Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Florida”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Data from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes six synchronized high-speed video cameras, current sensors installed on the nine downcouductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31, 2011. The measured peak currents and locations are compared to those reported by the CGLSS 11 and the NLDN. Results of comparison are presented and analyzed in this paper.

Mata, Carlos T.↗

Summary of 2011 Direct and Nearby Lightning Strikes to Launch Complex 39B, Kennedy Space Center, Florida

A Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida in 2009. This LPS was instrumented with comprehensive meteorological and lightning data acquisition systems that were deployed from late 2010 until mid 2011. The first direct strikes to the LPS were recorded in March of 2011, when a limited number of sensors had been activated. The lightning instrumentation system detected a total of 70 nearby strokes and 19 direct strokes to the LPS, 2 of the 19 direct strokes to the LPS had two simultaneous ground attachment points (in both instances one channel terminated on the LPS and the other on the nearby ground). Additionally, there are more unaccounted nearby strokes seen on video records for which limited data was acquired either due to the distance of the stroke or the settings of the data acquisition system. Instrumentation deployment chronological milestones, a summary of lightning strikes (direct and nearby), high speed video frames, downconductor currents, and dH/dt and dE/dt typical waveforms for direct and nearby strokes are presented.

Mata, C.T.↗

Florida Tech CubeSat Experiment Feasibility Study

CubeSats are a relatively new type of satellite. Smaller than long-term (5+ year life expectancy) satellites, these pico-satellites are comparatively cheap, small (10x10x10 cm), and are very versatile. Universities world-wide are using CubeSats to conduct a variety of experiments in space without the need for a large experimental platform. Today CubeSats are considered to be one of the most effective ways to send a small payload into space and has attracted the attention of many educational and non-profit organizations. As this pico-satellite model continues to gain penetration into the satellite build and launch industry, it is expected that more governmental, educational, and commercial interests will emerge. As an example, more of the space-related items of high interest to the National Science Foundation may be tackled with a CubeSat platform resulting in lower life cycle costs than traditional satellite options. NASA LSP, in cooperation with the Florida Institute of Technology, has initiated a feasibility study to investigate the technical aspects of measuring and transferring vibration, acceleration, temperature, and video data from a CubeSat to NASA Hanger AE on Cape Canaveral Air Force Station (CCAFS) a.k.a. Kennedy Space Center (KSC). This report provides a technical feasibility analysis to determine whether-or-not a specific set of NASA/LSP requirements can be accomplished. Our approach has been to provide a "notional" component layout to determine the feasibility of the NASA/LSP stakeholder requirements. The notional layout is used to consider component level technical issues such as size, weight, & power (SWaP), bandwidth, and other critical technical parameters. Even though the notional components may satisfy the stated requirements and thereby demonstrate feasibility, the notional layout is NOT considered a design since no component optimization and design trade-off analysis has taken place. This activity should be accomplished in an appropriate design phase that is outside of the scope of this effort.

Arrasmith, William W.↗

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Dalta from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes seven synchronized high-speed video cameras, current sensors installed on the nine downconductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31 2011. The measured peak currents and locations are compared to those reported by the Cloud-to-Ground Lightning Surveillance System (CGLSS II) and the National Lightning Detection Network (NLDN). Results of comparison are presented and analyzed in this paper.

