Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRIC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Automated Mobility Platforms (AMPs) for Versatile, Energy Efficient, Facility and District Scale Transport

The Automated Mobility Platforms (AMPs) concept is envisioned as an on-demand network of automated lightweight electric vehicles serving mobility needs in a large facility or district-scale setting. Supplanting the function of legacy automated people mover systems, AMPs is scalable to meet the needs of moving people in large interior spaces with destinations that are too distant for walking and in which larger motor vehicles would be unfeasible or undesirable. The AMPs system is designed for automated management and operation, extending to how and where the vehicles are sent to serve mobility needs, as organized through a supervisory management system. AMPs vehicles are requested by users via smartphone app or buttons located on interactive infrastructure elements. AMPs vehicles function similarly to elevators, though in the horizontal plane, wherein users summon vehicles, and are moved point-to-point, with user requested destinations set through intuitive interfaces. The concept targets extensibility, manageability, and performance improvements over legacy technologies, with accessibility and safety features integrally designed into the system.

ADA supportive modes↗

Advanced Non-Destructive Assay Systems and Special Instrumentation Requirements for Spent Nuclear Fuel Recycling Facilities

The safe and efficient operation of the next generation of Spent Nuclear Fuel (SNF) recycling / reprocessing facilities is dependent upon the availability of high performance real time Non- Destructive Assay (NDA) systems at key in-line points. A diverse variety of such special instrument systems have been developed and commissioned at reprocessing plants worldwide over the past fifty years.. The measurement purpose, technique and plant performance for selected key systems have been reviewed. Obsolescence issues and areas for development are identified in the context of the measurements needs of future recycling facilities and their associated waste treatment plants. Areas of concern include (i) Materials Accountancy and Safeguards, (ii) Head End process control and feed envelope verification, (iii) Real-time monitoring at the Product Finishing Stages, (iv) Criticality safety and (v) Radioactive waste characterization. Common characteristics of the traditional NDA systems in historical recycling facilities are (i) In-house development of bespoke instruments resulting in equipment that if often unique to a given facility and generally not commercially available, (ii) Use of 'novel' techniques - not widely deployed in other applications, (iii) Design features that are tailored to the specific plant requirements of the facility operator, (iv) Systems and software implementation that was not always carried out to modern industry standards and (v) A tendency to be overly complex - refined by on-plant operational usage and experience. Although these systems were 'validated in use' and are generally fit for purpose, there are a number of potential problems in transferring technology that was developed ten or more years ago to the new build SNF recycling facilities of the future. These issues include (i) Obsolescence of components - particularly with respect to computer hardware and data acquisition electronics, (ii) Availability of Intellectual Property and design drawings and documentation (iii) Lack of compatibility with modern computers, software, data transfer networks, digital protocols and electrical code standards, (iv) Non-compliance with current and future mandatory standards and regulations for nuclear facilities (v) Design focused on measurement and control points that may be specific to the facility process (vi) Lack of utilization of recent technological advances where better performing, less complex and more cost-effective options are now available. Key radiometric measurement drivers and control points for future recycling facilities have been determined and a review of the adequacy of existing instrumentation has been performed. Areas where recent technology improvements may be more effectively deployed and future technology development may be appropriate are identified. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize the R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.

97 MATHEMATICS AND COMPUTING↗

Estimation of reactive fluxes in gradient stochastic systems using an analogy with electric circuits

Highlights: •The MaxFlux functional should be called the resistivity functional. •A Hamilton–Jacobi approach for computing transition paths in collective variables. •Conversion of the network of reactive channels into an electric circuit. •Test on the Alanine-Dipeptide. Perfect agreement. •Application to the problem of CO escape from Myoglobin. -- Abstract: We propose an approach for finding dominant reactive channels and calculating percentages of reactive flux through each channel in chemical systems driven by a deterministic potential force and a small thermal noise. We assume that the temperature is low enough so that the reactive flux focuses around a finite number of paths connecting the reactant and the product states. These paths can be found in a systematic way by solving a Hamilton–Jacobi equation for the so called MaxFlux functional. We argue that the name “MaxFlux” is misleading: it should be called the resistivity functional instead. Once the network of transition paths is found, one can define an equivalent electric circuit and find the currents through each of its wires. These currents give estimates of the reactive flux along the corresponding transition paths. We test our approach on the problem of finding transition paths in the Alanine-Dipeptide with two dihedral angles where the reactive current can be computed exactly. The percentages of the reactive flux through each reactive channel given by our approach turn out to be in remarkable agreement with the exact ones. We apply this approach to the problem of finding escape paths of a CO molecule from a Myoglobin protein. We find a collection of exit locations and establish percentages of the reactive flux through each of them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal energy storage to minimize cost and improve efficiency of a polygeneration district energy system in a real-time electricity market

