Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Fires and Smoke Observed from the Earth Observing System MODIS Instrument: Products, Validation, and Operational Use

The MODIS sensor, launched on NASA's Terra satellite at the end of 1999, was designed with 36 spectral channels for a wide array of land, ocean, and atmospheric investigations. MODIS has a unique ability to observe fires, smoke, and burn scars globally. Its main fire detection channels saturate at high brightness temperatures: 500 K at 4 microns and 400 K at 11 microns, which can only be attained in rare circumstances at the I kin fire detection spatial resolution. Thus, unlike other polar orbiting satellite sensors with similar thermal and spatial resolutions, but much lower saturation temperatures (e.g. AVHRR and ATSR), MODIS can distinguish between low intensity ground surface fires and high intensity crown forest fires. Smoke column concentration over land is for the first time being derived from the MOMS solar channels, extending from 0.41 microns to 2.1 microns. The smoke product has been provisionally validated both globally and regionally over southern Africa and central and south America. Burn scars are observed from MODIS even in the presence of smoke, using the 1.2 to 2.1 micron channels. MODIS burned area information is used to estimate pyrogenic emissions. A wide range of these fire and related products and validation are demonstrated for the wild fires that occurred in northwestern United States in the summer of 2000. The MODIS rapid response system and direct broadcast capability is being developed to enable users to obtain and generate data in near real time. It is expected that health and land management organizations will use these systems for monitoring the occurrence of fires and the dispersion of smoke within two to six hours after data acquisition.

Kaufman, Y. J.↗

Forest Understory Fire in the Brazilian Amazon in ENSO and Non-ENSO Years: Area Burned and Committed Carbon Emissions

"Understory fires" that burn the floor of standing forests are one of the most important types of forest impoverishment in the Amazon, especially during the severe droughts of El Nino Southern Oscillation (ENSO) episodes. However, we are aware of no estimates of the areal extent of these fires for the Brazilian Amazon and, hence, of their contribution to Amazon carbon fluxes to the atmosphere. We calculated the area of forest understory fires for the Brazilian Amazon region during an El Nino (1998) and a non El Nino (1995) year based on forest fire scars mapped with satellite images for three locations in eastern and southern Amazon, where deforestation is concentrated. The three study sites represented a gradient of both forest types and dry season severity. The burning scar maps were used to determine how the percentage of forest that burned varied with distance from agricultural clearings. These spatial functions were then applied to similar forest/climate combinations outside of the study sites to derive an initial estimate for the Brazilian Amazon. Ninety-one percent of the forest area that burned in the study sites was within the first kilometer of a clearing for the non ENSO year and within the first four kilometers for the ENSO year. The area of forest burned by understory forest fire during the severe drought (ENSO) year (3.9 millions of hectares) was 13 times greater than the area burned during the average rainfall year (0.2 million hectares), and twice the area of annual deforestation rate. Dense forest was, proportionally, the forest area most affected by understory fires during the El Nino year, while understory fires were concentrated in transitional forests during the year of average rainfall. Our estimate of aboveground tree biomass killed by fire ranged from 0.06 Pg to 0.38 Pg during the ENSO and from 0,004 Pg to 0,024 Pg during the non ENSO.

Alencar, A.↗

NASA 2007 Western States Fire Missions (WSFM)

This viewgraph presentation describes the Western states Fire Missions (WSFM) that occurred in 2007. The objectives of this mission are: (1) Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. (1) Demonstrate long-endurance mission capabilities (20-hours+). (2) Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. (3) Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. (4) Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. (5) Deliver real-time imagery to (within 10-minutes of acquisition). (6) Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).

Buoni, Greg↗

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗

Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher

A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.

