At least 415 records · Page 23

Remote sensing and snowpack management

The present work describes the use of an airborne electromagnetic sensing system for measuring snowpack depth, density, and water content. A transmitter sends a sequence of pulses of stepped frequencies, and the reflections are measured by a sensitive receiver. The combination of the snowpack and the earth interacts with the electromagnetic wave so as to modify the characteristics of the reflected signals. The variation of the reflected intensity with frequency provides the desired data. A theoretical analysis of return signal and snowpack parameter relationships is given, and the results of experimental verification of the theory are discussed.

Linlor, W. I.↗

Spaceborne radar

The spaceborne radar panel considered how radar could be used to measure precipitation from satellites. The emphasis was on how radar could be used with radiometry (at microwave, visible (VIS), and infrared (IR) wavelengths) to reduce the uncertainties of measuring precipitation with radiometry alone. In addition, the fundamental electromagnetic interactions involved in the measurements were discussed to determine the key work areas for research and development to produce effective instruments. Various approaches to implementing radar systems on satellites were considered for both shared and dedicated instruments. Finally, a research and development strategy was proposed for establishing the parametric relations and retrieval algorithms required for extracting precipitation information from the radar and associated radiometric data.

Moore, R. K.↗

Design and construction of a remote sensing apparatus

The methods of identifying plant and soil types using remote sensing techniques are described. The equipment employed consists of a balloon system and a mobile remote sensing laboratory housing a radiometer which is mounted on a turret mechanism. The radiometer is made up of a telescope whose lenses are replaced by mirrors which channel received radiation into a monochromator. The radiation is then focused onto detectors for measurement of the intensity of the electromagnetic energy as a function of wavelength. Measurements from a wavelength of 0.2 microns to 15 microns are obtained with the system. diagrams are provided.

Maples, D.↗

Short Wavelength Electromagnetic Perturbations Excited Near the Solar Probe Plus Spacecraft in the Inner Heliosphere: 2.5D Hybrid Modeling

A 2.5D numerical plasma model of the interaction of the solar wind (SW) with the Solar Probe Plus spacecraft (SPPSC) is presented. These results should be interpreted as a basic plasma model derived from the SW-interaction with the spacecraft (SC), which could have consequences for both plasma wave and electron plasma measurements on board the SC in the inner heliosphere. Compression waves and electric field jumps with amplitudes of about 1.5 V/m and (12-18) V/m were also observed. A strong polarization electric field was also observed in the wing of the plasma wake. However, 2.5D hybrid modeling did not show excitation of whistler/Alfven waves in the upstream connected with the bidirectional current closure that was observed in short-time 3D modeling SPPSC and near a tether in the ionosphere. The observed strong electromagnetic perturbations may be a crucial point in the electromagnetic measurements planned for the future Solar Probe Plus (SPP) mission. The results of modeling electromagnetic field perturbations in the SW due to shot noise in absence of SPPSC are also discussed.

Lipatov, Alexander S.↗

Scalable multiphoton quantum metrology with neither pre- nor post-selected measurements

The quantum statistical fluctuations of electromagnetic fields establish a limit, known as the shot-noise limit, on the sensitivity of optical measurements performed with classical technologies. However, quantum technologies are not constrained by this shot-noise limit. In this regard, the possibility of using every photon produced by quantum sources of light to estimate small physical parameters, beyond the shot-noise limit, constitutes one of the main goals of quantum optics. Here, we experimentally demonstrate a scalable protocol for quantum-enhanced optical phase estimation across a broad range of phases, with neither pre- nor post-selected measurements. This is achieved through the efficient design of a source of spontaneous parametric downconversion in combination with photon-number-resolving detection. The robustness of two-mode squeezed vacuum states against loss allows us to outperform schemes based on N00N states, in which the loss of a single photon is enough to remove all phase information from a quantum state. In contrast to other schemes that rely on N00N states or conditional measurements, the sensitivity of our technique could be improved through the generation and detection of high-order photon pairs. This unique feature of our protocol makes it scalable. Furthermore, our work is important for quantum technologies that rely on multiphoton interference such as quantum imaging, boson sampling, and quantum networks.

36 MATERIALS SCIENCE↗

Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Propellant tanks↗

Compatibility of the Radio Frequency Mass Gauge with Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98. Together, these results suggested that a tank constructed from graphite-epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 Q 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Radio frequencies↗

