Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

Ertl, A. C.↗

Experiment M-3: In-Flight Exerciser

The response of the cardiovascular system to a quantified workload is an index of the general physical condition of an individual. Utilizing mild exercise as a provocative stimulus, no significant decrement in the physical condition of either of the two astronauts could be detected during the Gemini V mission. The rate of return of the pulse rate to pre-exercise levels, following in-flight exercise periods, was essentially the same as that observed during preflight baseline studies.

Dietlein, Lawrence F.↗

Ground Reaction Force and Mechanical Differences Between the Interim Resistive Exercise Device (iRED) and Smith Machine While Performing a Squat

Musculoskeletal unloading in microgravity has been shown to induce losses in bone mineral density, muscle cross-sectional area, and muscle strength. Currently, an Interim Resistive Exercise Device (iRED) is being flown on board the ISS to help counteract these losses. Free weight training has shown successful positive musculoskeletal adaptations. In biomechanical research, ground reaction forces (GRF) trajectories are used to define differences between exercise devices. The purpose of this evaluation is to quantify the differences in GRF between the iRED and free weight exercise performed on a Smith machine during a squat. Due to the differences in resistance properties, inertial loading and load application to the body between the two devices, we hypothesize that subjects using iRED will produce GRF that are significantly different from the Smith machine. There will be differences in bar/harness range of motion and the time when peak GRF occurred in the ROMbar. Three male subjects performed three sets of ten squats on the iRED and on the Smith Machine on two separate days at a 2-second cadence. Statistically significant differences were found between the two devices in all measured GRF variables. Average Fz and Fx during the Smith machine squat were significantly higher than iRED. Average Fy (16.82 plus or minus.23; p less than .043) was significantly lower during the Smith machine squat. The mean descent/ascent ratio of the magnitude of the resultant force vector of all three axes for the Smith machine and iRED was 0.95 and 0.72, respectively. Also, the point at which maximum Fz occurred in the range of motion (Dzpeak) was at different locations with the two devices.

Amonette, William E.↗

The relationship between dietary intake, exercise, energy balance and the space craft environment

Space flight is associated with the loss of skeletal muscle, principally from muscles with anti-gravity functions. Examination of data across different missions can permit a distinction to be made between true microgravity responses and what are mission-specific responses. Protein metabolism has been investigated on six missions, four short-term [Shuttle missions Space Life Sciences 1 (1991, SLSI), Space Life Sciences 2 (1993, SLS2), Deutsche-2 (1993, D2) and the Life and Microgravity Sciences (1996, LMS)] and two long-term missions (Skylab 1993 and NASA/MIR, 1996-1998). Measurements made include dietary intake (six missions), nitrogen balance (four missions), whole-body protein kinetics with [15N]glycine as the tracer (four missions) and cortisol excretion (three missions). Also available for comparison are bed rest studies with and without exercise. The purpose of this paper is to see what can be learnt about the muscle loss problem by comparing metabolic results across the six missions for which data are available and against bed rest. The analysis suggests that there is a linkage between the inability to maintain energy balance and exercise, and the connection is the decreased efficiency of removal of the metabolic by-products of exercise (heat, CO2) during space flight.

long duration↗

Time course of vasodilatory responses in skeletal muscle arterioles: role in hyperemia at onset of exercise

At the onset of dynamic exercise, muscle blood flow increases within 1-2 s. It has been postulated that local vasodilatory agents produced by the vascular endothelium or the muscle itself contribute to this response. We hypothesized that only vasodilators that act directly on the vascular smooth muscle could produce vasodilation of skeletal muscle arterioles in <2 s. To test this hypothesis, we determined the time course of the vasodilatory response of isolated skeletal muscle arterioles to direct application of potassium chloride, adenosine, acetylcholine, and sodium nitroprusside. Soleus and gastrocnemius muscles were dissected from the hindlimbs of male Sprague-Dawley rats. First-order arterioles (100-200 microm) were isolated, cannulated on micropipettes, and pressurized to 60 cmH(2)O in an organ bath. Vasodilatory agents were added directly to the bath, and diameter responses of the arterioles were recorded in real time on a videotape recorder. Frame-by-frame analysis of the diameter responses indicated that none of the vasodilator agents tested produced significant diameter increases in <4 s in either soleus or gastrocnemius muscle arterioles. These results indicate that, although these local vasodilators produce significant vasodilation of skeletal muscle resistance arterioles, these responses are not rapid enough (within 1-2 s) to contribute to the initiation of the exercise hyperemic response at the onset of dynamic exercise.

