Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FARADAY EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Evaluation of ion collection area in Faraday probes

A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced magneto-optical effects in composite coaxial nanowires embedded with Ag nanoparticles

Nanostructures decorated with noble metal nanoparticles (NPs) exhibit potential for use in highly sensitive optoelectronic devices through the localized surface plasmon resonance (LSPR) effect. In this study, Faraday rotation was significantly enhanced through the structural optimization of ferromagnetic (FM)/semiconductor composite nanostructures. Experimental and theoretical results revealed that the position of noble metal NPs significantly influenced the coupling of the LSPR-enhanced electromagnetic field with FM materials. Furthermore, nanostructures embedded with noble metals demonstrated an improved capability to efficiently use the electromagnetic field compared to other structures. The Faraday rotation of ZnO/Ag(NPs)/Fe was enhanced 58 fold compared to that of the ZnO(film)/Fe. This work provides a basis for the design of nanoarchitectures for miniaturized high-performance magneto-optical devices

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

Diffractive Combiner of Single-Mode Pump Laser-Diode Beams

An optical beam combiner now under development would make it possible to use the outputs of multiple single-mode laser diodes to pump a neodymium: yttrium aluminum garnet (Nd:YAG) nonplanar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, an Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained below, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. Figure 1 schematically illustrates the principle of operation of a laser-diode-pumped Nd:YAG NPRO. The laser beam path is confined in a Nd:YAG crystal by means of total internal reflections on the three back facets and a partial-reflection coating on the front facet. The wavelength of the pump beam - 808 nm - is the wavelength most strongly absorbed by the Nd:YAG crystal. The crystal can lase at a wavelength of either 1,064 nm or 1,319 nm - which one depending on the optical coating on the front facet. A thermal lens effect induced by the pump beam enables stable lasing in the lowest-order transverse electromagnetic mode (the TEM00 mode). The frequency of this laser is very stable because of the mechanical stability of the laser crystal and the unidirectional nature of the lasing. The unidirectionality is a result of the combined effects of (1) a Faraday rotation induced by an externally applied magnetic field and (2) polarization associated with non-normal incidence and reflection on the front facet.

Liu, Duncan↗

Optical configuration optimization and calibration for the POINT system on EAST

Calibration of the polarimeter system is one of the key elements to determine the overall measurement accuracy. The anisotropic reflection and transmission properties of the mesh beam splitters can easily distort the polarization state of the circularly polarized beams. Using a rotating crystal quartz λ/2-waveplate to replace the plasma can effectively allow us to obtain the ratio of the measured Faraday rotation angle to the known rotation angle of the waveplate. This ratio is used to estimate the calibration factor for each chord to be accurately determined and help to minimize distortions introduced by the wire-mesh beam splitters. With the novel configuration optimization, the distortion of polarization state is effectively eliminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STUDYING THE INTERSTELLAR MAGNETIC FIELD FROM ANISOTROPIES IN VELOCITY CHANNELS

Turbulence in the interstellar medium is anisotropic due to the ubiquitous magnetic fields. This anisotropy depends on the strength of the magnetic field and leaves an imprint on observations of spectral line maps. We use a grid of ideal magnetohydrodynamic simulations of driven turbulence and produce synthetic position–position–velocity maps to study the turbulence anisotropy in velocity channels of various resolutions. We found that the average structure function of velocity channels is aligned with the projection of the magnetic field on the plane of the sky. We also found that the degree of such anisotropy increases with the magnitude of the magnetic field. For thick velocity channels (low velocity resolution), the anisotropy is dominated by density, and the degree of anisotropy in these maps allows one to distinguish sub-Alfvénic and super-Alfvénic turbulence regimes, but it also depends strongly on the sonic Mach number. For thin channels (high velocity resolution), we find that the anisotropy depends less on the sonic Mach number. An important limitation of this technique is that it only gives a lower limit on the magnetic field strength because the anisotropy is related only to the magnetic field component on the plane of the sky. It can, and should, be used in combination with other techniques to estimate the magnetic field, such as the Fermi-Chandrasekhar method, anisotropies in centroids, Faraday rotation measurements, or direct line-of-sight determinations of the field from Zeeman effect observations.

