Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FORENSIC SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Analysis of Carbohydrate and Fatty Acid Marker Abundance in Ricin Toxin Preparations for Forensic Information

One challenge in the forensic analysis of ricin samples is determining the method and extent of sample preparation. Ricin purification from the source castor seeds is essentially a protein purification through removal of the non-protein fractions of the seed. Two major, non-protein constituents in the seed are the castor oil and carbohydrates. Ricinoleic acid is a relatively unique fatty acid in nature and is the most abundant component of castor oil, which comprises roughly half the seed weight. The carbohydrate component comprises roughly half of the remaining “mash” left after oil and hull removal. We used derivatization of carbohydrate and fatty acid markers followed by identification and quantification using gas chromatography/mass spectrometry (GC/MS) to assess compositional changes in ricin samples purified by different methods. The loss of ricinoleic acid indicated steps for oil removal had occurred. Changes to the carbohydrate content of the sample were also observed following protein precipitation. The differential loss of arabinose relative to mannose indicated removal of the major carbohydrate fraction of the seed and enrichment of the protein content. Taken together, these changes in fatty acid and carbohydrate abundance are indicative of the preparation method used for each sample.

59 BASIC BIOLOGICAL SCIENCES↗

Qualification of Daiichi Units 1, 2, and 3 Data for Severe Accident Evaluations - Process and Illustrative Examples from Prior TMI-2 Evaluations

The accidents at the Three Mile Island Unit 2 (TMI-2) Pressurized Water Reactor (PWR) and the Daiichi Units 1, 2, and 3 Boiling Water Reactors (BWRs) provide unique opportunities to evaluate instrumentation exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during the TMI-2 accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This initial review focused on the set of sensors deemed most important by post-TMI-2 instrumentation evaluation programs. Instrumentation evaluation programs focused on data required by TMI-2 operators to assess the condition of the reactor and containment and the effect of mitigating actions taken by these operators. In addition, prior efforts focused on sensors providing data required for subsequent forensic evaluations and accident simulations. To encourage the potential for similar activities to be completed for qualifying data from Daiichi Units 1, 2, and 3, this report provides additional details related to the formal process used to develop a qualified TMI-2 data base and presents data qualification details for three parameters: primary system pressure; containment building temperature; and containment pressure. As described within this report, sensor evaluations and data qualification required implementation of various processes, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design to instruments easily removed from the TMI-2 plant for evaluations. As documented in this report, results from qualifying data for these parameters led to key insights related to TMI-2 accident progression. Hence, these selected examples illustrate the types of activities completed in the TMI-2 data qualification process and the importance of such a qualification effort. These details are documented in this report to facilitate implementation of similar process using data and examinations at the Daiichi Units 1, 2, and 3 reactors so that BWR-specific benefits can be obtained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A novel approach to determine post mortem interval using neutron radiography

In this study, neutron radiography (NR) is used non-destructively to measure changes in hydrogen (H) content in decaying tissues as a mean to estimate post-mortem invertal (PMI). After death, tissue undergoes sequential changes consisting of organic and inorganic phase variations, as well as a gradual reduction of tissue water content. H is the primary contributor to NR contrast in biological specimens because (1) it is the most abundant element in biological tissues and (2) its nucleus scatter thermal and cold neutrons more strongly than any other atomic nucleus. These contrast differences can be advantageous in a forensic context to determine small changes in hydrogen concentrations. Dog cadavers were used as a model for human cadavers. Canine tissues and cadavers were exposed to controlled (laboratory settings) and uncontrolled (University of Tennessee Anthropology Research Facility) environmental conditions during putefraction, respectively. Neutron radiographs were supplemented with photographs and histology data to assess the decomposition stage of cadavers. Results demonstrated that the increase in neutron transmission likely corresponded to a decrease in hydrogen content in the tissue, which was correlated with the time of decay of the tissue. Tissues depleted in hydrogen are brighter in the neutron transmission radiographs of skeletal muscles, lung, and bone, under controlled conditions. Over a period of 10 days, changes in neutron transmission through lung and muscle were found to be higher than bone by 8.3%, 7.0 %, and 2.0 %, respectively. Estimation of the PMI was calculated from a natural logarithmic fitting of the NR data. Under controlled conditions, estimation of the PMI was 70% and 63.9 % accurate for bone and lung tissues, while being 1.4% accurate for muscle tissue. All results underestimated the true PMI. In conclusion, neutron radiography can be used for detection of hydrogen changes in decaying tissues to estimate PMI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Source and Evolutionary History of a Microbial Contaminant Identified Through Soil Metagenomic Analysis