NASA Discipline Musculoskeletal↗

Comparison of sympathetic nerve responses to neck and forearm isometric exercise

PURPOSE: Although the autonomic and cardiovascular responses to arm and leg exercise have been studied, the sympathetic adjustments to exercise of the neck have not. The purpose of the present study was twofold: 1) to determine sympathetic and cardiovascular responses to isometric contractions of the neck extensors and 2) to compare sympathetic and cardiovascular responses to isometric exercise of the neck and forearm. METHODS: Muscle sympathetic nerve activity (MSNA), mean arterial pressure (MAP), and heart rate were measured in nine healthy subjects while performing isometric neck extension (INE) and isometric handgrip (IHG) in the prone position. After a 3-min baseline period, subjects performed three intensities of INE for 2.5 min each: 1) unloaded (supporting head alone), 2) 10% maximal voluntary contraction (MVC), and 3) 30% MVC, then subjects performed two intensities (10% and 30% MVC) of IHG for 2.5 min. RESULTS: Supporting the head by itself did not significantly change any of the variables. During [NE, MAP significantly increased by 10 +/- 2 and 31 +/- 4 mm Hg and MSNA increased by 67 +/- 46 and 168 +/- 36 units/30 s for 10% and 30% MVC, respectively. IHG and INE evoked similar responses at 10% MVC, but IHG elicited higher peak MAP and MSNA at 30% MVC (37 +/- 7 mm Hg (P < 0.05) and 300 +/- 48 units/30 s (P < 0.01) for IHG, respectively). CONCLUSIONS: The data indicate that INE can elicit marked increases in MSNA and cardiovascular responses but that it evokes lower peak responses as compared to IHG. We speculate that possible differences in muscle fiber type composition, muscle mass, and/or muscle architecture of the neck and forearm are responsible for these differences in peak responses.

NASA Discipline Neuroscience↗

Effect of leg exercise training on vascular volumes during 30 days of 6 degrees head-down bed rest

Plasma and red cell volumes, body density, and water balance were measured in 19 men (32-42 yr) confined to bed rest (BR). One group (n = 5) had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise for 60 min/day (ITE; n = 7), and the third near-maximal intermittent isokinetic exercise for 60 min/day (IKE; n = 7). Caloric intake was 2,678-2,840 kcal/day; mean body weight (n = 19) decreased by 0.58 +/- 0.35 (SE) kg during BR due to a negative fluid balance (diuresis) on day 1. Mean energy costs for the NOE, and IKE, and ITE regimens were 83 (3.6 +/- 0.2 ml O2.min-1.kg-1), 214 (8.9 +/- 0.5 ml.min-1.kg-1), and 446 kcal/h (18.8 +/- 1.6 ml.min-1.kg-1), respectively. Body densities within groups and mean urine volumes (1,752-1,846 ml/day) between groups were unchanged during BR. Resting changes in plasma volume (ml/kg) after BR were -1.5 +/- 2.3% (NS) in ITE, -14.7 +/- 2.8% (P less than 0.05) in NOE, and -16.8 +/- 2.9% (P less than 0.05) in IKE, and mean water balances during BR were +295, -106, and +169 ml/24 h, respectively. Changes in red cell volume followed changes in plasma volume. The significant chronic decreases in plasma volume in the IKE and NOE groups and its maintenance in the ITE group could not be accounted for by water balance or by responses of the plasma osmotic, protein, vasopressin, or aldosterone concentrations or plasma renin activity. There was close coupling between resting plasma volume and plasma protein and osmotic content.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Regulatory Physiology↗