Mata, C. T.↗

Validation of MODIS FLH and In Situ Chlorophyll a from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a (chla) is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chl-a inaccurate. Measurement of suninduced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum may, provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms or compared their accuracy against bluegreen ratio algorithms . In an unprecedented analysis using a long term (2003-2011) in situ monitoring data set from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer against a suite of water quality parameters taken in a variety of conditions throughout this large optically complex estuarine system. . Overall, the results show a 106% increase in the validity of chla concentration estimation using FLH over the standard chla estimate from the blue-green OC3M algorithm. Additionally, a systematic analysis of sampling sites throughout the bay is undertaken to understand how the FLH product responds to varying conditions in the estuary and correlations are conducted to see how the relationships between satellite FLH and in situ chlorophyll-a change with depth, distance from shore, from structures like bridges, and nutrient concentrations and turbidity. Such analysis illustrates that the correlations between FLH and in situ chla measurements increases with increasing distance between monitoring sites and structures like bridges and shore. Due probably to confounding factors, expected improvement in the FLH- chla relationship was not clearly noted when increasing depth and distance from shore alone (not including bridges). Correlations between turbidity and nutrient concentrations are discussed further and principle component analyses are employed to address the relationships between the multivariate data sets. A thorough understanding of how satellite FLH algorithms relate to in situ water quality parameters will enhance our understanding of how MODIS s global FLH algorithm can be used empirically to monitor coastal waters worldwide.

Fischer, Andrew↗

Calculating the Lightning Protection System Downconductors' Grounding Resistance at Launch Complex 39B, Kennedy Space Center, Florida

A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC). Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulation installed atop three towers in a triangular configuration. Nine downconductors (each about 250 meters long) are connected to the catenary wire system. Each downconductor is connected to a 7.62-meter-radius circular counterpoise conductor with six equally spaced. 6-meter-1ong vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping. enclosures, raceways. and. cable trays. within 7.62 meters of. counterpoise, to be bonded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways and cable trays that run in multiple directions around LC39B.

Mata, Carlos↗

The Validity Chlorophyll-a Estimation by Sun Induced Fluorescence in Estuarine Waters: An Analysis of Long-term (2003-2011) Water Quality Data from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chlorophyll-a inaccurate. Measurement of sun-induced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum, may provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite baseline algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms using a comprehensive long term in situ data set. In an unprecedented analysis of a long term (2003-2011) in situ monitoring data from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer (MODIS) against chlorophyll ]a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions within the estuary including water depth, distance from shore and structures and eight water quality parameters. From the 39 station for which data was derived, 22 stations showed significant correlations when the FLH product was matched with in situ chlorophyll-alpha data. The correlations (r2) for individual stations within Tampa Bay ranged between 0.67 (n=28, pless than 0.01) and-0.457 (n=12, p=.016), indicating that for some areas within the Bay, FLH can be a good predictor of chlorophyll-alpha concentration and hence a useful tool for the analysis of water quality. Overall, the results show a 106% increase in the validity of chlorophyll -a concentration estimates using FLH over the standard the blue-green OC3M algorithm. This analysis also illustrates that the correlations between FLH and in situ chlorophyll -a measurements increases with increasing water depth and distance of the monitoring sites from both the shore and structures. However, due to confounding factors related to the complexity of the estuarine system, a linear improvement in the FLH to chlorophyll ]a relationship was not clearly noted with increasing depth and distance from shore alone. Correlations of FLH with turbidity, nutrients (total nitrogen and total phosphorous) biological oxygen demand, salinity, sea surface temperature correlated positively with FLH concentrations, while dissolved oxygen and pH showed negative correlations. Principle component analyses are employed to further describe the relationships between the multivariate water quality parameters and the FLH product. The majority of sites with higher and very significant correlations (pless than 0.01) also showed high correlation values for nutrients, turbidity and biological oxygen demand. These sites were on average in greater than seven meters of water and over five kilometers from shore. A thorough understanding of the relationship between the MODIS FLH product and in situ water quality parameters will enhance our understanding of the accuracy MODIS fs global FLH algorithm and assist in optimizing its calibration for use in monitoring the quality of estuarine and coastal waters worldwide.

Moreno-Madrinan, Max Jacobo↗

NASA's Impact in Florida: A Tech Transfer Perspective

The Innovative Partnerships Program (IPP) Office at NASA's Kennedy Space Center is dedicated to forming partnerships that can positively contribute to -- and benefit from -- NASA's research and development (R&D) and technology innovations. This document discusses the IPP-driven impacts of NASA in Florida.

