Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXCURSIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Experimental investigation on the flow instability behavior of a multi-channel boiling natural circulation loop at low-pressures

Natural circulation as a mode of heat removal is being considered as a prominent passive feature in the innovative nuclear reactor designs, particularly in boiling-water-reactors, due to its simplicity and economy. However, boiling natural circulation system poses many challenges to designer due to occurrence of various kinds of instabilities such as excursive instability, density wave oscillations, flow pattern transition instability, geysering and metastable states in parallel channels. This problem assumes greater significance particularly at low-pressures i.e. during startup, where there is great difference in the properties of two phases. In light of this, a parallel channel loop has been designed and installed that has a geometrical resemblance to the pressure-tube-type boiling-water-reactor, to investigate into the behavior of boiling natural circulation. The loop comprises of four identical parallel channels connected between two common plenums i.e. steam drum and header. The recirculation path is provided by a single downcomer connected between steam drum and header. Experiments have been conducted over a wide range of power and pressures (1-10 bar). Two distinct unstable zones are observed with respect to power i.e. corresponding to low power (Type-I) and high power (Type-II) with a stable zone at intermediate powers. The nature of oscillations in terms of their amplitude and frequency and their evolution for Type-I and Type-II instabilities are studied with respect to the effect of heater power and pressure. This paper discusses the evolution of unstable and stable behavior along with the nature of flow oscillation in the channels and the effect of pressure on it. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental investigation on the coolability of nuclear reactor debris beds using seawater

During the Fukushima nuclear reactor accident, seawater was injected into the reactor core to cool the decay heat from the heat generating porous debris bed. However, the impact of dissolved salts in water on the coolability of a debris bed is not well understood. This paper is one of the first works to investigate the cooling mechanisms for debris bed using seawater. An experimental system was built where the packed bed test section was volumetrically heated via a high frequency induction heater. The temperature along the axis of the test section was measured using a high resolution temperature sensor based on Optical Frequency Domain Reflectometry. Experimental results show that the dryout heat flux increases with an increase in concentration, with pure water having a dryout volumetric heat flux of 1.8 MW/m and salt water of concentration 7% having a dryout volumetric heat flux of 2.8 MW/m. However, this enhanced coolability using salt water is short term, as the crystallization fouling mechanism becomes significant over time and leads to gradual temperature excursion in the bed. The fouling mechanism eventually leads to a cross section of the debris bed to plug with the deposited salts, and this leads to a pressure build up in the lower regions of the debris bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress in metal-supported solid oxide electrolysis cells: A review

There is increasing global interest in using solid oxide electrochemical cells to perform electrolysis. Metal-supported solid oxide electrolysis cells (MS-SOEC) are being developed with stainless steel and Ni-based supports. Additionally, the use of porous metal to support the electrochemically-active layers is anticipated to improve mechanical strength, decrease cost, and increase tolerance to aggressive operating conditions, including rapid thermal excursions. This review summarizes and analyzes the previous decade of progress in MS-SOEC development, and identifies critical needs for future work.

08 HYDROGEN↗

Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy

Purpose: To determine treatment accuracy and margins for stereotactic lung radiotherapy with and without cone-beam CT (CBCT) image guidance. Methods and Materials: Acquired for the study were 308 CBCT of 24 patients with solitary peripheral lung tumors treated with stereotactic radiotherapy. Patients were immobilized in a stereotactic body frame (SBF) or alpha-cradle and treated with image guidance using daily CBCT. Four (T1) or five (T2/metastatic) 12-Gy fractions were prescribed to the planning target volume (PTV) edge. The PTV margin was {>=}5 mm depending on a pretreatment estimate of tumor excursion. Initial daily setup was according to SBF coordinates or tattoos for alpha-cradle cases. A CBCT was performed and registered to the planning CT using soft tissue registration of the target. The initial setup error/precorrection position, was recorded for the superior-inferior, anterior-posterior, and medial-lateral directions. The couch was adjusted to correct the tumor positional error. A second CBCT verified tumor position after correction. Patients were treated in the corrected position after the residual errors were {<=}2 mm. A final CBCT after treatment assessed intrafraction tumor displacement. Results: The precorrection systematic ({sigma}) and random errors ({sigma}) for the population ranged from 2-3 mm for SBF and 2-6 mm for alpha-cradle patients; postcorrection errors ranged from 0.4-1.0 mm. Calculated population margins were 9 to 13 mm (SBF) and 10-14 mm (cradle) precorrection, 1-2 mm (SBF), and 2-3 mm (cradle) postcorrection, and 2-4 mm (SBF) and 2-5 mm (cradle) posttreatment. Conclusions: Setup for stereotactic lung radiotherapy using a SBF or alpha-cradle alone is suboptimal. CBCT image guidance significantly improves target positioning and substantially reduces required target margins and normal tissue irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferences About Prostate Intrafraction Motion From Pre- and Posttreatment Volumetric Imaging

