Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Tchebycheff-based multi-objective combined with a PSO–SQP dynamic real-time optimization framework for cycling energy systems

The aim in this work is to develop an optimization framework to address cycling of baseload energy systems due to the penetration of renewables into the grid. The developed strategy corresponds to a multi-objective and dynamic real-time optimization (MOO-DRTO) framework applied to a postcombustion MEA-based CO 2 capture process from a baseload coal-fired power plant under cycling conditions. A Tchebycheff-based method is used for the multi-objective optimization (MOO) component. Also, a hybrid approach consisting of Particle Swarm Optimization (PSO) and Sequential Quadratic Programming (SQP) is implemented for the first time in process systems engineering to solve the dynamic real-time optimization (DRTO) component. The objectives considered in the MOO-DRTO framework are economic and environmental. The proposed MOO-DRTO strategy is successfully implemented and 24-h optimal output trajectories for the carbon capture system under cycling are generated. Also, the optimal compromise is chosen from the Pareto front according to a set of selected weights for the objectives with minimal interaction between the framework and decision maker. The results indicated that the developed framework has potential to be extended to plant-wide optimization applications under cycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clouds and the Earth's Radiant Energy System (CERES) Visualization Single Satellite Footprint (SSF) Plot Generator

The first Clouds and the Earth's Radiant Energy System (CERES) instrument will be launched in 1997 to collect data on the Earth's radiation budget. The data retrieved from the satellite will be processed through twelve subsystems. The Single Satellite Footprint (SSF) plot generator software was written to assist scientists in the early stages of CERES data analysis, producing two-dimensional plots of the footprint radiation and cloud data generated by one of the subsystems. Until the satellite is launched, however, software developers need verification tools to check their code. This plot generator will aid programmers by geolocating algorithm result on a global map.

Barsi, Julia A.↗

Evaluating the Calibration and Validation of the Clouds and the Earth’s Radiant Energy System (CERES) instruments on Terra and Aqua Over Twenty Years

Six Clouds and the Earth’s Radiant Energy System (CERES) instruments on four satellites are used to produce a global continuous multi-decadal record of Earth’s radiation budget (ERB) at the top-of-atmosphere (TOA). Each CERES instrument was calibrated and characterized on the ground before launch, while post-launch calibration is conducted using on-board calibration sources. The performance of the CERES instruments is verified using vicarious approaches involving both Earth and celestial targets. In this paper, we describe the calibration and validation approach and demonstrate the performance of the CERES instruments on the Terra and Aqua spacecrafts over the twenty-year period since launch. Validation results demonstrate that after applying the appropriate calibration corrections, all four instruments are stable and perform consistently with each other. Comparisons of observations between instruments on the two spacecrafts during orbital crossings further confirm the consistent performance across all instruments over the twenty year period.

Terra↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Wind and solar energy droughts: Potential impacts on energy system dynamics and research needs

This Perspective article provides a brief overview of the topic of wind and solar energy droughts (henceforth WSDs). It does not attempt to provide a complete literature review of the subject but rather highlights some of the main concepts associated with WSDs. These include wind and solar energy drought definitions and metrics; meteorological conditions producing WSDs; a comparison of their characteristics with hydrologic droughts and hydropower droughts; model-based and observational datasets useful for WSD analyses; the linkage of WSDs to transmission, storage, and demand response; the potential impacts of WSDs vs energy demand variations; wind and solar flood events; WSD predictability; WSD dependency on climate modes of variability; climate change impacts on WSDs; and the special challenge of evaluating the characteristics of WSDs in developing countries that have limited historical data available. Finally, the manuscript identifies research areas that the authors believe would provide immediate benefit to energy system planners.

14 SOLAR ENERGY↗

Aerospace energy systems laboratory: Requirements and design approach

The NASA Ames-Dryden Flight Research Facility at Edwards, California, operates a mixed fleet of research aircraft employing nickel-cadmium (NiCd) batteries in a variety of flight-critical applications. Dryden's Battery Systems Laboratory (BSL), a computerized facility for battery maintenance servicing, has developed over two decades into one of the most advanced facilities of its kind in the world. Recently a major BSL upgrade was initiated with the goal of modernization to provide flexibility in meeting the needs of future advanced projects. The new facility will be called the Aerospace Energy Systems Laboratory (AESL) and will employ distributed processing linked to a centralized data base. AESL will be both a multistation servicing facility and a research laboratory for the advancement of energy storage system maintenance techniques. This paper describes the baseline requirements for the AESL and the design approach being taken for its mechanization.