District energy systems can produce low-cost utilities for large energy networks, but can also be a resource for the electric grid by their ability to ramp production or to store thermal energy by responding to real-time market signals. In this work, dynamic optimization exploits the flexibility of thermal energy storage by determining optimal times to store and extract excess energy. This concept is applied to a polygeneration distributed energy system with combined heat and power, district heating, district cooling, and chilled water thermal energy storage. The system is a university campus responsible for meeting the energy needs of tens of thousands of people. The objective for the dynamic optimization problem is to minimize cost over a 24-h period while meeting multiple loads in real time. The paper presents a novel algorithm to solve this dynamic optimization problem with energy storage by decomposing the problem into multiple static mixed-integer nonlinear programming (MINLP) problems. Another innovative feature of this work is the study of a large, complex energy network which includes the interrelations of a wide variety of energy technologies. Results indicate that a cost savings of 16.5% is realized when the system can participate in the wholesale electricity market.

25 ENERGY STORAGE↗

Electrical Transmission Substation Connectivity Model - Literature Review and Model Formulation Development

Transmission substations are key assets in bulk electric power systems. The loss of a substation can remove many electrical transmission buses from the transmission network, resulting in power flow congestion and forcing generation redispatch or load shedding to avoid subsequent, potentially cascading, failures. In addition, load-serving transmission substations are source points of electrical power into lower voltage sub-transmission and distribution networks. The loss of these substations may directly result in outages of connected networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RED-BL: Evaluating dynamic workload relocation for data center networks

In this study, we present RED-BL (Relocate Energy Demand to Better Locations), a framework to minimize the electricity cost for operating data center networks over consecutive intervals of fixed duration. Within each interval, RED-BL provides a mapping of workload to a set of geographically distributed data centers. To this end, RED-BL uses the geographical and temporal variations in electricity prices as exhibited by electrical energy markets. In addition, we incorporate the transition costs associated with a change in workload mapping from one interval to the next, over a planning window comprising multiple such intervals. This results in a sequence of workload mappings that is optimal over the entire planning window, even though the workload mapping in a given interval may not be locally optimal. Our evaluation of RED-BL uses electricity prices from the US markets and workload traces from live Internet applications with millions of users. We find that RED-BL can reduce the electric bill by as much as 45% compared to the case when the workload is uniformly distributed. When compared to existing workload relocation solutions, for a wide range of data center deployment sizes, RED-BL achieves electricity cost savings that are 8.28% higher, on average. This seemingly modest reduction can save millions of dollars for the operators. The cost of this saving is an inexpensive computation at the start of each planning window.

97 MATHEMATICS AND COMPUTING↗

System state estimation with asynchronous measurements

The present disclosure provides techniques for estimating network states using asynchronous measurements by leveraging network inertia. For example, a device configured in accordance with the techniques of the present disclosure may receive electrical parameter values corresponding to at least one first location within a power network and determine, based on the electrical parameter values and a previous estimated state of the power network, an estimated value of unknown electrical parameters that correspond to a second location within the power network. The device may further cause at least one device within the power network to modify operation based on the estimated value of the unknown electrical parameters. The leveraging of network inertia may obviate the need for probabilistic models or pseudo-measurements.

Cavraro, Guido↗

EVI-RoadTrip™: Electric Vehicle Infrastructure for Road Trips [SWR-22-17]

The EVI-RoadTrip™ tool offers high-resolution refueling network design and analysis to inform electric vehicle (EV) charging infrastructure development for road trips or long-distance travels. EVI-RoadTrip helps infrastructure planners, analysts, and decision makers evaluate EV energy consumption and corresponding charging demands along the routes-between origin and destination. It considers the projected location and characteristics of charging stations, potential electric grid impacts, and required infrastructure improvements. Strategically located charging stations for long-distance travel are critical to enabling the widespread adoption of EVs by allowing them to travel further beyond city or town boundaries. Sophisticated analysis and planning can identify the points (e.g., corridors) that may require increased availability of EV charging stations to support electrified road trips.

Wood, Eric↗

Solar Utility Network Deployment Acceleration

The National Rural Electric Cooperative Association (NRECA) is the national association representing 833 distribution and 62 generation and transmission (G&T) cooperatives. From booming suburbs to remote rural farming communities, America’s electric cooperatives are energy providers and engines of economic development and way of life for more than 19 million American homes, businesses, farms, and schools in 47 states across the U.S. Member owned and responsive, generally smaller than investor-owned and municipal utilities, often more nimble in services for members, co-ops provide the U.S. Department of Energy (DOE) with a strong partner for testing and accelerating utility-scale solar design, pricing, and delivery models.

