from TDU operation and prospects for operation with actively cooled divertor

In the last experimental campaign (OP1.2b) of the stellarator Wendelstein 7-X (W7-X), boronisation as a mean for first wall conditioning was applied for the first time which led to strongly reduced impurity fluxes from plasma-facing components. Thermal detachment at the uncooled target plates of the test divertor unit (TDU) was reached at higher plasma densities and was accompanied by high recycling of neutrals at the target plate. A feedback control system was established in W7-X to actively control the gas injection (actuator) for plasma fuelling and impurity seeding [3] through the divertors. It allowed very successful stabilisation of the detached plasma condition state as well as mitigation of thermal overloads to some baffle tiles. Different routinely available diagnostic signals were used as input parameters (sensors). We describe the setup of the feedback control system, its performance and provide some example results with the main focus on the development of the control scheme which led to the detachment stabilisation over the entire longest (30 s) high-power discharge at W7-X so far. In view of the achieved very successful detachment stabilisation and the necessity to include simultaneous optimisation of the core performance in the future, the feedback control system is being upgraded for the upcoming campaign (OP2.1) in which the water cooled and hereby inherently steady-state capable divertor has been currently installed. The prospects and some experiment ideas for active detachment control are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

How exudates production along a phosphorus gradient influences mineral dissolution across contrasting soil development stages

Harnessing rhizosphere processes offers a valuable opportunity to optimize nutrient use efficiency in agroecosystems. In nutrient-limited soils, plants discharge part of photosynthate surplus via root exudation, including carboxylates, which may enhance mineral dissolution and nutrient mobilization. We aimed to assess how plant responses to nutrient limitation translated into changes in exudate profiles, and how these exudates, in turn, drive bioweathering processes across soils of contrasting mineralogy and weathering degree. We conducted a hydroponic experiment with Lupinus albus grown under five phosphorus (P) concentrations (5, 10, 20, 30, and 50 µM) over seven weeks. We measured plant biomass and root traits, performed a metabolomics analysis and quantified seven carboxylates in root exudates using gas chromatography-mass spectrometry. To assess bioweathering processes across contrasted soil domains, we conducted batch dissolution tests with exudates using three soil horizons—35 each with distinct physicochemical properties: enriched in organic matter, iron oxides, or primary silicates. At the intermediate level of P supply, shoot biomass was comparable to that under high P, but plants produced more root biomass and a higher total carboxylate exudation rate. Despite low carboxylate concentrations (<100 ppb), exudates promoted the dissolution of Ca, Mg, Si, Fe, P and K in all horizons. Yet, the degree of element released varied among horizons. These findings highlight the importance of root exudates in enhancing mineral dissolution, with effects dependent on soil physicochemical properties. The results suggest that managing agroecosystems under moderate nutrient limitation could be a sustainable strategy to increase root-to-shoot ratios, enhance bioweathering processes and nutrient release in soil solution.