Glover, Richard D.↗

Aerospace Energy Systems Laboratory - Requirements and design approach

The NASA Ames/Dryden Flight Research Facility operates a mixed fleet of research aircraft employing NiCd batteries in a variety of flight-critical applications. Dryden's Battery Systems Laboratory (BSL), a computerized facility for battery maintenance servicing, has evolved over two decades into one of the most advanced facilities of its kind in the world. Recently a major BSL upgrade was initiated with the goal of modernization to provide flexibility in meeting the needs of future advanced projects. The new facility will be called the Aerospace Energy Systems Laboratory (AESL) and will employ distributed processing linked to a centralized data base. AESL will be both a multistation servicing facility and a research laboratory for the advancement of energy storage system maintenance techniques. This paper describes the baseline requirements for the AESL and the design approach being taken for its mechanization.

Glover, Richard D.↗

Battery model for electrical power system energy balance

A model to simulate nickel-cadmium battery performance and response in a spacecraft electrical power system energy balance calculation was developed. The voltage of the battery is given as a function of temperature, operating depth-of-charge (DOD), and battery state-of-charge. Also accounted for is charge inefficiency. A battery is modeled by analysis of the results of a multiparameter battery cycling test at various temperatures and DOD's.

Hafen, D. P.↗

The Effects of Different Footprint Sizes and Cloud Algorithms on the Top-Of-Atmosphere Radiative Flux Calculation from the Clouds and Earth’s Radiant Energy System (CERES) Instrument on Suomi National Polar-Orbiting Partnership (NPP)

Only one Clouds and Earth’s Radiant Energy System (CERES) instrument is onboard the Suomi National Polar-orbiting Partnership (NPP) and it has been placed in cross-track mode since launch; it is thus not possible to construct a set of angular distribution models (ADMs) specific for CERES on NPP. Edition 4 Aqua ADMs are used for flux inversions for NPP CERES measurements. However, the footprint size of NPP CERES is greater than that of Aqua CERES, as the altitude of the NPP orbit is higher than that of the Aqua orbit. Furthermore, cloud retrievals from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS), which are the imagers sharing the spacecraft with NPP CERES and Aqua CERES, are also different. To quantify the flux uncertainties due to the footprint size difference between Aqua CERES and NPP CERES, and due to both the footprint size difference and cloud property difference, a simulation is designed using the MODIS pixel-level data, which are convolved with the Aqua CERES and NPP CERES point spread functions (PSFs) into their respective footprints. The simulation is designed to isolate the effects of footprint size and cloud property differences on flux uncertainty from calibration and orbital differences between NPP CERES and Aqua CERES. The footprint size difference between Aqua CERES and NPP CERES introduces instantaneous flux uncertainties in monthly gridded NPP CERES measurements of less than 4.0 W/sq. m for SW (shortwave) and less than 1.0 W/sq. m for both daytime and nighttime LW (longwave). The global monthly mean instantaneous SW flux from simulated NPP CERES has a low bias of 0.4 W/sq. m when compared to simulated Aqua CERES, and the root-mean-square (RMS) error is 2.2 W/sq. m between them; the biases of daytime and night- time LW flux are close to zero with RMS errors of 0.8 and 0.2 W/sq. m. These uncertainties are within the uncertainties of CERES ADMs. When both footprint size and cloud property (cloud fraction and optical depth) differences are considered, the uncertainties of monthly gridded NPP CERES SW flux can be up to 20 W/sq. m in the Arctic regions where cloud optical depth retrievals from VIIRS differ significantly from MODIS. The global monthly mean instantaneous SW flux from simulated NPP CERES has a high bias of 1.1 W/sq. m and the RMS error increases to 5.2 W/sq. m. LW flux shows less sensitivity to cloud property differences than SW flux, with uncertainties of about 2 W/sq. m in the monthly gridded LW flux, and the RMS errors of global monthly mean daytime and nighttime fluxes increase only slightly. These results highlight the importance of consistent cloud retrieval algorithms to maintain the accuracy and stability of the CERES climate data record.

Su, Wenying↗

Flexible, Multipurpose Laboratory Advances Building and Thermal Energy Systems: Expanding Evaluation and Development of Grid-Interactive Buildings

Robust hardware and controls are necessary to ensure results match their intent before they can be used broadly. However, this often requires multiple field experiments in a variety of climate zones. In the field, it is more difficult to obtain information on other important factors, such as thermal, grid, and occupant interaction. Gaps also exist in understanding the performance degradation and life cycle of thermal energy systems as they relate to buildings. There is a lack of robust, high-quality performance data for projects at scale; this data can be expensive to produce and often remain proprietary.