Purpose: To evaluate the ability of rectal filling, bladder filling, and prostate localization from pre- and posttreatment volumetric imaging to predict prostate intrafraction motion. Methods and Materials: Pre- and posttreatment cone beam computed tomography images (CBCTs) and intrafractional kV fluoroscopy were acquired at each fraction for 20 prostate patients in supine position, totaling 374 fractions available for analysis. Rectal and bladder filling status were evaluated for each CBCT, and correlation with prostate intrafraction motion measured from kV fluoroscopy was performed. The accuracy of pre and posttreatment prostate localization to predict intrafraction motion was evaluated. Results: Rectal filling status was a significant predictor of prostate intrafraction motion (p <0.001), and gas volume was correlated with the maximum vector displacement at MV delivery with a correlation coefficient (cc) of 0.37 and p <0.001. Prostate motion was greater for patients who consistently had gas volume >0.5 cm{sup 3} within the imaged region (cc = 0.52, p = 0.028). A weak relationship was found between bladder filling and posterior prostate drift for fractions with gas volume {<=}0.5 cm{sup 3} (cc = -0.17, p = 0.046). The sensitivity of detecting a 3-, 5-, and 7-mm excursion at MV delivery using posttreatment imaging was 76%, 75%, and 81% respectively. Conclusions: Rectal filling is a significant predictor of prostate intrafraction motion, whereas bladder filling is of limited usefulness. Pre- and posttreatment localization can provide a reasonable estimate of prostate motion during MV delivery when intrafraction localization is not available, with an error of 95% within 3.1 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model

Purpose: To present the implementation of a probability-based, four-dimensional (4D) intensity-modulated radiotherapy (IMRT) planning approach that explicitly optimizes the accumulated dose to moving tissue, estimated using the patient's probability density function (pdf) of respiratory motion. This is termed 'optimization in tissue's-eye-view'. Methods and Materials: The method incorporates 4D Monte Carlo dose calculation in multiple geometries of a respiratory-correlated CT dataset. The instance doses are weighted according to the breathing pdf and accumulated in a common reference geometry, which involves dose warping based on deformable registration. The algorithm produces deliverable multileaf collimator segments and was tested on a sample lung cancer patient dataset with large target excursion. Accumulated doses of the moving target and organs at risk of this plan were compared with those of corresponding margin-based static IMRT plans for free-breathing and gated treatment, as well as target tracking. Results: Target tracking provided best target coverage. Both the presented 4D IMRT approach for free-breathing treatment and gated treatment gave similar results for target coverage and lung dose, with significantly better target coverage than the margin-based static IMRT plan for free-breathing treatment. Conclusions: The presented 4D planning concept offers an alternative to gating by providing the optimal dose for free-breathing IMRT treatment. Although the focus of this study was 4D lung planning, the approach can be generally applied for IMRT optimization in randomly deforming patient models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy-Based Stereotactic Body Radiotherapy for Medically Inoperable Early-Stage Lung Cancer: Excellent Local Control