79 ASTRONOMY AND ASTROPHYSICS↗

SPARSE FARADAY ROTATION MEASURE SYNTHESIS

Faraday rotation measure synthesis is a method for analyzing multichannel polarized radio emissions, and it has emerged as an important tool in the study of Galactic and extragalactic magnetic fields. The method requires the recovery of the Faraday dispersion function from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we discuss a recovery method that assumes a sparse approximation of the Faraday dispersion function in an overcomplete dictionary of functions. We discuss the general case when both thin and thick components are included in the model, and we present the implementation of a greedy deconvolution algorithm. We illustrate the method with several numerical simulations that emphasize the effect of the covered range and sampling resolution in the Faraday depth space, and the effect of noise on the observed data.

79 ASTRONOMY AND ASTROPHYSICS↗

Faraday rotation measure synthesis of intermediate redshift quasars as a probe of intervening matter

There is evidence that magnetized material along the line of sight to distant quasars is detectable in the polarization properties of the background sources. The polarization properties appear to be correlated with the presence of intervening Mg ii absorption, which is thought to arise in outflowing material from star forming galaxies. In order to investigate this further, we have obtained high spectral resolution polarization measurements, with the Very Large Array and the Australia Telescope Compact Array, of a set of 49 unresolved quasars for which we have high quality optical spectra. These enable us to produce a Faraday Depth spectrum for each source, using Rotation Measure (RM) Synthesis. Our new independent radio data confirms that interveners are strongly associated with depolarization. We characterize the complexity of the Faraday Depth spectrum using a number of parameters and show how these are related, or not, to the depolarization and to the presence of Mg ii absorption along the line of sight. We argue that complexity and structure in the Faraday Depth distribution likely arise from both intervening material and intrinsically to the background source and attempt to separate these. We find that the strong radio depolarization effects associated with intervening material at redshifts out to z≈1 arise from inhomogeneous Faraday screens producing a dispersion in RM across individual sources of around 10 rad m{sup −2}. This is likely produced by disordered fields with strengths of at least 3 μG.

79 ASTRONOMY AND ASTROPHYSICS↗

Magneto-optical conductivity of anisotropic two-dimensional Dirac–Weyl materials

In the presence of an external magnetic field, the optical response of two-dimensional materials, whose charge carriers behave as massless Dirac fermions with arbitrary anisotropic Fermi velocity, is investigated. Using Kubo formalism, we obtain the magneto-optical conductivity tensor for these materials, which allows to address the magneto-optical response of anisotropic Dirac fermions from the well known magneto-optical conductivity of isotropic Dirac fermions. As an application, we analyse the combined effects of strain-induced anisotropy and magnetic field on the transmittance, as well as on the Faraday rotation, of linearly polarized light after passing strained graphene. The reported analytical expressions can be a useful tool to predict the absorption and the Faraday angle of strained graphene under magnetic field. Finally, our study is extended to anisotropic two-dimensional materials with Dirac fermions of arbitrary pseudospin. - Highlights: • The magneto-optical response of anisotropic massless Dirac fermions is investigated. • The conductivity tensor is obtained from the Kubo formula. • We study effects of strain and magnetic field on the light absorption of graphene. • The Faraday rotation in strained graphene is analytically determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact All-Fiber Optical Faraday Components Using 65-wt%-Terbium-Doped Fiber with a Record Verdet Constant of -32 rad/(Tm)

A compact all-fiber Faraday isolator and a Faraday mirror are demonstrated. At the core of each of these components is an all-fiber Faraday rotator made of a 4-cm-long, 65-wt%-terbium–doped silicate fiber. The effective Verdet constant of the terbium-doped fiber is measured to be –32 rad/(Tm), which is 27 × larger than that of silica fiber. This effective Verdet constant is the largest value measured to date in any fiber and is 83% of the Verdet constant of commercially available crystal used in bulk optics–based isolators. Combining the all-fiber Faraday rotator with fiber polarizers results in a fully fusion spliced all-fiber isolator whose isolation is measured to be 19 dB. Combining the all-fiber Faraday rotator with a fiber Bragg grating results in an all-fiber Faraday mirror that rotates the polarization state of the reflected light by 88 ± 4°.