ABSTRACT In this study, strain-resolved metagenomics was used to solve a mystery. A 6.4-Mbp complete closed genome was recovered from a soil metagenome and found to be astonishingly similar to that of Delftia acidovorans SPH-1, which was isolated in Germany a decade ago. It was suspected that this organism was not native to the soil sample because it lacked the diversity that is characteristic of other soil organisms; this suspicion was confirmed when PCR testing failed to detect the bacterium in the original soil samples. D. acidovorans was also identified in 16 previously published metagenomes from multiple environments, but detailed-scale single nucleotide polymorphism analysis grouped these into five distinct clades. All of the strains indicated as contaminants fell into one clade. Fragment length anomalies were identified in paired reads mapping to the contaminant clade genotypes only. This finding was used to establish that the DNA was present in specific size selection reagents used during sequencing. Ultimately, the source of the contaminant was identified as bacterial biofilms growing in tubing. On the basis of direct measurement of the rate of fixation of mutations across the period of time in which contamination was occurring, we estimated the time of separation of the contaminant strain from the genomically sequenced ancestral population within a factor of 2. This research serves as a case study of high-resolution microbial forensics and strain tracking accomplished through metagenomics-based comparative genomics. The specific case reported here is unusual in that the study was conducted in the background of a soil metagenome and the conclusions were confirmed by independent methods. IMPORTANCE It is often important to determine the source of a microbial strain. Examples include tracking a bacterium linked to a disease epidemic, contaminating the food supply, or used in bioterrorism. Strain identification and tracking are generally approached by using cultivation-based or relatively nonspecific gene fingerprinting methods. Genomic methods have the ability to distinguish strains, but this approach typically has been restricted to isolates or relatively low-complexity communities. We demonstrate that strain-resolved metagenomics can be applied to extremely complex soil samples. We genotypically defined a soil-associated bacterium and identified it as a contaminant. By linking together snapshots of the bacterial genome over time, it was possible to estimate how long the contaminant had been diverging from a likely source population. The results are congruent with the derivation of the bacterium from a strain isolated in Germany and sequenced a decade ago and highlight the utility of metagenomics in strain tracking.

59 BASIC BIOLOGICAL SCIENCES↗

Forensic species identification of elasmobranchs landed in Costa Rican artisanal fisheries

Elasmobranchs represent one of the most imperiled taxa, yet few nations have developed catch limits and no international or bilateral catch limits exist. One barrier to establishing catch limits is a lack of accurate species-specific extraction rates due to many species looking similar, distinguishing characteristics (fins and head) being removed, or grouping of all elasmobranchs together in fisheries data. To better understand the species-specific impacts fisheries are having on elasmobranchs we used forensic genetic techniques to identify the types and quantities of shark species landed in Costa Rican artisanal small-scale and mid-scale fisheries. We collected elasmobranch tissue samples from fishermen in three locations along Costa Rica’s Pacific Coast: Coyote, Bejuco, and Ojochal, from April 2013 to September 2014. We used DNA barcoding techniques, utilizing a 1044 base pair region of the NADH dehydrogenase subunit 2 gene, to identify to species 275 of the 416 samples collected. Within these fisheries, seven species of shark and one ray were identified, with the scalloped hammerhead shark (Sphyrna lewini) accounting for ~750-80% of all sharks landed. Observed total lengths (TL) for the scalloped hammerhead shark (10.9–99 cm) in these fisheries suggests the sharks sampled were all either juveniles or neonates. Based on these data it is likely that the areas from which these samples were collected represent nursery grounds for the scalloped hammerhead shark. The quantity of young scalloped hammerhead sharks removed from these areas, and ones similar to them, by these artisanal fisheries could be of great importance when determining future conservation measures for this species. We conclude our findings also indicate that sharks caught in these artisanal fisheries do not appear to represent those sold in markets around San Jose.

