Grain Boundary Diffusion Characterized by KPFM

Materials aging is a high-consequence failure mode in electronic systems. Such mechanisms can degrade the electrical properties of connectors, relays, wire bonds, and other interconnections. Lost performance will impact, not only that of the device, but also the function and reliability of next-level assemblies and the weapons system as a whole. The detections of changes to materials surfaces at the nanometer-scale resolution, provides a means to identify aging processes at their early stages before they manifest into latent failures that affect system-level performance and reliability. Diffusion will be studied on thin films that undergo accelerated aging using the nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM). The KPFM provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer spatial resolution of surface chemistry changes. The KPFM method can provide the means to measure surface, and near-surface, elemental concentrations that allow the determination of diffusion rate kinetics. These attributes will be illustrated by assessing diffusion in a thin film couple. Validation data will obtained from traditional techniques: (a) Auger electron spectroscopy (AES), x-ray fluorescence (XRF), and xray photoelectron spectroscopy (XPS).

36 MATERIALS SCIENCE↗

Digital Signal Processing of Radar Pulse Echoes

Modern high-performance radar systems are employing ever-more Digital Signal Processing (DSP), replacing ever-more formerly analog components. Precisely predicting the performance of digital filters and correlators requires an awareness of some of the finer points and characteristics of digital filters. We examine a representative radar receiver DSP chain that is processing a Linear Frequency Modulated (LFM) chirp.

47 OTHER INSTRUMENTATION↗

Grain Boundary Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a preliminary diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer spatial resolution of surface chemistry changes and will be exercised in an effort to explore its capacity to map surface potential contrast caused by Cu diffusion in a manner that allows for a qualitative assessment of diffusion rate kinetics. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of Ti or Cr/Cu/Au layer thicknesses of 50nm/500nm/500nm up to 4μm respectively. The accelerated aging process, was performed in air at aging temperatures of 60°C, 100°C, and 125°C for aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days). A calibration method was developed using Au, Al and Ni standards to establish precision and repeatability of the KPFM technique. Average CPDs and standard deviations for each metal were found and summarized.

36 MATERIALS SCIENCE↗

Recovery and calibration of legacy analog data from the Leo Brady Seismic Network for the Source Physics Experiment

The Leo Brady Seismic Network (LBSN) was established in 1960 by Sandia National Laboratories for monitoring underground nuclear tests (UGTs) at the Nevada Test Site— renamed in 2010 to the Nevada National Security Site (NNSS). The LBSN has been in various configurations throughout its existence, but it has been generally comprised of four to six stations at regional distances from the NNSS with evenly spaced azimuthal coverage. Between 1962 and the early 1980s, the LBSN—and a sister network operated by Lawrence Livermore National Laboratory—were the most comprehensive U.S. source of regional seismic data of UGTs. During the pre-digital era, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to the NTS and recorded in analog on hi-fi 8-track AMPEX tapes. These tapes have been stored in temperature-stable buildings or bunkers on the NNSS and Kirtland Air Force Base in Albuquerque, NM for decades and contain the sole record of this irreplaceable data from the analog era; full waveforms of UGTs during this time were never routinely converted to digital form. We have been developing a process over the past few years to recover and calibrate data from these tapes, converting them from FM audio to digital waveforms in ground motion units. The calibration of legacy data from the LBSN is still ongoing. To date, we have digitized tapes from 592 separate UGTs. As a proof-of-concept, we calibrated data from the BOXCAR event.

58 GEOSCIENCES↗

Cu/Al Through Au Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. The KPFM technique will be exercised in an effort to explore its capacity to map surface potential contrast caused by diffusion in a manner that allows for a qualitative assessment of diffusion of Cu or Al through Au. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of 500nm Cu or Al then 500nm Au on Si. The accelerated aging process was performed under inert conditions at aging temperatures of 100°C for Cu/Au film stack and 175°C for Al/Au film stack at aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days).A calibration method was developed using Au, Al and Cu standards to establish precision and repeatability of the KPFM technique. The average Contact Potential Difference (CPD)s and standard deviations for each metal were found and summarized. Averages from surface roughness of the AFM topography images and roughness analysis of KPFM potential images which yield an average CPD of each area of unaged vs aged coupon surfaces were compared and show trends that indicate surface chemistry.