Butz, James R.↗

Environmentally Safer, Less Toxic Fire-Extinguishing Agents

Fire-extinguishing agents comprising microscopic drops of water microencapsulated in flame-retardant polymers have been proposed as effective, less toxic, non-ozone-depleting, non-globalwarming alternatives to prior fire-extinguishing agents. Among the prior fire-extinguishing agents are halons (various halocarbon fluids), which are toxic and contribute both to depletion of upperatmospheric ozone and to global warming. Other prior fire-extinguishing agents are less toxic and less environmentally harmful but, in comparison with halons, are significantly less effective in extinguishing fires. The proposal to formulate new waterbased agents is based on recent success in the use of water mist as a fire-suppression agent. Water suppresses a flame by reducing the flame temperature and the concentration of oxygen available for the combustion process. The temperature is reduced because the water droplets in the mist absorb latent heat of vaporization as they evaporate. The concentration of oxygen is reduced because the newly generated water vapor displaces air. Unfortunately, water mists are difficult to produce in confined spaces and can evaporate before they reach the bases of flames. The proposal addresses both of these issues: The proposed fire-extinguishing agents would be manufactured in microencapsulated form in advance, eliminating the problem of generating mists in confined spaces. Because of the microencapsulation, the droplets would not evaporate until exposed directly to the heat of flames. In addition, the proposal calls for the introduction of free radicals that would inhibit the propagation of the chemical reactions of the combustion reactions. Manufacturing of a fire-extinguishing agent according to the proposal would begin with the formulation of a suitable polymer (e.g., a polybromostyrene) that would contribute free radicals to the combustion process. The polymer would be dissolved in a suitable hydrocarbon liquid (e.g., toluene). Water would be dispersed in the polymer/toluene solution, then another hydrocarbon liquid (e.g., hexane) that is not a solvent for the polymer would be added to the mixture to make the dissolved polymer precipitate onto the water droplets. The resulting polymer-coated droplets would be removed from the coating mixture by filtration, dried, and stored for use.

Parrish, Clyde F.↗

A Pan-Tropical Cascade of Fire Driven by El Nino/Southern Oscillation

The El Nino/Southern Oscillation (ENSO) has a pronounced influence on year-to-year variations in climate. The response of fires to this forcing is complex and has not been evaluated systematically across different continents. Here we use satellite data to create a climatology of burned-area and fire emissions responses, drawing on six El Nino and six La Nina events during 1997-2016. On average, reductions in precipitation and terrestrial water storage increased fire emissions in pan-tropical forests by 133% during and following El Nino as compared with La Nina. Fires peaked in equatorial Asia early in the ENSO cycle when El Nino was strengthening (Aug-Oct), before moving to southeast Asia and northern South America (Jan-Apr), Central America (Mar-May) and the southern Amazon (Jul-Oct) during the following year. Large decreases in fire occurred across northern Australia during Sep-Oct of the second year from a reduced fuel availability. Satellite observations of aerosols and carbon monoxide provided independent confirmation of the spatiotemporal evolution of fire anomalies. The predictable cascade of fire across different tropical continents described here highlights an important time delay in the Earth system's response to precipitation redistribution. These observations help to explain why the growth rate of atmospheric CO2 increases during El Nino and may contribute to improved seasonal fire forecasts.

Chen, Yang↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crew members will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crew member breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry- Laboratory at the NASA Lyndon B. Johnson Space Center. Many of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, ammonia (NH3), and acetaldehyde. A fire cartridge is exposed to the test gas in a chamber at the specified conditions, and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work and will then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the challenge tests, a general summary of the performance of the fire cartridges will also be provided.

Cristina M. Muko↗

The MacArthur Maze Fire and Roadway Collapse: Consequences for SNF Transportation - 12476

In 2007, a severe transportation accident occurred near Oakland, California, on a section of Interstate 880 known as the 'MacArthur Maze', involving a tractor trailer carrying gasoline which impacted an overpass support column and burst into flames. The subsequent fire caused the collapse of portions of the Interstate 580 overpass onto the remains of the tractor-trailer in less than 20 minutes, due to a reduction of strength in the structural steel exposed to the fire. The US Nuclear Regulatory Commission is in the process of examining the impacts of this accident on the performance of a spent nuclear fuel transportation package, using detailed analysis models, in order to determine the potential regulatory implications related to the safe transport of spent nuclear fuel in the United States. This paper will provide a summary of this effort and present results and conclusions. The detailed thermal models of the MacArthur Maze fire scenario with ANSYS and COBRASFS have produced preliminary results indicating that in a fire of this severity, the peak fuel cladding temperature would almost certainly exceed the short-term limit of 570 deg. C (1058 deg. F), and would likely exceed the Zircaloy burst temperature limit of 750 deg. C (1382 deg. F) assumed in previous transportation studies. Additional work is needed to refine and verify some of the details of these complex models, but the overall results are consistent with previous fire analyses with similar models, and with the results obtained for the HAC fire evaluations with these models. These results as well as future results produced by these models can therefore be considered as reliable estimates of the temperatures that would be experienced in fire conditions of the severity of the MacArthur Maze fire scenario. The structural analyses show that the GA-4 package is robust enough to withstand the impact of the overhead span without suffering major damage or deformation to the containment boundary. The greatest potential for local package damage in this scenario appears to be at the bolted closure end. The thermal expansion response of the closure bolts and impact limiter attachment bolts were evaluated in a separate analysis, and it was determined that both the lid and impact limiters are expected to remain in place. The response of the closure seal is currently being evaluated separately in the context of the accident's overall potential to release radioactive material in the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Speciation and Aqueous Dissolution of Macronutrients in Fire Ash: Variation across Ecosystems and the Effects on Nutrient Cycling

