Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Overview of 12-cm-Diameter, Argon Gas-Puff Experiments and Analyses with >200-ns Implosion Times at 3- to 6-MA Peak Currents

This paper reviews the motivation for, results from, and analyses of 12-cm-diameter argon gas-puff experiments carried out over the last four years on three generators at 3.2- to 6.5-MA peak currents, all with implosion times {>=}200 ns. Using the argon K-shell yield as a metric of implosion quality, high-quality implosions are obtained for an appropriate initial radial mass distribution, i.e., a distribution that is peaked on axis. Higher compressed densities and smaller final radii are observed compared to shell-like initial mass distributions. Theory and data suggest that these distributions mitigate the magnetic Rayleigh-Taylor instability. An energy analysis shows that (1) significant electrical energy is directly coupled to the pinch during the K-shell radiation pulse and (2) conversion of radially-directed kinetic energy into thermal energy is not the dominant mechanism responsible for the pinch K-shell radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Greenbuilt Retrofit Test House Final Report

The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient analysis and energy optimization of solar heating and cooling systems in various configurations

In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used as the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)

14 SOLAR ENERGY↗

A case study on parallel HDF5 dataset concatenation for high energy physics data analysis

In High Energy Physics (HEP), experimentalists generate large volumes of data that, when analyzed, helps us better understand the fundamental particles and their interactions. This data is often captured in many files of small size, creating a data management challenge for scientists. In order to better facilitate data management, transfer, and analysis on large scale platforms, it is advantageous to aggregate data further into a smaller number of larger files. However, this translation process can consume significant time and resources, and if performed incorrectly the resulting aggregated files can be inefficient for highly parallel access during analysis on large scale platforms. In this paper, we present our case study on parallel I/O strategies and HDF5 features for reducing data aggregation time, making effective use of compression, and ensuring efficient access to the resulting data during analysis at scale. We focus on NOvA detector data in this case study, a large-scale HEP experiment generating many terabytes of data. Here, the lessons learned from our case study inform the handling of similar datasets, thus expanding community knowledge related to this common data management task.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Low-energy Trigger for VERITAS

During the 2007/2008 observing season a low-energy trigger configuration was developed and tested for VERITAS. The configuration makes uses of the small ({approx}35 m) baseline between two of the VERITAS telescopes and employs a much lower discriminator threshold and tighter coincidence window compared to the standard VERITAS trigger. Five hours of Crab Nebula ON/OFF observations were obtained in low-energy mode and were used to test new low-energy analysis algorithms. We present some details of the VERITAS low-energy trigger and the associated data analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSFORM: Catalyzing the Transition to a 21st Century Energy Economy - JISEA 2019 Annual Report

The Joint Institute for Strategic Energy Analysis (JISEA) provides leading-edge, objective, high impact research and analysis to guide transformative global energy investment and policy decisions. Through strategic insights and worldwide dialogue, JISEA explores the intersections of the environmental, social, financial, technological, and political elements of energy systems on the path to a clean energy economy. JISEA's work informs innovative solutions that advance the goals of sustainability, economic prosperity, and resilience. JISEA research and analysis provided decision-making support to industry, the financial sector, and government with a focus on the following strategic areas: Energy Systems Integration and Transformation, Energy in the Global Water-Food Nexus, and Circular Energy Economy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Household Energy Efficiency Analysis for the Hill District, Pennsylvania: Version 2

Many households in the Hill District, Pennsylvania, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for the Hill District.

Communities LEAP↗

Household Energy Efficiency Analysis for the Hill District, Pennsylvania: Version 1

Many households in the Hill District, Pennsylvania, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for the Hill District.

