Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: Dosimetric impact of fluorescence x rays

Purpose: The detailed study of a new permanent iodine-125 brachytherapy source, SmartSeed, is presented in this article. It is the first iodine seed made with biocompatible polymer and is manufactured by the IBt-Bebig group. Methods: Three dosimetric studies have been performed: The first one used thermoluminescent detectors in a solid water phantom with NIST (National Institute of Standards and Technology, USA) calibrated seeds, and two separate studies were of Monte Carlo photon transport calculations (MCNP5 code). The TG-43U1 protocol was applied to derive dosimetric parameters for clinical applications. Results: The radial dose function g(r) was determined at different distances ranging from 0.5 to 10 cm; and the anisotropy function F(r,{theta}) at angles ranging from 0 deg. to 350 deg. in 10 deg. increments. Monte Carlo calculations were performed in liquid water to obtain values for {Lambda}, g(r), F(r,{theta}), and {phi}{sub an}(r) as recommended by the TG-43U1 protocol for use in treatment planning system software. SmartSeed's biocompatible polymer capsule permits fluorescence x rays (3, 5, and 12 keV), generated by lead glass marker, to be present in the emission spectrum, influencing the dose rate constant. The impact on near field dosimetry in water from these x rays was also investigated and reported. The capsule also attenuates iodine-125 energies much less than typical titanium encased sources, resulting in a highly isotropic source. Conclusions: SmartSeed has a dose rate constant of 0.895{+-}7.3% cGy h{sup -1} U{sup -1}, a radial dose function nearly identical to the IBt-Bebig model I25.S06 seed, and a highly isotropic dose distribution. Fluorescence x rays account for the relatively low value of {Lambda}, yet their variable contribution to dosimetry arising from seed dimensional uncertainties is estimated to be <0.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Barium Chemosensors with Dry-Phase Fluorescence for Neutrinoless Double Beta Decay

The nature of the neutrino is one of the major open questions in experimental nuclear and particle physics. The most sensitive known method to establish the Majorana nature of the neutrino is detection of the ultra-rare process of neutrinoless double beta decay. However, identification of one or a handful of decay events within a large mass of candidate isotope, without obfuscation by backgrounds is a formidable experimental challenge. One hypothetical method for achieving ultra- low-background neutrinoless double beta decay sensitivity is the detection of single 136 Ba ions produced in the decay of 136 Xe (“barium tagging”). To implement such a method, a single-ion-sensitive barium detector must be developed and demonstrated in bulk liquid or dry gaseous xenon. This paper reports on the development of two families of dry-phase barium chemosensor molecules for use in high pressure xenon gas detectors, synthesized specifically for this purpose. One particularly promising candidate, an anthracene substituted aza-18-crown-6 ether, is shown to respond in the dry phase with almost no intrinsic background from the unchelated state, and to be amenable to barium sensing through fluorescence microscopy. This interdisciplinary advance, paired with earlier work demonstrating sensitivity to single barium ions in solution, opens a new path toward single ion detection in high pressure xenon gas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of image quality and image-guidance performance of a preclinical microirradiator

Purpose: To assess image quality and image-guidance capabilities of a cone-beam CT based small-animal image-guided irradiation unit (micro-IGRT). Methods: A micro-IGRT system has been developed in collaboration with the authors' laboratory as a means to study the radiobiological effects of conformal radiation dose distributions in small animals. The system, the X-Rad 225Cx, consists of a 225 kVp x-ray tube and a flat-panel amorphous silicon detector mounted on a rotational C-arm gantry and is capable of both fluoroscopic x-ray and cone-beam CT imaging, as well as image-guided placement of the radiation beams. Image quality (voxel noise, modulation transfer, CT number accuracy, and geometric accuracy characteristics) was assessed using water cylinder and micro-CT test phantoms. Image guidance was tested by analyzing the dose delivered to radiochromic films fixed to BB's through the end-to-end process of imaging, targeting the center of the BB, and irradiation of the film/BB in order to compare the offset between the center of the field and the center of the BB. Image quality and geometric studies were repeated over a 5-7 month period to assess stability. Results: CT numbers reported were found to be linear (R{sup 2}{>=}0.998) and the noise for images of homogeneous water phantom was 30 HU at imaging doses of approximately 1 cGy (to water). The presampled MTF at 50% and 10% reached 0.64 and 1.35 mm{sup -1}, respectively. Targeting accuracy by means of film irradiations was shown to have a mean displacement error of [{Delta}x,{Delta}y,{Delta}z]=[-0.12,-0.05,-0.02] mm, with standard deviations of [0.02, 0.20, 0.17] mm. The system has proven to be stable over time, with both the image quality and image-guidance performance being reproducible for the duration of the studies. Conclusions: The micro-IGRT unit provides soft-tissue imaging of small-animal anatomy at acceptable imaging doses ({<=}1 cGy). The geometric accuracy and targeting systems permit dose placement with submillimeter accuracy and precision. The system has proven itself to be stable over 2 yr of routine laboratory use (>1800 irradiations) and provides a platform for the exploration of targeted radiation effects in small-animal models.