14 SOLAR ENERGY↗

Networked Microgrids for Self-healing Power Systems

This paper proposes a transformative architecture for the normal operation and self-healing of networked microgrids (MGs). MGs can support and interchange electricity with each other in the proposed infrastructure. The networked MGs are connected by a physical common bus and a designed two-layer cyber communication network. The lower layer is within each MG where the energy management system (EMS) schedules the MG operation; the upper layer links a number of EMSs for global optimization and communication. In the normal operation mode, the objective is to schedule dispatchable distributed generators (DGs), energy storage systems (ESs) and controllable loads to minimize the operation costs and maximize the supply adequacy of each MG. When a generation deficiency or fault happens in a MG, the model switches to the self-healing mode and the local generation capacities of other MGs can be used to support the on-emergency portion of the system. A consensus algorithm is used to distribute portions of the desired power support to each individual MG in a decentralized way. The allocated portion corresponds to each MG’s local power exchange target which is used by its EMS to perform the optimal schedule. The resultant aggregated power output of networked MGs will be used to provide the requested power support. Test cases demonstrate the effectiveness of the proposed methodology.

Consensus Algorithm↗

Earthquake Risk Management of Underground Lifelines in the Urban Area of Catania

Lifelines typically include the following five utility networks: potable water, sewage natural gas, electric power, telecommunication and transportation system. The response of lifeline systems, like gas and water networks, during a strong earthquake, can be conveniently evaluated with the estimated average number of ruptures per km of pipe. These ruptures may be caused either by fault ruptures crossing, or by permanent deformations of the soil mass (landslides, liquefaction), or by transient soil deformations caused by seismic wave propagation. The possible consequences of damaging earthquakes on transportation systems may be the reduction or the interruption of traffic flow, as well as the impact on the emergency response and on the recovery assistance. A critical element in the emergency management is the closure of roads due to fallen obstacles and debris of collapsed buildings.The earthquake-induced damage to buried pipes is expressed in terms of repair rate (RR), defined as the number of repairs divided by the pipe length (km) exposed to a particular level of seismic demand; this number is a function of the pipe material (and joint type), of the pipe diameter and of the ground shaking level, measured in terms of peak horizontal ground velocity (PGV) or permanent ground displacement (PGD). The development of damage algorithms for buried pipelines is primarily based on empirical evidence, tempered with engineering judgment and sometimes by analytical formulations.For the city of Catania, in the present work use has been made of the correlation between RR and peak horizontal ground velocity by American Lifelines Alliance (ALA, 2001), for the verifications of main buried pipelines. The performance of the main buried distribution networks has been evaluated for the Level I earthquake scenario (January 11, 1693 event I = XI, M 7.3) and for the Level II earthquake scenario (February 20, 1818 event I = IX, M 6.2).Seismic damage scenario of main gas pipelines and water has been obtained, with PGV values calculated for level I and level II earthquake scenarios.

58 GEOSCIENCES↗

MADE3D™ (Manufacturing and Additive Design of Electric Machines Enabled by Three-Dimensional Printing) [SWR-20-70]

The MADE3D™ software uses advanced neural networks for realizing novel high torque density electric machine designs with desired functional specifications not limited to but including torque, magnetic loading, and mass. This software allows for a reduction in cost of design by using next-generation computational resources including the cloud while still maintaining high accuracy. The design of the neural networks allows for exploration of large design space and possibilities to find more optimal designs and accommodate new manufacturing technologies like 3D printing.

Sethuraman, Latha↗

Smart Grid Enabled EVSE

The combined team of GE Global Research, Federal Express, National Renewable Energy Laboratory, and Consolidated Edison has successfully achieved the established goals contained within the Department of Energy’s Smart Grid Capable Electric Vehicle Supply Equipment funding opportunity. The final program product, shown charging two vehicles in Figure 1, reduces by nearly 50% the total installed system cost of the electric vehicle supply equipment (EVSE) as well as enabling a host of new Smart Grid enabled features. These include bi-directional communications, load control, utility message exchange and transaction management information. Using the new charging system, Utilities or energy service providers will now be able to monitor transportation related electrical loads on their distribution networks, send load control commands or preferences to individual systems, and then see measured responses. Installation owners will be able to authorize usage of the stations, monitor operations, and optimally control their electricity consumption. These features and cost reductions have been developed through a total system design solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelling DC responses of 3D complex fracture networks

Here, the determination of the geometrical properties of fractures plays a critical role in many engineering problems to assess the current hydrological and mechanical states of geological media and to predict their future states. However, numerical modeling of geoelectrical responses in realistic fractured media has been challenging due to the explosive computational cost imposed by the explicit discretizations of fractures at multiple length scales, which often brings about a tradeoff between computational efficiency and geologic realism. Here, we use the hierarchical finite element method to model electrostatic response of realistically complex 3D conductive fracture networks with minimal computational cost.

58 GEOSCIENCES↗

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.

Galbiati, C.↗