Understanding the Spin Transport in H{sub 2}O-Adsorbed CNT-Based Magnetic Tunnel Junction

We calculate the important parameters based on spin-dependent quantum transport properties in water (H{sub 2}O)-adsorbed CNT-based magnetic tunnel junction (MTJ) with half-metallic magnet (HMM) or half-metallic ferromagnet (HMF) electrodes. Adsorption of H{sub 2}O on CNT reduces the band gap. H{sub 2}O-adsorbed CNT becomes less suitable as tunnel barrier. It is found that H{sub 2}O adsorption introduces transmission states in anti-parallel configuration which are seen as spikes in its transmission spectrum. This reduces tunnel magneto-resistance (TMR) of the MTJ structure. The value of TMR obtained in this structure is ∼80% at 0 V bias point, and it attains a value of 96.7% at 0.3 V bias. TMR of this structure is less than that structure having a bare CNT. Spin filtration or spin polarization of ∼100% is attained at all bias voltages in parallel configuration (PC) whereas in the case of anti-parallel configuration (APC), spin filtration is 84.2% at 0.9 V bias which is caused by introduction of spikes in spin-down transmission spectrum of APC. This suggests that water adsorption badly affects the performance of the MTJ devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Kidney function and blood pressure in preschool-aged children exposed to cadmium and arsenic - potential alleviation by selenium

Background: Early-life exposure to toxic compounds may cause long-lasting health effects, but few studies have investigated effects of childhood exposure to nephrotoxic metals on kidney and cardiovascular function. Objectives: To assess effects of exposure to arsenic and cadmium on kidney function and blood pressure in pre-school-aged children, and potential protection by selenium. Methods: This cross-sectional study was part of the 4.5 years of age (range: 4.4–5.4 years) follow-up of the children from a supplementation trial in pregnancy (MINIMat) in rural Bangladesh, and nested studies on early-life metal exposures. Exposure to arsenic, cadmium and selenium from food and drinking water was assessed by concentrations in children's urine, measured by ICP-MS. Kidney function was assessed by the estimated glomerular filtration rate (eGFR, n=1106), calculated from serum cystatin C, and by kidney volume, measured by ultrasound (n=375). Systolic and diastolic blood pressure was measured (n=1356) after five minutes rest. Results: Multivariable-adjusted regression analyzes showed that exposure to cadmium, but not arsenic, was inversely associated with eGFR, particularly in girls. A 0.5 µg/L increase in urinary cadmium among the girls (above spline knot at 0.12) was associated with a decrease in eGFR of 2.6 ml/min/1.73 m{sup 2}, corresponding to 0.2SD (p=0.022). A slightly weaker inverse association with cadmium was also indicated for kidney volume, but no significant associations were found with blood pressure. Stratifying on children's urinary selenium (below or above median of 12.6 µg/L) showed a three times stronger inverse association of U-Cd with eGFR (all children) in the lower selenium stratum (B=−2.8; 95% CI: −5.5, −0.20; p=0.035), compared to those with higher selenium (B=−0.79; 95% CI: −3.0, 1.4; p=0.49). Conclusions: Childhood cadmium exposure seems to adversely affect kidney function, but not blood pressure, in this population of young children in rural Bangladesh. Better selenium status appears to be protective. However, it is important to follow up these children to assess potential long-term consequences of these findings. - Highlights: • Bangladesh has high levels of arsenic and cadmium in drinking water and food • We assessed toxic exposure, kidney and cardiovascular function in Bangladeshi children • Cadmium appeared to decrease estimated glomerular filtration rate in girls • These effects were somewhat alleviated by selenium.