Dunn, Carol↗

Spatial Correlation and Coherence of Boundary Layer Winds Near Cape Canaveral Florida

The spatial correlation and coherence of winds over separation distances from 8.5 to 31 km based on central Florida data from November 1999 through August 2001 are presented. The winds at altitudes from 500 to 3000 m were measured using a network of five radar wind profilers. The goal was to determine the extent to which the profilers may be considered independent data sources. Quality controlled profiles were produced every 15 minutes for up to sixty gates, each representing 101 m in altitude over the range from 130 m to 6089 m. Five levels, each containing three consecutive gates, were selected for analysis. These levels covered the range from 433 to 3059 m. The results show that the profilers are independent for features having time scales of less than one hour in the winter or two hours in the summer. This does not depend significantly on height. Because the size of the network coincides with the "spectral gap" in the boundary layer, the result also does not depend on the spacing of the profilers within the network.

Merceret, Francis J.↗

Observed Enhancement of Reflectivity and Electric Field in Long-Lived Florida Anvils

A study of two long-lived Florida anvils showed that reflectivity >20 dBZ increased in area, thickness and sometimes magnitude at mid-level well downstream of the convective cores. In these same regions electric fields maintained strengths >10 kV m1 for many tens of minutes and became quite uniform over tens of kilometers. Millimetric aggregates persisted at 9 to 10 km for extended times and distances. Aggregation of ice particles enhanced by strong electric fields might have contributed to reflectivity growth in the early anvil, but is unlikely to explain observations further out in the anvil. The enhanced reflectivity and existence of small, medium and large ice particles far out into the anvil suggest that an updraft was acting, perhaps in weak convective cells formed by instability generated from the evaporation and melting of falling ice particles. We conclude that charge separation must have occurred in these anvils, perhaps at the melting level but also at higher altitudes, in order to maintain fields >10 kV m 1 at 9 to 10 km for extended periods of time over large distances. We speculate that charge separation occurred as a result of ice-ice particle collisions (without supercooled water being present) via either a non-inductive or perhaps even an inductive mechanism, given the observed broad ice particle spectra, the strong pre-existing electric fields and the many tens of minutes available for particle interactions. The observations, particularly in the early anvil, show that the charge structure in these anvils was quite complex.

Dye, James E.↗

Kennedy Space Center Florida Scrub-Jay Compensation Plan

Many organizations have interest in using NASA property on KSC. The purpose of this document is to consolidate the goals of ecosystem management associated with Florida Scrub-Jays and compliance with the Endangered Species Act (ESA) in order to streamline and reduce the costs of facility planning, impact assessment, and impact minimization. This will simplify the process and reduce regulatory uncertainty.However, the resulting process must be consistent with the Merritt Island National Wildlife Refuge (MINWR) Comprehensive Conservation Plan (CCP). In addition, this document considers anticipated construction impacts on KSC during the next 10 years and summarizes priorities in a spatially explicit manner. The document describes anticipated compensation requirements to facilitate restoration of degraded habitat in areas most important to the KSC Scrub-Jay population through resources provided to MINWR. The plan assumes that all construction on KSC is compensated on KSC.

Compensation Plan↗

Ecological Impacts of the Space Shuttle Program at John F. Kennedy Space Center, Florida