60 APPLIED LIFE SCIENCES↗

Making Optical-Fiber Chemical Detectors More Sensitive

Calculations based on exact theory of optical fiber shown how to increase optical efficiency and sensitivity of active-cladding step-index-profile optical-fiber fluorosensor using evanescent wave coupling. Optical-fiber fluorosensor contains molecules fluorescing when illuminated by suitable light in presence of analyte. Fluorescence coupled into and launched along core by evanescent-wave interaction. Efficiency increases with difference in refractive indices.

Rogowski, Robert S.↗

Neutral-current neutrino cross section and expected supernova signals for 40 Ar from a three-fold increase in the magnetic dipole strength

In view of the great interest in liquid argon neutrino detectors, the 40 Ar(γ,γ') 40 Ar reaction was revisited to guide a calculation of the neutral current neutrino cross section at supernova energies. Using the nuclear resonance fluorescence technique with a monoenergetic, 99% linearly polarized photon beam, in this work we report a three-fold increase in magnetic dipole strength at around 10 MeV in 40 Ar. Based on shell-model calculations, and using the experimentally identified transitions, the neutral current neutrino cross sections for low-energy reactions on 40 Ar are calculated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The development and use of metal-based probes for X-ray fluorescence microscopy

Abstract X-ray fluorescence microscopy (XFM) has become a widely used technique for imaging the concentration and distribution of metal ions in cells and tissues. Recent advances in synchrotron sources, optics, and detectors have improved the spatial resolution of the technique to <10 nm with attogram detection sensitivity. However, to make XFM most beneficial for bioimaging—especially at the nanoscale—the metal ion distribution must be visualized within the subcellular context of the cell. Over the years, a number of approaches have been taken to develop X-ray-sensitive tags that permit the visualization of specific organelles or proteins using XFM. In this review, we examine the types of X-ray fluorophore used, including nanomaterials and metal ions, and the approaches used to incorporate the metal into their target binding site via antibodies, genetically encoded metal-binding peptides, affinity labeling, or cell-specific peptides. We evaluate their advantages and disadvantages, review the scientific findings, and discuss the needs for future development.

36 MATERIALS SCIENCE↗

Study of Triple Ar Gas Puff Z-Pinches on 0.9-MA, 200-ns COBRA

Ar gas puff z-pinch experiments were conducted on the 0.9 MA, 200 ns COBRA generator at Cornell University. In the experiments, a triple-nozzle gas valve was used to produce the zpinch load with concentric outer and inner gas puffs and a central gas jet. We used Planer Laser Induced Fluorescence (PLIF) to measure the initial gas profile of the load, two 4-frame 4-ns gated XUV cameras to image the imploding plasma, and filtered Photo- Conducting Diamond Detectors (PCDs) to measure the x-ray output. We have observed shock heating and/or photoionization of the dense center jet by the imploding plasma. With an outer to inner plenum pressure ratio of 1:3, de-acceleration of the imploding plasma occurred when the outer plasma shell imploded on the inner shell resulting in a stable implosion. By varying the plenum pressure for the center jet, the x-ray emission was optimized. In conclusion, an Ar K-shell x-ray (3-4 keV) yield of 77±17 J was produced at a current level of 0.87±0.2 MA and an implosion time of 200-ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Qualitative and quantitative flow visualization technique using ozone

The paper describes a new flow-visualization technique based on the absorption of ultraviolet light by ozone. Ozone is an excellent tracer, because as a gas it has the same effective physical properties as air. Ozone strongly absorbs the principal line (253.7 nm) of a mercury lamp, so that when an ozone-traced flow passes between a mercury lamp and a fluorescent screen, a sharp, shadow-like image of the ozone tracer is cast on the screen. Quantitative photometry can be carried out by replacing the screen with ultraviolet detectors that yield the path-integrated column density of ozone in the flow. High-speed quantitative point monitoring (10 Hz at 10 ppb O3) is possible with capillary probes and chemiluminescent analysis.