54 ENVIRONMENTAL SCIENCES↗

Automated SEM analysis of particles in Hanford tank waste

Multiple bench-scale filtration campaigns of Hanford tank waste supernatant on a backpulseable dead-end filtration skid have provided greater insight into the solids that cause fouling and reduce filter performance. The solids collected during each campaign were concentrated from the backpulse solutions and examined using automated particle analysis (APA) methods with scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDS), to categorize particle types and their morphological characteristics. Finally, we show that with APA, thousands of particles can be analyzed that can provide accurate insight into the phases that may be impacting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The effects of filamentary Ni, graphene and lithium amide (LiNH2) additives on the dehydrogenation behavior of mechano-chemically synthesized crystalline manganese borohydride (Mn(BH4)2) and its solvent filtration/extraction

Highlights: • Effect of graphene, filamentary Ni and LiNH{sub 2} on the synthesis of Mn(BH{sub 4}){sub 2} investigated. • Mechanical dehydrogenation observed for filamentary Ni and LiNH{sub 2} but not for graphene. • All additives suppressed the release of B{sub 2}H{sub 6} during thermal decomposition of Mn(BH{sub 4}){sub 2} with filamentary Ni being the strongest suppressor. • The LiNH{sub 2} additive reduced the apparent activation energy for dehydrogenation to 44.9 ± 4.3 kJ/mol. • After solvent filtration and extraction of the (Mn(BH{sub 4}){sub 2}/LiCl) sample, a dimetallic hydride [{Li(Et_2O)_2}Mn{sub 2}(BH{sub 4}){sub 5}] was found. - Abstract: Dehydrogenation properties of mechano-chemically synthesized crystalline Mn(BH{sub 4}){sub 2} hydride without and with ultrafine filamentary carbonyl nickel (Ni), graphene and LiNH{sub 2} were investigated. It is reported for the first time that all additives suppressed the release of B{sub 2}H{sub 6} with the filamentary Ni additive being the most effective suppressor of B{sub 2}H{sub 6}. In DSC, the decomposition peak of Mn(BH{sub 4}){sub 2} was endothermic. The estimated apparent activation energy for isothermal dehydrogenation was dramatically reduced to 44.9 ± 4.3 kJ/mol for the 5 wt.% LiNH{sub 2} additive from about 76–81 kJ/mol range for the additive-free sample and 5 wt.% filamentary Ni and graphene additives. The most striking finding, that has never been reported in the literature, is that the process of solvent filtration and extraction of the mechano-chemically synthesized (Mn(BH{sub 4}){sub 2}/LiCl) sample, resulted in the crystallization of a dimetallic borohydride solvate [{Li(Et_2O)_2}Mn{sub 2}(BH{sub 4}){sub 5}] instead of crystalline Mn(BH{sub 4}){sub 2}. Its dehydrogenation behavior was investigated isothermally and by TGA/DSC.

36 MATERIALS SCIENCE↗

Scalable aqueous-phase fabrication of reduced graphene oxide nanofiltration membranes by an integrated roll-to-roll (R2R) process

Economic fractionation of multicomponent biomass-derived streams is a key challenge in biobased fuels and chemicals production. Kraft black liquor (BL) is generated at ~1 billion tons/yr globally from biomass pulping and contains ~15wt% total solids including lignin, hemicellulose fragments, and inorganics. Membrane-based BL concentration is attractive but challenged by low solute rejections and poor stability in BL, which combines alkaline pH (~13), high dissolved solids content (15+ wt%) and high temperature (70–85°C). Here we discuss the scaled fabrication and characterization of reduced graphene oxide (rGO) nanofiltration membranes by slot die coating on a roll-to-roll (R2R) with integrated vacuum filtration. Here, we obtain high-quality 90×30 cm rGO membranes (referred to as “R2R-rGO membranes” in this work) with ~100 nm average thickness supported on porous poly(ethersulfone) (PES) sheets, and an effective area of 2700cm 2 . We present characterizations of their microstructure and uniformity as mapped over large areas by scanning electron microscopy (SEM), ellipsometry, adhesion test and X-ray photoelectron spectroscopy (XPS). The constructed ellipsometry model for the rGO membrane/PES substrate composite was successfully applied to 48 different locations of the R2R-rGO membranes. The R2R-rGO membranes showed >98% lignin rejection with a steady state flux of ~12 LMH at 50bar in a 15.7wt% total solids (TS) kraft BL stream at 72°C and 2–3 gal/min crossflow rates. Slot die coating on a R2R platform with integrated vacuum filtration can enable rapid fabrication of high-quality GO membranes at scale without organic solvents or volatile organic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