The Space Shuttle Program was one of NASAs first major undertakings to fall under the environmental impact analysis and documentation requirements of the National Environmental Policy Act of 1969 (NEPA). Space Shuttle Program activities at John F. Kennedy Space Center (KSC) and the associated Merritt Island National Wildlife Refuge (MINWR) contributed directly and indirectly to both negative and positive ecological trends in the region through the long-term, stable expenditure of resources over the 40 year program life cycle. These expenditures provided support to regional growth and development in conjunction with other sources that altered land use patterns, eliminated and modified habitats, and contributed to cultural eutrophication of the Indian River Lagoon. At KSC, most Space Shuttle Program related actions were conducted in previously developed facilities and industrial areas with the exception of the construction of the shuttle landing facility (SLF) and the space station processing facility (SSPF). Launch and operations impacts were minimal as a result of the low annual launch rate. The majority of concerns identified during the NEPA process such as potential weather modification, acid rain off site, and local climate change did not occur. Launch impacts from deposition of HCl and particulates were assimilated as a result of the high buffering capacity of the system and low launch and loading rates. Metals deposition from exhaust deposition did not display acute impacts. Sub-lethal effects are being investigated as part of the Resource Conservation and Recovery Act (RCRA) regulatory process. Major positive Space Shuttle Program effects were derived from the adequate resources available at the Center to implement the numerous environmental laws and regulations designed to enhance the quality of the environment and minimize impacts from human activities. This included reduced discharges of domestic and industrial wastewater, creation of stormwater management systems, remediation of past contamination sites, implementation of hazardous waste management systems, and creation of a culture of sustainability. Working with partners such as the USFWS and the St Johns River Water Management District (SJRWMD), wetlands and scrub restoration and management initiatives were implemented to enhance fish and wildlife populations at the Center. KSC remains the single largest preserve on the east coast of Florida in part due to NASAs commitment to stewardship. Ongoing Ecological Program projects are directed at development of information and knowledge to address future KSC management questions including the transition to a joint government and commercial launch facility, enhanced habitat management requirements for wetlands and scrub, potential impacts of emerging contaminants, and adaptation to climate change including projected sea level rise over the next 50-75 years.

Space Shuttle Program↗

Evaluation of the Performance Characteristics of the CGLSS and NLDN Systems Based on Two Years of Ground-Truth Data from Launch Complex 39B, Kennedy Space Center, Florida

From May 2011 through July 2013, the lightning instrumentation at Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida, has obtained high-speed video records and field change waveforms (dE/dt and three-axis dH/dt) for 54 negative polarity return strokes whose strike termination locations and times are known with accuracy of the order of 10 m or less and 1 μs, respectively. A total of 18 strokes terminated directly to the LC39B lighting protection system (LPS), which contains three 181 m towers in a triangular configuration, an overhead catenary wire system on insulating masts, and nine down conductors. An additional 9 strokes terminated on the 106 m lightning protection mast of Launch Complex 39A (LC39A), which is located about 2.7 km southeast of LC39B. The remaining 27 return strokes struck either on the ground or attached to low-elevation grounded objects within about 500 m of the LC39B LPS. Leader/return stroke sequences were imaged at 3200 frames/sec by a network of six Phantom V310 high-speed video cameras. Each of the three towers on LC39B had two high-speed cameras installed at the 147 m level with overlapping fields of view of the center of the pad. The locations of the strike points of 54 return strokes have been compared to time-correlated reports of the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the National Lightning Detection Network (NLDN), and the results of this comparison will be presented and discussed.

Waveforms↗

Launch Complex 39 Observation Gantry Area (SWMU# 107) Annual Long-Term Monitoring Report (Year 1) Kennedy Space Center, Florida

This document has been prepared by Geosyntec Consultants, Inc. (Geosyntec) to present and discuss the findings of the 2014 and 2015 Long-Term Monitoring (LTM) activities that were completed at the Launch Complex 39 (LC39) Observation Gantry Area (OGA) located at the John F. Kennedy Space Center (KSC), Florida (Site). The remainder of this report includes: (i) a description of the Site location; (ii) summary of Site background and previous investigations; (iii) description of field activities completed as part of the annual LTM program at the Site; (iv) groundwater flow evaluation; (v) presentation and discussion of field and analytical results; and (vi) conclusions and recommendations. Applicable KSC Remediation Team (KSCRT) Meeting minutes are included in Attachment A. This Annual LTM Letter Report was prepared by Geosyntec Consultants (Geosyntec) for NASA under contract number NNK12CA13B, Delivery Order NNK13CA39T project number PCN ENV2188.