Dickerson, R. R.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

First results from the TUS orbital detector in the extensive air shower mode

TUS (Tracking Ultraviolet Set-up), the first orbital detector of extreme energy cosmic rays (EECRs), those with energies above 50 EeV, was launched into orbit on April 28, 2016, as a part of the Lomonosov satellite scientific payload. The main aim of the mission is to test a technique of registering fluorescent and Cherenkov radiation of extensive air showers generated by EECRs in the atmosphere with a space telescope. We present preliminary results of its operation in a mode dedicated to registering extensive air showers in the period from August 16, 2016, to November 4, 2016. No EECRs have been conclusively identified in the data yet, but the diversity of ultraviolet emission in the atmosphere was found to be unexpectedly rich. We discuss typical examples of data obtained with TUS and their possible origin. The data is important for obtaining more accurate estimates of the nocturnal ultraviolet glow of the atmosphere, necessary for successful development of more advanced orbital EECR detectors including those of the KLYPVE (K-EUSO) and JEM-EUSO missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Innovations in X-ray-induced electron emission spectroscopy (XIEES)

Currently, a pressing need has arisen for controlling the local atomic and electron structure of materials irrespective of their aggregate state. Efficient approaches to the studies of short-range order are based on phenomena accompanied by interference of secondary electrons excited by primary X-ray radiation. The set of such approaches are commonly referred to as the X-ray absorption fine structure (XAFS) methods. In reality, the XAFS methods are based on the use of synchrotron radiation and applied to structural studies in two modes of measurements, transmission analysis and recording of secondary effects. Only two such effects-specifically, the X-ray fluorescence an d X-ray-induced electron emission effect-are commonly discussed. Access to synchrotron accelerators is problematic for most researchers, so a demand is created for designing laboratory systems that make direct access possible. Since the power of laboratory systems is much lower than that of synchrotrons, it is essential to use much more efficient detectors of secondary electrons. In addition, it is of interest to analyze energy characteristics with a high spatial resolution. Channel multipliers and multichannel boards are incapable of providing such a possibility. For this reason, an improved electron detector has been developed to analyze the photoemission effect in an accelerating field.

36 MATERIALS SCIENCE↗

WE-DE-201-10: Pitfalls When Using Ruby as An Inorganic Scintillator Detector for Ir-192 Brachytherapy Dosimetry

Purpose: To study the promising potential of inorganic scintillator detectors (ISDs) and investigate various unwanted luminescence properties which may compromise their accuracy. Methods: The ISDs were comprised of a ruby crystal coupled to a polymethyl methacrylate (PMMA) fiber-optic cable and a charged coupled device camera. A new type of ISD was manufactured and included a long-pass filter that was sandwiched between the crystal and the fiber-optic cable. The purpose of the filter was to suppress the Cerenkov and fluorescence background light induced in the PMMA (the stem signal) from striking the ruby crystal, generating unwanted ruby excitation. A variety of experiments were performed to characterize the ruby based ISDs. The relative contribution of the induced ruby signal and the stem signal were quantified while exposing the detector and a bare fiber-optic cable to a high dose rate (HDR) brachytherapy (BT) source, respectively. The unwanted ruby excitation was quantified while irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and a comparison to other commonly used organic scintillator detectors (BCF-12, BCF-60). Results: When the BT source dwelled 0.5 cm away from the fiber-optic cable, the unwanted ruby excitation amounted to >5% of the total signal if the source-distance from the scintillator was >7 cm. However, the unwanted excitation was suppressed to <1% if the ISD incorporated an optic filter. The stem signal was suppressed with a 20 nm band-pass filter and was <3% as long as the source-distance was <7 cm. The ruby based ISDs generated signal up to 20(40) times that of BCF-12(BCF-60). Conclusion: The study presents solutions to unwanted luminescence properties of ruby based ISDs for HDR BT. An optic filter should be sandwiched between the scintillator volume and the fiber-optic cable to prevent the stem signal to excite the ruby crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Nanocrystal Spectroscopy of Shortwave Infrared Emitters

Short-wave infrared (SWIR) emitters are at the center of ground-breaking applications in biomedical imaging, next-generation optoelectronic devices, and optical communications. Colloidal nanocrystals based on indium arsenide are some of the most promising SWIR emitters to date. However, the lack of single-particle spectroscopic methods accessible in the SWIR has prevented advances in both nanocrystal synthesis and fundamental characterization of emitters. In this paper, we demonstrate an implementation of a solution photon correlation Fourier spectroscopy (s-PCFS) experiment utilizing the SWIR sensitivity and time resolution of superconducting nanowire single-photon detectors to extract single-particle emission linewidths from colloidal indium arsenide/cadmium selenide (InAs/CdSe) core/shell nanocrystals emissive from 1.2 to 1.6 μm. We show that the average single InAs/CdSe nanocrystal fluorescence linewidth is, remarkably, as narrow as 52 meV, similar to what has been observed in some of the most narrowband nanostructured emitters in the visible region. Additionally, the single nanocrystal fluorescence linewidth increases with increasing shell thickness, suggesting exciton–phonon coupling as the dominant emission line-broadening mechanism in this system. The development of the SWIR s-PCFS technique has enabled measurements of spectral linewidths of colloidal SWIR-emissive NCs in solution and provides a platform to study the single NC spectral characteristics of SWIR emitters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