Seeding Advanced Treated Wastewater for Purposes of Direct Potable Reuse

Direct potable reuse (DPR) is a promising solution to address water scarcity. However, a better understanding of how introducing advanced treated water (ATW) affects microbial communities present in distribution systems is needed. Here, in this study, we measured changes to the microbial water quality in simulated distribution systems that were conditioned using treated, unimpaired surface water (SW) and then transitioned to ATW. In addition, we investigated whether adding a biological filtration step would seed the microbial community of the ATW and whether the influence would persist in the simulated distribution systems. We found that the bulk water in the ATW-fed distribution systems had lower cell counts and ATP concentrations and a distinct microbial community (based on 16S amplicon sequencing) compared to the SW-fed or the seeded ATW-fed systems. However, biofilm community composition and biomass remained consistent regardless of the feedwater. Increased microbial biomass and diversity were present in the seeded ATW, with several amplicon sequence variants identified as being introduced by the biological filter. Our results suggest that directly introducing ATW to distribution systems could disturb the existing microbial community. Preparing ATW for distribution via biological filtration may deliver more predictable and stable microbial water quality than introducing unseeded ATW.

16S↗

In Situ Investigation on the Nanoscale Capture and Evolution of Aerosols on Nanofibers

Aerosol-induced haze problem has become a serious environmental concern. Filtration is widely applied to remove aerosols from gas streams. Despite classical filtration theories, the nanoscale capture and evolution of aerosols is not yet clearly understood. In this paper, we report an in situ investigation on the nanoscale capture and evolution of aerosols on polyimide nanofibers. We discovered different capture and evolution behaviors among three types of aerosols: wetting liquid droplets, nonwetting liquid droplets, and solid particles. The wetting droplets had small contact angles and could move, coalesce, and form axisymmetric conformations on polyimide nanofibers. In contrast, the nonwetting droplets had a large contact angle on polyimide nanofibers and formed nonaxisymmetric conformations. Different from the liquid droplets, the solid particles could not move along the nanofibers and formed dendritic structures. Finally, this study provides an important insight for obtaining a deep understanding of the nanoscale capture and evolution of aerosols and benefits future design and development of advanced filters.

36 MATERIALS SCIENCE↗

Decontamination of SARS-CoV-2 and Other RNA Viruses from N95 Level Meltblown Polypropylene Fabric Using Heat under Different Humidities

In March of 2020, the World Health Organization declared a pandemic of coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The pandemic led to a shortage of N95-grade filtering facepiece respirators (FFRs), especially surgical-grade N95 FFRs for protection of healthcare professionals against airborne transmission of SARS-CoV-2. We and others have previously reported promising decontamination methods that may be applied to the recycling and reuse of FFRs. In this study we tested disinfection of three viruses, including SARS-CoV-2, dried on a piece of meltblown fabric, the principal component responsible for filtering of fine particles in N95-level FFRs, under a range of temperatures (60–95 °C) at ambient or 100% relative humidity (RH) in conjunction with filtration efficiency testing. We found that heat treatments of 75 °C for 30 min or 85 °C for 20 min at 100% RH resulted in efficient decontamination from the fabric of SARS-CoV-2, human coronavirus NL63 (HCoV-NL63), and another enveloped RNA virus, chikungunya virus vaccine strain 181/25 (CHIKV-181/25), without lowering the meltblown fabric’s filtration efficiency.

60 APPLIED LIFE SCIENCES↗

Study of de-watering from the gelatinous precipitate formed during co-precipitation of Nd-YAG powder

Neodymium doped Yttrium Aluminium Garnet (Nd:YAG) ceramics have been synthesised using coprecipitation technique and high temperature vacuum sintering. Gelatinous like precipitates were obtained when precursors of Nd, Al and Yb-nitrate solutions are co-precipitated using ammonia co-precipitant. De-watering from the gelatinous like precipitates is a big challenge and it possesses difficulty in filtration. Evaporation of water by heating resulted in strong agglomerated powder. Different agents were used to ease the filtration process, which is correlated with the phase in the calcined powder.