Purpose: To validate the use of stereotactic body radiotherapy (SBRT) using intensity-modulated radiotherapy (IMRT) beams for medically inoperable Stage I lung cancer. Methods and Materials: From February 2004 to November 2006, a total of 26 patients with 28 lesions received SBRT using a Novalis/BrainLAB system. Immobilization involved a Bodyfix vacuum cushion. A weighted abdominal belt limited respiratory excursion. Computed tomographic simulation images were acquired at rest, full inhalation, and full exhalation and were merged to generate an internal gross tumor volume (ITV). Dose was prescribed to cover the planning target volume (PTV), defined as PTV = ITV + 3-5 mm set-up margin. Heterogeneity corrections were used. Delivery of 50 Gy in five sequential fractions typically used seven nonopposing, noncoplanar beams. Image-guided target verification was provided by BrainLAB-ExacTrac. Results: Among the 26 patients, the mean age was 74 years (range, 49-88 years). Of the patients, 50% were male and 50% female. The median Karnofsky performance status was 70 (range, 40-100). The median follow-up was 30.9 months (range, 10.4-51.4 months). Tissue diagnosis was contraindicated in seven patients (26.9%). There were 22 T1 (78.6%) and six T2 (21.4%) tumors. The median conformality index was 1.38 (range, 1.12-1.8). The median heterogeneity index was 1.08 (range, 1.04-1.2). One patient (3.6%) developed acute Grade 3 dyspnea and one patient developed late Grade 2 chest wall pain. Actuarial local control and overall survival at 3 years were 94.4% and 52%, respectively. Conclusions: Use of IMRT-based delivery of SBRT using restriction of tumor motion in medically inoperable lung cancer demonstrates excellent local control and favorable survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility of Lung Tumor Location Using Various Methods of Respiratory Motion Mitigation

Purpose: To determine interfractional reproducibility of the location of lung tumors using respiratory motion mitigation. Methods and Materials: Free-breathing four-dimensional computed tomography (CT) data sets and CT data sets during breath hold were acquired weekly for 17 patients undergoing treatment for non-small-cell lung cancer. Distances between the center of the gross tumor volume (GTV) and a reproducible bony reference point under conditions of breath hold on end inspiration (EI) and end expiration (EE) and during free breathing on the 0% phase (corresponding to EI) and 50% phase (corresponding to EE) were analyzed for interfractional reproducibility. Systematic uncertainties in tumor location were determined as the difference in distance between the GTV center on the first CT data set and the mean location of GTV centers on the subsequent data sets. Random uncertainties in tumor location were determined as the standard deviation of the distances between the GTV centers and the bony reference points. Margins to account for systematic and random interfractional variations were estimated based on these uncertainties. Results: Mean values of interfractional setup uncertainties were as follows: systematic uncertainties-EI, 0.3 cm; EE, 0.2 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm; and random uncertainties-EI, 0.3 cm; EE, 0.3 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm. There does not appear to be any correlation between uncertainties and GTV size, but there appears to be a weak positive correlation between uncertainties and the magnitude of GTV excursion. Conclusions: Voluntary breath hold and gating on either EI or EE appear to be equally reliable methods of ensuring the reproducibility of lung tumor position. We recommend setup margins of 0.3 cm if using cone-beam CT or kilovoltage X-ray with fiducials and aligning directly to the tumor and 0.8 cm when aligning to a nearby bony surrogate using cone-beam CT or kilovoltage X-ray.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Variations in the Setup of Pelvic Bony Anatomy and Soft Tissue, and Their Implications on the Delivery of Proton Therapy for Localized Prostate Cancer

Purpose: To quantify daily variations in the anatomy of patients undergoing radiation therapy for prostate carcinoma, to estimate their effect on dose distribution, and to evaluate the effectiveness of current standard planning and setup approaches employed in proton therapy. Methods: We used series of computed tomography data, which included the pretreatment scan, and between 21 and 43 in-room scans acquired on different treatment days, from 10 patients treated with intensity-modulated radiation therapy at Morristown Memorial Hospital. Variations in femur rotation angles, thickness of subcutaneous adipose tissue, and physical depth to the distal surface of the prostate for lateral beam arrangement were recorded. Proton dose distributions were planned with the standard approach. Daily variations in the location of the prescription isodose were evaluated. Results: In all 10 datasets, substantial variation was observed in the lateral tissue thickness (standard deviation of 1.7-3.6 mm for individual patients, variations of >5 mm from the planning computed tomography observed in all series), and femur rotation angle (standard deviation between 1.3{sup o} and 4.8{sup o}, with the maximum excursion exceeding 10{sup o} in 6 of 10 datasets). Shifts in the position of treated volume (98% isodose) were correlated with the variations in the lateral tissue thickness. Conclusions: Analysis suggests that, combined with image-guided setup verification, the range compensator expansion technique prevents loss of dose to target from femur rotation and soft-tissue deformation, in the majority of cases. Anatomic changes coupled with the uncertainties of particle penetration in tissue restrict possibilities for margin reduction in proton therapy of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Interfractional Displacement of the Gastroesophageal Junction During Radiation Therapy for Esophageal Cancer