Ocean Color Instrument Integration and Testing

This paper describes the plans, flows, key facilities, components and equipment necessary to fully integrate, functionally test, qualify and calibrate the Ocean Color Instrument (OCI) on the Plankton, Aerosols, Clouds, and oceans Ecosystem (PACE) observatory. PACE is currently in the design phase of mission development. It is scheduled to launch in 2022, extending and improving NASA's twenty-year record of satellite observations of global ocean biology, aerosols and clouds. PACE will advance the assessment of ocean health by measuring the distribution of phytoplankton, which are small plants and algae that sustain the marine food web. It will also continue systematic records of key atmospheric variables associated with air quality and the Earth's climate. PACE's primary sensor, the OCI, is a highly advanced optical spectrometer that will be used to measure properties of light over portions of the electromagnetic spectrum. It will enable continuous measurement of light at finer wavelength resolution than previous NASA satellite sensors, extending key system ocean color data records for climate studies. The color of the ocean is determined by the interaction of sunlight with substances or particles present in seawater such as chlorophyll. By monitoring global phytoplankton distribution and abundance with unprecedented detail, the OCI will contribute to a better understanding of the complex systems that drive ocean ecology and it's impacts on global fisheries. This paper will focus on the Integration and Test (I&T) activities for OCI while it is at the NASA Goddard Space Flight Center. The OCI integration consists of assembly and alignment of the rotating telescope, electronics box integration, fixed deck assembly integration, thermal systems integration and the final assembly and testing. This I&T phase will be followed by the OCI calibration and characterization, environmental tests which include electromagnetic interference (EMI)/electromagnetic compatibility (EMC), vibration with sine sweep, acoustics, shock, thermal balance, thermal vacuum, mass properties and center of gravity. This paper will briefly discuss OCI shipment and delivery to the spacecraft vendor for observatory level I&T as well as some launch preparation activities.

Petro, Susanna↗

Complex Permittivities of Candidate Radome Materials at W-band

This report presents the results of w-band complex permittivity measurements performed in NASA Langley's Electromagnetics Research Branch. The test articles included in the permittivity study were flat panels of materials which are under consideration for use in a radome for the Passive Millimeter Wave Camera (PMMWC) flight experiment. This experiment is scheduled to fly on the Air Force's 'Speckled Trout' aircraft in late 1997. The radome design is very important because the PMMWC can tolerate only a small amount of electromagnetic loss through the radome. A free space measurement system was used to obtain complex reflection and transmission coefficients of the samples. The frequency of interest was 89 GHz, so measurements were performed over a range of 79 to 99 GHz. The transmission and reflection coefficients were used, along with the measured sample thickness, to calculate complex permittivity over the frequency range. The material samples measured in this study can be divided into four categories: skin materials, core materials, coating materials, and layered samples.

Cravey, Robin↗

High-frequency instability of the sheath-plasma resonance

Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

High-frequency instability of the sheath-plasma resonance

Coherent high-frequency oscillations near the electron plasma frequency are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diodelike electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening, and copious harmonics. The fundamental instability is a bounded oscillation caused by wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres), which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line-broadening mechanism has been identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burstlike RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

Simultaneous Noncontact Precision Imaging of Microstructural and Thickness Variation in Dielectric Materials Using Terahertz Energy

A process for simultaneously measuring the velocity of terahertz electromagnetic radiation in a dielectric material sample without prior knowledge of the thickness of the sample and for measuring the thickness of a material sample using terahertz electromagnetic radiation in a material sample without prior knowledge of the velocity of the terahertz electromagnetic radiation in the sample is disclosed and claimed. The process evaluates, in a plurality of locations, the sample for microstructural variations and for thickness variations and maps the microstructural and thickness variations by location. A thin sheet of dielectric material may be used on top of the sample to create a dielectric mismatch. The approximate focal point of the radiation source (transceiver) is initially determined for good measurements.

Roth, Donald J↗

Processing Waveform-Based NDE

A computer implemented process for simultaneously measuring the velocity of terahertz electromagnetic radiation in a dielectric material sample without prior knowledge of the thickness of the sample and for measuring the thickness of a material sample using terahertz electromagnetic radiation in a material sample without prior knowledge of the velocity of the terahertz electromagnetic radiation in the sample is disclosed and claimed. Utilizing interactive software the process evaluates, in a plurality of locations, the sample for microstructural variations and for thickness variations and maps the microstructural and thickness variations by location. A thin sheet of dielectric material may be used on top of the sample to create a dielectric mismatch. The approximate focal point of the radiation source (transceiver) is initially determined for good measurements.

Roth, Donald J↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with long cathodes in a high power, quasi-steady MPD discharge show that the critical current for the onset of voltage fluctuations, which was previously shown to be a function of cathode area, approaches an asymptote for cathodes of very large surface area. Floating potential measurements and photographs of the discharge luminosity indicate that the fluctuations are confined to the vicinity of the cathode and hence reflect a cathode emission process rather than a fundamental limit on MPD performance. Photoelectric measurements of particular argon neutral and ion transitions show that the higher electronic states are populated more heavily than would be calculated on the basis of Saha-Boltzmann equilibrium at the local electron temperature and number density. Preliminary optical depth measurements show that for a current of 4 kA and an argon mass flow of 12 g/sec, a population inversion exists between the upper and lower states of the 4880 A argon ion transition.

Jahn, R. G.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