Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Nanowire-Based Materials as Coke-Resistant Catalyst Supports for Dry Methane Reforming

In this paper, nanowire-supported catalysts loaded with nickel are shown to be coke resistant compared to nanoparticle-supported catalysts. Specifically, Ni-loaded titania-based nanowire catalysts were tested with the dry methane reforming process in a laboratory-scale continuous packed-bed atmospheric reactor. The CO 2 conversion rate stayed above 90% for over 30 h on stream under coke-promoting conditions, such as high flow rates, low temperatures, and a high ratio of CH 4 to CO 2 . The coke (C x H y , x>>y) on the spent catalyst surface for both nanowire- and nanoparticle-supported catalysts was characterized by TGA, temperature-programmed reduction (TPR), and electron microscopy (SEM/TEM/EDS), and it was revealed that the types of carbon species present and their distribution over the morphology-enhanced materials played a major role in the deactivation. The CO 2 conversion activity of Ni supported on titania nanoparticles was reduced from ~80% to less than 72% in 30 h due to the formation of a graphitic coke formation. On the other hand, Ni particles supported on nanowires exhibited cube-octahedral morphologies, with a high density of non- (111) surface sites responsible for the increased activity and reduced graphitic coke deposition, giving a sustained and stable catalytic activity during a long time-on-stream experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen, Methane, Brine Flow Behavior, and Saturation in Sandstone Cores During H 2 and CH 4 Injection and Displacement

Large-scale underground hydrogen storage (UHS) is a critical component in the emerging hydrogen economy. Knowledge of multiphase flow behavior involving hydrogen in storage reservoir formations is crucial to characterizing hydrogen transport properties and essential for the deliverability and storage operations of UHS. There are still many gaps in fully understanding hydrogen–methane–brine multiphase phase flow that require further investigation. In this work, H 2 and CH 4 were injected through brine-saturated sandstone cores using a tri-axial core holder system fitted with flow rate meters and pressure transducers, while the effluent gas concentrations were analyzed using an online micro gas chromatograph. Brine displacement, permeability, and gas breakthrough curves were measured. We studied the flow behavior of hydrogen and methane in sandstone cores through testing brine displacement by gas injection and comparing the hydrogen displacement of methane with the methane displacement of hydrogen. We also tested the differences between horizontal and vertical flow in brine displacement. The results showed that brine displacement was more efficient in a core with higher permeability and porosity, resulting in a higher initial gas saturation. A higher gas injection rate brought about faster gas breakthrough measured by pore volume and sharper concentration curves. Hydrogen did not exhibit abnormal flow in the sandstone when the flow was horizontal and downward vertical. Gas overriding was observed in brine displacements when the flow was horizontal, with hydrogen showing this behavior more profoundly compared to methane. Downward vertical gas injection induced higher efficiency brine displacement compared to horizontal displacement and resulted in a higher initial gas saturation in the sandstone cores. These findings address critical knowledge gaps regarding gas flow patterns and displacement behaviors during hydrogen injection and recovery phases in UHS facilities using methane as the cushion gas. The insights from this research offer valuable guidance for optimizing UHS systems, ensuring operational efficiency, and advancing sustainable energy solutions in alignment with decarbonization goals.

08 HYDROGEN↗

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗

The influence of temperature history and flow mixing on the vapor-phase speciation of uranium oxide nanoparticles

The transport of radioactive material following a nuclear event depends heavily on fallout characteristics (e.g., composition, shape, and size), which in turn are controlled by the conditions under which the fallout forms. To this end, we use a novel plasma flow reactor (PFR) to explore how conditions including temperature history and gas mixing influence the chemical speciation and physical characteristics of uranium oxide nanoparticles. The PFR consists of a glass tube attached to an inductively coupled plasma (ICP) torch via an adaptor piece (ring flow injector) located downstream of the plasma-generating RF coil. We increase the gas flow rates from normal ICP operating conditions to higher values both upstream at the RF coil and downstream at the ring flow injector to create four distinct temperature profiles and two distinct gas flow mixing conditions (normal and higher Ar atomic ratios). Ex situ transmission electron microscopy (TEM) analysis is used to determine the crystal structure, morphology, and size distribution of the synthesized particles as a function of temperature and mixing. The particles display a striking dependence on these conditions in terms of the resulting speciation of uranium oxide: lower temperature (higher upstream) and slower cooling (normal downstream with normal Ar atomic ratio mixing) favor the formation of α-UO 3 particles, while faster cooling (higher downstream with higher Ar atomic ratio mixing) and higher temperature (normal upstream) favor the formation of UO 2 particles. The extent of gas mixing dictates particle aggregation: better mixing encourages the particles to aggregate more extensively. Here these results demonstrate the sensitivity of uranium to initial local conditions and can be used to improve our understanding of the kinetics that drive uranium speciation and ultimately inform fallout transport models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Ultrasonic oscillatory two-phase flow in microchannels

Experimental and numerical investigations are performed to provide an assessment of the transport behavior of an ultrasonic oscillatory two-phase flow in a microchannel. The work is inspired by the flow observed in an innovative ultrasonic fabric drying device using a piezoelectric bimorph transducer with microchannels, where a water-air two-phase flow is transported by harmonically oscillating microchannels. The flow exhibits highly unsteady behavior as the water and air interact with each other during the vibration cycles, making it significantly different from the well-studied steady flow in microchannels. Here, the computational fluid dynamics (CFD) modeling is realized by combing the turbulence Reynolds-averaged Navier-Stokes (RANS) k – ω model with the phase-field method to resolve the dynamics of the two-phase flow. The numerical results are qualitatively validated by the experiment. Through parametric studies, we specifically examined the effects of vibration conditions (i.e., frequency and amplitude), microchannel taper angle, and wall surface contact angle (i.e., wettability) on the flow rate through the microchannel. The results will advance the potential applications where oscillatory or general unsteady microchannel two-phase flows may be present.