The Focal Surface of the JEM-EUSO Instrument

The Extreme Universe Space Observatory on JEM/EF (JEM-EUSO) is a space mission to study extremely high-energy cosmic rays. The JEM-EUSO instrument is a wide-angle refractive telescope in the near-ultraviolet wavelength region which will be mounted to the International Space Station. Its goal is to measure time-resolved fluorescence images of extensive air showers in the atmosphere. In this paper we describe in detail the main features and technological aspects of the focal surface of the instrument. The JEM-EUSO focal surface is a spherically curved surface, with an area of about 4.5m{sup 2}. The focal surface detector is made of more than 5,000 multi-anode photomultipliers (MAPMTs). Current baseline is Hamamatsu R11265-03-M64. The approach to the focal surface detector is highly modular. Photo-Detector-Modules (PDM) are the basic units that drive the mechanical structure and data acquisition. Each PDM consists of 9 Elementary Cells (ECs). The EC, which is the basic unit of the MAPMT support structure and of the front-end electronics, contains 4 units of MAPMTs. In total, about 1,200 ECs or about 150 PDMs are arranged on the whole of the focal surface of JEM-EUSO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-17A-08: Monte Carlo Based Design of Efficient Scintillating Fiber Dosimeters

Purpose: To accurately predict Cherenkov radiation generation in scintillating fiber dosimeters. Quantifying Cherenkov radiation provides a method for optimizing fiber dimensions, orientation, optical filters, and photodiode spectral sensitivity to achieve efficient real time imaging dosimeter designs. Methods: We develop in-house Monte Carlo simulation software to model polymer scintillation fibers' fluorescence and Cherenkov emission in megavoltage clinical beams. The model computes emissions using generation probabilities, wavelength sampling, fiber photon capture, and fiber transport efficiency and incorporates the fiber's index of refraction, optical attenuation in the Cherenkov and visible spectrum and fiber dimensions. Detector component selection based on parameters such as silicon photomultiplier efficiency and optical coupling filters separates Cherenkov radiation from the dose-proportional scintillating emissions. The computation uses spectral and geometrical separation of Cherenkov radiation, however other filtering techniques can expand the model. Results: We compute Cherenkov generation per electron and fiber capture and transmission of those photons toward the detector with incident electron beam angle dependence. The model accounts for beam obliquity and nonperpendicular electron fiber impingement, which increases Cherenkov emission and trapping. The rotational angle around square fibers shows trapping efficiency variation from the normally incident minimum to a maximum at 45 degrees rotation. For rotation in the plane formed by the fiber axis and its surface normal, trapping efficiency increases with angle from the normal. The Cherenkov spectrum follows the theoretical curve from 300nm to 800nm, the wavelength range of interest defined by silicon photomultiplier and photodiode spectral efficiency. Conclusion: We are able to compute Cherenkov generation in realistic real time scintillating fiber dosimeter geometries. Design parameters incorporate fiber dimensions, orientations, several types of detector spectral response, optical coupling filters and light transport. We can vary these parameters to design and optimize high efficiency real time dosimeters capable of enhancing external beam patient safety and treatment accuracy. This research was supported in part by a GAANN Fellowship from the Department of Education.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a laser fluorosensor for airborne surveying of the aquatic environment

A field based laser fluorosensor, employing a pulsed nitrogen laser and telescope photomultiplier detector system, has been successfully tested at night from a cliff top site overlooking Lake Ontario providing target ranges greater than 274 meters. Remotely sensed spectra and amplitude changes in the fluorescence emission of natural waters have shown potential as a water quality indicator. In this connection, a convenient internal reference standard with which to gauge the amplitude of the fluorescence signal is realized in the form of the concurrent water Raman emission. Remote measurements of oil fluorescence emission spectra suggest that airborne laser fluorosensors are capable of detecting and characterizing the oil in a given slick and that environmental aging of these slicks does not significantly alter their fluorescence emission signature.

Bristow, M. P. F.↗