Communities LEAP↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. David↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. D.↗

Nuclear and Renewable Energy Synergies Workshop: Report of Proceedings

Two of the major challenges the U.S. energy sector faces are greenhouse gas emissions and oil that is both imported and potentially reaching a peak (the point at which maximum extraction is reached). Interest in development of both renewable and nuclear energy has been strong because both have potential for overcoming these challenges. Research in both energy sources is ongoing, but relativelylittle research has focused on the potential benefits of combining nuclear and renewable energy. In September 2011, the Joint Institute for Strategic Energy Analysis (JISEA) convened the Nuclear and Renewable Energy Synergies Workshop at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to identify potential synergies and strategic leveraging opportunities betweennuclear energy and renewable energy. Industry, government, and academic thought leaders gathered to identify potential broad categories of synergies and brainstorm topic areas for additional analysis and research and development (R&D). This report records the proceedings and outcomes of the workshop.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Applications analysis of high energy lasers

An analysis and comparison of laser technology with competing technologies were made to determine possible laser applications. The analysis was undertaken as follows: (1) possible applications were listed and categorized; (2) required components were enumerated and the characteristics of these components were extrapolated; (3) complete system characteristics were calculated parametrically for selected applications using the postulated component characteristics; and (4) where possible and appropriate, comparisons were made with competing systems. It was found that any large scale replacement of existing systems and methods by lasers requires many technological advances in laser and associated systems. However, several applications appear feasible, such as low orbit drag make-up, orbit changing, communications, and illumination applications.

Arno, R. D.↗

Validation Methodology to Allow Simulated Peak Reduction and Energy Performance Analysis of Residential Building Envelope with Phase Change Materials: Preprint

Phase change materials (PCM) represent a potential technology to reduce peak loads and HVAC energy consumption in residential buildings. This paper summarizes NREL efforts to obtain accurate energy simulations when PCMs are modeled in residential buildings: the overall methodology to verify and validate Conduction Finite Difference (CondFD) and PCM algorithms in EnergyPlus is presented in thisstudy. It also shows preliminary results of three residential building enclosure technologies containing PCM: PCM-enhanced insulation, PCM impregnated drywall and thin PCM layers. The results are compared based on predicted peak reduction and energy savings using two algorithms in EnergyPlus: the PCM and Conduction Finite Difference (CondFD) algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INTEGRATE: Driving Transformational Change - JISEA 2018 Annual Report

This report demonstrates 2017 highlights of the Joint Institute for Strategic Energy Analysis' (JISEA's) work. The Annual Report overviews JISEA's research and analysis accomplishments in natural gas and methane emissions; nuclear-renewable hybrid energy systems; the Clean Energy Manufacturing Analysis Center's work in global supply chains; the 21st Century Power Partnership; and more.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spectral energy distribution analysis of class I and class II FU Orionis stars

FU Orionis stars (FUors) are eruptive pre-main sequence objects thought to represent quasi-periodic or recurring stages of enhanced accretion during the low-mass star-forming process. We characterize the sample of known and candidate FUors in a homogeneous and consistent way, deriving stellar and circumstellar parameters for each object. We emphasize the analysis in those parameters that are supposed to vary during the FUor stage. We modeled the spectral energy distributions of 24 of the 26 currently known FUors, using the radiative transfer code of Whitney et al. We compare our models with those obtained by Robitaille et al. for Taurus class II and I sources in quiescence periods by calculating the cumulative distribution of the different parameters. FUors have more massive disks: we find that ∼80% of the disks in FUors are more massive than any Taurus class II and I sources in the sample. Median values for the disk mass accretion rates are ∼10{sup –7} M {sub ☉} yr{sup –1} versus ∼10{sup –5} M {sub ☉} yr{sup –1} for standard young stellar objects (YSOs) and FUors, respectively. While the distributions of envelope mass accretion rates for class I FUors and standard class I objects are similar, FUors, on average, have higher envelope mass accretion rates than standard class II and class I sources. Most FUors (∼70%) have envelope mass accretion rates above 10{sup –7} M {sub ☉} yr{sup –1}. In contrast, 60% of the classical YSO sample has an accretion rate below this value. Our results support the current scenario in which changes experimented by the circumstellar disk explain the observed properties of these stars. However, the increase in the disk mass accretion rate is smaller than theoretically predicted, although in good agreement with previous determinations.

79 ASTRONOMY AND ASTROPHYSICS↗

Household Energy Efficiency Analysis for the City of Columbia, South Carolina

Many households in the City of Columbia, South Carolina, could save hundreds of dollars annually on their energy bills, reduce carbon emissions, and improve comfort with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for about 94,000 housing units in Columbia.

Columbia↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