Small-Signal Stability Impacts of Load and Network Dynamics on Grid-Forming Inverters

This paper presents several stability analyses for grid-forming inverters and synchronous generators considering the dynamics of transmission lines and different load models. Load models are usually of secondary importance compared to generation source models, but as the results show, they play a crucial role in stability studies with the introduction of inverter-based resources. Given inverter control time scales, the implications of considering or neglecting electromagnetic transients of the network are very relevant in the stability assessments. In this paper, we perform eigenvalue analyses for inverter-based resources and synchronous machines connected to a load and explore the effects of multiples models under different network representations. We explore maximum loadability of inverter-based resources and synchronous machines, while analyzing the effects of load and network dynamic models on small-signal stability. The results show that the network representation plays a fundamental role in the stability of the system of different load models. The resulting stability regions are significantly different depending on the source and load model considered.

grid forming inverters↗

On Distributed Model-Free Reinforcement Learning Control with Stability Guarantee

Distributed learning can enable scalable and effective decision making in numerous complex cyber-physical systems such as smart transportation, robotics swarm, power systems, etc. However, the stability of the system is usually not guaranteed in most existing learning paradigms; and this limitation can hinder the wide deployment of machine learning in decision making of safety-critical systems. This paper presents a stability guaranteed distributed reinforcement learning (SGDRL) framework for interconnected linear subsystems, without knowing the subsystem models. While the learning process requires data from a peer-to-peer (p2p) communication architecture, the control implementation of each subsystem is only based on its local state. The stability of the interconnected subsystems will be ensured by a diagonally dominant eigenvalue condition, which will then be used in a model-free RL algorithm to learn the feedback control gains. The RL algorithm structure follows an off-policy iterative framework, with interleaved policy evaluation and policy update steps. We numerically validate our theoretical results by performing simulations on four interconnected sub-systems.

Mukherjee, Sayak↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

An ODE-Enabled Distributed Transient Stability Analysis for Networked Microgrids

Networked microgrid (NMG) exhibits noteworthy resiliency and flexibility benefits for the mutual support from neighboring microgrids. With high penetration of distributed energy resources (DERs) and the associated controls, the transient stability analysis of NMGs is of critical significance. To address the issues of computation burdens and privacy in the centralized transient analysis, this paper devises an ordinary differential equation (ODE)-enabled distributed transient stability (DTS) methodology for NMGs. First, an ODE-based microgrid model is established to capture the dynamics in the droop control of DERs as well as network and load. Further, a distributed DTS is devised for the ODE representation of an NMG, allowing a privacy-preserving transient analysis of each microgrid while accurately reconstructing the frequency dynamics under droop controls in all DERs. In conclusion, extensive tests are performed to verify the validity of the ODE-based microgrid model through both dynamic response and eigenvalue analysis, and the efficacy of the DTS algorithm in simulating the large signal responses and the frequent fluctuations in NMG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Cause of Insufficient Damping in Phase-Locked-Loop and Its Influence

Phase-locked loop (PLL) is a critical component that synchronizes grid-following (GFL) inverter-based resources (IBR) to the grid. Insufficient damping in PLL has been identified as a cause associated with real-world weak grid stability issues. This paper reveals that the second-order low-pass filter deployed in a sophisticated PLL structure can have negative influence on damping performance and lead to system instability when the grid is weak and power generation is low. Improving the PLL damping is illustrated as one of the mitigation approaches. The dynamic study is carried out in electromagnetic transient (EMT) simulation environment. In addition to EMT demonstration, a simplified analytical model of PLL is developed to represent a PLL with the sophisticated structure. The resulting overall analytical model of the entire system is then used for eigenvalue- based analysis to illustrate the influence of PLL on dynamic modes.

Wang, Zhengyu↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Testing the Activation Analysis for Fusion in OpenMC

OpenMC is a community-developed Monte Carlo neutron and photon transport simulation code. It can perform fission simulations such as fixed-source, k-eigenvalue, and subcritical multiplication calculations on models built using either a constructive solid geometry or CAD representation. To explore the use of OpenMC for fusion activation analysis, a detailed model of the Fusion Neutronics Science Facility (FNSF) was first developed for comparisons against an existing SERPENT model. A 90-degree model of FNSF in Standard-Triangle-Language (STL) CAD format was converted to Constructive Solid Geometry (CSG) using each code's built-in functions, and the geometries were validated by ensuring no cells overlapped and no particles were lost during simulations. The neutron fluxes were calculated and compared for multiple components close to the plasma. The results show differences mostly below 1% in fluxes and averaged 8% for activity and decay heat. Here, the work described in this study tests the CAD-based geometry using the DagMC toolkit in OpenMC and compares the activation analysis of OpenMC to SERPENT code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillation Risks of Grid-Following and Grid-Forming Inverter-Based Resources in Series-Compensated Networks