Purpose: Accounting for interfractional changes in tumor location improves the accuracy of radiation treatment delivery. The purpose of this study was to quantify the interfractional displacement of the gastroesophageal junction (GEJ) based on standard treatment setup in patients with esophageal cancer undergoing radiation therapy. Methods and Materials: Free-breathing four-dimensional computed tomography (4D-CT) datasets were acquired weekly from 22 patients during treatment for esophageal adenocarcinoma. Scans were registered to baseline (simulation) 4D-CT scans by using bony landmarks. The distance between the center of the GEJ contour on the simulation scan and the mean location of GEJ centers on subsequent scans was used to assess changes in GEJ location between fractions; displacement was also correlated with clinical and respiratory variables. Results: The mean absolute random error was 1.69 mm (range, 0.11-4.11 mm) in the lateral direction, 1.87 mm (range, 0.51-4.09 mm) in the anterior-posterior (AP) direction, and 3.09 mm (range, 0.99-6.16 mm) in the superior-inferior (SI) direction. The mean absolute systemic GEJ displacement between fractions was 2.88 mm lateral ({>=}5 mm in 14%), mostly leftward; 2.90 mm ({>=}5 mm in 14%) AP, mostly anterior; and 6.77 mm ({>=}1 cm in 18%) SI, mostly inferior. Variations in tidal volume and diaphragmatic excursion during treatment correlated strongly with systematic SI GEJ displacement (r = 0.964, p < 0.0001; and r = 0.944, p < 0.0001, respectively) and moderately with systematic AP GEJ displacement (r = 0.678, p = 0.0005; r = 0.758, p < 0.0001, respectively). Systematic displacement in the inferior direction resulted in higher-than-intended doses ({>=}60 Gy) to the GEJ, with increased hot-spot to the adjacent stomach and lung base. Conclusion: We found large (>1-cm) interfractional displacements in the GEJ in the SI (especially inferior) direction that was not accounted for when skeletal alignment alone was used for patient positioning. Because systematic displacement in the SI direction had dosimetric impact and correlated with tidal volume, better accounting for depth of breathing is needed to reduce interfractional variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Pancreatic Tumor Motion Using 4-Dimensional Computed Tomography and Surrogate Markers

Purpose: To assess intrafractional positional variations of pancreatic tumors using 4-dimensional computed tomography (4D-CT), their impact on gross tumor volume (GTV) coverage, the reliability of biliary stent, fiducial seeds, and the real-time position management (RPM) external marker as tumor surrogates for setup of respiratory gated treatment, and to build a correlative model of tumor motion. Methods and Materials: We analyzed the respiration-correlated 4D-CT images acquired during simulation of 36 patients with either a biliary stent (n=16) or implanted fiducials (n=20) who were treated with RPM respiratory gated intensity modulated radiation therapy for locally advanced pancreatic cancer. Respiratory displacement relative to end-exhalation was measured for the GTV, the biliary stent, or fiducial seeds, and the RPM marker. The results were compared between the full respiratory cycle and the gating interval. Linear mixed model was used to assess the correlation of GTV motion with the potential surrogate markers. Results: The average ± SD GTV excursions were 0.3 ± 0.2 cm in the left-right direction, 0.6 ± 0.3 cm in the anterior-posterior direction, and 1.3 ± 0.7 cm in the superior-inferior direction. Gating around end-exhalation reduced GTV motion by 46% to 60%. D95% was at least the prescribed 56 Gy in 76% of patients. GTV displacement was associated with the RPM marker, the biliary stent, and the fiducial seeds. The correlation was better with fiducial seeds and with biliary stent. Conclusions: Respiratory gating reduced the margin necessary for radiation therapy for pancreatic tumors. GTV motion was well correlated with biliary stent or fiducial seed displacements, validating their use as surrogates for daily assessment of GTV position during treatment. A patient-specific internal target volume based on 4D-CT is recommended both for gated and not-gated treatment; otherwise, our model can be used to predict the degree of GTV motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac Function After Multimodal Breast Cancer Therapy Assessed With Functional Magnetic Resonance Imaging and Echocardiography Imaging

