Spill Prevention Control and Countermeasures (SPCC) and Aboveground Storage Tank (AST) Annual Oil Discharge Prevention Briefing Training [Slides]
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .
Grays Harbor Wind LLC (GHW) is proposing to develop a floating offshore wind farm offshore of west Grays Harbor County, Washington (Grays Harbor). The proposed GHW Offshore Wind Project (Project) would entail construction, installation and operation of a 1,000-megawatt (MW) offshore wind farm consisting of approximately 75 floating units, each containing a floating foundation and wind turbine generator (WTG). The Project location is approximately 25 miles (21.7 nautical miles [nmi]) offshore west of Grays Harbor, at waters depths of 360 to 700 feet. The Pacific Northwest National Laboratory (PNNL) was contracted by Herrera Environmental Consultants, Inc. on behalf of GHW to carry out this preliminary scoping study to evaluate baseline conditions and potential effects on fish and marine mammals from development and operation of a floating offshore wind farm installed within a designated area off the coast of Washington1. Floating offshore wind units installed in an ocean environment as part of the Project would interact with marine wildlife. This Study report provides an initial data aggregation and analysis, using publicly available data, of the Project effects, both negative and positive, on the marine environment. The scope of this assessment is limited by the fact that the Project development is presently at the conceptual level. Data on marine organisms were aggregated and evaluated; however seabirds were evaluated by Herrera Environmental Consulting and, along with bats, were not included in the scope of this study. Significant additional work is necessary to characterize ocean, seafloor, and environmental conditions; select appropriate floating offshore wind technologies; identify construction methods and locations; and assess facility locations, including electrical interconnection. Data aggregation and analysis of seabirds and bats is also needed. Evaluation of the full range of potential environmental effects would be conducted following an award of a lease from the Bureau of Ocean Energy Management (BOEM) as part of the leasing, National Environmental Policy Act (NEPA)/State Environmental Policy Act (SEPA) environmental review and permitting processes. While this initial data aggregation and analysis uses best available public scientific information and current assumptions about the Project configuration, the effects discussed herein are based on the status of review to-date and may change as Project-specific details are developed.
This report provides the results of a wetland delineation conducted to support operational logistics for construction of a high-pressure water line that is planned to occur near a wetland at Los Alamos National Laboratory (LANL). The wetland reach is on the mesa edge in Technical Area (TA)-55 above the Mortandad Canyon watershed. This area has not been previously delineated; however, it drains to a canyon bottom where LANL updated a delineation in 2017 for the wetland adjacent to Technical Areas (TAs) 25, 48, and 55.
Abstract not provided.
Most construction projects at LANL are subject to a EPA regulated storm water discharge permit (NPDES Construction General Permit). Each identified non-compliance is a regulatory liability to both the subcontractor & Triad.
The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take action at Los Alamos National Laboratory (LANL) within the upper Pajarito Canyon 100-year (yr.) floodplain at Technical Area (TA) 08. This action consists of installation of a 3-strand smooth wire fence to create an operational boundary in a radius of 1250 feet (ft.) from the TA-08 High Explosive (HE) Transfer Facility (Figure 1). The proposed fence is intended to provide a barrier between the public and direct access to the HE Transfer Facility.
The purpose of the document is to show an example of a Multi-Sector General Permit environmental compliance program inspection structure to new software provider (new provider is under contract w/ LANL) to begin setting up new database.
Los Alamos National Laboratory (LANL) operates four mesa-top meteorology towers: Technical Area (TA) 06, TA-49, TA-53, and TA-54. An additional tower is located in Mortandad Canyon (TA-5 MDCN), and a rain gauge at North Community (NCOM). A description of the meteorology monitoring network is found in Dewart and Boggs (2014). Mesa-top towers are instrumented at 1.2 meters (m), 11.5 m, 23 m, and 46 m. In addition, TA-06 is instrumented at 92 m. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected every 15 minutes. Range checking is done on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by meteorologists to identify bad data not identified by range checking. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement as required. Data completeness is determined by the number of total 15-minute records available versus the total number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, containing bad data, can be recalled from program archival storage.