36 MATERIALS SCIENCE↗

Hotspot electron temperature from x-ray continuum measurements on the NIF

We report on measurements of the electron temperature in the hotspot of inertially confined, layered, spherical implosions on the National Ignition Facility using a differential filtering diagnostic. Measurements of the DT and DD ion temperatures using neutron time-of-flight detectors are complicated by the contribution of hot spot motion to the peak width, which produce an apparent temperature higher than the thermal temperature. The electron temperature is not sensitive to this non-thermal velocity and is thus a valuable input to interpreting the stagnated hot spot conditions. Here we show that the current differential filtering diagnostic provides insufficient temperature resolution for the hot spot temperatures of interest. We then propose a new differential filter configuration utilizing larger pinhole size to increase spectral fluence, as well as thicker filtration. This new configuration will improve measurement uncertainty by more than a factor of three, allowing for a more accurate hotspot temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detectors of Circularly Polarized Radiation Based on Semiconductor Heterostructures with a CoPt Schottky Barrier

Abstract—In this paper, we showed the possibility of practical realization of circularly polarized radiation detectors based on a planar photoresistor using the effect of magnetocircular dichroism in the CoPt layer, as well as based on structures using the spin filtration by the CoPt layer of photogenerated spin-polarized charge carriers. The spin filtration process is established to allow increasing the detection efficiency of up to 1.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emerging technologies and approaches to minimize discharges into Lake Michigan, phase 2 module 4 report.

The Great Lakes Initiative (GLI) established the new water quality-based discharge criteria for mercury (Hg), thereby increasing the need for many municipal and industrial wastewater treatment plants in the region to lower the mercury in their effluents. Information on deployable technologies to satisfy these requirements for industrial and municipal dischargers in the Great lakes region is scarce. Therefore, BP funded Purdue University Calumet and Argonne to identify deployable Hg removal technologies to meet the GLI discharge criterion at its Whiting Refinery in Indiana. The joint PUC/Argonne project was divided into 2 phases. Results from Phase I and Phase II Modules 1-3 have been previously reported. This report summarizes the work done in Phase 3 Module 4, which consisted of the pilot scale testing of Hg removal technologies previously selected in Module 3. The pilot testing was an Argonne/PUC jointly directed project that was hosted at and funded by the BP refinery in Whiting, IN. As two organizations were involved in data analysis and interpretation, this report combines two independent sets of evaluations of the testing that was done, prepared respectively by Argonne and Purdue. Each organization retains sole responsibility for its respective analysis conclusions and recommendations. Based on Module 3 bench testing with pre-Effluent To Lake (pre-ETL) and clarifier effluent (CE) samples from the Whiting refinery, three different technologies were chosen for pilot testing: (1) Ultrafiltration (using GE ZeeWeed(reg sign) Technology, 0.04 {mu}m pore size and made up of PVDF) for particulate mercury removal; (2) Adsorption using Mersorb(reg sign) LW, a sulfur-impregnated activated carbon, for dissolved mercury removal if present and (3) The Blue PRO(reg sign) reactive filtration process for both particulate and dissolved (if present) mercury removal. The ultrafiltration and the Blue PRO(reg sign) reactive filtration pilot studies were done simultaneously at the BP Whiting refinery using a slipstream of wastewater taken just prior to the Effluent to lake (pre-ETL) outfall. It was the intention of this pilot testing to demonstrate proof of concept, i.e. can the discharge limits obtained at bench scale be consistently met at the pilot scale. Although Mersorb(reg sign) LW was selected for dissolved mercury removal testing, this technology was not pilot tested because of a lack of dissolved mercury in the test wastewater during the pilot study. The overall objective of this pilot testing was to demonstrate the effectiveness of the tested technologies with continuous and varying feed conditions to meet the GLI criterion (1.3 ppt). Optimization for full-scale design was outside of the scope of this work. In addition to demonstrating whether the Hg criterion can be met, information on residue generation rate, frequency of backwashing and other maintenance issues were collected to better understand the implications for a full-scale system.