This study investigated the speciation and aqueous dissolution of macronutrients in fire ash from diverse ecosystems and speciation of ash and smoke from laboratory burning, exploring the variations and their causes. The speciation of phosphorus (P), calcium (Ca), and potassium (K) in fire ash from five globally distributed ecosystems was characterized by using X-ray absorption spectroscopy and sequential fractionation. Aqueous dissolution of the macronutrients was measured by batch experiments at acidic and alkaline pHs. The results showed that P existed mainly as Ca phosphates, Ca as double carbonates, calcite, and sulfates, and most K was associated with Ca carbonates. Mineralogy and the relative abundance of the species were primarily controlled by elemental stoichiometry and fire temperature. Differences in Ca and P speciation existed between ash and smoke from laboratory burning, possibly caused by the temperature difference and/or mass fractionation during burning. The rates, extents, and pH dependencies of macronutrient dissolution differed among macronutrients and depended on their speciation, with K being highly soluble and the P and Ca regulated by solution pH. The variability in ash macronutrient chemistry and ecosystemspecific fire ash loads resulted in varying loads and availability of individual macronutrient from fire among ecosystems. This study provides a mechanistic understanding of how fires transform the chemistry of macronutrients and affect macronutrient returns to soils across different ecosystems, which is essential for evaluating the disturbance to ecosystem nutrient cycling by fires.

54 ENVIRONMENTAL SCIENCES↗

Evaluating crown scorch predictions from a computational fluid dynamics wildland fire simulator

Abstract Background Crown scorch—the heating of live leaves, needles, and buds in the vegetative canopy to lethal temperatures without widespread combustion—is one of the most common fire effects shaping post-fire canopies. Despite the ability of computational fluid dynamic models to finely resolve fire activity and buoyant plume dynamics including heterogenous 3D distributions of forest canopy heating, these models have had only limited use in simulating fire effects and have not been used to evaluate crown scorch. Here, we demonstrate a method of evaluating crown scorch using a computational fluid dynamics model, FIRETEC, and validate this approach by simulating the experiments that were used to develop Van Wagner’s 1973 crown scorch model. Results The average scorch height prediction from FIRETEC compares well with the empirical model derived by Van Wagner, which is the most widely used empirical model for crown scorch. We further find that the 3D buoyant plume dynamics from a steady and homogeneous idealized heat source on the ground results in a spatially heterogenous crown scorch pattern reflecting complex heating dynamics that are best represented by percent scorch rather than height of scorch. Conclusions The ability of the computational fluid dynamics model to capture variation in crown scorch due to 3D buoyant plume dynamics provides direct links between forest structure, fire behavior, and fire effects that can be used by forest managers and researchers to better understand how fires result in crown damage under various environmental and management scenarios.