Faraday effect↗

Measurements of high-current electron beams from X pinches and wire array Z pinches

Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonreciprocity in circular magnetoplasma-filled waveguides above the cyclotron frequency

The electromagnetic behavior of a circular perfect electric conductor waveguide with various magnetoplasma filling configurations has been investigated near the cyclotron resonance region at 77 K with longitudinal magnetic bias. Faraday rotation in the forward and reverse directions along with the waveguide geometry effect provided the nonreciprocal attenuation to design an isolator for frequencies up to the terahertz region. Based on the finite element method, two-dimensional eigenvalue as well as three-dimensional numerical simulations are provided to illustrate the phenomena. Unprecedented performance was attained for the coaxial configuration in terms of the bias-to-frequency ratio. Other configurations were found to have some nonreciprocity as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a collective scattering system for small scale turbulence study in Korea Superconducting Tokamak Advanced Research

The design characteristics of a multi-channel collective (or coherent) scattering system for small scale turbulence study in Korea Superconducting Tokamak Advanced Research (KSTAR), which is planned to be installed in 2017, are given in this paper. A few critical issues are discussed in depth such as the Faraday and Cotton-Mouton effects on the beam polarization, radial spatial resolution, probe beam frequency, polarization, and power. A proper and feasible optics with the 300 GHz probe beam, which was designed based on these issues, provides a simultaneous measurement of electron density fluctuations at four discrete poloidal wavenumbers up to 24 cm{sup −1}. The upper limit corresponds to the normalized wavenumber k{sub θ}ρ{sub e} of ∼0.15 in nominal KSTAR plasmas. To detect the scattered beam power and extract phase information, a quadrature detection system consisting of four-channel antenna/detector array and electronics will be employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data for "Propagation of EMIC Waves from Shabansky Orbits in the Dayside Magnetosphere"

Full-wave simulations of electromagnetic ion cyclotron waves in a non-dipole compressed magnetic field have been conducted using the Petra-M simulation code. The manuscript investigates the effect of misalignment of the Faraday screen and electron density in the scrape-off layer on the excitation and propagation of fast helicon and slow mode waves.

Magnetosphere: outer↗

Small-scale variations in the galactic magnetic field - The rotation measure structure function and birefringence in interstellar scintillations

The structure function of rotation measures of extragalactic sources and birefringence in interstellar scintillations are used to investigate variations in the interstellar magnetic field on length scales of about 0.01-100 pc and 10 to the 11th cm, respectively. Model structure functions are derived for the case of a power-law power spectrum of irregularities in the quantity (n(e)B), and an estimate for the structure function is computed for several regions of the sky using data on extragalactic sources. The results indicate an outer angular scale for rotation measure (RM) variations of not less than about 5 deg (a linear scale of about 9-90 pc at a distance of 0.1-1 kpc). There is also evidence for RM variations on angular scales as small as 1 arcmin, but it cannot be determined whether these are intrinsic to the source or caused by the interstellar medium. The effect of a random, Faraday-active medium on the diffraction of radio waves is derived, and an upper limit to the variations in n(e)B on a length scale of 10 to the 11th cm is obtained from available observations.

Simonetti, J. H.↗

Joint vector magnetograph observations at BBSO, Huairou Station and Mees Solar Observatory

Joint vector magnetograph observations were carried out at Big Bear Solar Observatory (BBSO), Huairou Solar Observing Station (Huairou), and Mees Solar Observatory (MSO) in late September 1989. Comparisons of vector magnetograms obtained at the three stations show a high degree of consistency in the morphology of both longitudinal and transverse fields. Quantitative comparisons show the presence of noise, cross-talk between longitudinal field and transverse field, Faraday rotation and signal saturation effects in the magnetograms. We have tried to establish how the scatter in measurements from different instruments is apportioned between these sources of error.

Wang, Haimin↗