Fatigue mechanisms in patients with cancer: effects of tumor necrosis factor and exercise on skeletal muscle

Fatigue is a common adverse effect of cancer and its therapy. However, the specific mechanisms underlying cancer fatigue are unclear. One physiologic mechanism may involve changes in skeletal muscle protein stores or metabolite concentration. A reduction in skeletal muscle protein stores may result from endogenous tumor necrosis factor (TNF) or from TNF administered as antineoplastic therapy. This muscle wasting would require patients to exert an unusually high amount of effort to generate adequate contractile force during exercise performance or during extended periods of sitting or standing. This additional effort could result in the onset of fatigue. Additionally, cancer fatigue may develop or become exacerbated during exercise as a consequence of changes in the concentration of skeletal muscle metabolites. These biochemical alterations may interfere with force that is produced by the muscle contractile proteins. These physiologic changes may play a role in the decision to include exercise in the rehabilitation plans of patients with cancer. They also may affect ideas about fatigue.

Review, Tutorial↗

Comparison of different cooling regimes within a shortened liquid cooling/warming garment on physiological and psychological comfort during exercise

The aim of this study was to compare the effectiveness of different cooling regime intensities to maintain physiological and subjective comfort during physical exertion levels comparable to that engaged in during extravehicular activities (EVA) in space. We studied eight subjects (six males, two females) donned in our newly developed physiologically based shortened liquid cooling/warming garment (SLCWG). Rigorous (condition 1) and mild (condition 2) water temperature cooling regimes were compared at physical exertion levels comparable to that performed during EVA to ascertain the effectiveness of a lesser intensity of cooling in maintaining thermal comfort, thus reducing energy consumption in the portable life support system. Exercise intensity was varied across stages of the session. Finger temperature, rectal temperature, and subjective perception of overall body and hand comfort were assessed. Finger temperature was significantly higher in the rigorous cooling condition and showed a consistent increase across exercise stages, likely due to the restriction of heat extraction because of the intensive cold. In the mild cooling condition, finger temperature exhibited an overall decline with cooling, indicating greater heat extraction from the body. Rectal temperature was not significantly different between conditions, and showed a steady increase over exercise stages in both rigorous and mild cooling conditions. Ratings of overall comfort were 30% higher (more positive) and more stable in mild cooling (p<0.001). The mild cooling regime was more effective than rigorous cooling in allowing the process of heat exchange to occur, thus maintaining thermal homeostasis and subjective comfort during physical exertion.

NASA Discipline Life Sciences Technologies↗

Gravity-independent constant force resistive exercise unit

This invention describes a novel gravity-independent exercise unit designed for use in microgravity, or on the ground, as a means by which to counter muscle atrophy and bone degradation due to disuse or underuse. Modular resistive packs comprising constant torque springs provide constant force opposing the withdrawal of an exercise cable from the device. In addition to uses within the space program, the compact resistive packs of the CFREU allow the unit to be small enough for easy use as a home gym for personal use, or as a supplement for rehabilitation programs. Resistive packs may be changed conveniently out of the CFREU according to the desired exercise regimen. Thus, the resistive packs replace the need for expensive, heavy, and bulky traditional weight plates. The CFREU may be employed by hospitals, rehabilitation and physical therapy clinics, and other related professional businesses.