30 DIRECT ENERGY CONVERSION↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A nuclear-hydrogen hybrid energy system with large-scale storage: A study in optimal dispatch and economic performance in a real-world market

Here a study in optimal dispatch and economic analysis of a novel nuclear hybrid energy system (NHES) with large-scale hydrogen storage and a novel control scheme is conducted. The control scheme makes charge and discharge decisions by using the real-time electricity price relative to the historical price distribution. The pricing data is taken from the ERCOT Houston and West load zones with different price oscillations. Six case control studies with different levels of aggressiveness were chosen for each load zone for a total of 12 case studies. It is found that in a high price volatility load zone, a more aggressive control strategy maximizes revenue, while in a less oscillatory load zone, a moderate control strategy performs better. The NHES can store energy when the price is low and sell additional electricity when the price is high, as well as participate in the ancillary services market. Due to these advantages, the NHES can generate 10–40 million USD more revenue annually than a stand-alone nuclear plant. Due to higher costs, the NHES has a higher LCOE (81.36 USD/MWh) than a stand-alone plant (68.66 USD/MWh); however, the LCOE of the NHES is still comparable to other new forms of electricity generation. It is found that both the NHES and the stand-alone plant are not economical in the existing electricity market. Due to the extra revenue generated, the hybrid system has a positive annual cashflow whereas the stand-alone plant does not. It is found that the hybrid plant needs less cost subsidy than a stand-alone plant to become economical.

08 HYDROGEN↗

US energy system transitions under cumulative emissions budgets

Cumulative emissions budgets are increasingly being used by decision makers and analysts to understand emissions reductions and associated transitions in the context of long-term goals such as limiting global mean temperature increase over the century to 1.5 or 2°C (IPCC, 2014). While previous studies have explored the implications of cumulative emissions budgets for the global economy, few studies have conducted regional and national-level analyses (Iyer et al., 2015; Riahi et al., 2015). This paper explores cumulative emissions budgets through 2050 consistent with the 1.5 and 2°C long-term temperature goals in the context of the United States. We employ a state-level model of the United States embedded within a global human-Earth system model (GCAM-USA) to study the implications of such budgets for the U.S. energy system (Iyer et al., 2017a; Iyer et al., 2017b). Our results show that achieving the stringent cumulative emissions budgets entails accelerated deployment of energy conserving technology, almost complete decarbonization of the power sector and increased electrification of buildings and industrial end-use sectors and decarbonization of transport employing a combination of electrification and the substitution of bioenergy for fossil fuels by the mid-century. We also find substantial state-level differences in the relative roles of these decarbonization strategies. Furthermore, our results highlight that increased ambition in the near-term will be valuable in setting the stage for smoother transformations in the future to achieve stringent cumulative emissions budgets consistent with long-term temperature goals established by the international community.

Feijoo, Felipe↗

Can economic drivers enable an affordable, reliable, and resilient energy system in rural Alaska?

Price subsidies, such as the Alaska Power Cost Equalization (PCE) program, are intended to provide affordable energy. However, these economic drivers may be barriers to a clean energy transition and economic development, especially in rural Alaska. Reliable and affordable energy, a challenge in rural Alaska, is the foundation for individual and community security and economic development. Addressing the climate change crisis requires a sustainable transition to decarbonized energy systems that are more equitable, reliable, and affordable.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Variability and associated uncertainty in image analysis for soiling characterization in solar energy systems

The accumulation of soiling on photovoltaic modules and on the mirrors of concentrating solar power systems causes non-negligible energy losses with economic consequences. These challenges can be mitigated, or even prevented, through appropriate actions if the magnitude of soiling is known. Particle counting analysis is a common procedure to characterize soiling, as it can be easily performed on micrographs of glass coupons or solar devices that have been exposed to the environment. Particle counting does not, however, yield invariant results across institutions. The particle size distribution analysis is affected by the operator of the image analysis software and the methodology utilized. The results of a round-robin study are presented in this work to explore and elucidate the uncertainty related to particle counting and its effect on the characterization of the soiling of glass surfaces used in solar energy conversion systems. An international group of soiling experts analyzed the same 8 micrographs using the same open-source ImageJ software package. The variation in the particle analyses results were investigated to identify specimen characteristics with the lowest coefficient of variation (CV) and the least uncertainty among the various operators. The mean particle diameter showed the lowest CV among the investigated characteristics, whereas the number of particles exhibited the largest CV. Additional parameters, such as the fractional area coverage by particles and parameters related to the distribution's shape yielded intermediate CV values. These results can provide insights on the magnitude inter-lab variability and uncertainty for optical and microscope-based soiling monitoring and characterization.

14 SOLAR ENERGY↗