42 ENGINEERING↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hythane production from brewery wastewater‐generated biogas using a membrane electrochemical cell

Converting organic wastes into hythane, a blend of hydrogen (5% to 25%) and methane (75% to 95%), will not only reduce waste discharge but also maximize energy recovery. Herein, a membrane electrochemical cell was investigated to produce hythane from biogas generated in anaerobic digestion of brewery wastewater (BW). The key parameters including current densities, electrolyte concentrations, and biogas flow rates were examined in batch tests. Under an optimal condition (210 mA, 100 mM electrolyte, 1 mL min −1 of biogas flow), the system achieved the production of hythane containing 70.6% ± 1.1% CH 4 , 27.3% ± 0.5% H 2 , and 2.1% ± 1.6% CO 2 (corresponding to 91.1% ± 6.4% CO 2 removal). Meanwhile, the H 2 S concentration was decreased from 513 to 2 ppm, 99.9% ± 0.2% removal. Energy efficiency of this system was estimated 61.8% ± 10.7%, and energy output increased by 54.4% ± 10.6% with biogas upgrading to hythane. Furthermore, these results encourage further exploration of electrochemical approach for simultaneous biogas upgrading and hythane production.

Rao, Yue [Washington University in St. Louis, MO (↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Analysis of ducted fuel injection at high-pressure transcritical conditions using large-eddy simulations

Ducted fuel injection (DFI) is a proposed fuel injection concept for achieving substantial reductions in emissions. In this concept, the fuel is injected through a coannular duct, resulting in increased fuel-air mixing and minimized formation of soot and other unwanted combustion products. Apart from comprehensive experimental investigations on DFI, so far computational studies have been limited to single-point Reynolds-averaged Navier Stokes simulations. Therefore, the objective of this work is to complement these studies by performing large-eddy simulations using a diffuse-interface method to examine the physical mechanisms and combustion processes of DFI, specifically focusing on the mixing process and the effect of fuel-ducting on combustion and pollutant emissions. To this end, finite-rate chemistry simulations are performed of the DFI configuration corresponding to the Engine Combustion Network Spray A injector at transcritical conditions (n-dodecane fuel, 60 bar pressure and 1000 K temperature chamber conditions). A two-equation soot model is employed for the qualitative analysis of soot emissions. Direct comparisons of averaged and instantaneous flow field results with the Spray A configuration are performed to assess the effect of DFI on the first- and second-stage ignition and soot formation. Compared to the free-spray condition, the results show that the DFI case exhibits a combination of (i) increased mass flow rate and entrained air, (ii) larger pressure drop magnitude and flow velocity, and (iii) a closer-to-stoichiometric mixture composition (both globally and locally), each of which is conjectured to contribute toward reduced soot production.

33 ADVANCED PROPULSION SYSTEMS↗

CISCC Countermeasures for Spent Fuel Canisters in Concrete Casks

Aging management of spent fuel is an important issue worldwide. Chloride-induced stress corrosion cracking (CISCC) of welded canisters is particularly important for concrete casks, where it occurs in response to a combination of environmental, material, and residual stress factors. In this paper, we introduce a countermeasure to prevent the occurrence of CISCC by adjusting the flow rate of the cooling air into the concrete cask so that the canister surface temperature does not decrease below 100°C, which is a conservative deliquesce temperature threshold for CISCC occurrence. The flow adjustment device was installed in a cask model, and two tests were conducted under the heat rate conditions corresponding to those of an actual canister. In the first test, the device was operated under a condition where the canister surface temperature was below 100°C to verify whether it could increase the canister surface temperature to above 100°C. In the second test, the heat rate was decreased from a state where the canister surface temperature was above 100°C, to verify whether the device could maintain the canister surface temperature above 100°C. Good results were obtained in both cases. However, in the case of a low decay heat rate of spent fuel after extended dry storage, the temperature of the canister surface may decrease below 100°C even if no air supply is provided. Therefore, in this case, it may be necessary to take measures such as blocking air outlets.

Takeda, Hirofumi↗

Environmental life cycle impacts of small wastewater treatment plants: Design recommendations for impact mitigation

The objective of this study was to quantify potential mitigation of environmental impacts from the operation and construction of wastewater treatment plants (WWTP) from implementing specific design recommendations. The study investigated small WWTPs, many of which are serving slow growing or declining populations. Life Cycle Assessment methodology was used to evaluate and compare the inventory and environmental impacts of nine small WWTP case studies. Detailed inventory data was collected from the facilities’ engineering design plans and utility bills. One recommended practice was to avoid significant overdesign by planning for no lower than a 75% capacity utilization by the facilities’ end-of-life. A theoretical correction to a 75% capacity utilization was estimated to mitigate 0.4% of lifetime electricity usage and 1% of secondary process concrete for every 1% reduction in design average flow rate. Relatedly, a 0.4% mitigation in the Carcinogenic and Global Warming impacts could be achieved for every 1% reduction in design average flow toward a 75% capacity utilization. Other suggested practices were focused on conveyance, namely, to minimize non-process facility area and to use polyvinyl chloride pipe instead of ductile iron pipe where possible. Furthermore, the latter practice was estimated to mitigate between 1.1 and 4.8% of the Carcinogenic impact in the nine case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling↗