Colosky, Jr., Paul E.↗

Effects of Different Lifting Cadences on Ground Reaction Forces during the Squat Exercise

The purpose of this investigation was to determine the effect of different cadences on the ground reaction force (GRF(sub R)) during the squat exercise. It is known that squats performed with greater acceleration will produce greater inertial forces; however, it is not well understood how different squat cadences affect GRF(sub R). It was hypothesized that faster squat cadences will result in greater peak GRF(sub R). METHODS: Six male subjects (30.8+/-4.4 y, 179.5+/-8.9 cm, 88.8+/-13.3 kg) with previous squat experience performed three sets of three squats using three different cadences (FC = 1 sec descent/1 sec ascent; MC = 3 sec descent/1 sec ascent; SC = 4 sec descent/2 sec ascent) with barbell mass equal to body mass. Ground reaction force was used to calculate inertial force trajectories of the body plus barbell (FI(sub system)). Forces were normalized to body mass. RESULTS: Peak GRF(sub R) and peak FI(sub system) were significantly higher in FC squats compared to MC (p=0.0002) and SC (p=0.0002). Range of GRF(sub R) and FI(sub system) were also significantly higher in FC compared to MC (p<0.05), and MC were significantly higher than SC (p<0.05). DISCUSSION: Faster squat cadences result in significantly greater peak GRF(sub R) due to the inertia of the system. GRF(sub R) was more dependent upon decent cadence than on ascent cadence. PRACTICAL APPLICATION: This study demonstrates that faster squat cadences produce greater ground reaction forces. Therefore, the use of faster squat cadences might enhance strength and power adaptations to long-term resistance exercise training. Key Words: velocity, weight training, resistive exercise

Bentley, Jason R.↗

Advanced resistive exercise device

The present invention relates to an exercise device, which includes a vacuum cylinder and a flywheel. The flywheel provides an inertial component to the load, which is particularly well suited for use in space as it simulates exercising under normal gravity conditions. Also, the present invention relates to an exercise device, which has a vacuum cylinder and a load adjusting armbase assembly.

Raboin, Jasen L.↗

Efficacy, Safety and Mechanisms of Blood Flow Restricted Exercise

This 20 minute talk will review studies in the peer-reviewed literature related to the effectiveness of blood flow restricted exercise as an exercise training program. There is controversy regarding the talk with cover the effectiveness of various exercise protocols and these differences will be compared and contrasted. Unpublished data from my laboratory at Syracuse University will be presented (see other abstract), as well as some unpublished work from the labs of Manini, Clark and Rasmussen (none are NASA funded).

Ploutz-Snyder, Lori↗

Non-exercise Estimation of V02max Using a Dichotomy of Meeting or Not Meeting DHHS Physical Activity Recommendations

The physical activity guidelines (PAG) established by the US Dept. of Health and Human Services in 2008 is consistent with a rating of >/= 6 on the 11-point NASA Physical Activity Status Scale (PASS). Wier, et. al. developed non-exercise models for estimating VO2(sub max) from a combination of PASS, age, gender and either waist girth (WG) (R = 0.810, SEE= 4.799 ml/kg/min), %Fat (R = 0. 817, SEE = 4.716 ml/kg/min) or BMI (R = 0.802, SEE = 4.900 ml . kg-1. min -1 ). PURPOSE: to develop non-exercise models to estimate VO2max from age, gender, body composition (WG, %Fat, BMI) and PASS dichotomized at meets or does not meet the PAG (PAG-PASS), and to compare the accuracy of the PAG-PASS models with the models using the 11-point PASS. METHODS: 2417 men and 384 women were measured for VO2max by indirect calorimetry (RER >1.1); age (yr), gender by M = 1, W = 0; WG at the umbilicus; %fat by skin-folds, BMI by weight (kg) divided by height squared (m 2 ) , and PAGPASS by PASS < 6 = 0 and =/> 6 = 1. RESULTS: Three models were developed by multiple regression to estimate VO2(sub max) from age, gender, PAG-PASS and either WG (R = 0.790, SEE=5.019 ml/kg/min), %FAT (R= 0.080, SEE = 4.915 ml/kg/min) or BMI (R = 0.777, SEE = 5.162ml/kg/min). Cross-validation by the PRESS technique confirmed these statistics. Simple correlations between measured VO2(sub max) and estimates from the PAG-PASS models with WG, %Fat and BMI were 0.790, 0.800 and 0.777, minimally different from the correlations obtained with the PASS models (0.810, 0.810, and 0.802). PAG-PASS and PASS model constant errors were also similar: < 1 ml/kg/min for subsamples of age, gender, PASS and for VO2(sub max) between 30 and 50 ml/kg/min (70% of the sample) but > 1 ml/kg/min for VO2(sub max) <30 and >50 ml/kg/min. CONCLUSIONS: Non-exercise models using the combined effects of age, gender, body composition and the dichotomized PAG-PASS provide estimates of VO2(sub max) that are accurate for most adults, and the accuracy of these models are similar to previously published models using the 11-point PASS.