Long Term Monitoring↗

Wilson Corners SWMU 001 2014 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2014 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC), Florida. The goals of the 2014 annual LTM event were to evaluate the groundwater flow direction and gradient and to monitor the vertical and downgradient horizontal extent of the volatile organic compounds (VOCs) in groundwater at the site. The LTM activities consisted of an annual groundwater sampling event in December 2014, which included the collection of water levels from the LTM wells. During the annual groundwater sampling event, depth to groundwater was measured and VOC samples were collected using passive diffusion bags (PDBs) from 30 monitoring wells. In addition to the LTM sampling, additional assessment sampling was performed at the site using low-flow techniques based on previous LTM results and assessment activities. Assessment of monitoring well MW0052DD was performed by collecting VOC samples using low-flow techniques before and after purging 100 gallons from the well. Monitoring well MW0064 was sampled to supplement shallow VOC data north of Hot Spot 2 and east of Hot Spot 4. Monitoring well MW0089 was sampled due to its proximity to MW0090. MW0090 is screened in a deeper interval and had an unexpected detection of trichloroethene (TCE) during the 2013 LTM, which was corroborated during the March 2014 verification sampling. Monitoring well MW0130 was sampled to provide additional VOC data beneath the semi-confining clay layer in the Hot Spot 2 area.

Monitoring↗

Converter Compressor Building, SWMU 089, Hot Spot Areas 1, 2, and 5 Operations, Maintenance, and Monitoring Report, Kennedy Space Center, Florida

This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The next performance monitoring event is scheduled for July 2015.

Converter Compressor Building↗

Plasma Glucose Levels for Red Drum Sciaenops Ocellatus in a Florida Estuarine Fisheries Reserve

Despite the significant value of the southeastern United States' red drum (Sciaenops ocellatus) fishery, there is a lack of clinical blood chemistry data. This was the first study to assess plasma glucose values as an indicator of stress response to evaluate variation and the effect of reproductive activity for wild adult red drum in Florida. Red drum (n=126) were collected from NASA's Kennedy Space Center waters during three reproductive periods in 2011. Samples were obtained from the branchial vessels of the gill arch. Plasma glucose levels were significantly different among reproductive periods, with the highest mean values recorded during the spawning period, September- October (38.23 mg / dL +/- 10.0). The glucose range was 17 - 69 mg / dL. Glucose values were lower during all three periods than previous values recorded for cultured or captive red drum studies. This may indicate that fish from this population were under less stress than other populations previously sampled.

the first study to assess plasma glucose values↗

Perfluorinated Alkyl Acids in Plasma of American Alligators (Alligator Mississippiensis) from Florida and South Carolina

This study aimed to quantitate fourteen perfluoroalkyl acids (PFAAs) in 125 adult American alligators at twelve sites across the southeastern US. Of those fourteen PFAAs, nine were detected in 65% - 100% of the samples: PFOA, PFNA, PFDA, PFUnA, PFDoA, PFTriA, PFTA, PFHxS, and PFOS. Males (across all sites) showed significantly higher concentrations of four PFAAs: PFOS (p = 0.01), PFDA (p = 0.0003), PFUnA (p = 0.021), and PFTriA (p = 0.021). Concentrations of PFOS, PFHxS, and PFDA in plasma were significantly different among the sites in each sex. Alligators at Merritt Island National Wildlife Refuge and Kiawah Nature Conservancy both exhibited some of the highest PFOS concentrations (medians 99.5 ng/g and 55.8 ng/g respectively) in plasma measured to date in a crocodilian species. A number of positive correlations between PFAAs and snout-vent length (SVL) were observed in both sexes suggesting PFAA body burdens increase with increasing size. In addition, several significant correlations among PFAAs in alligator plasma may suggest conserved sources of PFAAs at each site throughout the greater study area. This study is the first to report PFAAs in American alligators, reveals potential PFAA hot spots in Florida and South Carolina, and provides and additional contaminant of concern when assessing anthropogenic impacts on ecosystem health.

crocodilians↗