36 MATERIALS SCIENCE↗

DATASET RELEASE AND QUALITY CONTROL REVIEW OF LIVERMORE NEVADA NETWORK (LNN) RECORDINGS OF A SUBSET OF NEVADA NUCLEAR SECURITY SITE NUCLEAR EXPLOSIONS FROM 1979 TO 1992.

Geophysical research on historical nuclear tests is an important aspect of future monitoring capabilities in seismic research. This research is challenging due to the limited number of digital seismic recordings during the peak of nuclear testing (1945-1992). These limited records are unique and non-reproducible data with potential high research impact. Releasing available nuclear explosion seismic records to the explosion monitoring community is thus of high value and is the motivation for this dataset release. The target of this effort was on compilation and quality control of regional seismic records of nuclear explosions recorded on Lawrence Livermore National Laboratory stations ELK, KNB, LAC, and MNV, known collectively as the Livermore National Network (LNN) (Figure 1). LNN was established in the early 1960s for the primary purpose of monitoring underground nuclear testing at the former Nevada Test Site (NTS), now known as the Nevada Nuclear Security Site (NNSS) following the signing of the Limited Test Ban Treaty (LTBT). LNN consisted initially of short-period vertical component Benioff’s recorded on film located at Mina, NV (MNV) and Kanab, Utah (KNB). LNN added two additional stations at Landers, CA (LAC) and Elko, NV (ELK) in 1967 and upgraded equipment to broadband seismometers recorded on frequency modulation (FM) tapes from 1967-1979, followed by digital recordings after 1979 (Jarpe, 1989). The digital recordings were on a variety of now obsolete media, including 9-track, Exabyte, and DAT tapes. Jarpe (1989) describes the seismic station instrumentation details over the period of deployment. LNN recorded valuable non-repeatable unique data of several hundreds of nuclear explosions at NNSS, as well as earthquakes and chemical and mining explosions (Walter, 2020). The details of these nuclear tests are provided in the Department of Energy Report NV-209 Rev 16 (DOE, 2015).

58 GEOSCIENCES↗

Transmission Line Based Sensor Design for FMCW Radar Processing of Collision Damage

This report presents a framework for transmission line ( T-L ) sensor design in Frequency Modulated Continuous Wave (FMCW) radar applications, with particular emphasis on modeling collision damage effects. Classical electromagnetic (EM) propagation theory is combined with impact mechanics to develop a model for analyzing transmission line behavior as a sensor under high-velocity impact conditions. The framework includes detailed mathematical derivations, spatial and temporal damage evolution models, and practical implementation considerations.

42 ENGINEERING↗

Optical gas monitor

A frequency modulated spectroscopy system, including a photo-detector, a band-pass filter to filter the output of the photo-detector, and a rectifier to demodulate. The band-pass filter has a relatively high Q factor. With the high Q factor band-pass filter and rectifier, a reference sinusoid is not required for demodulation, resulting in phase-insensitive spectroscopy. Other embodiments are described and claimed.

Wu, Sheng↗

Generating nonlinear FM chirp radar signals by multiple integrations

A phase component of a nonlinear frequency modulated (NLFM) chirp radar pulse can be produced by performing digital integration operations over a time interval defined by the pulse width. Each digital integration operation includes applying to a respectively corresponding input parameter value a respectively corresponding number of instances of digital integration.

42 ENGINEERING↗

Method and system for controlling the position of a beam of light

An method and system for laser beam tracking and pointing is based on a conventional position sensing detector (PSD) or quadrant cell but with the use of amplitude-modulated light. A combination of logarithmic automatic gain control, filtering, and synchronous detection offers high angular precision with exceptional dynamic range and sensitivity, while maintaining wide bandwidth. Use of modulated light enables the tracking of multiple beams simultaneously through the use of different modulation frequencies. It also makes the system resistant to interfering light sources such as ambient light. Beam pointing is accomplished by feeding back errors in the measured beam position to a beam steering element, such as a steering mirror. Closed-loop tracking performance is superior to existing methods, especially under conditions of atmospheric scintillation.

47 OTHER INSTRUMENTATION↗

Application of a tunable-diode-laser absorption diagnostic for CO measurements in an automotive HCCI engine.