Wier, Larry T.↗

The Gravity of LBNP Exercise: Lessons Learned from Identical Twins in Bed for 30 Days

Microgravity leads to cardiovascular deconditioning in humans, which is manifested by post-flight reduction of orthostatic tolerance and upright exercise capacity. During upright posture on Earth, blood pressures are greater in the feet than at heart or head levels due to gravity's effects on columns of blood in the body. During exposure to Microgravity, all gravitational blood pressures disappear. Presently, there is no exercise hardware available for space flight to provide gravitational blood pressures to tissues of the lower body. We hypothesized that 40 minutes of supine treadmill running per day in a LBNP chamber at 1.0 to 1.2 body weight (approximately 50 - 60 mm Hg LBNP) with a 5 min resting, nonexercise LBNP exposure at 50 mm Hg after the exercise session will maintain aerobic fitness orthostatic tolerance, and selected parameters of musculoskeletal function during 30 days of bed rest (simulated microgravity). This paper is an interim report of some of our findings on 16 subjects.

Hargens, Alan R.↗

Vibration Isolation and Stabilization System for Spacecraft Exercise Treadmill Devices

A novel, passive system has been developed for isolating an exercise treadmill device from a spacecraft in a zero-G environment. The Treadmill 2 Vibration Isolation and Stabilization System (T2-VIS) mechanically isolates the exercise treadmill from the spacecraft/space station, thereby eliminating the detrimental effect that high impact loads generated during walking/running would have on the spacecraft structure and sensitive microgravity science experiments. This design uses a second stage spring, in series with the first stage, to achieve an order of magnitude higher exercise- frequency isolation than conventional systems have done, while maintaining desirable low-frequency stability performance. This novel isolator design, in conjunction with appropriately configured treadmill platform inertia properties, has been shown (by on-orbit zero-G testing onboard the International Space Station) to deliver exceedingly high levels of isolation/ stability performance.

Fialho, Ian↗

Exercise Device Would Exert Selectable Constant Resistance

An apparatus called the resistive exercise device (RED) has been proposed to satisfy a requirement for exercise equipment aboard the International Space Station (ISS) that could passively exert a selectable constant load on both the outward and return strokes. The RED could be used alone; alternatively, the RED could be used in combination with another apparatus called the treadmill with vibration isolation and stabilization (TVIS), in which case the combination would be called the subject load device (SLD). The basic RED would be a passive device, but it could incorporate an electric motor to provide eccentric augmentation (augmentation to make the load during inward movement greater than the load during outward movement). The RED concept represents a unique approach to providing a constant but selectable resistive load for exercise for the maintenance and development of muscles. Going beyond the original ISS application, the RED could be used on Earth as resistive weight training equipment. The advantage of the RED over conventional weight-lifting equipment is that it could be made portable and lightweight.

Smith, Damon C.↗

Verification, Validation and Credibility Assessment of a Computational Model of the Advanced Resistive Exercise Device (ARED)

The Advanced Resistive Exercise Device (ARED) is the resistive exercise device used by astronauts on the International Space Station (ISS) to mitigate bone loss and muscle atrophy due to extended exposure to microgravity (micro g). The Digital Astronaut Project (DAP) has developed a multi-body dynamics model of biomechanics models for use in spaceflight exercise physiology research and operations. In an effort to advance model maturity and credibility of the ARED model, the DAP performed verification, validation and credibility (VV and C) assessment of the analyses of the model in accordance to NASA-STD-7009 'Standards for Models and Simulations'.

Werner, C. R.↗