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility of Using Radar for Characterizing and Tracking Plumes

With the enhanced capabilities of NEXRAD radars has come an increased body of research focused on non-weather artifacts in the radar signal. Radar data has been collected and evaluated for a range of plume-generating events. Events such as wildfires, measuring and tracking ash from volcanic eruptions, and tracking plumes from events such as the SpaceX rocket explosion in 2016 have been investigated to determine the useful measurements available in radar data. For decision makers interested in radar use in nuclear forensics or during an emergency response, the usefulness of radar for attempting to provide some answers early in an event is clear. Currently emplaced operational radars provide high spatial and temporal resolution data within minutes of an event. This is not to say radar observations would replace current methods used by decision makers; however, supplementing decision making with radar data can only enhance and better inform the decision process. This report builds on two previous reports submitted in November 2016 and May 2017. This feasibility study demonstrates that radar can be used to improve decision making in the early phases of a plume-generating event by decreasing uncertainty as well as improving source-term inputs in F&T models. Radar coverage exists today in capabilities such as NOAA’s NEXRAD weather surveillance radars and Terminal Doppler Weather Radars. Improvement could be realized quickly by (1) improving awareness of existing radar products and incorporating them into decision making and modeling efforts, (2) evaluating and improving radar coverage around key urban areas and critical infrastructure, and (3) improving radar algorithms to optimize for non-meteorological events such as plumes.

47 OTHER INSTRUMENTATION↗

The rotary zone thermal cycler: A low-power system enabling automated rapid PCR

In this study, advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, portable, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology such as aliquoting, centrifuging, mixing, and thermal cycling to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We further demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system using low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, preliminary results are presented for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis.

47 OTHER INSTRUMENTATION↗

Metal alloy microparticle tagging of UO 2 fuel pellets for nuclear forensics

A tagging strategy for UO 2 fuel pellets will be discussed which involves the creation of alloyed metal microparticles that can be tuned to create a unique identification (“barcode”) indicating provenance of the pellets. These specialized markers would contain high temperature resistant materials, such as Ti, Mo, and Cr, in small quantities such that they do not interfere with the performance of the pellets but are recoverable by standard analytical techniques. The Amazemet rePowder ultrasonic atomization system was used to manufacture the microparticles, and sample pellets were fabricated and sintered containing these dopants. Various techniques, such as Scanning Electron Microscopy (SEM) and Electron Probe Microanalysis (EPMA), were used to evaluate these sample pellets to determine if particles (and their alloy compositions) were recoverable. Details on how the particles were manufactured and characterized will be detailed, as well as results from their incorporation into test pellets. Next steps will involve the scale of this technique using more conventional mass production methods, as well as the implementation of other alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and separations. The system couples a high-resolution ion mobility (IM) drift cell to the front end of a mass spectrometer (MS) allowing for chemical separation prior to isotope distribution analyses. This will yield isotope ratio measurement capabilities with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

A global metagenomic map of urban microbiomes and antimicrobial resistance

We present a global atlas of 4,728 metagenomic samples from mass-transit systems in 60 cities over 3 years, representing the first systematic, worldwide catalog of the urban microbial ecosystem. This atlas provides an annotated, geospatial profile of microbial strains, functional characteristics, antimicrobial resistance (AMR) markers, and genetic elements, including 10,928 viruses, 1,302 bacteria, 2 archaea, and 838,532 CRISPR arrays not found in reference databases. We identified 4,246 known species of urban microorganisms and a consistent set of 31 species found in 97% of samples that were distinct from human commensal organisms. Profiles of AMR genes varied widely in type and density across cities. Cities showed distinct microbial taxonomic signatures that were driven by climate and geographic differences. These results constitute a high-resolution global metagenomic atlas that enables discovery of organisms and genes, highlights potential public health and forensic applications, and provides a culture-independent view of AMR burden in cities.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Radiocarbon, Stable Isotopes and DNA in Teeth to Facilitate Identification of Unknown Decedents

The characterization of unidentified bodies or suspected human remains is a frequent and important task for forensic investigators. However, any identification method requires clues to the person’s identity to allow for comparisons with missing persons. If such clues are lacking, information about the year of birth, sex and geographic origin of the victim, is particularly helpful to aid in the identification casework and limit the search for possible matches. We present here results of stable isotope analysis of 13 C and 18 O, and bomb-pulse 14 C analyses that can help in the casework. The 14 C analysis of enamel provided information of the year of birth with an average absolute error of 1.8±1.3 years. We also found that analysis of enamel and root from the same tooth can be used to determine if the 14 C values match the rising or falling part of the bomb-curve. Enamel laydown times can be used to estimate the date of birth of individuals, but here we show that this detour is unnecessary when using a large set of crude 14 C data of tooth enamel as a reference. The levels of 13 C in tooth enamel were higher in North America than in teeth from Europe and Asia, and Mexican teeth showed even higher levels than those from USA. DNA analysis was performed on 28 teeth, and provided individual-specific profiles in most cases and sex determination in all cases. In conclusion, these analyses can dramatically limit the number of possible matches and hence facilitate person identification work.