An infrared laser absorption technique has been developed to measure in-cylinder concentrations of CO in an optical, automotive HCCI engine. The diagnostic employs a distributed-feedback, tunable diode laser selected to emit light at the R15 line of the first overtone of CO near 2.3 {micro}m. The collimated laser beam makes multiple passes through the cylinder to increase its path length and its sampling volume. High-frequency modulation of the laser output (wavelength modulation spectroscopy) further enhances the signal-to-noise ratio and detection limits of CO. The diagnostic has been tested in the motored and fired engine, exhibiting better than 200-ppm sensitivity for 50-cycle ensemble-average values of CO concentration with 1-ms time resolution. Fired results demonstrate the ability of the diagnostic to quantify CO production during negative valve overlap (NVO) for a range of fueling conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Quasiclassical Computations of Compton-Scattered Spectra

Quality X-ray sources are crucial to fundamental physics research, medical radiology, humanities research, and materials science. While synchrotron radiation (SR) facilities produce the state-of-the-art emissions with respect to brilliance and frequency tunability, the great expense required to build, maintain, and operate these structures greatly limits their accessibility to researchers. Much of the research conducted at SR facilities, however, may be conducted with inverse Compton sources (ICS). Accelerator-based Compton scattering light sources generate high-energy, high-brilliance emissions. Compton scattering is the process by which a photon scatters o? an electron. ICS offer an affordable, in-lab alternative to SR facilities. Even though SR facilities produce greater intensity emissions, Compton sources provide the same frequency tunability at the intensities suitable for the purposes of many researchers currently fighting for time at SR facilities, i.e., ICS provides intensities suitable for contrast imaging, X-ray fluorescence, X-ray-diffraction, and X-ray spectroscopy. The focus of this work is to create computational models to simulate Compton-scattered spectra. These models have been used to build a theoretical basis for methods of improving the quality of future Compton sources and to preform diagnostic analysis of existing light sources. The theoretical basis of each model is derived from first principles. The numerical methods employed by each model are defined. A full description of the various functionalities of each code will be addressed. Furthermore, an in-depth analysis of spectral bandwidth sources is discussed. The complex physics arising from an extremely high-intensity, nonlinear laser pulse is explored in detail. Methods of frequency modulation of the incident laser, i.e., a method for correcting the nonlinear broadening effects on the scattered spectrum, will also be discussed. The work will conclude with a an exploration of the ongoing research efforts regarding regimes of operation outside of the limits of these current models.

Johnson, Erik↗

Thermal Diffusivity Measurement of Irradiated SiC-SiC Composite Material

Silicon Carbide fiber and matrix composite (SiC-SiC) is being considered as a fuel cladding candidate because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. The thermal properties of SiC-SiC composite depend heavily on the fabrication process, thus cannot be simply referenced from available database. Similarly, the influence of irradiation on SiC-SiC composite thermal properties needs to be measured to provide general trends of property degradation. For ion irradiated samples, the damaged layer is only a few to a few tens of micrometers. It is impossible to directly measure the bulk property change of a SiC-SiC composite because of the thin, damaged layer. This paper focuses on a methodology that is based on microscale measurement of fiber and matrix properties to determine the overall bulk property change due to ion irradiation. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the phase lag of the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, a new measurement approach of SiC-SiC composite thermal diffusivity is presented. Due to the micrometer spatial resolution of the photothermal reflectance technique, the measurements are performed locally on fibers along both radial and axial directions, and on the matrix. The influence of Silicon ion irradiation (75 MeV, 10 dpa) is then examined by comparing the experimental results of samples before and after irradiation. (authors)

36 MATERIALS SCIENCE↗

Comparison of Thermal Diffusivity Degradation of Irradiated Zirlo and SiC-SiC Composite