Purpose: Breast intensity modulated radiation therapy (IMRT) reduces high-dose heart volumes but increases low-dose volumes. We prospectively assessed heart changes after 3D conformal RT (3DCRT) and IMRT for left-sided breast cancer. Heart dose was analyzed individually, 3DCRT patients were moderately exposed, and IMRT was performed only in patients with unacceptably high heart doses upon 3DCRT planning. Methods and Materials: In 49 patients (38 patients received 3DCRT; 11 patients received IMRT; and 20 patients received neoadjuvant or adjuvant chemotherapy) magnetic resonance imaging (MRI) and echocardiography were performed before and at 6, 12, and 24 months after treatment. Results: Mean heart dose for IMRT was 12.9 ± 3.9 Gy versus 4.5 ± 2.4 Gy for 3DCRT. Heart volumes receiving >40 Gy were 2.6% (3DCRT) versus 1.3% (IMRT); doses were >50 Gy only with 3DCRT. Temporary ejection fraction (EF) decrease was observed on MRI after 6 months (63%-59%, P=.005) resolving at 24 months. Only 3 patients had pronounced largely transient changes of EF and left ventricular enddiastolic diameter (LVEDD). Mitral (M) and tricuspid (T) annular plane systolic excursion (MAPSE and TAPSE) were reduced over the whole cohort (still within normal range). After 24 months left ventricular remodeling index decreased in patients receiving chemotherapy (0.80 vs 0.70, P=.028). Neither wall motion abnormalities nor late enhancements were found. On echocardiography, in addition to EF findings that were similar to those on MRI, global strain was unchanged over the whole cohort at 24 months after a transient decrease at 6 and 12 months. Longitudinal strain decreased in the whole cohort after 24 months in some segments, whereas it increased in others. Conclusions: Until 24 months after risk-adapted modern multimodal adjuvant therapy, only subclinical cardiac changes were observed in both 3DCRT patients with inclusion of small to moderate amounts of heart volume in RT tangents and in the patients treated with IMRT and reduced high-dose heart exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indirectly probing the structural change in ion-irradiated Zr-Based metallic glasses from small scale mechanical tests

Ion irradiation was applied to tailor the structural heterogeneities in Zr-based metallic glasses at room temperature. Experimental methods of X-ray diffraction, nanoindentation, and micropillar compression were conducted to examine the irradiation effects on their structural and mechanical property changes. It is found that the irradiated materials retained amorphous structure after room-temperature Ni ion irradiation. The reduction of elastic modulus and hardness measured by nanoindentation indicated the irradiation-induced mechanical degradation. A unified statistic model was employed to quantitatively predict the density and strength of irradiation defects, although their specific structural and physical nature is not explicitly included in this model. The transition of non-intersecting shear bands to multiple intersecting shear bands was observed on compression tests of irradiated micropillars with the increase of irradiation dose. Furthermore, the analysis of the displacement excursion of micropillar compression tests indicated a different deformation mode from the unirradiated state. These results from nanoindentation pop-in and micro-pillar compression tests suggested that irradiation eventually leads to a new state with different types and characteristics of structural heterogeneities from violent displacement cascades and non-equilibrium energy deposition/dissipation processes, which also proves ion irradiation as an effective method to tune the structure and mechanical properties of metallic glasses.