Abstract not provided.
The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take action at Los Alamos National Laboratory (LANL) to install post and cable or in-kind barriers along West Road at selected locations near the Los Alamos County ice-skating rink in Los Alamos Canyon (Figure 1). The proposed project is intended to improve vehicular and pedestrian safety on West Road by reducing traffic hazards associated with unsafe roadside parking and reduce wildland fire hazards associated with vehicles driving and parking on vegetation. West Road crosses approximately 0.35 miles (mi.) (1,900 feet (ft.)) of the Los Alamos Canyon floodplain at the bottom of Los Alamos Canyon. Project activities within the floodplain include blocking access to the informal roadside parking along either side of West Road in Los Alamos Canyon.
SuiteGoo is a liquid product used to detect "undetectable" material traces. It is used when you need to improve detection limits, anywhere where cotton swiping is used, and anywhere where cotton swiping fails. It is also used by law enforcement to find DNA from fingerprints, used by health care to detect the presence of viruses and bacteria, used by emergency response to detect explosive traces, and used by environmental management to detect pollutant traces.
In 2021, non-viable avian eggs and one nestling were opportunistically collected at Los Alamos National Laboratory (LANL) near open detonation sites located at Technical Area (TA) 16 burn grounds and TA-36 Minie. Similar to previous years, nestboxes were monitored at TA-39 Point 6, however, no avian samples were available for opportunistic collection. Samples were evaluated for inorganic elements (mostly metals), dioxins, and furans. One ash-throated flycatcher (Myiarchus cinerascens) egg sample was collected from TA-16 burn grounds. One ash-throated flycatcher and one mountain bluebird (Sialia currucoides) egg sample and one deceased western bluebird (Sialia mexicana) nestling sample were collected from TA-36 Minie. Concentrations of inorganic elements observed in this study were compared with the regional statistical reference level (RSRL) which is the upper-level bounds of background concentrations (mean + three standard deviations = 99% confidence interval). Several inorganic elements were not detected in avian eggs. Most inorganic elements detected were below the RSRL and all were the lowest observable adverse effect level (LOAEL), when available. The nestling collected from TA-36 did not contain detectable concentrations of dioxin or furan congeners. These data suggest that inorganic and organic element concentrations in eggs and nestlings are not of ecological concern. More data are needed to make a robust assessment and to evaluate trends over time.
The following information will be presented during the February 23, 2022 Accord Pueblos Technical Meeting. The purpose of the study is to determine if natural thermal conditions are preventing the attainment of Coldwater Aquatic Life Use in the perennial reach of the upper Sandia Canyon Assessment Unit (Sandia AU). The New Mexico Water Quality Standards allow for a change in the designated use if a Use Attainability Analysis (UAA) demonstrates that the use is not attainable due to one or more of six factors listed in 40 CFR 131.10(g), including naturally occurring pollutant concentrations. The Sandia AU is located in a perennial reach of upper Sandia Canyon between Sigma Canyon and NPDES Outfall 001. The classified Segment 20.6.4.126 NMAC comprises perennial waters within Los Alamos National Laboratory boundaries and includes the Sandia AU. Persistent surface flows originate from NPDES permitted effluent releases. These releases have occurred since the early 1950’s and continue today. The UAA examines several lines of evidence. NMED’s Air-Water Temperature Correlation (AWTC) model is used for identifying appropriate stream classifications and attainable aquatic life use subcategories. The model correlates between July average air temperatures (ATEMP) and maximum weekly average stream temperatures. Air temperatures are obtained from PRISM and LANL Meteorological Towers and used to derive ATEMP. Thermographs were placed in the Sandia AU to obtain measured stream temperatures during summer months when stream temperatures are the highest. Measured data is used with AWTC modeled data to determine if the Sandia AU is meeting its natural air temperature driven thermal condition.
The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction and upgrade activities in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed upgrades are intended to improve range safety to help fulfill the mission requirements of maintaining a trained and qualified armed Protective Force.
Abstract not provided.