54 ENVIRONMENTAL SCIENCES↗

Assessment of core damage frequency owing to possible fires at NPP with RBMK type reactors

According to Scientific and Technical Cooperation between the USA and Russia in the field of nuclear engineering the Idaho National Laboratory has transferred to the possession of the National Research Center ' Kurchatov Inst. ' the SAPHIRE software without any fee. With the help of the software Kurchatov Inst. developed a Pilot Living PSA- Model of Leningrad NPP Unit 1. Computations of core damage frequencies were carried out for additional Initiating Events. In the submitted paper such additional Initiating Events are fires in various compartments of the NPP. During the computations of each fire, structure of the PSA - Model was not changed, but Fault Trees for the appropriate systems, which are removed from service during the fire, were changed. It follows from the computations, that for ten fires Core Damaged Frequencies (CDF) are not changed. Other six fires will cause additional core damage. On the basis of the calculated results it is possible to determine a degree of importance of these fires and to establish sequence of performance of fire-prevention measures in various places of the NPP. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automated Fire Detection for Industrial Settings with Pretrained Convolutional Networks

Early fire detection in industrial environments is critical to preventing equipment damage, personal injury, and operational disruptions. Traditional smoke detectors, while effective, often experience delays due to the time required for smoke to reach sensors, allowing fires to spread. Manual fire watch operations and human surveillance of camera feeds are resource-intensive and prone to human error. To address these challenges, this paper explores the application of convolutional neural networks for automated fire detection, specifically in industrial settings. By leveraging 11 different pre-trained machine vision models from TensorFlow and enhancing them with transfer learning on a custom-built industrial fire dataset, we optimized fire detection performance. Here, we analyzed each machine vision model architecture in terms of its depth, width, and input image resolution, considering both resource requirements and detection accuracy. We further explored the option of combining multiple models into an ensemble classifier to evaluate whether the performance improvements could justify the much greater computational complexity and other practical impacts. A cost-benefit analysis is presented to evaluate the trade-offs between performance and computational expense. Our findings identify that EfficientNetV2L, specifically tailored for industrial applications, provides the optimal balance between costs involved in training and using the model versus the overall fire detection performance. Additionally, we present a qualitative analysis of model performance using the technique of gradient-based class activation mapping to provide explainability by visualizing model decisions.

artificial intelligence↗

Numerical investigation of mixing and heat transfer in a 7.9 m JP-8 pool fire

The response of objects engulfed in, and adjacent to, large-scale pool fires is of interest in accident and safety assessments. In this study, Fuego, a low-Mach turbulent reacting flow code was used to study conjugate heat transfer in a 7.9 m diameter JP-8 pool fire. Simulations were designed to replicate past experimental measurements (Blanchat et al., 2006) of incident heat flux to three cylindrical calorimeters in and around the pool fire. Two turbulent combustion models were compared directly - the eddy dissipation concept and a more recently developed unsteady flamelet model. First and second order spatial and temporal discretization schemes were also compared to assess the performance of low-dissipation numerical operators. Heat flux predictions to the transportation size calorimeter outside the fire were within experimental uncertainties. Inside the fire, experimental measurements were higher than predicted values and may have been a consequence of soot deposition and augmented participating media radiation from soot and fuel vapor. Simulation predictions improved in cases where turbulent kinetic energy and mixing were more resolved. This work, and others referenced herein, suggest that spatial resolution on the order of 0.5–1.0 cm may be required to fully resolve fluid instabilities, vortex production between fire plumes and crosswind, soot production, and fuel-air mixing. This presents a substantial computational challenge for safety assessments of engulfed objects in fully turbulent pool fires.

Conjugate heat transfer↗

Effects of overstory composition and prescribed fire on fuel loading across a heterogeneous managed landscape in the southeastern USA.

In the southeastern USA, land use history, forest management and natural geomorphic features have created heterogeneous fuel loads. This apparent temporal and spatial variation in fuel loads make it difficult to reliably assess potential fire behavior from remotely sensed canopy variables to determine risk and to prescribe treatments. We examined this variation by exploring the relationships between overstory forest vegetation attributes, recent fire history, and selected surface fuel components across an 80,000 ha contiguous landscape. Measurements of dead and live vegetation components of surface fuels were obtained from 624 permanent plots, or about 1 plot per 100 ha of forest cover. Within forest vegetation groups, we modeled the relationship between individual surface fuel components and overstory stand age, basal area, site quality and recent fire history, then stochastically predicted fuel loads across the landscape using the same linkage variables. The fraction of the plot variation, i.e., R2, explained by predictive models for individual fuel components ranged from 0.05 to 0.66 for dead fuels and 0.03 to 0.97 for live fuels in pine dominated vegetation groups. Stand age and basal area were generally more important than recent fire history for predicting fuel loads. Mapped fuel loads using these regressor variables showed a very heterogeneous landscape even at the scale of a few square kilometers. The mapped patterns corresponded to stand based forest management disturbances that are reflected in age, basal area, and fire history. Recent fire history was significant in explaining variation in litter and duff biomass. Stand basal area was positively and consistently related to dead fuel biomass in most groups and was present in many predictive equations. Patterns in live fuel biomass were related to recent fire history, but the patterns were not consistent among forest vegetation groups. Age and basal area were related to live fuels in a complex manner that is likely confounded with periodic disturbances that disrupt stand dynamics. This study complements earlier hazardous fuels research in the southeastern USA, and indicates that succession, disturbance, site quality and decomposition interact with forest management practices to create variable spatial and temporal conditions. The inclusion of additional land use, disturbance history, and soil-topographic variables coupled to improved sampling methods may increase precision and subsequent fuel mapping.