Zirlo (Zircaloy cladding material from Westinghouse) has been widely used as the fuel cladding material in Light Water Reactors because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. But as Zirlo reacts with water at high temperature, which can trigger serious accidents, efforts have been made to explore better candidates to replace Zirlo in the water-cooled reactors. SiC-SiC composite is considered as one of the most viable options due to its comparable mechanical performances and corrosion resistance. However, one of the most important properties, thermal diffusivities of both Zirlo and SiC-SiC composite, and their degradation after irradiation, are not well known yet. Ion-irradiated samples are used to study the thermal property degradation caused by irradiation instead of the neutron-irradiated ones due to the significantly lower radioactivity. The microstructural damage is estimated from the software simulation SRIM/TRIM based on the energy and fluence of the ion, and the target material, and represented by DPA (displacement by atom). Different from neutron-irradiated samples, the damaged layer of ion-irradiated samples is only a few to a few tens of micrometers thick, and the damage is depth dependent. It is impossible to directly measure the bulk property change, and a microscale measurement technique is necessary. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag of the thermal wave, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, thermal diffusivity of the light damage layer of the post-irradiation Zirlo and SiC-SiC composite are measured and compared. The Zirlo sample is irradiated by Ni{sup 9+} ion, and SiC-SiC composite material is irradiated by Si{sup 7+} ion. The peak DPA of both sample is similar as ∼10. For ion-irradiated materials, DPA is known to increase with depth before it reaches the peak, and then sharply drop to zero. In term of light damage layer in this manuscript, we mean by the layer with a DPA smaller than 5% maximum value. In this layer DPA increases slowly and smoothly with depth, and the structure and thus thermal properties are more spatially uniform. For the SiC-SiC composite, the measurements are separately conducted on fibers along radial or axial direction, and on the matrix. Our measurement results show that with similar microstructural damage, thermal diffusivity of matrix SiC reduces more significantly than that of Zirlo. For fiber SiC that has a much lower thermal diffusivity than the matrix SiC before irradiation, the post-irradiation effect on thermal diffusivity is not obvious.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Low-Cost, Reconfigurable UWB Microwave Radar Front-End for Fine Resolution Nadir-Looking Measurements of Snow and Layered Media

This paper presents a reconfigurable, low-cost ultra-wideband microwave radar front-end and radar demonstrator designed for nadir-looking measurements of layered media (e.g. snow or vegetation) from either a fast-moving ground-based platform or a C-3 class unmanned aerial system (UAS). The radar demonstrator uses a frequency modulated continuous-wave (FMCW) architecture and can be configured to operate in either the 2-8 GHz or in the 12-18 GHz range, providing fine vertical resolution while offering a significantly reduced weight, size, and power consumption with respect to prior implementations. We have demonstrated the operation of the system in the 2-8 GHz and 12-18 GHz bands in the laboratory; in the 2-8 GHz band using a surface-based setup in Antarctica; and in the 2.6-7 GHz band on local flight tests onboard an Aurelia X6 Pro UAS equipped with 3-D printed antennas. This paper provides an overview of the radar front-end and demonstrator design and implementation and a summary of the different tests completed to document their performance.

UWB radar, UAS-borne radar, snow-probing radar.↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Destructive Evaluation of Grain Structure Using Air-Coupled Ultrasonics

Cast material has a grain structure that is relatively non-uniform. There is a desire to evaluate the grain structure of this material non-destructively. Traditionally, grain size measurement is a destructive process involving the sectioning and metallographic imaging of the material. Generally, this is performed on a representative sample on a periodic basis. Sampling is inefficient and costly. Furthermore, the resulting data may not provide an accurate description of the entire part's average grain size or grain size variation. This project is designed to develop a non-destructive acoustic scanning technique, using Chirp waveforms, to quantify average grain size and grain size variation across the surface of a cast material. A Chirp is a signal in which the frequency increases or decreases over time (frequency modulation). As a Chirp passes through a material, the material's grains reduce the signal (attenuation) by absorbing the signal energy. Geophysics research has shown a direct correlation with Chirp wave attenuation and mean grain size in geological structures. The goal of this project is to demonstrate that Chirp waveform attenuation can be used to measure grain size and grain variation in cast metals (uranium and other materials of interest). An off-axis ultrasonic inspection technique using air-coupled ultrasonics has been developed to determine grain size in cast materials. The technique gives a uniform response across the volume of the component. This technique has been demonstrated to provide generalized trends of grain variation over the samples investigated.

58 GEOSCIENCES↗

Quantum driven dissipative parametric oscillator in a blackbody radiation field

We consider the general open system problem of a charged quantum oscillator confined in a harmonic trap, whose frequency can be arbitrarily modulated in time, that interacts with both an incoherent quantized (blackbody) radiation field and with an arbitrary coherent laser field. We assume that the oscillator is initially in thermodynamic equilibrium with its environment, a non-factorized initial density matrix of the system and the environment, and that at t = 0 the modulation of the frequency, the coupling to the incoherent and the coherent radiation are switched on. The subsequent dynamics, induced by the presence of the blackbody radiation, the laser field, and the frequency modulation, is studied in the framework of the influence functional approach. This approach allows incorporating, in analytic closed formulae, the non-Markovian character of the oscillator-environment interaction at any temperature as well the non-Markovian character of the blackbody radiation and its zero-point fluctuations. Expressions for the time evolution of the covariance matrix elements of the quantum fluctuations and the reduced density-operator are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