36 MATERIALS SCIENCE↗

Contamination control monitoring at the Los Alamos National Laboratory’s Plutonium Facility

Plutonium airborne contamination creates a particular hazard because of the possibility of intake by inhalation. To preclude excursions of radioactive materials into the operator’s breathing zone, controls are used to prevent contamination. Measures to control radioactive contamination include eliminating or minimizing the spread of contamination and preventing cross-contamination. Contamination control philosophy at the plutonium facility is conveyed in one simple statement: Detect the contamination closest to the source as possible! Speed and distance when self-monitoring is critical to detecting plutonium contamination. Responding correctly to an alarm or monitor not working properly minimizes the consequences of plutonium contamination. Performing a full body frisking correctly and using the Peerchecking tool also minimize the consequences of plutonium contamination.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Persistence of uranium groundwater plumes: Contrasting mechanisms at two DOE sites in the groundwater-river interaction zone

We examine subsurface uranium (U) plumes at two U.S. Department of Energy sites that are located near large river systems and that are influenced by groundwater-river hydrologic interaction. Following surface excavation of contaminated materials, both sites were projected to naturally flush remnant uranium contamination to levels below regulatory limits (e.g., 30 µg/L or 0.126 µmol/L; U.S. EPA drinking water standard), with 10 years projected for the Hanford 300 Area (Columbia River) and 12 years for the Rifle site (Colorado River). The rate of observed uranium decrease was much lower than expected at both sites. While uncertainty remains, a comparison of current understanding suggests that the two sites have common, but also different mechanisms controlling plume persistence. At the Hanford 300 A, the persistent source is adsorbed U(VI) in the vadose zone that is released to the aquifer during spring water table excursions. The release of U(VI) from the vadose zone and its transport within the oxic, coarse-textured aquifer sediments is dominated by kinetically-limited surface complexation. Modeling implies that annual plume discharge volumes to the Columbia River are small (< one pore volume). At the Rifle site, slow oxidation of naturally reduced, contaminant U(IV) in the saturated zone and a continuous influx of U(VI) from natural, up-gradient sources influences plume persistence. Rate-limited mass transfer and surface complexation also control U(VI) migration velocity in the sub-oxic Rifle groundwater. Flux of U(VI) from the vadose zone at the Rifle site may be locally important, but it is not the dominant process that sustains the plume. A wide range in microbiologic functional diversity exists at both sites. Strains of Geobacter and other metal reducing bacteria are present at low natural abundance that are capable of enzymatic U(VI) reduction in localized zones of accumulated detrital organic carbon or after organic carbon amendment. Major differences between the sites include the geochemical nature of residual, contaminant U; the rates of current kinetic processes (both biotic and abiotic) influencing U(VI) solid-liquid distribution; the presence of detrital organic matter and the resulting spatial heterogeneity in microbially-driven redox properties; and the magnitude of groundwater hydrologic dynamics controlled by river-stage fluctuations, geologic structures, and aquifer hydraulic properties. The comparative analysis of these sites provides important guidance to the characterization, understanding, modeling, and remediation of groundwater contaminant plumes influenced by surface water interaction that are common world-wide.

Environmental Molecular Sciences Laboratory↗

Separation of metallic residues from the dissolution of a high-burnup BWR fuel using nitrogen trifluoride

Nitrogen trifluoride (NF 3 ) was used to fluorinate the metallic residue from the dissolution of a high burnup, boiling water reactor fuel (~70 MWd/kgU). The metallic residue included the noble metal phase (containing ruthenium, rhodium, palladium, technetium, and molybdenum), and smaller amounts of zirconium, selenium, tellurium, and silver. Exposing the noble metal phase to 10% NF 3 in argon between 400 and 550°C, removed molybdenum and technetium near 400°C as their volatile fluorides, and ruthenium near 500C as its volatile fluoride. The events were thermally and temporally distinct and the conditions specified are a recipe to separate these transition metals from each other and from the noble metal phase nonvolatile residue. Depletion of the volatile fluorides resulted in substantial exothermicity. Thermal excursion behavior was recorded under non-adiabatic, isothermal conditions that typically minimize heat release. Physical characterization of the metallic noble phase and its thermal behavior are consistent with high kinetic velocity reactions encouraged by the nanoparticulate phase or perhaps catalytic influences of the mixed platinum metals with nearly pure phase structure. Post-fluorination, only two phases were present in the residual nonvolatile fraction. These were identified as a nano-crystalline, metallic palladium cubic phase and a hexagonal rhodium trifluoride (RhF 3 ) phase. The two phases were distinct as the sub-µm crystallites of metallic palladium were in contrast to the RhF 3 phase, which grew from the parent nano-crystalline noble-metal phase during fluorination, to acicular crystals exceeding 20-µm in length.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