Here, this paper investigates the dynamic behavior of a grid-connected inverter-based resource (IBR) when connected radially to a series compensated line. Potential interactions between the series compensation and the IBR have been identified for both types: grid-following (GFL) or grid-forming (GFM). The study begins with electromagnetic transient (EMT) simulations to demonstrate stability issues. Subsequently, nonlinear analytical models are formulated in the dq frame, validated against the EMT simulation, and leveraged to assess eigenvalues and participation factors. Influencing factors of the dominant oscillation modes have been identified. The analysis results show that series compensation may make a mode associated with the synchronization unit unstable. Furthermore, customized feedback systems are built for the synchronizing loop. Series compensation can increase the sensitivity of the voltage phase angle towards the synchronizing angle, and introduce phase lag in the real power response towards the synchronizing angle. These factors may cause interactions with the phase-locked loop in GFL-IBR systems and with power-based synchronization in GFM-IBR systems, potentially leading to instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Detectability Analysis for Power System Dynamic State Estimation

To guide the measurement placement and selection for dynamic state estimation in power systems, it is important to determine the existence of an observer that can estimate the dynamic states. Past studies have been focused on observability analysis, which determines whether the initial states can be uniquely determined. In this paper, detectability analysis is proposed to determine whether the current states can be estimated as time involving. Through the proposed detectability analysis, the states of an unobservable system can be categorized into the detectable states and undetectable states. It is shown that if the eigenvalues corresponding to the unobservable states are stable, the states are detectable and their estimates will converge to the true ones asymptotically. The study can be used to guide measurement placement and selection.

Detectability, dynamic state estimation↗

Distributed Conditions for Small-signal Stability of Power Grids and Local Control Design

Operating modern power grids with stability guarantees is markedly important. Typical methods for analyzing and certifying power grid stability are largely centralized relying on the ability of the system operator to gather network-wide information and accurately compute the system's eigenvalues. These methods are oftentimes not privacy-preserving and computationally burdensome. They are therefore, not well-suited to modern power grids where small-signal stability has to be evaluated timely, efficiently and in a privacy-preserving fashion. Herein, we introduce a distributed methodology for certifying small-signal stability of power grids and designing the local controllers. First, we analytically derive distributed conditions for network-wide stability that bus agents can inspect using local information. By leveraging these conditions, we then introduce a distributed control design algorithm (DCDA) that can guide the local control design so that stability of the interconnected system is guaranteed. The agents that adopt the proposed distributed algorithm are responsible for tuning their local controllers, producing their local control commands and ensuring that their local stability condition is met. The system operator is only responsible for verifying network-wide stability upon receiving affirmative responses from all agents and, announcing, that the overall system is stable. The proposed DCDA algorithm is numerically validated via simulations using the IEEE 39-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

Propagating Parameter Uncertainty in Power System Nonlinear Dynamic Simulations Using a Koopman Operator-Based Surrogate Model

In this work, we propose a Koopman operator-based surrogate model for propagating parameter uncertainties in power system nonlinear dynamic simulations. First, we augment a priori known state-space model by reformulating parameters deemed uncertain as pseudo-state variables. Then, we apply the Koopman operator theory to the resulting state-space model and obtain a linear dynamical system model. This transformation allows us to analyze the evolution of the system dynamics through its Koopman eigenfunctions, eigenvalues, and modes. Of particular importance for this letter, the obtained linear dynamical system is a surrogate that enables the evaluation of parameter uncertainties by simply perturbing the initial conditions of the Koopman eigenfunctions associated with the pseudo-state variables. Simulations carried out on the New England test system reveal the excellent performance of the proposed method in terms of accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Type of Weak Grid IBR Oscillations

This letter presents the discovery of a new type oscillations associated with inverter-based resources (IBRs) in weak grids. While typical weak grid oscillations become worse when the grid strength decreases and the power exporting level increases, this new type of oscillations appear when the grid becomes weaker and the power exporting level decreases. Electromagnetic transient (EMT) simulation results are presented, along with eigenvalue loci for a varying power. The notable signatures of such oscillations are also remarked. In further analysis, a feedback system consisting of two blocks is derived with one block associated with the phase-locked-loop (PLL) and the other associated with the rest of the system. Here, this feedback system quantitatively demonstrates why insufficient damping in the PLL may be an issue for stability. Open-loop analysis shows that a larger phase lag in angle tracking in the low-frequency range due to high power exporting level at the weak grid condition is beneficial to the open-loop poles introduced by the PLL. And this is the reason why such oscillations may appear when power is ramping down.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis and Mitigation of Cascading Failures Using a Stochastic Interaction Graph with Eigen-analysis

In studies on complex network systems using graph theory, eigen-analysis is typically performed on an undirected graph model of the network. However, when analyzing cascading failures in a power system, the interactions among failures suggest the need for a directed graph beyond the topology of the power system to model directions of failure propagation. To accurately quantify failure interactions for effective mitigation strategies, this paper proposes a stochastic interaction graph model and associated eigen-analysis. Different types of modes on failure propagations are defined and characterized by the eigenvalues of a stochastic interaction matrix, whose absolute values are unity, zero, or in between. Finding and interpreting these modes helps identify the probable patterns of failure propagation, either local or widespread, and the participating components based on eigenvectors. Then, by lowering the failure probabilities of critical components highly participating in a mode of widespread failures, cascading can be mitigated. Here, the validity of the proposed stochastic interaction graph model, eigen-analysis and the resulting mitigation strategies is demonstrated using simulated cascading failure data on an NPCC 140-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