09 BIOMASS FUELS↗

Application of petrographic examination techniques to the assessment of fire-damaged concrete and masonry structures

The number of building fires has doubled over the last 50 years. There has never been a greater need for structures to be assessed for fire damage to ensure safety and enable appropriate repairs to be planned. Fortunately, even after a severe fire, concrete and masonry structures are generally capable of being repaired rather than demolished. By allowing direct examination of microcracking and mineralogical changes, petrographic examination has become widely used to determine the depth of fire damage for reinforced concrete elements. Petrographic examination can also be applied to fire-damaged masonry structures built of materials such as stone, brick and mortar. Petrography can ensure accurate detection of damaged geomaterials, which provides cost savings during building repair and increased safety reassurance. This paper comprises a review of the role of petrography in fire damage assessments, drawing on a range of actual fire damage investigations.

36 MATERIALS SCIENCE↗

Fire effects on the persistence of soil organic matter and long-term carbon storage

One paradigm in biogeochemistry is that frequent disturbance tends to deplete carbon (C) in soil organic matter (SOM) by reducing biomass inputs and promoting losses. However, disturbance by fire has challenged this paradigm because soil C responses to frequent and/or intense fires are highly variable, despite observed declines in biomass inputs. Here, we review recent advances to illustrate that fire-driven changes in decomposition, mediated by altered SOM stability, are an important compensatory process offsetting declines in aboveground biomass pools. Fire alters the stability of SOM by affecting both the physicochemical properties of the SOM and the environmental drivers of decomposition, potentially offsetting C lost via combustion, but the mechanisms affecting the SOM stability differ across ecosystems. Thus, shifting our focus from a top-down view of fire impacting C cycling via changes in plant biomass to a bottom-up view of changes in decomposition may help to elucidate counterintuitive trends in the response of SOM to burning. Finally, given that 70% of global topsoil C is in fire-prone regions, using fire to promote SOM stability may be an important nature-based climate solution to increase C storage.

54 ENVIRONMENTAL SCIENCES↗

Fire affects the taxonomic and functional composition of soil microbial communities, with cascading effects on grassland ecosystem functioning

Fire is a crucial event regulating the structure and functioning of many ecosystems. Yet few studies have focused on how fire affects taxonomic and functional diversities of soil microbial communities, along with changes in plant communities and soil carbon (C) and nitrogen (N) dynamics. Here, we analyze these effects in a grassland ecosystem 9 months after an experimental fire at the Jasper Ridge Global Change Experiment site in California, USA. Fire altered soil microbial communities considerably, with community assembly process analysis showing that environmental selection pressure was higher in burned sites. However, a small subset of highly connected taxa was able to withstand the disturbance. In addition, fire decreased the relative abundances of most functional genes associated with C degradation and N cycling, implicating a slowdown of microbial processes linked to soil C and N dynamics. In contrast, fire stimulated above- and belowground plant growth, likely enhancing plant-microbe competition for soil inorganic N, which was reduced by a factor of about 2. To synthesize those findings, we performed structural equation modeling, which showed that plants but not microbial communities were responsible for significantly higher soil respiration rates in burned sites. Together, our results demonstrate that fire 'reboots' the grassland ecosystem by differentially regulating plant and soil microbial communities, leading to significant changes in soil C and N dynamics.

54 ENVIRONMENTAL SCIENCES↗