59 BASIC BIOLOGICAL SCIENCES↗

Nominations for the 2017 NNSA Pollution Prevention Awards

In the field of nuclear forensics, one of the biggest challenges is to dissolve postdetonation debris for analysis. Debris generated after a nuclear detonation is a glassy material that is difficult to dissolve with chemicals. Traditionally, concentrated nitric acid, hydrofluoric acid, or sulfuric acid are employed during the dissolution. These acids, due to their corrosive nature, are not suitable for in-field/on-site sample preparations. Uranium oxides are commonly present in nuclear fuel processing plants and nuclear research facilities. In uranium oxides, the level of uranium isotope enrichment is a sensitive indicator for nuclear nonproliferation and is monitored closely by the International Atomic Energy Agency (IAEA) to ensure there is no misuse of nuclear material or technology for nuclear weapons. During an IAEA on-site inspection at a facility, environmental surface swipe samples are collected and transported to the IAEA headquarters or network of analytical laboratories for further processing. Uranium oxide particles collected on the swipe medium are typically dissolved with inorganic acids and are then analyzed for uranium isotopic compositions. To improve the responsiveness of on-site inspections, in-field detection techniques have been recently explored. However, in-field analysis is bottlenecked by time-consuming and hazardous dissolution procedures, as corrosive inorganic acids must be used. Corrosive chemicals are difficult to use in the field due to personnel safety considerations, and the transportation of such chemicals is highly regulated. It was therefore necessary to develop fast uranium oxide dissolution methods using less hazardous chemicals in support of the rapid infield detection of anomalies in declared nuclear processes.

54 ENVIRONMENTAL SCIENCES↗

Strontium isoscape of sub-Saharan Africa allows tracing origins of victims of the transatlantic slave trade

Abstract Strontium isotope ( 87 Sr/ 86 Sr) analysis with reference to strontium isotope landscapes (Sr isoscapes) allows reconstructing mobility and migration in archaeology, ecology, and forensics. However, despite the vast potential of research involving 87 Sr/ 86 Sr analysis particularly in Africa, Sr isoscapes remain unavailable for the largest parts of the continent. Here, we measure the 87 Sr/ 86 Sr ratios in 778 environmental samples from 24 African countries and combine this data with published data to model a bioavailable Sr isoscape for sub-Saharan Africa using random forest regression. We demonstrate the efficacy of this Sr isoscape, in combination with other lines of evidence, to trace the African roots of individuals from historic slavery contexts, particularly those with highly radiogenic 87 Sr/ 86 Sr ratios uncommon in the African Diaspora. Our study provides an extensive African 87 Sr/ 86 Sr dataset which includes scientifically marginalized regions of Africa, with significant implications for the archaeology of the transatlantic slave trade, wildlife ecology, conservation, and forensics.

Science & Technology - Other Topics↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Volatiles from the necrophagous fly Cochliomyia macellaria (Diptera: Calliphoridae) as indicators of Salmonella exposure

Blow flies (Diptera: Calliphoridae) are crucial in forensic investigations due to their association with both living and dead humans and other animals. Additionally, their interactions with various resources and potential as vectors of pathogens of humans and other animals, thus, make them potential tools for biosurveillance. This study investigated the potential of monitoring volatile organic compounds (VOCs) emitted by blow flies exposed to Salmonella as a method for pathogen surveillance. Adult blow flies ( Cochliomyia macellaria ) were exposed, or not, to Salmonella enterica . Following exposure, VOCs released by the blow flies were collected and analyzed using gas chromatography-mass spectrometry (GC-MS). Results indicate a treatment by time interaction (P < 0.01). Indicator species analysis identified a single compound significantly associated with S. enterica exposure (P = 0.02), Nonane, 2,2,4,4,6,8,8-heptamethyl, potentially indicating an immune system response. Given a compound indicating exposure was detected, future research should determine if more replicates could detect more differences after Salmonella ingestion. This research highlights the potential of blow flies as biosurveillance tools and the potential value of volatiles for assessing their exposure to pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